Operating Instructions RM 90. Watch Cleaning Machine. english

Similar documents
Operating Instructions

Operating Instructions

Super Elite Watch cleaning machine

Operating Instructions

Operating Instructions

Operating Instruction

Operating Instructions

Operating Instructions

Elmasonic S Ultrasonic cleaning units. The sum of all possibilities

+ English + 1. Safety warnings

Operating Instructions

Vmusbtpojd!dmfbojoh!xjui!tubuf.pg.uif.bsu!ufdiopmphz

Instruction Manual Suppository Penetration Tester. Type PM 30

Elmaflame 300. Hydrogen Soldering and Welding Unit. product profile. Elma Order No. Technical data

Operating Instructions

Operating Instructions. Accessory Units Melitta Cafina XT Series. Melitta Professional Coffee Solutions

Operating Instructions!

ENGLISH (Original instructions) INSTRUCTION MANUAL. Demolition Hammer HM0810TA DOUBLE INSULATION. IMPORTANT: Read Before Using.

User Manual GV25 GV35 GV702. Company information: Original instructions GV12066 (1)

Table of Contents. English

SMHA Hatch High temperature fan HT-fan Installation and Maintenance

USER S MANUAL ATH WH220

ENGLISH (Original instructions) INSTRUCTION MANUAL. Power Mixer UT2204 DOUBLE INSULATION. IMPORTANT: Read Before Using.

Instructions For Use ENG. LED Magnifier Lamp

Operating Instructions

Inspection Light LED 6149/2. Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

1.0 INTRODUCTION 3 TABLE OF CONTENTS 2.0 FOR YOUR SAFETY Warnings and Safety Advice Coolants WARRANTY AND 3 CUSTOMER SERVICE 4.0 INS

SCHMIDT Flow Sensor SS Ex - Supplementary instructions for use in explosive atmospheres ATEX

235L G. Original-Gebrauchsanleitung V1/1115

Read these instructions before using and keep them available at all times!

Automatic Milk Frother / Milchschäumer

Tornado Operations & Maintenance Manual

HELMUT KÄMPKEN GMBH OPERATING MANUAL

OPERATION AND MONTAGE MANUAL ROOF FANS

Installation manual surface mounting plugs and socket outlets, panel mounting plugs and socket outlets with screw connection (16/32 A)

PRESSURE WASHER MODEL NO: JETSTAR 1750 OPERATION & MAINTENANCE INSTRUCTIONS. WARNING Read the instructions before using the machine PART NO:

51AKS I S O OWNER S MANUAL

OPERATION AND MONTAGE MANUAL ROOF FANS

Installation manual surface mounting plugs and socket outlets, panel mounting plugs and socket outlets QUICK-CONNECT (63 A)

ATD /8 Electric Drill

SOLDERING GUN PLP 100 A1

Blower UB1100 UB1101 INSTRUCTION MANUAL

51AKB / 51 AKC OWNER S MANUAL

Instructions for installation and use English. More documents on: H B /09

Health & Safety and Installation guide

User Manual FANG 18 C. Company information: Original instructions 80188EU (1)

Operating instructions

HOT WASHER MODEL NO: KING150

Product Manual Glue Applicators MS 80 and MS 200

RESISTENT EXTRA 3592, 3602 RESISTENT EXTRA PLUS 3592P, 3602P

COMBY 4000 & 9000 STEAM CLEANER OPERATOR MANUAL

PLS 30 SOLDERING GUN WITH HOLDER. Operation and Safety Notes

Installation manual extra-low-voltage socket outlets for panel- and surface-mounting

L / -014L / -015L

ORIGINAL INSTRUCTIONS

Read these instructions before using and keep them available at all times!

Greiner Vibrograf AG Mittelstrasse Langenthal Switzerland. Manual ACS 900. English. Version 20-16

Flow switch. Operating Manual. English manual page Page 1 of 15 Fax:

Millo / Millo pro. Nr x000 / 1805-x000. Ideen für die Dentaltechnik A

DS English... 5 Français Español CONSUMO DE ENERGIA. 1. En Operación: 287,82 Wh 2. En Modo de Espera: N/A Modelo: DS 5.

INSTRUCTIONS CertoClav EL

Sip Vacuum Cleaner 1400/35 Wet & Dry

K 2 Basic. Operating Instructions. Please read the operating instructions carefully before using the unit (05/17)

BEFORE USING THE DISHWASHER/CONNECTIONS

User Instruction Manual

43 May cause sensitisation by skin contact. 67 Vapours may cause drowsiness and dizziness.

TIH 300 S / TIH 400 S / TIH 500 S / TIH 700 S / TIH 900 S / TIH 1100 S

FD 430 Envelope Sealer

OPERATING MANUAL ORWAK March 2005 PUBL. NO Edition 4

Montageanleitung RLO (Original) Mounting Instructions RLO (Translation of the original)

Health & Safety, Use & Care and Installation guide. Οδηγ ς Υγείας, και Ασφάλειας, Χρήσης και Συντήρησης

Ropox Bathtub. Keep this manual with the product at all times! User Manual & Mounting Instructions PDF 6128 /

Operational Instructions. Glue Applicator MS Translation from German to English

K Operating Instructions. Before first use of the unit read these operating instructions and act in accordance with them.

Pneumatic agitator A MAN R

JUMBO INDIRECT FIRED DIESEL HEATER OPERATING INSTRUCTIONS

IDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80

TTK 75 ECO OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK75ECO-TC-002-EN

Operating instructions Page 12. Wine storage cabinet WKt

English CNA-CNB. Centrifugal fans Installation and maintenance

WELCOME IMPORTANT SAFEGUARDS

HULME MARTIN HEAT SEALERS

Installation manual plugs and connectors QUICK-CONNECT (63 A)

Drywall Screwdriver INSTRUCTION MANUAL

Glue Gun 25W TTB580HTL. Barcode: WARNING: Read the instructions before using the product!

HULME MARTIN HEAT SEALERS

Installation and Operating Instructions DÜRR Regeneration Unit for X-ray developers XR 24, XR24 II, XR 24 Nova, XR 24 Pro

2 IN 1 SUBMERSIBLE PUMP

Drywall Screwdriver R INSTRUCTION MANUAL

Kyung Dong Oil Boiler. Contents. 1. General Warnings Safety Warnings

OPERATING INSTRUCTIONS. HELIOS SAFE INDUSTRY ATEX 1500 Watt COD. EHSAFE Watt COD. EHSAFE20

Specifications. Vacuum motor power consumption(w/hp) 1200 / 1.6. Exhaust water pump power consumption(w/hp 800 / 1.1

ENGLISH (Original instructions) INSTRUCTION MANUAL. Random Orbit Sander BO5020 BO5021 DOUBLE INSULATION. IMPORTANT: Read Before Using.

IR Speed Dome. Quick Guide UD.6L0201B1357A01

AIRGOCLEAN 10 E OPERATING MANUAL AIR CLEANER TRT-BA-AIRGOCLEAN10E-TC-001-EN

ENGLISH (Original instructions) INSTRUCTION MANUAL. Belt Sander DOUBLE INSULATION. IMPORTANT: Read Before Using.

INSTRUCTIONS AND WARRANTY

HEA USER MANUAL. 1 Version: 22. June 2010

Grain crusher Universal. Purpose: This machine is designed for the crushing of grain in agricultural operation.

DIRTY WATER SUBMERSIBLE PUMP

Transcription:

ENGLISH Operating Instructions RM 90 Watch Cleaning Machine english Elma GmbH & Co KG Kolpingstr. 1-7 D-78224 Singen Tel. +49 (0) 7731 / 882-0 Fax +49 (0) 7731 / 882-266 info@elma-germany.com www.elma-germany.com

Content 1 General... 3 2 Important safety warnings... 3 3 Initial Preparation... 4 4 Operation... 5 4.1 How to fill the glass beakers and replace the liquids...5 4.2 Cleaning of assembled watch works by counter- current procedure...6 4.3 Cleaning of disassembled watch works in the basket..6 4.4 Cleaning of assembled watches in vibration basket...6 4.5 Interrupt...7 4.6 Start-up of the machine...7 4.7 Cleaning of assembled and disassembled watch- works in Elma cleaning machines...8 4.8 Regulations on Elma cleaning chemicals...9 5 Maintenance... 11 6 Repairs... 11 7 Technical Data... 11 7.1 CE conformity...11 8 Accessories... 12 9 Putting out of action and waste disposal... 12 10 Manufacturer's contact address... 12 2 BA/RM90/GB/06404 Elma GmbH & Co KG

ENGLISH General 1 General The present Operating Instructions are part of the delivered equipment. They must be ready for use at any time and remain with the unit in case of resale. Carefully read the Operating Instructions before use of the unit and operate the electrical appliance according to the instructions. We reserve the right to carry out technical modifications on the unit due to advanced development. Reprints, translations and copying of any kind, including of parts of the document, must be authorized by the editor. The copy right remains with the editor. 2 Important safety warnings Read before initial operation! Intended use Check for damages Mains connection Placement Prevention of electrical accidents Cleaning liquid The watch cleaning machine RM 90 has been designed for the cleaning of mechanical watch works, both assembled and disassembled. Always follow the instructions concerning cleaning procedure and cleaning chemicals as given in Chapter 4 "Operation". Check unit and mains cable for transport damages. In case of visible damages do not put the unit into operation. For safety reasons, the present unit must be connected to a correctly grounded socket only. The technical details indicated on the nameplate must correspond with the available mains connection details, in particular those of the mains voltage and current connected value. Place the unit at a dry and sufficiently ventilated workplace. Keep the workplace, housing and operating elements dry. Protect the unit from entering humidity! The unit must be opened by authorized specialized personnel only. For purposes of maintenance and care of the unit, in case of suspected humidity inside the unit or in case of malfunctions and after operation pull the mains plug. Risk of fire and explosion! The manufacturer, refuse all warranty claims for damage due to the use of corrosive cleaning chemicals or flammable and explosive rinsing media such as petroleum ether, benzine, Toluol, etc.: Liquids see Chapters 4.7 and 4.8. Elma GmbH & Co KG BA/RM90/GB/0404 3

Initial Preparation 3 Initial Preparation Carry out the following steps before taking the machine into operation: 1. Remove the two foamed plastic strips between the centre column and the metal screen. 2. Remove the plastic protective cover from the centre column (zip fastener / snap fastener). Important: Lubricate the centre column to secure smooth lifting. 3. Put back unhinged and tape-fixed lifting rod. 4. Remove the tape strips from the glass covers. 5. Put in the back plate and fasten it with screws. 6. When preparing the machine for operation, ensure to tighten all fastening screws on baskets and holders to prevent pieces from being hurled out and damaged. The machine is equipped with a safety switch at the plexi-glass pane, which does not allow the machine to be put into operation with open pane. If you find that the machine can be operated with open pane, please return the machine to the manufacturer for repair immediately. Otherwise operation of the machine presents a serious risk. 4 BA/RM90/GB/0404 Elma GmbH & Co KG

ENGLISH Operation 4 Operation 1 2 3 4 5 6 ROT a b c 1 OFF VIB m d 15 3 START l k i h g e f 13 11 9 7 5 RM 90 Elma R 4.1 How to fill the glass beakers and replace the liquids Remove the watch work holder from the basket support; pull down the plexi-glass pane; push up the switch (1) to the tilted glass symbol. Switch down the start button (2) for approx. 1 second, the turning disk with the beakers is turned by 90 degrees and the basket support stops at the end position above the first beaker. The beaker can now be taken out, filled and replaced in the machine. For replacement of the other beakers, switch down the start button again for 1 second each, so that the basket support above each beaker and above the heating duct is placed in end position. Liquids see Chapters 4.7 and 4.8. Risk of fire and explosion! CAUTION The manufacturer, refuse all warranty claims for damage due to the use of corrosive cleaning chemicals or flammable and explosive rinsing media such as petroleum ether, benzine, Toluol, etc Liquids see Chapters 4.7 and 4.8. Elma GmbH & Co KG BA/RM90/GB/0404 5

Operation 4.2 Cleaning of assembled watch works by counter- current procedure Control positions Take the watch work holder off the basket support; clamp the watch works in the work holders and fasten the watch work holder to the basket support of the machine. With this cleaning procedure, the right-handed/left-handed rotation of the cleaning motor alternates constantly at very short intervals of 1/15 second up to 1/2 second at control position (3) a-c. Note: With this procedure, watch works with a diameter of up to 28 mm can be cleaned. Operating mode switch (2): VIB position Intensity control (3): a-c position 4.3 Cleaning of disassembled watch works in the basket Control positions Basket order no.: 3000101101 Remove the inserts from the basket, place the watch work pieces in the sections of the inserts and fasten the basket with inserts at the basket support of the machine. Select the rotating speed of the cleaning basket by means of the intensity control switch (3) after operating start in the first cleaning bath so that the basket support does not suck air bubbles into the liquid, as this will diminish the cleaning effect considerably and will cause the forming of foam with alkaline cleaning solutions. The cleaning motor with the basket support fixed to the motor shaft changes the sense of rotation at intervals of 5 seconds. Operating mode switch (2): ROT position Intensity control (3): control speed between a-k 4.4 Cleaning of assembled watches in vibration basket Order no.: 3460000001 VK/1 for 3 watches or 3460000002 VK/2 for 6 watches Remove the basket support from the shaft by loosening the headless screw. Fix the vibration basket to the free shaft end. Take the work holder from the vibration basket, charge it with watch works and reinsert it. For cleaning with vibration basket, there are two available programmes: 6 BA/RM90/GB/0404 Elma GmbH & Co KG

ENGLISH Operation ROTATION Control positions VIBRATION Control positions The vibration basket changes sense of rotation every 5 seconds Operating mode switch (2): ROT position Intensity control (3): m position (full motor speed) The change of sense of rotation of the vibration basket is variable between 1/2 second up to a maximum of 6 seconds. Operating mode switch (2): VIB position Intensity control (3): c-m position 4.5 Interrupt The switch (1) can be used as interrupting switch. In medium position, between the two glass symbols, the switch interrupts the current supply to the machine and the automatic cleaning process of the machine can be interrupted at any stage. 4.6 Start-up of the machine Turn the intensity control (3) to the left as far as it will go (minimum of the range of intensity). The marking on the control switch now points to the letter (a). Now press the start button (2) down for approx. 1 second; the automatic operation of the machine is started, the yellow control lamp (4) is turned on. As soon as the basket or work holder is immersed in the liquid of the first bath, select the required cleaning programme at the operating mode switch (2) and the intensity control (3). For information on the programming by means of the two switches (2) and (3) and the different cleaning procedures please see Chapters 4.2 to 4.4, or the list of settings on the front of the machine. After each new start check the setting of the operation mode switch (2) and the intensity control (3). The programmed cleaning, rinsing and heating periods are 2.5 minutes each, the intermediate spinning period is 30 seconds. The cleaning period in the first beaker can be extended by max. 15 minutes by means of the timer (6). As soon as the basket or the work holder has finished the cleaning bath and the two rinsing baths, the drying process is started. During this process the red control lamp (5) is turned on in addition to the yellow control lamp. When the heating process is finished, the basket is lifted above the heating duct and the machine automatically switches off; both the yellow (4) and the red (5) control lamp are turned out. The heating for the drying of the watch works is controlled thermostatically. The drying temperature is set at approx. 50 C. Now the basket or the watch work holder can be taken out of the machine, the cleaning process is finished. Elma GmbH & Co KG BA/RM90/GB/0404 7

Operation Risk of burning! CAUTION Parts of the cleaning basket and the cleaned items can be very hot after the cleaning process has been finished. Allow sufficient cooling time. Do not reach in the heating tube. 4.7 Cleaning of assembled and disassembled watch- works in Elma cleaning machines For the cleaning of mechanical watch works in Elma cleaning machines you can use Elma cleaning chemicals, both aqueous and non-aqueous. The cleaning of assembled watch works is completely waterfree. Table 1 Disassembled watch works are first cleaned in an aqueous cleaning liquid, then rinsed and finally dried with the specially designed water displacing liquid Suprol Spezial. Cleaning chemicals suitable for use in Elma cleaning machines Standard, Super-Elite, RM80 and RM90: 1. Beaker Cleaning 2. Beaker 1. Rinsing 3. Beaker 2. Rinsing Water-free - assembled watch works cleaning solution elma reinigungslösung wf * water-free intensive cleaning * CKW-free Suprol Spezial * water-free high-purity rinsing Unimix * final rinsing including relubrication (If relubrication is not required, carry out 2. rinsing process with Suprol Spezial.) Aqueous - disassembled watch works cleaning concentrate elma reinigungskonzentrat 1:9 * aqueous/highly efficient concentrate * strong brightening effect Distilled or deionised water Suprol Spezial * water displacing * quick-drying (Suprol floats on the surface in the beaker and can be decanted easily.) 8 BA/RM90/GB/0404 Elma GmbH & Co KG

ENGLISH Operation 4.8 Regulations on Elma cleaning chemicals Section 15 of the EC safety data sheets in accordance with directive 91/155 EWG Cleaning chemical elma reinigungslösung wf Regulations Notes concerning product marking The chemical is classified as dangerous substance according to EC and German regulations and accordingly marked. Marking Xn Harmful R phrases Flammable Harmful: May cause pulmonary damage when swallowed. S phrases Keep away from ignition sources --- Do not smoke. Keep out of reach of children. Store at a temperature of 25 C or below. Do not force vomiting when swallowed. Seek medical advice immediately and show packing or label. Keep container sealed. Suprol Spezial Notes concerning product marking The chemical is classified as dangerous substance according to EC and German regulations and accordingly marked. Marking Xn Harmful R phrases 10 Inflammable 65 Harmful: May cause pulmonary damage when swallowed. Elma GmbH & Co KG BA/RM90/GB/0404 9

Operation S phrases 16 Keep away from ignition sources --- Do not smoke. 2 Keep out of reach of children. 47 Store at a temperature of 25 C or below. 62 Do not force vomiting when swallowed. Seek medical advice immediately and show packing or label. Keep container sealed. Unimix Notes concerning product marking The chemical is classified as dangerous substance according to EC and German regulations and accordingly marked. Marking Xn Harmful elma reinigungskonzentrat 1:9 R phrases 10 flammable 65 harmful: May cause pulmonary damage when swallowed. S phases 16 Keep away from ignition sources --- Do not smoke. 2 Keep out of reach of children. 47 Store at a temperature of 25 C or below. Keep container sealed. Notes concerning product marking The product must not be marked according to the EC and German regulations on dangerous substances. S phases 2 Keep out of reach of children. 250 For commercial use only. 26 When coming into contact with the eyes, immediately rinse with water and seek medical advice. 39 wear face mask/goggles. Do not mix with alkalines. 10 BA/RM90/GB/0404 Elma GmbH & Co KG

ENGLISH Maintenance 5 Maintenance We recommend to lubricate the guiding bushing of the sliding bracket above the oil bore in the centre of the bushing; lubricate every approx. 3 months; use several drops of a viscous gear oil (SAE 80). Remove gummy oil residues from the centre column, then relubricate. 6 Repairs Opening by authorized specialized personnel only NOTE Repair and maintenance works which require the unit to be connected and opened must be carried out by authorized and specialized personnel only. Separate the unit from the mains before opening up the housing. The manufacturer cannot be held responsible for any damage caused by unauthorized repair works. In case of damage please contact the manufacturer or your supplier. 7 Technical Data Mains voltage (as per version) (Vac) 100-120 or 220-240 Mains frequency 50 / 60 Power consumption (W) 115 External measurements w / d / h (mm) 350 / 350 / 640 Weight (Kg) 27,6 Material of housing Steel sheet painted 7.1 CE conformity The present unit is in compliance with the CE marking criteria. The declaration of conformity is available from the manufacturer. Elma GmbH & Co KG BA/RM90/GB/0404 11

Accessories 8 Accessories Movement holder for 6 movements 300 000 6038 Strainer basket for divided clockworks 300 010 1101 9 Putting out of action and waste disposal The unit can be taken to metal and electronics recycling stations or returned to the manufacturer. 10 Manufacturer's contact address Elma Hans Schmidbauer GmbH & Co. KG Kolpingstr. 1-7, D-78224 Singen Phone +49 (0) 7731 / 882-0 Fax +49 (0) 7731 / 882-266 e-mail: info@elma-germany.com Homepage: www.elma-germany.com Technical support Phone +49 (0) 7731 / 882-280 Fax +49 (0) 7731 / 882-253 e-mail: support@elma-germany.com Technical and optical changes reserved_elma_ch_04/04 12 BA/RM90/GB/0404 Elma GmbH & Co KG