Committee Input No. 60-NFPA [ Sections , ]

Similar documents

MEMORANDUM. NFPA Technical Committee on Solvent Extraction Plants. NFPA 36 First Draft TC FINAL Ballot Results (F2016)

Second Revision No. 36-NFPA [ Detail ] Submitter Information Verification. Committee Statement 5/18/2015 1:01 PM

First Revision No. 49-NFPA 17A-2015 [ Detail ] Submitter Information Verification. Committee Statement 7/30/2015 1:35 PM

NFPA 33 Standard for Spray Applica4on Using Flammable or Combus4ble Materials

SEMICONDUCTOR FABRICATION FACILITIES

FLAMMABLE FINISHES CHAPTER 24

CENTRAL STATE HOSPITAL PLAN SAFE USE HANDLING AND STORAGE OF FLAMMABLE AND COMBUSTIBLE LIQUIDS

MEMORANDUM. According to the final ballot results, all ballot items received the necessary affirmative votes to pass ballot.

First Revision No. 1-NFPA [ Chapter 2 ]

SEMICONDUCTOR FABRICATION FACILITIES

Donald E. Major, Report of the Committee on James Murphy, Finishing Processes Kenneth J. Pilat, Steven J. Gunsel, John Schweitzer,

Fire Department HEADQUARTERS Cathedral Oaks Road Santa Barbara, CA (805) FAX: (805) CODE SUMMARY

SEMICONDUCTOR FABRICATION FACILITIES

SEMICONDUCTOR FABRICATION FACILITIES

NFPA 30 FLC-SWC First Revisions Page 1 of 10 11/6/2015 9:21 AM. First Revision No. 208-NFPA [ Section No ]

Second Revision No. 1-NFPA 17A-2016 [ Section No ] Submitter Information Verification. Committee Statement. 1 of 14 6/22/2016 3:15 PM

Second Revision No. 2-NFPA [ Section No ]

Second Revision No. 20-NFPA [ Section No. 1.4 ] Supplemental Information. Submitter Information Verification. Committee Statement


Part I Extraction Process Equipment

First Revision No NFPA [ Section No ]

Above Ground Fuel Tank Requirements

"Spray area" is the term that is used throughout the document. This change is for consistency.

Public Input No. 1-NFPA [ Global Input ] Statement of Problem and Substantiation for Public Input. Submitter Information Verification

9/23/ :20 AM. Second Revision No NFPA [ Section No ] Supplemental Information. Submitter Information Verification

Working safely with flammable liquids

Laboratories and Hazardous Materials. Company Overview

Committee on NFPA 30A

Second Revision No. 3-NFPA [ Section No. 2.3 ]

Second Revision No. 1-NFPA 90A-2016 [ Section No ] Submitter Information Verification. Committee Statement

First Revision No. 1-NFPA 30A-2015 [ Section No ] Supplemental Information. Submitter Information Verification. Committee Statement

First Revision No. 1-NFPA [ Section No ] Submitter Information Verification. Committee Statement 4/15/ :08 AM

First Revision No. 20-NFPA [ Section No ]

Public Input No. 1-NFPA 99B-2015 [ Section No. 2.3 ] Statement of Problem and Substantiation for Public Input. Related Public Inputs for This Document

Public Comment No. 2-NFPA [ Section No ] Statement of Problem and Substantiation for Public Comment. Submitter Information Verification

Second Revision No. 14-NFPA [ Global Comment ] Submitter Information Verification. Committee Statement 8/25/ :39 AM

First Revision No. 15-NFPA [ Chapter 2 ]

(h) Pesticide Application.

Black Diamond Fire Department Building Owner s Responsibilities for Fire Safety Equipment

Special Occupancy Requirements

First Revision No. 2-NFPA [ Global Input ] Submitter Information Verification. Committee Statement. 1 of 11 1/18/2016 5:43 PM

Public Comment No. 13-NFPA [ Section No ]

Flammable and Combustible Liquids Checklist

NFPA 30 FLC-SWC Public Comment Report

Public Input No. 1-NFPA [ Global Input ] Statement of Problem and Substantiation for Public Input. Related Public Inputs for This Document

Flammable Liquids!!!!!

(a) Flame shall not spread to the outer extremities of the sample on the 8 ft 12 ft (2440 mm 3660 mm) wall. Flashover shall not occur.

Winnipeg Fire Department Fire Prevention Branch

Committee Input No. 28-NFPA 13R-2013 [ Global Input ]

Flammable Liquid Storage

Location of Requirements Listed Category I appliances Type B gas vent 12.7 Listed appliances equipped with. Chimney Single wall metal pipe 12.

Committee Input No NFPA [ Global Input ] Submitter Information Verification. Committee Statement. 1 of /20/ :02 AM

2018 IFC Update. Based on the 2018 International Fire Code, (IFC ) Goal. Objectives. Content

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

NFPA 72 is in the same cycle as NFPA 80. The extracted text will be updated with a Second Revision during the second draft meeting.

Public Input No. 52-NFPA [ Section No [Excluding any Sub-Sections] ]

First Revision No. 3-NFPA 51B-2016 [ New Section after 1.5 ] Submitter Information Verification. Committee Statement 11/18/2016 2:25 PM

26 of 128 9/23/2014 9:25 AM

NFPA 86 Commitee Inputs Page 1 of 45

Update all extract references to NFPA documents (including NFPA 72) in Chapter 3 and related annex material to the latest editions.

First Revision No. 6-NFPA [ Section No. 2.2 ]

Committee Input No. 10-NFPA [ Chapter 17 ]

M E M O R A N D U M. NFPA Technical Committee on Water Additives for Fire Control and Vapor Mitigation


M E M O R A N D U M. According to the final ballot results, all ballot items received the necessary affirmative votes to pass ballot.

Fire Prevention Plan Program

M EM O RA N D UM. NFPA 652 First Draft Correlating Committee FINAL Ballot Results (A2018)

Public Input No. 3-NFPA [ Chapter 2 ]

SAF-BCF SECOND REVISIONS WITH STATEMENTS

FIRE SAFETY DURING CONSTRUCTION, ALTERATION AND DEMOLITION

Public Input No. 1-NFPA 90B-2015 [ Chapter 2 ]

MEMORANDUM. According to the final ballot results, all ballot items received the necessary affirmative votes to pass ballot.

First Revision No. 36-NFPA [ Section No. 1.1 [Excluding any Sub-Sections] ]

Second Revision No. 1 NFPA [ Chapter 2 ]

SERIES & NO. SMI SUBJECT: SAFE CONSIDERATIONS FOR AN APPLICATION OF SPECIAL ELECTRICAL SYSTEMS

Committee Input No. 9-NFPA [ Global Input ] Supplemental Information. Submitter Information Verification. Committee Statement

9/20/2016 2:53 PM. Second Revision No NFPA [ Section No ] Supplemental Information. Submitter Information Verification

First Revision No. 158-NFPA [ Global Input ] Submitter Information Verification. Committee Statement

CHAPTER 7 ALTERATIONS LEVEL

State of New Jersey. General Permit. for Degreasing Operations using Non-HAP Volatile Organic Compounds (VOCs)

Correlating Committee on Automatic Sprinkler Systems

1.2 To ensure the safety of all persons working in or occupying a building where a hot work operation is performed.

FUEL. Fire & Flammable Liquids Properties. Flammable & Combustible Liquid Safety. Safety. Practice. Laws: OSHA & NFPA. Safety.

2010 FIRE CODE OF NEW YORK STATE

Second Revision No. 5-NFPA [ Section No ] Supplemental Information. Submitter Information Verification. Committee Statement

Adobe Connect - Invitation to NFPA 385 Second Draft Web Conference

IMC Significant Changes Summary Tier I

Public Input No. 4-NFPA [ Section No. 4.2 ] Statement of Problem and Substantiation for Public Input. Submitter Information Verification

Public Input No. 79-NFPA [ Section No. 1.1 ] Additional Proposed Changes. Statement of Problem and Substantiation for Public Input

Fire Department HEADQUARTERS Cathedral Oaks Road Santa Barbara, CA (805) FAX: (805) CODE SUMMARY

Public Input No. 1-NFPA [ Global Input ] Statement of Problem and Substantiation for Public Input. Related Public Inputs for This Document

Notice on the implementation of the amendments to the FSS Code in resolution MSC.339(91)

Requirements for the protection of High-Piled Combustible Storage (HPCS) Effective Date: January 2011

FEMA Recommendations for Protection of Curtained Limited Finishing Workstations using UL 1254 Listed Pre engineered Dry Chemical Systems


Chapter 18 Welding Table of Contents

Spray Finishing Using Flammable and Combustible Materials -- OSHA Standard Carol J. Lehtola, Charles M. Brown, and William J.

RESOLUTION MSC.339(91) (adopted on 30 November 2012) AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE)

Transcription:

Page 1 of 15 Committee Input No. 60-NFPA 34-2013 [ Sections 3.3.7.1, 3.3.7.2 ] Sections 3.3.7.1, 3.3.7.2 3.3.7.1 Combustible Liquid. A Any liquid that has a closed-cup flash point at or above 100 F (37.8 C). Combustible Liquid Classification. Combustible Liquid Class II., as determined by the test procedures and apparatus set forth in Section 4.4 of NFPA 30. Combustible liquids are classified as Class II or Class III according to Section 4.3 of NFPA 30 as follows: Class II Liquid- Any liquid that has a flash point at or above 100 F (37.8 C) and below 140 F (60 C). Combustible Liquid Class IIIA. Class III Liquid-Any liquid that has a flash point at or above 140 F (60 C). (a) Class IIIA Liquid- Any liquid that has a flash point at or above 140 F (60 C), but below 200 F (93 C). Combustible Liquid (b) Class IIIB. Liquid- Any liquid that has a flash point at or above 200 F (93 C). [30, 2012 ] 3.3.7.2 Flammable Liquid. A Any liquid that has a closed-cup flash point that is below 100 F (37.8 C), as determined by the test procedures and a maximum vapor pressure of 40 psia (2068 mm Hg) at 100 F (37.8 C). Flammable Liquid Classification. Flammable Liquid Class I. Any liquid that has a closed-cup flash point below 100 F (37.8 C) and a Reid vapor pressure not exceeding 40 psia (2068.6 mm Hg) at 100 F (37.8 C). Flammable Liquid Class IA apparatus set forth in Section 4.4 of NFPA 30 and a Reid vapor pressure that does not exceed an absolute pressure of 40 psi (276 kpa) at 100 F(37.8 C) as determined by ASTM D 323, Standard Test Method for Vapor Pressure of Petroleum Products (Reid Method). Flammable Liquids are further subclassified in accordance with the following: (a) Class IA Liquids. Any liquid that has a flash point below 73 F (22.8 C) and a boiling point below 100 F (37.8 C). Flammable Liquid (b) Class IB Liquids. Any liquid that has a flash point below 73 F (22.8 C) and a boiling point at or above 100 F (37.8 C). (c) Flammable Liquid Class IC. Any liquid that has a flash point at or above 73 F (22.8 C), but below 100 F (37.8 C). [ 30, 2012] Submitter Information Verification

Page 2 of 15 Submitter Full Name: Nancy Pearce Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Sun Jun 16 08:22:47 EDT 2013 Committee Statement Committee Statement: Response Message: The committee is planning to extract these definitions from NFPA 30 and will correlate the definitions in NFPA 34 with those in NFPA 33. Ballot Results This item has not been balloted

Page 3 of 15 Committee Input No. 57-NFPA 34-2013 [ Section No. 6.4 ] 6.4 Areas Adjacent to Open Processes. Electrical wiring and electrical utilization equipment located adjacent to open processes shall meet the requirements of 6.4.1 through 6.4.4 and Figure 6.4(a), Figure 6.4(b), Figure 6.4(c), Figure 6.4(d), or Figure 6.4(e), whichever is applicable. Figure 6.4(a) Electrical Area Classification for Open Dipping and Coating Processes Without Vapor Containment or Ventilation. Figure 6.4(b) Electrical Area Classification for Open Dipping and Coating Processes with Peripheral Vapor Containment and Ventilation Vapors Confined to Process Equipment. Figure 6.4(c) Electrical Area Classification for Open Dipping and Coating Processes with Partial Peripheral Vapor Containment and Ventilation Vapors NOT Confined to Process Equipment.

Page 4 of 15 Figure 6.4(d) Electrical Area Classification for Open Dipping and Coating Processes with Partial Peripheral Vapor Containment and Ventilation Vapors Confined to Process Equipment. Figure 6.4(e) Electrical Area Classification for a Typical Printing Process. 6.4.1 Electrical wiring and electrical utilization equipment located in any sump, pit, or belowgrade channel that is within 7620 mm (25 ft) horizontally of a vapor source, as defined by this standard, shall be suitable for Class I, Division 1 or Class I, Zone 1 locations. If the sump, pit, or channel extends beyond 7620 mm (25 ft) of the vapor source, it shall be provided with a vapor stop, or it shall be classified as Class I, Division 1 or Class I, Zone 1 for its entire length. 6.4.2

Page 5 of 15 Electrical wiring and electrical utilization equipment located within 1525 mm (5 ft) of a vapor source shall be suitable for Class I, Division 1 or Class I, Zone 1 locations. The space inside a dip tank, ink fountain, ink reservoir, or ink tank shall be classified as Class I, Division 1 or Class I, Zone 0, whichever is applicable. 6.4.3 Electrical wiring and electrical utilization equipment located within of the Class I, Division 1 or Class I, Zone 1 location described in 6.4.2 shall be suitable for Class I, Division 2 or Class I, Zone 2 locations, whichever is applicable. 6.4.4 The space above the floor and extending 6100 mm (20 ft) horizontally in all directions from the Class I, Division 1 or Class I, Zone 1 location described in 6.4.3 shall be classified as Class I, Division 2 or Class I, Zone 2, and electrical wiring and electrical utilization equipment located within this space shall be suitable for Class I, Division 2 or Class I, Zone 2 locations, whichever is applicable. Exception : This space shall be permitted to be nonclassified for purposes of electrical installations if the surface area of the vapor source does not exceed 0.5 m 2 (5 ft 2 ), the contents of the dip tank, ink fountain, ink reservoir, or ink tank do not exceed 19 L (5 gal), and the vapor concentration during operating and shutdown periods does not exceed 25 percent of the lower flammable limit. Supplemental Information File Name Open 34FCf06-4a_version1.pdf Open 34FCf06-4a_version2.pdf Open 34FCf06-4b.pdf Open 34FCf06-4d.pdf Open 34FCf06-4e.pdf Open Description Submitter Information Verification Submitter Full Name: [ Not Specified ] Organization: [ Not Specified ] Street Address: City: State: Zip: Submittal Date: Wed Jun 05 12:52:16 EDT 2013 Committee Statement

Conveyor rail 1525 mm (5 ft) 1525 mm (5 ft) Point beyond which object is no longer a vapor source 1525 mm (5 ft) Pit Class I, Division 1 or Zone 0 Class I, Division 1 or Zone 1 Class I, Division 2 or Zone 2 Diptank Drainboard 1525 mm 1525 mm 6100 mm (20 ft) 1525 mm (5 ft) (5 ft) 6100 mm (20 ft) (5 ft) Floor

Conveyor rail 1525 mm (5 ft) 1525 mm (5 ft) Point beyond which object is no longer a vapor source 1525 mm (5 ft) Pit Class I, Division 1 or Zone 0 Class I, Division 1 or Zone 1 Class I, Division 2 or Zone 2 Diptank Drainboard 1525 mm 1525 mm 6100 mm (20 ft) 1525 mm (5 ft) (5 ft) 6100 mm (20 ft) (5 ft) Floor

Peripheral vapor ventilation Saturated vapor blanket Exhaust plenum Vaporcondensing coils Liquid Vapor containment Ventilation inlet at floor level Class I, Division 1 or Zone 0 Class I, Division 1 or Zone 1 Class I, Division 2 or Zone 2 Pit Definitions Freeboard: The distance from the maximum solvent or coating material level to the top of the tank Freeboard ratio: The freeboard height divided by the smaller of the interior length or interior width of the tank

Exhaust duct 610 mm (2 ft) Liquid Pit Class I, Division 1 or Zone 0 Class I, Division 1 or Zone 1 Class I, Division 2 or Zone 2

1525 mm (5 ft) 6100 mm (20 ft) Class I, Division 1 or Zone 0 Class I, Division 1 or Zone 1 Class I, Division 2 or Zone 2 1525 mm (5 ft)

Page 6 of 15 Committee Statement: Response Message: The Committee is considering revising the existing drawings to make clarify the electrical classifications. Some of the proposed changes include removal of hard lines between classified areas. The Committee is soliciting input and will make changes based on input at the second draft meeting. Ballot Results This item has not been balloted

Page 7 of 15 Committee Input No. 59-NFPA 34-2013 [ Section No. 6.5 [Excluding any Sub-Sections] ] Areas adjacent to enclosed dipping and coating processes shall be classified in accordance with 6.5.1, 6.5.2, and Figure 6.5. Figure 6.5 Electrical Area Classification Around Enclosed Dipping and Coating Processes. Supplemental Information File Name Description 34FCf06-5_version1.pdf Version 1 34FCf06-5_version2.pdf Version 2 Submitter Information Verification Submitter Full Name: Nancy Pearce Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Fri Jun 14 22:31:45 EDT 2013 Committee Statement Committee Statement: Response Message: Committee is considering revising this diagram to one of the two options attached to clarify the requirements in the standard. Ballot Results This item has not been balloted

Conveyor rail Vestibule Enclosed vapor/drain tunnel Vapor confined to enclosed tunnel Oven Drainboard Vapor space Classification of interior of oven governed by NFPA 86 Class I, Division 1 or Zone 0 Class I, Division 1 or Zone 1 Class I, Division 2 or Zone 2

Conveyor rail Vestibule Enclosed vapor/drain tunnel Vapor confined to enclosed tunnel Oven Drainboard Vapor space Classification of interior of oven governed by NFPA 86 Class I, Division 1 or Zone 0 Class I, Division 1 or Zone 1 Class I, Division 2 or Zone 2

Page 8 of 15 Committee Input No. 9-NFPA 34-2013 [ Section No. 9.3.1 ] 9.3. 1 1 Processes shall be protected with any of the following approved automatic fire protection systems: (1) (2) A foam extinguishing system that meets the requirements of NFPA 11, Standard for Low-, Medium-, and High-Expansion Foam (See also 9.3.2.) (3) * A water spray extinguishing system that meets the requirements of NFPA 15, Standard for Water Spray Fixed Systems for Fire Protection * A carbon dioxide system that meets the requirements of NFPA 12, Standard on Carbon Dioxide Extinguishing Systems (4) A dry chemical extinguishing system that meets the requirements of NFPA 17, Standard for Dry Chemical Extinguishing Systems (5) A gaseous agent extinguishing system that meets the requirements of NFPA 2001, Standard on Clean Agent Fire Extinguishing Systems (6) A water mist or hybrid water mist fire protection system that meets the applicable requirements of NFPA 750, Standard on Water Mist Fire Protection Systems (7) For tanks containing liquids having flash points above 93 C (200 F) and for associated process hazards, a sprinkler system that meets the requirements of NFPA 13, Standard for the Installation of Sprinkler Systems (8) For tanks equipped with a tank cover arranged to close automatically in the event of fire, a sprinkler system that meets the requirements of NFPA 13, Standard for the Installation of Sprinkler Systems Submitter Information Verification

Page 9 of 15 Submitter Full Name: [ Not Specified ] Organization: [ Not Specified ] Street Address: City: State: Zip: Submittal Date: Fri Mar 22 17:12:15 EDT 2013 Committee Statement Committee Statement: NFPA 750 is currently under revision. The Committee is considering adding water mist and hybrid water mist fire protection systems into applicable sections of NFPA 34 however there are several concerns that should be addressed. Water mist systems are currently not listed for use in dipping, coating and printing processes using flammable or combustible liquids. The committee also decided there was a potential conflict with NFPA 750 and the term "hybrid water mist" as suggested in public inputs 35, 36,37, 38 and 40. Response Message: Public Input No. 36-NFPA 34-2013 [Section No. 9.3.1] Ballot Results This item has not been balloted

Page 10 of 15 Committee Input No. 11-NFPA 34-2013 [ Section No. 9.10 ] 9. 10 Specific 10 Specific Requirements for Water-Based Fire Protection Systems. shall Water-based fire protection systems, including automatic sprinkler, water mist, water spray, and hybrid water mist fire protection systems, shall be designed to allow drainage of water without raising the level of the coating material to the overflow level. Submitter Information Verification Submitter Full Name: [ Not Specified ] Organization: [ Not Specified ] Street Address: City: State: Zip: Submittal Date: Fri Mar 22 17:31:26 EDT 2013 Committee Statement Committee Statement: NFPA 750 is currently under revision. The Committee is considering adding water mist and hybrid water mist fire protection systems into applicable sections of NFPA 34 however there are several concerns that should be addressed. Water mist systems are currently not listed for use in dipping, coating and printing processes using flammable or combustible liquids. The committee also decided there was a potential conflict with NFPA 750 and the term "hybrid water mist" as suggested in public inputs 35, 36,37, 38 and 40. Response Message: Public Input No. 38-NFPA 34-2013 [Section No. 9.10] Ballot Results This item has not been balloted

Page 11 of 15 Committee Input No. 10-NFPA 34-2013 [ Section No. 9.11.1.1 ] 9.11.1.1 * Automatic sprinkler protection shall be provided for the following areas: (1) All printing process areas that contain ordinary combustibles, flammable or combustible liquids, or combustible construction (2) All printing operations areas, at the ceiling level (3) Areas of printing presses that are shielded from ceiling sprinklers and where combustibles exist Exception : Where carbon dioxide protection is (1), water mist, and hybrid water mist fire protection systems are provided for such areas, sprinklers are not required. Submitter Information Verification Submitter Full Name: [ Not Specified ] Organization: [ Not Specified ] Street Address: City: State: Zip: Submittal Date: Fri Mar 22 17:30:38 EDT 2013 Committee Statement

Page 12 of 15 Committee Statement: NFPA 750 is currently under revision. The Committee is considering adding water mist and hybrid water mist fire protection systems into applicable sections of NFPA 34 however there are several concerns that should be addressed. Water mist systems are currently not listed for use in dipping, coating and printing processes using flammable or combustible liquids. The committee also decided there was a potential conflict with NFPA 750 and the term "hybrid water mist" as suggested in public inputs 35, 36,37, 38 and 40. Response Message: Public Input No. 37-NFPA 34-2013 [Section No. 9.11.1.1] Ballot Results This item has not been balloted

Page 13 of 15 Committee Input No. 53-NFPA 34-2013 [ Chapter 11 ] Chapter 11 Electrostatic Detearing Apparatus 11.1 Scope. Chapter 11 shall apply to any dipping or coating process that incorporates electrostatic detearing systems to remove excess coating material. 11.2 General. 11.2.1 Electrostatic detearing equipment shall meet the requirements of Chapter 1 through Chapter 10, except as hereinafter modified, and shall also meet the requirements of this chapter. 11.2.2 Electrostatic apparatus and devices used in connection with paint detearing operations shall be listed or approved. 11.3 Requirements for Electrical System and Components. 11.3.1 Transformers, high voltage supplies, control apparatus, and all other electrical portions of the equipment, with the exception of high voltage grids and their connections, shall be located outside the vapor area defined in 3.3.13 or shall meet the requirements of Chapter 6. 11.3.2 Electrodes shall be supported and shall be insulated from ground. 11.3.3 High voltage leads to electrodes shall be supported on insulators and shall be guarded against accidental contact or grounding. Insulators shall be kept clean and dry. 11.3.4 A separation of at least twice the sparking distance shall be maintained between the object or material being deteared and the electrodes or conductors. A sign indicating this separation distance shall be conspicuously posted near the assembly. 11.4 Support of Workpieces. 11.4.1 Workpieces or material being deteared shall be supported on conveyors or hangers. 11.4.2 * The conveyor shall be arranged to ensure that the workpieces or material being deteared is electrically connected to ground with a resistance of not more than 10 6 ohms (1 megohm) and that the distance required by 11.3.4 is maintained between the workpiece or material and the electrodes at all times. 11.4.3 Workpieces or material being deteared shall be supported to prevent swinging or movement that would reduce the distance to less than that required. 11.5 Manual Operations. Electrostatic detearing shall not be used where the workpieces or material being deteared is manipulated by hand. 11.6 Electrical Safety Requirements.

Page 14 of 15 Electrostatic apparatus shall be equipped with automatic means that will deenergize and ground the high voltage elements and signal the operator under any of the following conditions: (1) Stopping of ventilating fans or failure of ventilating equipment from any cause (2) Stopping of the conveyor carrying the objects or material through the high voltage field (3) Occurrence of a ground fault or excessive current leakage at any point on the high voltage system (4) Reduction of clearances to below that specified in 11.3.4 (5) De-energizing of the primary side of the power supply 11.7 Personnel Safety. Safeguards such as enclosures, fencing, railings, or other means shall be placed about the equipment or incorporated therein to ensure that isolation of the process is maintained from plant storage or personnel. 11.8 * Grounding Requirements. All electrically conductive objects in the process area, except those objects required by the process to be at high voltage, shall be electrically connected to ground with a resistance of not more than 10 6 ohms (1 megohm). 11.8.1 This requirement shall apply to paint containers, wash cans, guards, and any other electrically conductive objects or devices in the area. 11.8.2 This requirement also shall apply to any personnel in the process area. 11.8.3 The equipment shall carry a prominent, permanently installed warning regarding the necessity for this grounding feature. 11.9 Signs. Signs that designate the process zone as dangerous in regard to fire and accident and that meet the requirements of ANSI Z535, Safety Signs Series IS, shall be conspicuously posted. 11.10 Drip Plates and Screens. Drip plates and screens subject to deposits of coating material shall be cleaned regularly to prevent excess accumulation of residues. Submitter Information Verification Submitter Full Name: [ Not Specified ] Organization: [ Not Specified ] Street Address: City: State: Zip: Submittal Date: Tue Jun 04 14:56:54 EDT 2013 Committee Statement

Page 15 of 15 Committee Statement: Response Message: The Committee is proposing to delete this chapter because there is a general consensus within the industry that this technology is no longer used. However before this chapter is removed, the Committee is asking the industry to provide input on whether or not the technology is still in use. This process has historically been the source of a number of fires and the Committee does not want to delete the chapter if this technology is still being used. Note that 6.2.5 (2) would need to be deleted if this Committee input becomes a first revision at the second draft meeting. Ballot Results This item has not been balloted