COMPONENT MAINTENANCE MANUAL

Similar documents
COMPONENT MAINTENANCE MANUAL

PURPLE K POWDER EXTINGUISHERS INSTALLATION, OPERATION, MAINTENANCE AND RECHARGE MANUAL

F-CLASS MODEL M6L WET CHEMICAL FIRE EXTINGUISHER Installation, Operation, Recharge and Maintenance Manual

COMPONENT MAINTENANCE MANUAL WITH ILLUSTRATED PARTS LIST

OWNER'S SERVICE MANUAL NO INSPECTION, MAINTENANCE AND RECHARGE

SERVICE MANUAL (v1) UL / ULC. WET CHEMICAL HAND PORTABLE RESTAURANT KITCHEN FIRE EXTINGUISHERS Model: SF-6LK / WBDL-6LK

HIGH PERFORMANCE HEAVY DUTY INDUSTRIAL STORED PRESSURE

WHEELED STORED PRESSURE

P3HAFEX. System Description

TRAINING BULLETIN TOOLS 1 May 27, 2011 PRESSURIZED WATER EXTINGUISHER

Reflex fire detection and extinguishing system filled with ABC dry powder. Installation, operation and maintenance instructions

Technical Data Sheet No. JS-SM-38 DOCUMENT TITLE 3.5KG CARBON DIOXIDE FIRE EXTINGUISHERS

OPERATING INSTRUCTIONS (P3DOC Issue B) and CE Conformity Declaration for Aircraft Fire Extinguisher

Reflex fire detection and extinguishing system charged with Novec 1230 extinguishing agent. Installation, operation and maintenance instructions

Extinguishers. Commercial Industrial High rise buildings

DRY CHEMICAL AND CLEAN AGENT HAND PORTABLE FIRE EXTINGUISHERS

DRY POWDER FIRE EXTINGUISHER (Stored Pressure) ABC TYPE - PORTABLE

A. NFPA 2001 Standard for Clean Agent Fire Extinguishing Systems 2004 edition.

Flammable liquids, gasoline, oil etc. Advantages. 21 B. Ø 920 mm 21 B. Ø 920 mm

OWNERS SERVICE MANUAL

OWNERS SERVICE MANUAL NO INSTALLATION, OPERATING & SERVICING INSTRUCTIONS

FIRE EXTINGUISHERS. Chapter 2. - Co2 Fire Extinguisher - Dry Foam Fire Extinguisher - Foam Fire Extinguisher - Portable Foam Applicator

Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System

Technical Data Sheet No. JS-SM-33 DOCUMENT TITLE. 2.0kg ABE TYPE STORED PRESSURE DRY POWDER PORTABLE FIRE EXTINGUISHER MODEL: R2.

FIre Extinguishers. K-GUARD Wet Chemical Fire Extinguishers Manual INSTALLATION 2014-DEC-29 REV. 03 PAGE 1 EXTINGUISHERS

Norminal Sprinkler Temperature Rating

Chapter 26 FIRE PROTECTION

CIRRUS AIRPLANE MAINTENANCE MANUAL

SPECIFICATION: ECS SERIES CLEAN AGENT FIRE SUPPRESSION SYSTEM

The Combustion Process THE FIRE TETRAHEDRON FUEL TEMPERATURE

GETZ EQUIPMENT INNOVATORS PART NO.: 9G58619 MODEL: SV1 150 PR VACUFILL SYSTEM (Revised 2/25/14)

SPECIFICATION: Kidde Engineered Fire Suppression System Designed for use with 3M Novec 1230 Fire Protection

"S" SERIES IMMERSIBLE PUMP OWNER'S MANUAL INSTALLATION OPERATION PARTS Models S12 S16

1. ACCESSORIES SUPPLIED WITH THE AIR CONDITIONER 2. LOCATION OF INDOOR AND OUTDOOR UNIT 3. INSTALLATION/SERVICE TOOLS (ONLY FOR R410A PRODUCT) 4.

OPTIONAL INFORMATION PORTABLE FIRE EXTINGUISHERS SELF INSPECTION CHECKLIST

ENSPECO Recovery/ Recycle/ Evacuate/ Recharge

IGS-M-SF-01(0) IGS. Iranian Gas Standards. CO2 Fire Extinguisher, Portable Type

Catalog. Self-operated Regulators Volume 2 Temperature Regulators

SPRINKLER HEAD. Upright, Pendent & Recessed Pendent Sprinklers MODEL: SD1010, SD1015, SD1030, SD1032 DESCRIPTION TECHNICAL SPECIFICATION

VERSAFLOW VORTEX Supplementary instructions

GETZ MANUFACTURING PART NO.: MODEL: SV1 100 PR VACUFILL SYSTEM (Revised 6/7/05)

Attachment 1. to ClassNK Technical Information No.TEC-0764 Malta Maritime Authority Date Revised 28 August 2008 Page 1 of 10 This Administration Requi

DEPARTMENT OF LICENSING AND REGULATORY AFFAIRS DIRECTOR S OFFICE GENERAL INDUSTRY SAFETY STANDARDS PART 8. PORTABLE FIRE EXTINGUISHERS

Technical Data Sheet No. JS-SM-40 DOCUMENT TITLE 2.0 LITRE STORED PRESSURE WET CHEMICAL FIRE EXTINGUISHER

Subchapter 7. General Industry Safety Orders Group 27. Fire Protection Article 157. Portable Fire Extinguishers. Return to index New query

SERVICE INSTRUCTION SI0035 Rev NC Page 1 of 3

ENGINEERING SPECIFICATIONS FOR FM-200 CLEAN AGENT INDIRECT PRE-ENGINEERED FIRE SUPPRESSION SYSTEMS

Pre-Engineered Fire Suppression

OWNERS SERVICE MANUAL NO

FM-200 In-Cabinet Series

TK-1001, 1101, 1201, 1301, 1601

FIRE EXTINGUISHER. Automatic / Dry Powder, Foam, Co2, Wet Chemical, Trolley Extinguishers

SPRINKLER HEAD. Vertical Sidewall Sprinkler MODEL: SD2133, SD2121 DESCRIPTION MAXIMUM COVERAGE TECHNICAL SPECIFICATION SPRINKLER OPERATION RATINGS

Differential Pressure and Flow Meter. Media 5 Indicator 160 Ø PN 50

Fight or Flee? Extinguisher Basics Extinguisher Use Extinguisher Placement and Spacing Hydrostatic Testing OSHA Requirements Test Your Knowledge

Band Heaters W A T L O W. Special Mica Barrel and Nozzle

COMDTPUB P NVIC JUNE 1995

PRODUCT MANUAL FIRE EXTINGUISHER

Advance Optima Continuous Gas Analyzers AO2060-Caldos15, -Caldos17, -Magnos106, -Uras14 Category 2G Analyzer Modules

WORMALD INTERNATIONAL ELECTRIC VALVE ACTUATOR

For Kidde 10 lb dry chemical fire extinguishers with nylon Zytel (black plastic) valve assemblies & steel cylinders.

Powder Extinguisher ABC (stored pressure) Portable powder extinguishers

Marley Ultra Quiet Fan

OWNER'S OPERATION AND MAINTENANCE MANUAL

Norminal Sprinkler Temperature Rating

Installation and Operating Instructions

Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K Upright and Pendent Extended Coverage Light and Ordinary Hazard General Description

Machine needle shut-off nozzle type-s

BMA INFORMATION BULLETIN No. 97 FIRE FIGHTING EQUIPMENT

ESCONDIDO FIRE DEPT TRAINING MANUAL Section Engine Module Page 1 of 7 Extinguisher Types Revised

Government of Bermuda Department of Maritime Administration BERMUDA SHIPPING NOTICE

FIRE EXTINGUSIHER INSPECTION, MAINTENANCE, AND TESTING PROCEDURES

Models Series Series

Portable Fire Extinguishers

Statement of Policy. Fire Extinguisher Use Policy #: SMS-041

WRENCH FLATS NPT 1/2" 7/16" (11,1 mm) NOMINAL MAKE-IN. 1-1/2" (38,1 mm) 2-3/16" (55,6 mm) WRENCH NPT. (12,7 mm) NOMINAL MAKE-IN.

REVISION NO. 1 DATED SEPT 20/10 HIGHLIGHTS

Operating Manual. Model: Float-Controlled Condensate Trap, PN Safety instructions. 2 General description and usage

GUILFORD COUNTY SCHOOLS

Product Data Sheet Adsorption Dryer DPS (A)

Automatic Sprinklers

OPERATING MANUAL MODEL AIR 1500TM AIR DRYER

MAINTENANCE AND INPSECTION OF FIRE PROTECTION SYSTEMS AND APPLIANCES

special request FACTORY ASSEMBLED UPRIGHT WITH SCREW FIELD ASSEMBLED MODEL S2 SHIELD (SEE INSTALLATION SECTION) WRENCH FLATS *

TECHNICAL DATA. model c-2

INSTALLATION AND COMMISSIONING MANUAL. Neos 100S Integra 20X, 30S, 35X, 40X, 50X

ECS Pre-Engineered Nitrogen Generator. ECS Pre-Engineered Wall Mount Nitrogen Generator PGEN-10/(PGEN-10E)

COUNTY OF ROCKLAND Department of General Services Purchasing Division

ultra quiet fan USER MANUAL INSTALLATION OPERATION MAINTENANCE

A/C COMPRESSOR OIL CHECKING

FIRE EXTINGUISHER SERVICING & MAINTENANCE INSTRUCTIONS

ANSUL. Twin-Agent Fire Fighting/Securing Systems Specifications. Models 450/50-B, 450/100-B, 900/100-B INDEX SPECIFICATIONS

Twin-Agent Fire Fighting/Securing Systems Specifications

New Construction Fire Inspection Process

UL LISTED. SPRINKLER HEADS IN STOCK: Pendent Upright Horizontal sidewall Concealed. RESPONSE Quick response Standard response

A. Section Includes: Fire extinguishers and cabinets including necessary accessories.

SERVICE BULLETIN A

INSTALLATION INSTRUCTIONS TXV Coils for Manufactured Housing EMA

Hospitals and Major Medical Centers

Table Top Patio Heater

Transcription:

WITH ILLUSTRATED PARTS LIST HALON 1/ 1,2/ 2,5 AIR TOTAL List of Portable Fire Extinguishers Part No. Type: 74-00 HAL 1,0 74-20 HAL 1,2 74-21 HAL 1,2 (LH) 76-00 HAL 2,5 COMPONENT MAINTENANCE MANUAL TOTAL Feuerschutz GmbH Industriestr. 13 D-68526 Ladenburg Page 1 of 13

Inspection Record Inspec. No. Date issued Performed date Inspec.No. by Date issued Performed date by Total weight Page 2 of 13

Table of contents Index Page Date Cover page 1 January 2005 Inspection record sheet 2 August 2003 Table of contents 3 January 2005 Description 4 August 2003 Operating instructions 5 August 2003 Technical data 5 January 2005 Inspection 6 August 2003 Disassembly and cleaning 7 August 2003 Filling instructions 8-9 May 2008 Storage 10 August 2003 Illustrated parts list 11-12 January 2005 Annex temperature curves 13 August 2003 Page 3 of 13

Description (see illustration 1) (1) Portable fire extinguishers type HAL 1, HAL 1,2 and HAL 2,5 are intended for use in aircraft pilot- and passenger cabins. They are filled with HALON 1211. The fire extinguishers are approved for the attack on flammable solids, flammable liquids, flammable gases and for fires in the presents of electrical tensions up to 1000 Volt. The extinguishers are designed for a one hand operation. (2) Range of application (a) (b) Fire Class ABC Extinguishing agent HALON 1211 (3) The fire extinguisher consists of 3 main components (a) (b) (c) The cold drawn steel container, pressure tested to 30 bar (427 psi), painted red RAL 3000. The discharge valve with siphon tube and pressure gauge. The valve is pressure lever operated and can be shut-off. The carrying handle is movable. The extinguishing agent HALON 1211 is nitrogen super pressurized. Filling pressure: 11 bar (156.5 psi) at 15 C (59 F). Illustration 1 Page 4 of 13

Operating instructions When held in place with a strap, open fastener and remove extinguisher from bracket. Bent down safety lever (black), remove seal wire and than squeeze release lever (red). Attack fire with the discharging extinguishing agent. Attack the fire starting from front. Discharge agent in shots according to requirements. Technical data Part. No. 74-00 74-20 74-21 76-00 Height 265mm 10.4 in. 265mm 10.4 in. 265mm 10.4 in. 380mm 15 in. Dimensions Weight w/o bracket and Weight bracket and fastening fastening strap strap approx. Dia. Kg Lbs Kg Lbs 82mm 3.2in. 1.99 * 4.39 0.21 0.46 82mm 3.2in. 2.19 * 4.83 0.21 0.46 82mm 3.2in. 2.19 * 4.83 0.5 1.10 100mm 4in. 4.02 * 8.86 0.41 0.90 Nominal pressure by 15 C/ 59 F 11 bar 156.5 psi 11 bar 156.5 psi 11 bar 156.5 psi 11 bar 156.5 psi Container test press. Filling Discharge time approx. Kg Lbs 30 bar 427 psi 1 2.2 7 sec 30 bar 427 psi 1.2 2.65 9 sec 30 bar 427 psi 1.2 2.65 9 sec 30 bar 427 psi 2.5 5.51 Heights 20.000m 65.616 ft. 20.000m 65.616 ft. 20.000m 65.616 ft. 20.000m 10 sec 65.616 ft. * for exact weight see the check note label on the extinguishers backside. (1) Operating temperature range All fire extinguishers can be operated at temperatures of between -40 C and +70 C (-40 F and +158 F). (2) Throw distance Throw distance for the extinguishers 74-00, 74-20, 74-21 and 76-00 is 3.50 m (11.5 Ft) at +20 C (+68 F). Page 5 of 13

Inspection (1) The inspection should be carried out every 2 years, or in shorter intervals, depending on internal regulations. Inspection: Integrity of wire seal visual inspection Condition of extinguisher, mounting bracket and visual inspection fastening strap Legibility of label visual inspection Container pressure / gauge visual inspection at room temperature the pointer must be in the green section of the dial. Weight control / scale Permissible deviation: 2% of fill capacity / year, but not more than 10% of fill capacity (2) Basic overhaul Container hydrostatic pressure test All fire extinguishers listed in these maintenance procedure instruction must be hydrostatically pressure tested at regular 10 year intervals (see label on back). Should deficiencies be detected at a regular inspection this pressure test must be performed earlier. These tests shall only be carried out by an authorized aviation equipment inspector, well adverted with the safety standards applicable to this test. Furthermore, also required is an adequate room and the necessary test equipment. After the hydrostatic pressure test the cylinder has to be desiccated inside. The manufacturer recommend to replace the extinguisher after 10 years! Page 6 of 13

Disassembly and cleaning Empty the extinguisher (observe environmental protection regulations concerning HALON 1211). Unscrew valve (50*, 50A*) with open-end wrench size 17. Unscrew the siphon tube (220*, 220A*). Visually inspect valve and container threads and O-ring seat for damage. Press operation lever and check mobility of valve spindle. Visually inspect inside of container for corrosion. Screw siphon tube back up to the limit stop with a torque of 20 Nm. Screw valve with new O-ring (20*) back on to the container. (Apply a light layer of acid free vaseline to thread and O-ring). Torque: 30 Nm Clean container. Check label, mounting bracket and fastening strap for damage. * see page 12 fire extinguisher parts list Page 7 of 13

Filling (see illustration 2) The fire extinguisher shall only be refilled by a maintenance service shop with an approval to Commission Regulation (EC) No 1702/2003. When filling HALON extinguishers the filling station must observe the following instructions: (1) Determining net weight: After assembly the empty extinguisher it must be placed on a scale to determine the weight. This net weight must be entered in the check note. (2) Refilling: Place the extinguisher on a scale and connect it to the fill station. During the filling process the release lever of the extinguisher must be held down with a clamp. The weight of this clamp must be taken into consideration in the weighing process. The extinguishing agent is filled according to weight. Care must be taken to observe the permissible fill tolerances. Portable Fire Extinguishers: HAL 1 1 Kg HALON 1211 (+0-0.02 kg) HAL 1,2 1.2 Kg HALON 1211 (+0-0.02 kg) HAL 2,5 2.5 Kg HALON 1211 (+0-0.02 kg) After the filling the extinguisher must be pressurized with gaseous nitrogen (99.0 to 99.8 degree of purity, dew point -40 C, (-40 F)). The pressurization for HAL 1, HAL 1,2 and HAL 2,5 should be according to temperature-pressure curves T565*. The nominal fill pressure at +15 C is 11 bar (mark in green section of gauge dial). Than move the closed extinguisher horizontally back and forth to mix HALON and nitrogen together. In this process the container pressure drops. Depressurize the extinguisher to the specified pressure. Remove the clamp from container release lever. Secure release lever. The fill line can than be depressurized and also closed. * see page 13 Page 8 of 13

(3) Determination of total weight: After the fill process is completed and the extinguisher disconnected from the fill line, the extinguisher must be placed back on the scale again to determine the total weight. This weight must be entered in the inspection record card and on the extinguisher check note (when weighing the extinguisher, the weight of seal, seal wire and the approval label must be included). Seal the extinguisher (Seal wire tensile strength 40 N). (4) Acceptance of filled extinguisher: Acceptance and clearance of the extinguisher must be made by authorized staff. Acceptance test: General visual inspection of the extinguisher Checking operating pressure (see page 5 technical data) Tightness control. Checking the unit after 3 weeks in storage Illustration 2 Filling Station Schematic arrangement Page 9 of 13

Storage The storage temperature shall not exceed 70 C (158 F). Ambient air should be dry and free of corrosion causing components. The extinguisher must be inspected every 2 years (or in shorter periods according to internal regulations) as described in item 1. Page 10 of 13

Parts List (see page 12) This parts list contains all subassemblies and components of the above listed fire extinguishers. Definition of parts list: (1) Item numbers The first number in the first line is the number of the depicted extinguisher. The second number is the item number shown on illustration 3. A stroke in front of the item number indicates that this part is not shown on the illustration. (2) Part number Manufacturers original part number. (3) Ident number Manufactures EDP-number (4) Airlines part number This section remains free for use of the airline (5) Description The section description contains the name of every subassembly or extinguisher component. (6) EFF-Code Section EFF-code refers to the association of similar subassemblies / components. These parts are identified with the letters A, B, C. Is a component used in all extinguishers this section remains empty. (7) Quantity per extinguisher Number of identical pieces per extinguisher. Page 11 of 13

Item No. Part No. Ident No. Airlines part No. Description EFF- Code Number per unit 1 74-00 0821166 Extinguisher HAL 1 A 1A 74-20 0821164 Extinguisher HAL 1,2 B 1A 74-21 0821226 Extinguisher HAL 1,2 (LH) B 1B 76-00 0821165 Extinguisher HAL 2,5 C 20 E000-02785 0120101 O-ring 1 30 0074-45 0240166 Instruction label 1 40 0074-46 0240169 Check note label 1 50 0074-U12 0621087 Valve assembly HAL 1 / 1,2 A, B 1 50A 0076-U04 0621303 Valve assembly HAL 2,5 C 1 220 0074-U07-1 0621088 Siphon tube HAL 1 / 1,2 A, B 1 220A 0076-U14 0621029 Siphon tube HAL 2,5 C 1 230 0140-00 0621139 Bracket HAL 1 / 1,2 * A, B 1 230A 0119-2 0621101 Bracket HAL 2,5 * C 1-230B 0140-02-1000 0254303 Bracket HAL 1,2 (LH) * B 1 240 0140-U51 0254076 Fastening strap HAL 1 / 1,2 A, B 1 240A 0119-2-U51 0254077 Fastening strap HAL 2,5 C 1 240B 0140-02-1010 0254304 Fastening strap HAL1,2 (LH) B 1 * installation with fastening strap Illustration 3 Fire extinguisher parts Page 12 of 13

Page 13 of 13