Configuration wizard WRS-K. Wolf GmbH Postfach 1380 D Mainburg Tel /74-0 Fax / Internet:

Similar documents
Operating instructions

BM Programming Module. For the heating engineer Installation instructions

Operating instructions Oil condensing boiler

Standard Air Handling Units

Modular Standard HP Chiller 1/4 screw compressor with Carel driver

N M AirControl AHU. Control manual

DEIF A/S. Operator s Manual. Basic Gen-set Controller. Display readings. Push-button functions. Alarm handling. Log list C (UK)

Application Manual Loop Water Controller

1.7. Insulation fault evaluators EDS460/490 EDS461/491

BWL air heat pumps BWS brine heat pumps

Installation and operating instructions

NA G µair CONNECT 2

Operation and Maintenance Instructions

Insulation fault evaluator EDS460-DG

Topvex SX/C, Topvex TX/C Air Handling Unit

Standard Chiller Modular HP 1/4 Generic/Bitzer screw compressor and CAREL valve

Boiler controller S-Tronic Plus

INSTALLATION AND OPERATION MANUAL

Operation manual FR EN NL DE IT. intended for professionals and end users. To be saved for future consultation

BLAUAIR AUTOMATIC CONTROL SYSTEM

Reference Guide for Microprocessor Controller

Lift Station Level Controller

IN NOURISHING SECURITY.

Service control manual Smart HP. Application FLBB0mHPGU

ISOSCAN EDS460-DG. Insulation fault locator for DC IT systems with high system leakage capacitances

C User manual

User manual for reversible heat pump

Automation System TROVIS 5400 Ventilation Controller TROVIS Mounting and Operating Instructions EB 5477 EN. Electronics from SAMSON

WOLF GAS CONDENSING BOILERS COMFORTLINE

and Channel indicator and monitoring unit B Operating Instructions 2.00/

Products no longer available

SIRe Advanced Air Curtains Electric With quick guide. SIReAA GB DE FR For wiring diagram, please see last pages. ES

1.7. Insulation fault evaluators EDS460/490 EDS461/491

Corrigo E - User Manual Ventilation

Multi-zone Standard air-conditioning units

WOLF CONTROL SYSTEM AIR HANDLING

EXact Control System Basic instructions for the VEX200 series

ISOSCAN EDS460/490 EDS461/491. Insulation fault locators with control and display function for EDS systems (insulation fault location systems)

REMOTE CONTROL FOR CHILLER MYCHILLER

Ventilation control for SupraBox COMFORT 800 to 5000

Technical documentation Fan coil unit

Index. 1. General description of the application Types of units controlled Types of regulation Condensation...

EN CLIMACIAT. Control manual

Corrigo E - manual Ventilation application

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

Homepage > Products > Decentralised ventilation systems > Vertical units > Type FSL-V-ZAB/SEK FSL-V-ZAB/SEK

No part of this publication may be reproduced, stored in an automated data file or made public in any form or by any means, whether electronic,

Topvex SR 09, 11, Topvex TR Compact Air Handling Units

Fan coil unit KL. Wall unit Ceiling unit

Sauter flexotron 800 ventilation Manual

DIGITAL TEMPERATURE RELAY TR-100

Standard Rooftop 1/2 compressors

Installation and Operating Manual. Merlin 5064 V3. System Manager

CM3500 Controller - ClimateMaster DOAS Water-Source Heat Pumps - Rev.: 7 Oct, 2008B

DC 60 & DM 60 displays

TAP v2.10 Version Date: 6/12/13. Document Microprocessor Controller for Tempered Air Products

Installation and Operating Manual. Merlin IO 5064 V4 with BM-T. System Manager

VIESMANN. Operating instructions DIGITAL TIME SWITCH. for the system user. Digital time switch for the Vitodens 100-W, type WB1B

Engine Control Unit, ECU 100 Push-buttons LEDs Display and menu structure Display readings Alarm handling and log list

Tasman Sea Control System

Tempered Water Logic Control OPERATION l TROUBLE SHOOTING

Subcooling is defined as the point at which liquid is cooled below it s condensing temperature. Example: Refrigerant R404A

Operating Manual RCM420

Manual for the integration in BMS/GTC

PoolPak SWHP with CommandPak Control System CPCS BACnet IP User s Guide DOCUMENT #: SVW05-BACNETIP

CONTENTS Installation Precautions... 1 Chapter 1 Product Introduction... 2 Chapter 2 Technical Specifications... 3

TECHNICAL MANUAL CVM 20 C 5005 CV/04-99 GB

OPERATING INSTRUCTIONS. G214 Software - Version 4

Ventilation in balance

Operating instructions

For the operator/for the heating engineer. Operating and Installation Manual VRC 430. Weather compensator VRC 430

Service Manual. Chiller unit MQH R 410A. Release Date Rev Review Date november

Control Equipment Siemens Climatix. Basis Document Climatix Control System

SIRe Competent Air Curtains Water With quick guide. SIReAC. For wiring diagram, please see p Original instructions

Accent User. Version. Rheem. PO Box 146, ABN:

MF-PFA ver 3.x. Micaflex PFA ver 3. Pressure- and Flow transmitter with alarmfunction. Installation- & Operation manual [Dok. id: mi-303gb_180528]

ProCon 16, 31, 47, 75, 77 & HT. RVA 46. Zone Controller Commissioning Data.

USER MANUAL. CARRIERrtc electronic control 48/50 EN/EH 38 SZ/SF/NZ/NF

Refrigerated air dryers

Copyright AB Regin, Sweden, Corrigo manual Ventilation application

D Ice and Snow Detector Type 1773 for the TF-E System

Installation and maintenance manual

Thermometers and temperature controllers

Safety Temperature Limiter STL 50 Certified to DIN EN (replaces DIN 3440)

ivector HEATER/COOLER 2 AND 4-PIPE MODELS.

IPC108D - IPC108E (V.2.0)

The integral solution for. Air Handling Units. Technology & Evolution

Radio fire warning panel SRC 3000

T600MEP-2 Programmable Economizer Thermostat

Boiler controller Lambdatronic S 3200

Temperature Controller CC24-7 UNIBOX USER S MANUAL Legion Dr. Mason, MI USA October 2010 Ph. (517) Fax (517)

Follett Performance Plus

Operating Manual UV Monitor UVT 18

Saving energy with Synco

39HX. High-efficiency dual-flow air handling unit PRODUCT SELECTION DATA. Plug & play unit (built-in control) Class A+ across entire range

AC&R Controller RWR Basic Documentation VR2002 for water to water heat pump units

Operating Instructions for use by heating contractor. VITOTRONIC r 100 VITOTRONIC r 300-K IMPORTANT

Boiler controller SPS 4000

Copyright AB Regin, Sweden, Corrigo E manual Ventilation application

Remote alarm indicator and test combination MK2430

Transcription:

wizard WRS-K Valid for software version 2.1.024 or higher Wolf GmbH Postfach 1380 D-84048 Mainburg Tel. +49 8751/74-0 Fax +49 8751/741600 Internet: www.wolf-heiztechnik.de Document no. 3062933_0511 Subject to technical modifications GB

Contents Contents...Page 1. Installation / commissioning / operating overview... 3 2. Post-configuration, air quality / CO 2 sensor... 4 3. Post-configuration, remote control... 5-6 4. Post-configuration, LON / BacNet / ModBus... 7-8 5. Post-configuration, pressure / flow rate control... 9-12 6. System configuration... 13-17 7. Restoring factory settings... 18 8. Notes... 19 2 3062933_0511

Installation / commissioning / operating overview 1. Commissioning - According to DIN EN 50110-1, only qualified electricians may carry out the installation and commissioning of the ventilation control unit and connected accessories. - Observe all regulations stipulated by your local power supply utility and all VDE or local regulations. - DIN VDE 0100 regulations regarding the installation of high voltage systems up to 1000 V. - DIN VDE 0105-100 operation of electrical systems. - Only original Wolf accessories may be used (electric heater bank, condensate pump, servomotors, etc.), otherwise, Wolf cannot provide a warranty. Operating overview 1 2 3 4 5 6 1 Displaying and acknowledging active fault messages 2 Displaying the system operating data (set / actual values) 3 Access to the main menu 4 Forward scrolling within a menu and increasing values 5 Switching the system on and off, selecting menu points, confirming inputs 6 Backwards scrolling within a menu and reducing values 3062933_0511 3

Post-configuration, air quality / CO 2 sensor 2. When retrofitting an air quality sensor (mixed gas or VOC,CO 2 ) follow the instructions below. Please press Prg and Esc for approx. 2 sec. and enter manufacturer password 4711. Activation Manufacturer password Select Inputs/outputs with confirm with Enter and 4711 11.4 C FR 20.03.09 11:02 PRG OPERATING DATA ESC MENUS Press Esc button 18.5 C 21.0 ON/OFF SET Main menus Inputs/outputs System parameters Alarm management Standard settings Displays Time functions Heating contractor S Select Analogue inputs with confirm with Enter and Select Standard settings with confirm with Enter and Manufacturer menu Digital inputs Analogue inputs Digital outputs Analogue outputs Select Air quality sensor with confirm with Enter Air quality sensor B-- Type 0-10 V Analogue inputs and 15 Select Air quality control with and set to Yes with Enter Standard setting GE-26 Air quality control active (No) S Control is enabled Hold down Esc button until you jump to the standard screen Enter B08 with and confirm with, type 0-10 V, confirm with Enter Analogue inputs Air quality sensor B08 KLM-M/L Type 0-10 V 15 The input has been configured Hold down Esc button until you jump to the standard screen 4 3062933_0511

3. When retrofitting a remote control, follow the instructions below. Post-configuration, remote control 11.4 C 18.5 C 21.0 FR 20.03.09 11:02 PRG OPERATING DATA ESC MENUS Press Esc button ON/OFF SET Main menus Standard settings Displays Time functions Heating contractor S Select Heating contractor with confirm with Enter and wolf-heiztechnik.de Continue with Heating contractor Password: 1234 Select 1234 with Enter and confirm with 3062933_0511 5

Post-configuration, remote control Heating contractor - menus Alarm management Service Other Night ventilation Limits Select Other with Enter and confirm with Other... Remote control installed? S-02 No Confirm with Other... S-02 Remote control installed? Yes Select "Yes" with Enter and confirm with W-E2 Restart system (mains OFF/ON) System restart Switch power supply to controller OFF and ON again The remote control is enabled 6 3062933_0511

Post-configuration, LON / BacNet / ModBus 4. When retrofitting a LON / BacNet / ModBus interface, follow the instructions below. 11.4 C 18.5 C 21.0 FR 20.03.09 11:02 PRG OPERATING DATA ESC MENUS Press Esc button ON/OFF SET Main menus Standard settings Displays Time functions Heating contractor Select Heating contractor with confirm with Enter and wolf-heiztechnik.de Continue with Heating contractor Password: 1234 Select 1234 with Enter and confirm with 3062933_0511 7

Post-configuration, LON / BacNet / ModBus Heating contractor - menus Alarm management Service OtherNight ventilation Limits Select Other with Enter and confirm with Confirm with S-04 Other... BMS protocol >LON-Works Transfer speed >4800 (RS485/RS422) BMS address: 001 ESC CANCEL SAVE Other... Protocol type: BacNet S-05 ESC CANCEL SAVE Select required connection with - No proto - pco Manager - LON-Works - Bac-Net - ModBus Stave Standard and confirm with Enter BMS protocol has been set Hold down Esc button until you jump to the standard screen 8 3062933_0511

The following settings should be made on site for pressure control. Post-configuration, pressure / flow rate control The preset parameter values ensure operation of the system, but have to be matched to customer specifications during commissioning. Selecting the number of pressure sensors Standard screen Esc Select heating contractor Enter password 1234 Select pressure/flow rate Pressure/flow rate ctl DV1 Diff. pressure sensor Number -2- Type 0/10 V Range 0/1000 Pa Number 2 Range 1000 (If only one sensor is selected, the differential of the extract fan can be entered on the next screen: overpressure, 0-50%; underpressure 0 - +50%) Pressure/flow rate ctl Diff. extract fan DV2 00.0% 00.0% The following settings for flow rate control have to be carried out on site: Fan type, k-factor Druck- / Volumenstrom DV3 Supply fan k-faktor: 0 Fan type: 1 k-faktor 0 Typ 1 Esc ZURÜCK AUSWAHL ANZEIGE Druck- / Volumenstrom DV4 Diff. extract fan k-faktor: 0 Fan type: 1 k-faktor 0 Typ 1 Esc ZURÜCK AUSWAHL ANZEIGE The selection formula for the corresponding fan type and the k-factor are indicated on the fan. select fan type 1 for formula select fan type 2 for formular 3062933_0511 9

Post-configuration, pressure / flow rate control Enter set values for automatic mode Standard screen Esc Select time functions Set values Select pressure control, ventilation air Enter values Select pressure control, extract air Enter values Set values, time prog Pressure control, ventilation air 00000 Pa 00000 Pa 00000 Pa 00000 Pa 800 Pa 600 Pa 300 Pa 100 Pa or Select pressure control, extract air Enter value 1300 m³/h 1100 m³/h 900 m³/h 800 m³/h Set values, time prog Pressure control, extract air 00000 Pa 00000 Pa 00000 Pa 00000 Pa S or 800 Pa 600 Pa 300 Pa 100 Pa Hold down Esc until you jump to the standard screen 1300 m³/h 1100 m³/h 900 m³/h 800 m³/h 10 3062933_0511

Post-configuration, pressure / flow rate control Set value for backup mode, heating/cooling Setting night ventilation and peak ventilation Standard screen Esc Select heating contractor Enter password 1234 Select backup mode Select heating pressure Enter value Backup mode SB-04 Heating 800 Pa Pressure 0000 Pa or 800 m³/h Select cooling pressure Enter value Esc Backup mode SB-09 800 Pa Cooling or Pressure 0000 Pa 800 m³/h Select night ventilation Fan pressure Enter value Esc Night ventilation NL-07 800 Pa Fan pressure 0000 Pa or 800 m³/h Select peak ventilation Fan, ventilation air/extract air Enter value Peak ventilation SL-05 Fan Ventilation air Extract air 0000 Pa 0000 Pa or 800 Pa 800 m³/h Hold down Esc until you jump to the standard screen 3062933_0511 11

Post-configuration, pressure / flow rate control Entering a set value for manual mode Standard screen Esc Standard settings Select vent. air fan pressure, manual mode Set value STANDARD SETTING GE-05 Vent. air fan pressure, set value for manual mode 000.0 Pa or 000.0 Pa 0 m³/h Select extr. air fan pressure, manual mode Set value STANDARD SETTING GE-05 Extr. air fan pressure, set value for manual mode 000.0 Pa or 000.0 Pa 0 m³/h Select vent. air pressure for external demand Set value STANDARD SETTING Vent. air pressure for external demand Stage 3: Stage 2: Stage 1: GE-12 0 Pa 0 Pa 0 Pa Select extr. air pressure for external demand Set value or 000.0 Pa 000.0 Pa 000.0 Pa 0 m³/h 0 m³/h 0 m³/h STANDARD SETTING Extr. air pressure for external demand Stage 3: Stage 2: Stage 1: GE-12 0 Pa 0 Pa 0 Pa 000.0 Pa 000.0 Pa 000.0 Pa Hold down Esc until you jump to the standard screen or 0 m³/h 0 m³/h 0 m³/h 12 3062933_0511

System configuration 5. If commissioning is not carried out by Wolf, configuration must be carried out as follows. After connecting the controller to the power supply, system configuration is carried out first of all. You are then prompted to configure the system according to function. The individual screens and the relevant selections should be worked through as follows. NB The system configuration is preset by Wolf The following should only be carried out if the controller is replaced Please wait... K System configuration in preparation ESC CANCEL SAVE Operation (selection) is carried out with the arrow keys, the selected function is confirmed with Enter, and then the next menu is opened automatically. You can return to a menu with Esc to change incorrect settings. K-01 System type: Vent./extr. air system The following selection is possible via arrow keys: Ventilation air system Vent./extr. air system Confirm selected system type with Enter Fan: K-02 Variable Select fan speed: Single stage Two-stage Three-stage Variable Pressure control Flow rate control Selection for pressure / flow rate control 3062933_0511 13

System configuration - setting Heating: K-03 CKL 1300 electric heater bank variable CKL 3000 DHW pump bank Select heating mode: No heating DHW pump bank El heater bank stage 1 El heater bank stage 2 El heater bank stage 3 El heater bank stage 4 El heater bank stage 5 El heater bank var. KGWO Cooling: K-04 No cooling Select cooling mode: No cooling Cold water pump bank Direct evap. stage 1 Direct evap. stage 2 K-05 Air dampers Outs./dis. air dampers Select air dampers: No air dampers installed Mixer air dampers Mixer/vent/ex.air dmpr Outs./dis. air dampers HR: K-06 PHE Select heat recovery system: No HR available PHE RHE CCS 14 3062933_0511

System configuration - setting K-07 Control type: Vent. air control Select temperature control: Vent. air control Room vent. air cascade Ext./vent. air cascade Filter: K-08 Vent./extr. air filter Select filters: No filter Outside air filter Ventilation air filter Extract air filter Outs./vent. air filter Vent./extr. air filter Outside/extr. air filter Outs./vent/ex. air filter K-09 Number FD: 1 fire damper Select fire dampers: No FD available 1 fire damper 3062933_0511 15

System configuration - setting K-10 Ext. demand: None available Select external systems, demand: None available Remote start/stop Remote step control Remote On/Off + stages K-11 Remote control None available Select remote control: None available Set value transducer Remote control BMS: K-12 No BMS available Select building management system: No BMS available pco Manager BacNet LON Works Nadbus K-E0 Pre-configuration completed Continue with Enter The selected configuration is then displayed in the overview Changes cannot be made 16 3062933_0511

System configuration - overview Overview of the preset configuration Vent./ex. air syst. w/ variable speed fan without heater bank No cooling bank Outs./dis. air dampers Continue with Enter K-E1 Continue with Heat recovery PHE Vent. air control Outside/extr. air filter 1 fire damper No ext. demand Continue with Enter K-E2 Continue with Remote control No BMS available K-E3 Continue with Enter Continue with K-E4 Restart system (mains OFF/ON) Continue with Enter complete Switch control unit OFF and ON again The configuration is saved 3062933_0511 17

6. Restoring factory settings Delete all settings from the standard menu. Restoring factory settings (Delete preset configuration) Please press Prg and Esc for approx. 2 sec and enter manufacturer password 4711. Confirm with Esc. Manufacturer password 4711 Select Other with Enter and confirm with Alarm management Other... Select Accept default values confirm with Enter and Accept default values <ENTER> After approx. 30 sec, the display jumps automatically to the system configuration level 18 3062933_0511

Notes 3062933_0511 19

Wolf GmbH Postfach 1380 D-84048 Mainburg Tel. +49 8751/74-0 Fax +49 8751/741600 Internet: www.wolf-heiztechnik.de