Model ESFR-25 Early Suppression, Fast Response Pendent Sprinklers 25.2 K-factor General Description

Similar documents
Model ESFR-17 Early Suppression, Fast Response Upright Sprinklers 16.8 K-factor General Description

Sprinkler Identification Numbers

Model ESFR K-factor Pendent Sprinkler Early Suppression, Fast Response General Description. Sprinkler Identification Number (SIN)

The Series LFII (TY3596) Residential

Series TY-FRL 5.6 and 8.0 K-factor Extended Coverage Horizontal Sidewall Sprinklers Quick & Standard Response (Light Hazard)

Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K Upright, and Pendent Extended Coverage Light and Ordinary Hazard General Description

Model/Sprinkler Identification Number JULY, 2011 WARNINGS

Series ELO-231 Upright and Pendent Sprinklers. Standard Response, Standard Coverage, General Description

Series ELO-231B 11.2 K-factor Upright and Pendent Sprinklers. Standard Response, Standard Coverage, General Description

Series TY-B & TY-FRB, 10 mm Orifice, ISO 7/1-R3/8 Upright, Pendent, and Recessed Pendent Sprinklers Standard and Quick Response General Description

Series LFII Residential Sprinklers Flat-Plate Concealed Pendent 4.9 K-Factor General Description

Model ESFR-17 Dry Type Pendent Sprinklers Early Suppression Fast Response 16.8 K-factor General Description

ILLUSION 11.2 K-factor Extra Large Orifice Concealed Pendent Sprinklers Quick Response, Standard Coverage General Description

Model CHEC 8.0 K-factor Concealed Horizontal Extended Coverage Quick Response Light Hazard, Sidewall Sprinklers General Description

Series TY-B 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General Description

Model/Sprinkler Identification Numbers

Model ELOC 11.2 K-factor Extra Large Orifice Concealed Pendent Sprinklers Quick and Standard Response, Extended Coverage

Series RFII 5.6 K-factor. Flush II Concealed Pendent Sprinklers

Design Criteria. Installation

Series LFII Residential Pendent Sprinklers 4.9 K-factor General Description

Model WS Specific Application Window Sprinklers Horizontal and Pendent Vertical Sidewall 5.6 K-Factor General Description

Model ESFR-17 Dry Type Pendent Sprinklers Early Suppression Fast Response 16.8 K-factor General Description

Series LFII Residential Flush Pendent Sprinklers 4.2 K-factor General Description

5.6K Horizontal Sidewall Standard and Quick Response, Extended Coverage General Description. Model/Sprinkler Identification Numbers (SINs)

Sprinkler Identification Number TY ECLH HSW, 8.0K, 3/4"NPT

Series TY-FRL 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

Series TY-FRL 5.6 and 8.0 K-factor Extended Coverage Horizontal Sidewall Sprinklers Quick & Standard Response (Light Hazard) General Description

Model ESFR K-factor Dry Type Pendent Sprinklers Early Suppression, Fast Response General Description

Sprinkler Identification Number (SIN) TY4234. Page 1 of 8 APRIL 2012 TFP Technical Services

11.2K * Pendent Extended Coverage, Light and Ordinary Hazard General Description. Model/Sprinkler Identification Numbers (SINs) Technical Data

Model ESFR K-factor Dry Type Pendent Sprinklers Early Suppression, Fast Response General Description

RAPID RESPONSE Series LFII Residential Sprinklers 4.4 K-factor Horizontal Sidewall, Dry Type Wet Pipe and Dry Pipe Systems

5.6K Pendent, Upright, and Horizontal Sidewall Standard Response, Standard Coverage General Description. Model/Sprinkler Identification Numbers (SINs)

Series ELO K-factor Upright and Pendent Sprinklers Standard Response, Standard Coverage General Description

Model WS TM 5.6 K-factor Specific Application Window Sprinklers, Horizontal and Pendent Vertical Sidewall General Description

Series LFII Residential Horizontal Sidewall Sprinklers 4.2 K-factor General Description

Series LFII Residential Horizontal Sidewall Sprinklers 4.4 K-factor General Description

TECHNICAL DATA. * Refer the Approval Charts and Design Criteria on pages 3-5 for culus Listing and FM Approval requirements that must be followed.

ESFR PENDENT SPRINKLER VK510 (K25.2) TECHNICAL DATA

Series TY-B 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General Description

RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Flat-Plate Concealed Pendent Wet Pipe and Dry Pipe Systems General Description

Model/Sprinkler Identification Number (SIN) Technical Data

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

RAPID RESPONSE Series LFII Residential 4.9 K-factor Concealed Pendent Sprinkler Flat Plate, Wet Pipe and Dry Pipe Systems General Description

Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K Upright and Pendent Extended Coverage Light and Ordinary Hazard General Description

Series EC K-factor Extended Coverage (Light Hazard) Pendent and Recessed Pendent Sprinklers General Description

TECHNICAL DATA. * Refer the Approval Chart on page 120c and Design Criteria on page 120d for culus and FM approval requirements that must be followed.

ESFR PENDENT SPRINKLER VK500 (K14.0) TECHNICAL DATA

TECHNICAL DATA OBSOLETE. * Refer the Approval Chart on page 121c and Design Criteria on page 121d for FM approval requirements that must be followed.

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage

Series TY-B 5.6 and 8.0 K-factor Upright and Pendent Intermediate Level Sprinklers Standard Response General Description

Series TY-B 5.6 K-factor Horizontal and Vertical Sidewall Sprinklers Standard Response, Standard Coverage General Description

esfr pendent sprinkler vk510 (k25.2)

Model A Pipe Line Strainer 3, 4, 6, 8 & 10 Inch (DN80, DN100, DN150, DN200 & DN250) 175 psi (12,1 bar) General Description.

Series DS-1 Stainless Steel Dry-Type Sprinklers 5.6K Pendent, HSW, and Extended Coverage HSW Standard and Quick Response General Description

esfr pendent sprinkler vk510 (k25.2)

ESCUTCHEON PLATE SEATING SURFACE. 1-11/16" (42,7 mm) CROSS SECTION

Sprinkler Identification Numbers. TY3351 Horizontal TY3451 Vertical. Technical Data

Sprinkler Identification Numbers

proven to help in the control of residential fires and to improve the chance for occupants to escape or be evacuated. Dry Pipe System Application

TECHNICAL DATA NOTICE

special request FACTORY ASSEMBLED UPRIGHT WITH SCREW FIELD ASSEMBLED MODEL S2 SHIELD (SEE INSTALLATION SECTION) WRENCH FLATS *

O-RING UPRIGHT SHIELD WRENCH FLATS WRENCH FLATS FIGURE 1 SERIES TY-B UPRIGHT (TY3153) AND PENDENT (TY3251) SPRINKLERS

Series EC K-factor Extended Coverage (Light Hazard) Pendent and Recessed Pendent Sprinklers General Description

Model DV-5 Red-E Cabinet 1-1/2 thru 8 Inch (DN40 thru DN200), 250 psi (17,2 bar) Integrated Deluge Fire Protection Package General Description

RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Domed-Plate Concealed Pendent Wet Pipe and Dry Pipe Systems General Description

proven to help in the control of residential fires and to improve the chance for occupants to escape or be evacuated. Dry Pipe System Application

Sprinkler Identification Numbers

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

Model TY-FRFS, TY-FS Special, and TY-FS 57, 80, and 115 K-factor Upright and Pendent Flat Spray Sprinklers General Description

Technical Data Approvals UL Listed and FM Approved. Refer to Tables 1, 2, and 3, as applicable.

Series TY-FRB 5.6 K-factor Horizontal and Vertical Sidewall Sprinklers Quick Response, Standard Coverage General Description

Model CV-1FR Riser Check Valves 2 to 12 Inch (DN50 to DN300) General Description. Installation. Technical Data. Page 1 of 6 OCTOBER 2010 TFP950

Model JL-14 (SIN RA1812) K14.0 (200 metric) Early Suppression Fast Response Sprinkler

Model SW-20 and SW K-factor Extended Coverage Ordinary Hazard Horizontal Sidewall Sprinklers (Standard Response) General Description

RAPID RESPONSE Series LFII Residential Sprinklers 5.8 K-factor Horizontal Sidewall, NFPA 13 Optimized Wet Pipe Systems

Model SW-20 and SW K-factor Extended Coverage Ordinary Hazard Horizontal Sidewall Sprinklers (Standard Response)

ESCUTCHEON PLATE SEATING 3/4" NPT SURFACE. 1-1/2" (38,1 mm) CROSS SECTION PENDENT RECESSED PENDENT

Model TY-FRFS, TY-FS Special, and TY-FS Flat Spray Sprinklers, Upright and Pendent 57, 80, and 115 K-factor General Description

RAPID RESPONSE Series LFII Residential Sprinklers 4.2 K-factor Horizontal Sidewall Wet Pipe and Dry Pipe Systems General Description

WRENCH FLATS NPT 1/2" 7/16" (11,1 mm) NOMINAL MAKE-IN. 1-1/2" (38,1 mm) 2-3/16" (55,6 mm) WRENCH NPT. (12,7 mm) NOMINAL MAKE-IN.

Model DV-5 Red-E Cabinet 1-1/2 thru 8 Inch (DN40 thru DN200), 250 psi (17,2 bar) Integrated Preaction Fire Protection Package General Description

Series TY-B 5.6 K-factor Horizontal and Vertical Sidewall Sprinklers Standard Response, Standard Coverage General Description

Submittal Packages Detailed with Items and Reviewers

Technical Data. Installation

WRENCH FLATS 1/2" NPT. 7/16" (11,1 mm) NOMINAL MAKE-IN CENTERLINE OF WATERWAY ESCUTCHEON PLATE SEATING SURFACE

Page 1 of 8 DECEMBER 2018 TFP408. Worldwide Contacts.

Sprinkler Identification Number. Page 1 of 6 AUGUST 2018 TFP288. Worldwide Contacts.

WRENCH FLATS 1/2" NPT. 7/16" (11,1 mm) NOMINAL MAKE-IN CENTERLINE OF WATERWAY ESCUTCHEON PLATE SEATING SURFACE

RAPID RESPONSE Series LFII Residential Sprinklers 5.6 K-factor Horizontal Sidewall, NFPA 13 Optimized Wet Pipe Systems

* Temperature rating is FIGURE K-FACTOR QUICK RESPONSE SERIES TY-FRB HORIZONTAL SIDEWALL (TY3331) SPRINKLERS

Models BB, SD, HIP, and AP Specific Application Sprinklers for Protecting Attics General Description

RAPID RESPONSE Series LFII Residential Sprinklers 4.2 K-factor Flush Pendent Wet Pipe and Dry Pipe Systems General Description

Full-scale tested, for use in wood truss construction. Listed for specific roof slopes from 4:12 to 12:12.

Model WS Specific Application Window Sprinklers Horizontal and Pendent Vertical Sidewall 5.6 K-factor General Description

RAPID RESPONSE Series LFII Residential Sprinklers 4.2 K-factor Flush Horizontal Sidewall Wet Pipe Systems

Series DS-1 Stainless Steel Dry-Type Sprinklers 5.6K Pendent, HSW, and Extended Coverage HSW Standard and Quick Response General Description

RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Recessed Pendent, Dry Type Wet Pipe and Dry Pipe Systems General Description

RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Recessed Pendent, Dry Type Wet Pipe and Dry Pipe Systems General Description

STORAGE FIRE PROTECTION SPRINKLERS

Transcription:

Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 Email: techserv@tycofp.com Model ESFR-25 Early Suppression, Fast Response Pendent Sprinklers 25.2 K-factor General Description The Tyco Model ESFR-25 Pendent Sprinklers are Early Suppression, Fast Response Sprinklers having a nominal K-factor of 25.2. (Refer to Figure 1.) They are suppression-mode sprinklers that are especially advantageous as a means of eliminating the use of in-rack sprinklers when protecting high-piled storage. The Model ESFR-25 is typically used for the following commodities and storage arrangements: Most encapsulated or non-encapsulated common materials including cartoned, unexpanded plastics Uncartoned (exposed) expanded plastics in accordance with NFPA 13 and FM Global standards Some storage arrangements of rubber tires, roll paper, flammable liquids, aerosols, and automotive components For specific criteria, refer to the tables in this data sheet as well as the applicable design standard. The ESFR-25 provides the system designer with hydraulic and sprinkler placement options not presently available to the traditional ESFR sprinklers having a nominal K-factor of 14.0. In particular, the Model ESFR-25 has been designed to IMPORTANT Always refer to Technical Data Sheet TFP700 for the INSTALLER WARNING that provides cautions with respect to handling and installation of sprinkler systems and components. Improper handling and installation can permanently damage a sprinkler system or its components and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. operate at substantially lower-end head pressures, as compared to ESFR sprinklers having a nominal K-factor of 14.0. This feature offers flexibility when sizing system piping, as well as possibly reducing or eliminating the need for a system fire pump. Also, the Model ESFR-25 permits use of a maximum deflector-to-ceiling distance of 18 inches (460 mm) versus 14 inches (360 mm). Additionally, a storage arrangement of 40 ft. (12,2 m) with a ceiling height of 45 ft. (13,7 m) does not require in-rack sprinklers as do other ESFR sprinklers having a nominal K-factor of 14.0. Applications for the Tyco ESFR Sprinklers are expanding beyond currently recognized installation standards. For information on research fire tests (with flammable liquids and aerosols, for example) that may be acceptable to an Authority Having Jurisdiction, contact the Technical Services department. NOTICE The Model ESFR-25 Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the National Fire Protection Association, in addition to the standards of any authorities having jurisdiction (for example, FM Global). Failure to do so may impair the performance of these devices. Owners are responsible for maintaining their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. In all cases, the appropriate NFPA or FM installation standard must be referenced to ensure applicability and to obtain complete installation guidelines. The general guidelines in this data sheet are not intended to provide complete installation criteria. Model/Sprinkler Identification Numbers (SIN) TY9226 - Pendent K=25.2 TY9226 is a re-designation for C9226, G8441, and S8010. Page 1 of 8 OCTOBER 2009 TFP312

Page 2 of 8 1 7 1" NPT Components: 1 - Frame 2 - Deflector 3 - Compression Screw 4 - Hook 5 - Strut 6 - Link Assembly 7 - Button 8 - Sealing Assembly 9 - Ejection Spring 8 9 6 5 4 3 3-13/16" (96,8 mm) 9/16" (14,3 mm) NOMINAL MAKE-IN WRENCH FLATS 1-13/16" (46,0 mm) THERMAL SENSING ELEMENT 2 2" (50,8 mm) FIGURE 1 MODEL ESFR-25, K=25.2 EARLY SUPPRESSION, FAST RESPONSE PENDENT SPRINKLER TEMPERATURE RATING Technical Data Approvals UL and C-UL Listed FM and VdS Approved LPCB Approved (094b/01 and 007l/01) NYC under MEA 356-01-E Working Pressure 175 psi (12,1 bar) Pipe Thread Connections 1 inch NPT ISO 7-R1 Discharge Coefficient K = 25.2 GPM/psi 1/2 (362,9 LPM/bar 1/2 ) Temperature Ratings 165 F/74 C 214 F/101 C Finish Natural Brass Physical Characteristics Frame........................ Brass Deflector..................... Bronze Compression Screw...... Stainless Steel Hook......................... Monel Strut......................... Monel Link Assembly........... Solder, Nickel Button........................ Brass Sealing Assembly....... Beryllium Nickel with Teflon* Ejection Spring................ Inconel * Registered trademark of DuPont Patents U.S.A. Patent Numbers: 5,829,532 6,059,044 6,336,509 6,502,643 6,868,917 7,165,624 Additional Patents pending Design Criteria The following general guidelines provided for the Tyco Model ESFR-25 Sprinklers can be used for a quick reference. NOTICE The National Fire Protection Association (NFPA) and FM Global (FM) provide installation standards that must be used to properly design an automatic sprinkler system utilizing Early Suppression, Fast Response (ESFR) Sprinklers. The guidelines provided by NFPA and FM may differ. Consequently, the appropriate standard must be used for a given installation. In all cases, the appropriate NFPA or FM installation standard must be referenced to ensure applicability and to obtain complete installation guidelines. The following general guidelines are not intended to provide complete installation criteria. In addition to this data sheet, the following data sheets describe other Tyco ESFR Sprinklers: TFP315 Model ESFR-17 (TY7226), K=16.8 Pendent Sprinkler TFP316 Model ESFR-17 (TY7126), K=16.8 Upright Sprinkler TFP318 Model ESFR-1 (TY6226), K=14.0 Pendent Sprinkler System Type Wet pipe system Roof Construction Unobstructed or obstructed construction; for example, smooth ceiling, bar joists, beam and girder, and so forth. Where the depths of the solid structural members (beams and stem, for example) exceed 12 inches (302 mm), install ESFR Sprinklers in each channel formed by the structural members. Ceiling Slope 2-inch rise for 12-inch run (16.7%) Building Heights, Storage Heights, and Commodity Refer to Table A. Coverage Area 100 ft 2 (9,3 m 2 ) In some cases, the installation standards permit a greater coverage area. Minimum Coverage Area 64 ft 2 (5,8 m 2 ) per NFPA 13/FM 2-2

Page 3 of 8 TABLE 1 COMMODITY SELECTION AND DESIGN CRITERIA OVERVIEW FOR Storage Type NFPA FM Open Frame (that is, no solid shelves) Single, Double, Multiple-Row, or Portable Rack Storage of Class I-IV and Group A or B Plastics Refer to Table 2 and NFPA 13. Refer to Table 2 and FM 2-2 and 8-9 for details. Solid Pile or Palletized Storage of Class I-IV and Group A or B Plastics Refer to Table 3 and NFPA 13. Refer to Table 3 and FM 2-2 and 8-9 for details. Idle Pallet Storage Refer to Table 4 and NFPA 13. Rubber Tire Storage Refer to Table 5 and NFPA 13. Refer to Table 4 and FM 2-2 and 8-9 for details. Refer to Table 5 and FM 2-2 and 8-9 for details. Rolled Paper Storage (Refer to the standard.) 13 8-21 Flammable Liquid Storage (Refer to the standard.) 30 N/A Aerosol Storage (Refer to the standard.) 30B 7-31 Automotive Components in Portable Racks (Control mode only; refer to the standard.) 13 N/A Notes: N/A = Non-Applicable Refer to Tables 2 through 5 in the Design Criteria section. Spacing 12 feet (3,7 m) for building heights up to 30 feet(9,1 m) 10 feet (3,1 m) for building heights greater than 30 feet (9,1 m) Minimum Spacing 8 feet (2,4 m) Minimum Clearance to Commodity 36 inches (914 mm) NFPA 13 Deflector-to-Ceiling Distance 6 to 18 inches (152 to 457 mm) FM 2-2 Consult FM and/or FM Guidelines for allowable deflector-to-ceiling distances as well as thermal sensing elementto-ceiling criteria. Operation The fusible link assembly is comprised of two link halves that are joined together by a thin layer of solder. When the rated temperature is reached, the solder melts and the two link halves separate, activating the sprinkler and flowing water.

Page 4 of 8 TABLE 2 NFPA AND FM DESIGN CRITERIA FOR RACK STORAGE OF Commodity Class I, Class II, Class III, and Class IV Encapsulated or Unencapsulated Cartoned Unexpanded Plastics Uncartoned (Exposed) Unexpanded Plastics Building Height, Storage Height, NFPA Minimum Residual Pressure, psi (bar) FM The number of design sprinklers at listed pressure is 12 unless specified otherwise. 45 (13,7) 40 (12,2) 40 (2,8) 50 (3,4) 40 (12,2) 35 (10,7) 25 (1,7) 40 (2,8) 35 (10,7) 30 (9,1) 20 (1,4) 30 (2,1) 32 (9,7) 25 (7,6) 20(1,4) 30 (2,1) 45 (13,7) 40 (12,2) 40 (2,8) 50 (3,4) 40 (12,2) 35 (10,7) 25 (1,7) 40 (2,8) 35 (10,7) 30 (9,1) 20 (1,4) 30 (2,1) 32 (9,7) 25 (7,6) 20(1,4) 30 (2,1) 45 (13,7) 40 (12,2) N/A 63 (4,3) w/irs 40 (12,2) 35 (10,7) 50 (3,4) 35 (10,7) 30 (9,1) 50 (3,4) 50 (3,4) 32 (9,7) 25 (7,6) 50 (3,4) 50 (3,4) 30 (9,1) 25 (7,6) 50 (3,4) 35 (2.4) 45 (13,5) 40 (12,0) N/A Scheme 8-9A, Note 5 Cartoned Expanded Plastics 40 (12,0) 35 (10,5) N/A 35 (10,5) 30 (9,0) N/A 32 (9,7) 25 (7,6) N/A 30 (9,1) 25 (7,6) N/A 20 (1,4) 45 (13,5) 40 (12,0) N/A Scheme 8-9A, Note 5 Uncartoned (Exposed) Expanded Plastics 40 (12,0) 35 (10,5) N/A 35 (10,5) 30 (9,0) N/A 30 (9,1) 25 (7,6) N/A 25 (7,6) 20 (6,1) N/A 20 @ 75 (5,2) 20 @ 75 (5,2) 30 (2,1) 30 (2,1) Abbreviations: N/A = Non-Applicable; IRS = In-Rack Sprinklers References: NFPA 13, 2007 Edition, Chapter 16, Tables 16.2.3.1 and 16.3.3.1; Chapter 17, Tables 17.2.3.1 and 17.3.3.1 FM Global, June 2009, Property Loss Prevention Data Sheet 8-9, Table 2.3.7.5(a) Notes: The following notes replicate information cited in the Notes 5 and 8 to Table 2.3.7.5(a) of FM Data Sheet 8-9: Note 5: Refer to Section 2.3.7.2 for details concerning Fire Protection Scheme 8-9A. : The indicated design only applies to the Tyco Model TY9226 K25.2 (K360) sprinkler. The design for all other FM Approved K25.2 (K360) sprinklers must be based on the design requirements indicated for the K22.4 (K320) sprinkler based on the same storage and building heights.

Page 5 of 8 TABLE 3 NFPA AND FM DESIGN CRITERIA FOR PALLETIZED AND SOLID PILED STORAGE OF Commodity Class I, Class II, Class III, and Class IV Encapsulated or Unencapsulated Cartoned Unexpanded Plastics Uncartoned (Exposed) Unexpanded Plastics Cartoned Expanded Plastics Uncartoned (Exposed) Expanded Plastics Building Height, Storage Height, NFPA Minimum Residual Pressure, psi (bar) FM The number of design sprinklers at listed pressure is 12 unless specified otherwise. 45 (13,7) 40 (12,2) 40 (2,8) 50 (3,4) 45 (13,7) 35 (10,7) 40 (2,8) 50 (3,4) 40 (12,2) 35 (10,7) 25 (1,7) 40 (2,8) 35 (10,7) 30 (9,1) 20 (1,4) 30 (2,1) 32 (9,7) 25 (7,6) 20 (1,4) 30 (2,1) 45 (13,7) 40 (12,2) 40 (2,8) 50 (3,4) 45 (13,7) 35 (10,7) 40 (2,8) 50 (3,4) 40 (12,2) 35 (10,7) 25 (1,7) 40 (2,8) 35 (10,7) 30 (9,1) 20 (1,4) 30 (2,1) 32 (9,7) 25 (7,6) 20 (1,4) 30 (2,1) 45 (13,7) 40 (12,2) N/A 63 (4,3) 40 (12,2) 35 (10,7) 50 (3,4) 50 (3,5) 35 (10,7) 30 (9,1) 50 (3,4) 50 (3,5) 32 (9,7) 25 (7,6) 50 (3,4) 50 (3,5) 30 (9,1) 25 (7,6) 50 (3,4) 35 (2,4) 45 (13,7) 40 (12,2) N/A Scheme 8-9A, Note 5 40 (12,2) 35 (10,7) N/A 35 (10,7) 30 (9,1) N/A 32 (9,7) 25 (7,6) N/A 30 (9,1) 25 (7,6) N/A 20 (1,4) 45 (13,7) 40 (12,2) N/A Scheme 8-9A, Note 5 40 (12,2) 35 (10,7) N/A 40 (12,2) 25 (7,6) 35 (10,7) 30 (9,1) N/A 35 (10,7) 25 (7,6) 30 (9,1) 25 (7,6) 20 @ 75 (5,2) 20 @ 75 (5,2) 30 (2,1) 25 (7,6) 20 (6,1) 20 (1,4) Abbreviations: N/A = Non-Applicable References: NFPA 13, 2007 Edition, Chapter 14, Table 14.4.1; also, Chapter 15, Table 15.4.1 FM Global, June 2009, Property Loss Prevention Data Sheet 8-9, Table 2.3.7.5(b) Notes: The following notes replicate information cited in the Notes 5 and 8 to Table 2.3.7.5(b) of FM Data Sheet 8-9: Note 5: Refer to Section 2.3.7.2 for details concerning Fire Protection Scheme 8-9A. : The indicated design only applies to the Tyco Model TY9226 K25.2 (K360) sprinkler. The design for all other FM Approved K25.2 (K360) sprinklers must be based on the design requirements indicated for the K22.4 (K320) sprinkler based on the same storage and building heights.

Page 6 of 8 TABLE 4 NFPA AND FM DESIGN CRITERIA FOR IDLE PALLET STORAGE OF Commodity Building Height, Storage Height, NFPA Minimum Residual Pressure, psi (bar) FM The number of design sprinklers at listed pressure is 12 unless specified otherwise. 45 (13,7) 40 (12,2) N/A 63 (4,3) Wood on Floor Plastic on Floor Wood in Rack Plastic in Rack 40 (12,2) 35 (10,7) 25 (1,7) 50 (3,4) 35 (10,7) 30 (9,1) 20 (1,4) 50 (3,4) 30 (9,1) 25 (7,6) 15 (1,0) 35 (2,4) 45 (13,7) 40 (12,2) N/A 63 (4,3) 40 (12,2) 35 (10,7) N/A 50 (3,4) 35 (10,7) 30 (9,1) N/A 50 (3,4) 30 (9,1) 25 (7,6) N/A 35 (2.4) 45 (13,7) 40 (12,2) N/A 63 (4,3) w/ IRS 40 (12,2) 35 (10,7) 25 (1,7) 35 (10,7) 30 (9,1) 20 (1,4) 50 (3,4) 30 (9,1) 25 (7,6) 15 (1,0) 35 (2,4) 45 (13,7) 40 (12,2) N/A 63 (4,3) w/ IRS 40 (12,2) 35 (10,7) N/A 35 (10,7) 30 (9,1) N/A 50 (3,4) 30 (9,1) 25 (7,6) N/A 35 (2,4) Abbreviations: N/A = Non-Applicable; IRS = In-Rack Sprinklers References: NFPA 13, 2007 Edition, Chapter 12, Tables 12.12.1.2 (d) and 12.12.2.1 FM Global, June 2009, Property Loss Prevention Data Sheet 8-9 uses criteria for uncartoned, unexpanded plastics, Table 2.3.7.5(a) for rack scenarios and Table 2.3.7.5(b) for on-floor scenarios. Installation The Tyco Model ESFR-25 Pendent Sprinklers are to be installed in accordance with the following instructions. NOTICE Damage to the fusible Link Assembly during installation can be avoided by handling the sprinkler by the frame arms only (that is, do not apply pressure to the fusible Link Assembly), and by using the appropriate sprinkler wrench. Failure to do so can lead to an unstable link assembly and premature activation of the sprinkler. Damaged sprinklers must be replaced. Obtain a leak-tight 1-inch NPT sprinkler joint by applying a minimum-tomaximum torque of 20 to 30 ft.lbs. (26,8 to 40,2 Nm). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Step 1. Install the ESFR-25 Pendent Sprinkler in the pendent position. Step 2. With pipe-thread sealant applied, hand-tighten the sprinkler into the sprinkler fitting. Do not apply pressure to the Link Assembly, and handle the ESFR-25 Sprinkler only by the Frame arms. Step 3. Wrench-tighten the ESFR- 25 Sprinkler using only the W-Type 1 Sprinkler Wrench (Figure 2) and by fully engaging (seating) the wrench on the sprinkler wrench flats. Step 4. After installation, inspect the Link Assembly of each ESFR-25 Sprinkler for damage. In particular, verify that the Link Assembly and Hook are positioned as illustrated in Figure 1, and that the Link Assembly has not been bent, creased, or forced out of its normal position in any way. Replace damaged sprinklers. WRENCH RECESS "FITTING SIDE" TOWARDS SPRINKLER FITTING FIGURE 2 W-TYPE 1 SPRINKLER WRENCH

Page 7 of 8 TABLE 5 NFPA AND FM DESIGN CRITERIA FOR RUBBER TIRE STORAGE OF Commodity Building Height, Storage Height, NFPA Minimum Residual Pressure, psi (bar) FM The number of design sprinklers at listed pressure is 12 unless specified otherwise. On-Side or On Tread in Palletized Portable Racks, Open Portable Racks, or Fixed Racks without Solid Shelves On-Side in Palletized Portable Racks, Open Portable Racks, or Fixed Racks without Solid Shelves 35 (10,7) 25 (7,6) 25 (1,7) 75 (5,2) Laced Tires in Open Portable Steel Racks 30 (9,1) 25 (7,6) N/A 75 (5,2) On-Side, On-Tread, or Laced in Permanent and Portable Racks with Open Shelves 40 (12,2) 30 (9,1) N/A 75 (5,2) On-Side in Palletized Portable Racks 40 (12,2) 25 (7,6) N/A 75 (5,2) Abbreviations: N/A = Non-Applicable References: NFPA 13, 2007 Edition, Chapter 18, Table 18.4(d) FM Global, January 2009, Property Loss Prevention Data Sheet 8-3, Table 8 Care and Maintenance The Tyco Model ESFR-25 must be maintained and serviced in accordance with the following instructions. NOTICE Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Exercise care to avoid damage before, during, and after installation. Never paint, plate, coat, or otherwise alter automatic sprinklers after they leave the factory. Replace sprinklers that: were modified or over-heated. were damaged by dropping, striking, wrench twisting, wrench slippage, or the like. are leaking or exhibiting visible signs of corrosion. Responsibility lies with the owner for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Association (for example, NFPA 25), in addition to the standards of any authorities having jurisdiction. Contact the installing contractor or sprinkler manufacturer regarding any questions. Automatic sprinkler systems are recommended to be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes.

Page 8 of 8 Limited Warranty Products manufactured by Tyco Fire Suppression & Building Products (TFSBP) are war ranted solely to the original Buyer for ten (10) years against defects in mate rial and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFSBP. No warranty is given for products or com ponents manufactured by companies not affiliated by ownership with TFSBP or for products and components which have been subject to misuse, improper installation, corrosion, or which have not been installed, maintained, modi fied or repaired in accordance with ap plicable Standards of the National Fire Protection Association, and/or the standards of any other Authorities Having Jurisdiction. Materials found by TFSBP to be defective shall be either repaired or replaced, at TFSBP s sole option. TFSBP neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of prod ucts. TFSBP shall not be responsible for sprinkler system design errors or inac curate or incomplete information sup plied by Buyer or Buyer s repre sentatives. In no event shall TFSBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam ages, including but not limited to labor charges, regardless of whether TFSBP was informed about the possibility of such damages, and in no event shall TFSBP s liability exceed an amount equal to the sales price. The foregoing warranty is made in lieu of any and all other warranties, express or implied, including warranties of merchantability and fitness for a particular purpose. This limited warranty sets forth the exclusive remedy for claims based on failure of or defect in products, materials or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full extent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Procedure Contact your local distributor for availability. When placing an order, indicate the full product name. Specify the Sprinkler Identification Number (SIN), quantity, and temperature rating. Refer to the Price List for complete listing of Part Numbers. Sprinkler Assemblies Specify: (temperature rating), natural brass, TY9226 Pendent Sprinkler, P/N (specify). 165 F/74 C............... P/N 58-441-1-165 214 F/101 C.............. P/N 58-441-1-214 Special-Order Sprinkler Assemblies with ISO 7/1 Thread Connections Specify: (temperature rating), natural brass, TY9226 Pendent Sprinkler with thread connection per ISO 7/1, P/N (specify). 165 F/74 C............... P/N 58-442-1-165 214 F/101 C.............. P/N 58-442-1-214 Sprinkler Wrench Specify: W-Type 1 Sprinkler Wrench, P/N 56-872-1-025. 2007-2009 TYCO FIRE SUPPRESSION & BUILDING PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446