Honeywell Combination Fire & Burglary Control Panel
Agenda VISTA 128FBPT Fire & Burglary Design & Scalability of VISTA Fire TURBO (FBPT) Honeywell Fire & Intrusion panel USP 5800 Series Wireless Sensor 5800 Series Life Safety Wireless Sensor Vault Seismic Sensors: SC100 / SC-105 Range of Smoke Detectors
VISTA 128BPT Burglary cum Fire Panel Maximum Zone Capacity 128 Standard Wired Zones 8 Maximum Wireless Zones 127 Event Log 500 Addressable Fire Expansion Method No. of Conventional Fire Zones V-Plex Polling Loop (twowire) (2) Two-wire smoke loops on board with optional expansion Combination Burglary & Fire Control Panel. Partitions 8 User Codes 150 Provision for Wired zones expansion, at extra cost
VISTA FBPT : Fire/Burglary Control Panel Maximum Zone Capacity 128 Standard Wired Zones 8 Maximum Wireless Zones 127 Event Log 500 Combination Fire & Burglary Control Panel. Addressable Fire Expansion Method No. of Conventional Fire Zones V-Plex Polling Loop (twowire) (2) Two-wire smoke loops on board with optional expansion Partitions 8 User Codes 150 Provision for Wired zones can be expansion, at extra cost
Design & Scalability of VISTA Fire & Burglary TURBO (FBPT) Control Panel: V32FB-9 V128FBP-9 V250FBP-9 AlarmNet Communicator: igsmcf (VISTA) OH-iPGSMDP (Other FACP w/contact ID) 5881ENHC Receiver 5883H Transceiver 5800CO CO Detector 5809 Heat Detector 5808W3 Smoke Detector 5817CB Fire Transmitter ECP-ISO Bus Isolator 6160CR-2 Fire Command Genesis 4107 ECP BUS 4208SNF 4209U 4297 Bus Extender VPLEX-VSI Bus Isolator 4193SN 1-Zone Input 5140MPS Pull Station Genesis 4106 SLC Circuit 0D-HP300ULM NAC Power Supply (As needed) 4101SN Relay Output 5193SD Smoke Detector 5602 Heat Detector 5140MPS Pull Station To Waterflow And PIV Devices Two CLASS A Loops Six CLASS B Loops Four 2-wire Smoke Loops Release, Recall Reset 4208SN 8-Zone Input Genesis 4111 NAC Circuit Notification Appliances
SLC Vplex Fire Devi 4297 Extender Module VPLEX- VSI 4208SN/SNF 5193SD/SDT Conventional Devices 4101SN 4293SN 4190SN
VSI Module Features Detects and isolates Complete or Resistive Shorts Overloads Defective Polling Loop Devices On power Up and On Going New or Existing Installations UL Burg/Fire From Control To downstream circuits To Isolated Branch Circuit LED Trouble Indicator Driving Efficiency While Reducing Cost
V-Plex Optimized System with VSI VSI VSI VSI VSI VSI = Motion = Contacts = Glass Break = Point/Relay = VSI
Honeywell s Competitive Edge (USP) Product UL Certified Panels & Sensors, meeting RBI Guidelines Easy to Operate - Keypads with Voice Prompts Panels supports small & large installation base Solution Built-in fire zone & PSTN Digital Dialer for CMS Easy upgrade to IP Connectivity Panels integrate with CCTV & Access Control Service Online Support for Programming & Service Easy to install & program the products, remotely & online Easy to check the health status of Panels Operational Low Maintenance & Good Value for Money Low power consumption & Twice the Battery life Stable system, very Low failure rates
Wired & Wireless Sensors WIRED SENSORS ASC-SS1 Glass Break Shock Sensor WIRELESS SENSORS 5800SS1 Glass Break Shock Sensor FG1625T Glass Break Detector 5853 Glass Break Detector MPS45WGW Magnetic Contact 5816WMWH Magnetic Contact IS310 Request To Exit Sensor 5870API Asset Protection Aurora-T Motion Detector With Pet Immunity 5890 Motion Detector 2351E + B401 Two Wire Smoke Detector 5808W3 Smoke Detector
5800 Series Wireless Sensor
5800 Series Life Safety Wireless Sensor AP 5804C
Vault Seismic Sensors: SC100 / SC-105 Seismic sensor is specifically designed to protect armored rooms, strong room vaults, safes, night deposit, chests, ATM Cabinet is tamper protected against case opening and pry off from the mounting surface. Its IP/IK is also high: IP=43, IK=04. Also cover is equipped with a thin stainless steel shield, difficult to drill, and generates lot of strong vibrations. SC100 / SC105 is- 24-hour surveillance of vaults, doors, safes, ATMs and other high value storage units Flat frequency response sensor for genuine signal analysis DIP switch sensitivity settings Noise sensitivity settings using built-in diagnostic tool Integrated EOL resistors High detection capability Low current consumption Standard drill shield protection Miniature metal housing fits better in narrow applications Led Temperature at start = 21 C; At least 40% smaller than competition SC100 = 80 x 60 x 21 mm. Easy to set: dipswitches and diagnostic LED No tools!! 60 seconds later Temp. = 28 C Alarm Rate-of-rise alarm: alarm when temperature increases more than 6 C/minute (thermal attack)
Range of Smoke Detectors V-Plex 5193SD Photoelectronic V-plex smoke detector - Low profile design - V-Plex addressable loop device - Automatic maintenance reporting - Available with integral heat sensor - Simple 2 wire installation - DIP switch or serial number programmable Wireless 5808 Low profile photo electronic smoke detector - Commercial or Domestic Usage - Tamper protected against removal - On-board 85db sounder - Fully supervised 5809 Wireless heat detector - Rate of Rise / Fixed temperature heat detector - Resettable on rate of rise operation - Tamper supervision
Your Trusted Partner in Protection Honeywell s commitment to your security goes beyond offering the highest-quality products. When you purchase Honeywell products, you also get the peace of mind from knowing that a wealth of experience, innovation and proven performance are built into every one. Why trust your security to anything less?
www.honeywell.com