Exaggerated for Clarity. Residential Pendent, Recessed Pendent. System No. Submitted By Spec Sect Para Location Date Approved Date

Similar documents
40.49 V27, K5.6 FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS. Residential Horizontal Sidewall, Recessed Horizontal Sidewall V2744 QUICK RESPONSE

DISCONTINUED PRODUCT

40.10 V27, K5.6. Standard Spray; Upright, Pendent and Recessed Pendent. System No. Submitted By Spec Sect Para Location Date Approved Date

40.43 V38, K5.6 FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS. Residential Low Flow Adjustable Concealed Pendent V3806 QUICK RESPONSE

40.31 V34, K14.0 FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS

40.15 V34, K8.0 FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS

DISCONTINUED PRODUCT. reference publication

40.19 V34, K115 FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS

40.50 V38, K5.6. Adjustable Concealed Standard Spray Pendent Standard and Quick Response

40.11 V27, K5.6 FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS

40.65 V36, K8.0. Dry Type Standard Spray. Horizontal Sidewall. Recessed Horizontal Sidewall

40.60 V36, K5.6. Dry Type Standard Spray Pendent, Intermediate Level Pendent & Recessed Pendent

40.60 V36, K5.6 SLEEVE AND SKIRT PLAIN BARREL

FLUSH HORIZONTAL SIDEWALL

40.61 V36, K8.0 SLEEVE AND SKIRT PLAIN BARREL

Storage Sprinkler. Model LP-46 (SIN) V4603, K25, Standard Response Storage Upright Sprinkler, Patent Pending

Finishes Plain Brass Chrome Plated and other Finishes Available Upon Request. For cabinets and other accessories refer to separate sheet.

Finishes Plain Brass Chrome plated and other fin ishes available upon request. For cabinets and other accesso ries refer to separate sheet.

40.42 V27, K4.9 FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS

Victaulic Europe Phone: Fax:

Norminal Sprinkler Temperature Rating

SPRINKLER HEAD. Upright, Pendent & Recessed Pendent Sprinklers MODEL: SD1010, SD1015, SD1030, SD1032 DESCRIPTION TECHNICAL SPECIFICATION

TECHNICAL DATA. Refer to the Approval Chart and Design Criteria for C-UL-US-EU Listing requirements that must be followed.

Norminal Sprinkler Temperature Rating

SPRINKLER HEAD. Vertical Sidewall Sprinkler MODEL: SD2133, SD2121 DESCRIPTION MAXIMUM COVERAGE TECHNICAL SPECIFICATION SPRINKLER OPERATION RATINGS

TECHNICAL DATA vk470 (K3.0)

STANDARD/QR EXTENDED COVERAGE LIGHT HAZARD ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK617 TECHNICAL DATA

freedom residential pendent sprinkler vk466 (K5.2)

FREEDOM RESIDENTIAL PENDENT SPRINKLER VK470 (K3.0) TECHNICAL DATA

freedom residential horizontal sidewall sprinkler Vk450 (k4.2)

FREEDOM RESIDENTIAL PENDENT SPRINKLER VK468 (K4.9) TECHNICAL DATA

TECHNICAL DATA STANDARD/QUICK RESPONSE EXTENDED COVERAGE LIGHT HAZARD ELO PENDENT SPRINKLER VK608

EC/QREC ORDINARY HAZARD PENDENT SPRINKLER VK572 (K14.0) TECHNICAL DATA

ec/qrec ordinary hazard upright and pendent sprinklers vk570 and vk572 (k14.0)

FREEDOM RESIDENTIAL PENDENT LEAD FREE SPRINKLER VK4700 (K3.0) TECHNICAL DATA

FREEDOM RESIDENTIAL HORIZONTAL SIDEWALL SPRINKLER VK486 (K4.0) TECHNICAL DATA

TECHNICAL DATA. Viking Technical Data may be found on Minimum Operating Pressure: Refer to the Approval Chart.

standard/quick response extended coverage light and ordinary hazard elo sprinklers

TECHNICAL DATA OBSOLETE

STANDARD/QUICK RESPONSE EXTENDED COVERAGE PENDENT SPRINKLER VK602 TECHNICAL DATA

TECHNICAL DATA. UL/C-UL Listed as a standard response. horizontal ceilings. Listings up to a OBSOLETE

FREEDOM RESIDENTIAL HORIZONTAL SIDEWALL SPRINKLER VK460 (K5.8) TECHNICAL DATA

TECHNICAL DATA. Refer to the Approval Chart and Design Criteria for C-UL-US-EU Listing requirements that must be followed.

STANDARD/QR EXTENDED COVERAGE LIGHT HAZARD TECHNICAL DATA ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK617

TECHNICAL DATA OBSOLETE

freedom residential horizontal sidewall lead free sprinkler VK4840 (k4.2)

FREEDOM RESIDENTIAL HORIZONTAL SIDEWALL SPRINKLER VK479 (K3.0) TECHNICAL DATA

freedom residential concealed pendent Sprinkler vk458 (K7.4)

TECHNICAL DATA 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA

Special Features: For Light Hazard Occupancies Only Designed for Corridor Applications 28 Maximum Width Spacing. 3. technical data

standard response/ quick response extended coverage

QUICK RESPONSE EXTENDED COVERAGE HORIZONTAL SIDEWALL SPRINKLER VK630 (K8.0) TECHNICAL DATA

EC/QREC ORDINARY HAZARD UPRIGHT SPRINKLER VK570 (K14.0) TECHNICAL DATA

quick response extended coverage horizontal sidewall sprinkler vk630 (k8.0)

microfast sr/qr extended coverage pendent sprinkler

MICROFAST SR/QR EXTENDED COVERAGE HSW SPRINKLER VK605 (K5.6) TECHNICAL DATA

TECHNICAL DATA. 2. LISTINGS AND APPROVALS culus Listed: Category VNIV FM Approved: Class 2009 NYC Approved: MEA E, Volume 3

quick response Sprinkler 105a October 25, 2010

MicrofastHP EC/QREC FUSIBLE ELEMENT PENDENT HIGH PRESSURE SPRINKLER VK611 (K5.6) TECHNICAL DATA

RAPID RESPONSE Series LFII Residential Sprinklers 5.8 K-factor Horizontal Sidewall, NFPA 13 Optimized Wet Pipe Systems

freedom residential Upright sprinkler vk467 (k4.9)

STANDARD/QUICK RESPONSE ECOH ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK537 (K11.2) TECHNICAL DATA

micromatic Standard response Horizontal Sidewall sprinkler

MicrofastHP EC/QREC FUSIBLE ELEMENT HSW HIGH PRESSURE SPRINKLER VK613 (K5.6) TECHNICAL DATA

WRENCH FLATS 1/2" NPT. 7/16" (11,1 mm) NOMINAL MAKE-IN CENTERLINE OF WATERWAY ESCUTCHEON PLATE SEATING SURFACE

QUICK RESPONSE ELO PENDENT SPRINKLER VK377 (STORAGE-DENSITY/AREA) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3.

Automatic Sprinklers

MICROFAST QUICK RESPONSE PENDENT SPRINKLER VK3311 (K4.2) TECHNICAL DATA

The Viking Corporation s Web site at Rated to 175 psi (12 bar) water working pressure

TECHNICAL DATA. The Viking Corporation s Web site at Overall Length (Sprinkler Body): 2-5/16 (59 mm)

microfast quick response extended coverage hsw sprinkler vk606

WRENCH FLATS 1/2" NPT. 7/16" (11,1 mm) NOMINAL MAKE-IN CENTERLINE OF WATERWAY ESCUTCHEON PLATE SEATING SURFACE

FREEDOM RESIDENTIAL CONCEALED PENDENT SPRINKLER VK468 (K4.9) TECHNICAL DATA

TECHNICAL DATA STANDARD/QUICK RESPONSE EXTENDED COVERAGE PENDENT SPRINKLER VK534 (K11.2)

TECHNICAL DATA. Page 1 of 5

micromatic standard sprinkler VK003 (K2.8) 3. technical data Page 1 of 7

TECHNICAL DATA OBSOLETE

MICROFAST QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) TECHNICAL DATA

standard response/qr extended coverage concealed pendent sprinklers vk614 & vk616

FREEDOM RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) TECHNICAL DATA

standard response large orifice dry

microfast quick response Pendent sprinkler VK302 (K5.6)

mirage Quick response extended coverage concealed pendent sprinklers (vk632 and vk634)

TECHNICAL DATA. Refer to Approval Chart 1 and UL Design Criteria for culus Listing requirements that must be followed.

STANDARD/QUICK RESPONSE EXTENDED COVERAGE DRY HORIZONTAL SIDEWALL SPRINKLER TECHNICAL DATA

mirage standard response concealed pendent sprinkler vk492 (K5.6)

STANDARD/QUICK RESPONSE CONCEALED PENDENT SPRINKLER VK352-D (K8.0) TECHNICAL DATA

RAPID RESPONSE Series LFII Residential Sprinklers 5.6 K-factor Horizontal Sidewall, NFPA 13 Optimized Wet Pipe Systems

QUICK RESPONSE EXTENDED COVERAGE CONCEALED HSW SPRINKLER VK630 (K8.0) TECHNICAL DATA

STANDARD RESPONSE FUSIBLE LINK PENDENT SPRINKLER VK008 (K4.2) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA.

STANDARD RESPONSE DRY PENDENT STANDARD ORIFICE SPRINKLERS TECHNICAL DATA

microfast and microfasthp quick response horizontal sidewall sprinklers (vk305 & vk319)

QUICK RESPONSE EXTENDED COVERAGE FUSIBLE ELEMENT PENDENT SPRINKLER VK601 (K5.6) TECHNICAL DATA

Page 1 of 8 DECEMBER 2018 TFP408. Worldwide Contacts.

micromatic standard sprinkler VK004 (K4.2) 3. technical data Page 1 of 6

TECHNICAL DATA. Viking Technical Data may be found on Maximum Working Pressure: 175 psi (12 Bar).

freedom residential concealed pendent sprinkler vk474 (K5.8)

standard response sprinklers (vk102 & vk202) 3. technical data Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Sprinkler 11j

MICROFAST AND MicrofastHP QUICK RESPONSE PENDENT SPRINKLERS TECHNICAL DATA

mirage Quick response concealed pendent sprinkler vk465 (K4.2)

Transcription:

SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS The Model V3426 residential sprinkler is designed with optimal flow characteristics for use in residential NFPA 13 systems. The larger 6.9 K-Factor will aid in the system design where higher flows are required. The V3426 is also listed for use in wet pipe systems per NFPA 13D and 13R under smooth, flat, horizontal ceilings. The design incorporates state-of-the-art, heat responsive, frangible glass bulb design (quick response) for prompt, precise operation. The die cast frame is more streamlined and attractive than traditional sand cast frames. It is cast with a hex-shaped wrench boss to allow easy tightening from many angles, reducing assembly effort. This sprinkler is available in various finishes to meet many design requirements. recessed Sprinkler Operation: The operating mechanism is a frangible glass bulb which contains a heat responsive liquid. During a fire, the ambient temperature rises causing the liquid in the bulb to expand. When the ambient temperature reaches the rated temperature of the sprinkler, the bulb shatters. As a result, the waterway is cleared of all sealing parts and water is discharged towards the deflector. The deflector is designed to distribute the water in a pattern that is most effective in controlling the fire. Coverage: Residential spray coverage up to 20 feet 5 20 feet/6.1 m 5 6.1 m room sizes per NFPA. technical specifications: Exaggerated for Clarity Model: V3426 Style: Pendent and Recessed Pendent Nominal Orifice Size: 15 / 32 /12 mm K-Factor: 6.9 Imp./9.9 S.I.^ Nominal Thread Size: 3/4 NPT/20 mm Max. Working Pressure: 175 psi/1200 kpa Factory Hydrostatic Test: 100% @ 500 psi/3450 kpa Min. Operating Pressure: 7 psi/48 kpa Temperature Rating: See chart on page 2. MATERIAL SPECIFICATIONS Pendent Deflector: Bronze per UNS C51000 Bulb: Glass with glycerin solution. Bulb Nominal Diameter: Quick Response: 3.0 mm Load Screw: Bronze per UNS C65100 Pip Cap: Bronze per UNS C65100 Seal: Teflon* tape Frame: Die cast brass 65-30 ACCESSORIES Installation Wrench: Open End: V34 Recessed: V34 Sprinkler Finishes: Plain brass Chrome plated White painted** Custom painted** For escutcheons, cabinets and other accessories refer to separate sheet. ^ For K-Factor when pressure is measured in Bar, multiply S.I. units by 10.0. *Teflon is a registered trademark of Dupont Co. **UL Listed for corrosion resistance in all configurations. NOTE: Weather resistant recessed escutcheon available upon request. job owner contractor engineer System No. Submitted By Spec Sect Para Location Date Approved Date 1

recessed approvals/listings Model V3426 V3426 Orifice Size Inches mm Nominal K-Factor Response Deflector Type Imperial S.I.^ 15/32 6.9 12 9.9 15/32 6.9 12 9.9 Standard or Quick Approved Temperature Ratings Quick Pendent 1, 2, 3 A Quick Recessed Pendent Up to 3/4" Adjustment ^ For K-Factor when pressure is measured in Bar, multiply S.I. units by 10.0. Listings and approval as of printing. 1, 2, 3 A Approved temperature ratings Approval 1 C UL US A 155ºF/68ºC, 175ºF/79ºC Temperature Rating 2 NYC/MEA 3 CSFM MEA #62-99-E CSFM #7690-0531:112 _2

recessed ratings All glass bulbs are rated for temperatures from -67 F/-55 C to those shown in table below. Sprinkler Temperature Classification Ordinary Intermediate Victaulic Part Identification C E Nominal Temperature Rating Temperature ºF/ºC Maximum Ambient Temperature Allowed 155 100 68 38 175 150 79 65 Glass Bulb Color Red Yellow ordering information Please specify the following when ordering: Sprinkler Model Number Style Temperature Rating K-Factor Thread Size Quantity Sprinkler Finish Escutcheon Finish Wrench Model Number _3

recessed warning WARNING Always read and understand installation, care, and maintenance instructions, supplied with each box of sprinklers, before proceeding with installation of any sprinklers. Always wear safety glasses and foot protection. Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products. Installation rules, especially those governing obstruction, must be strictly followed. Painting, plating, or any re-coating of sprinklers (other than that supplied by Victaulic) is not allowed. Failure to follow these instructions could result in serious personal injury and/or property damage. The owner is responsible for maintaining the fire protection system and devices in proper operating condition. For minimum maintenance and inspection requirements, refer to the current National Fire Protection Association pamphlet that describes care and maintenance of sprinkler systems. In addition, the authority having jurisdiction may have additional maintenance, testing, and inspection requirements that must be followed. If you need additional copies of this publication, or if you have any questions about the safe installation of this product, contact Victaulic World Headquarters: P.O. Box 31, Easton, Pennsylvania 18044-0031 USA, Telephone: 001-610-559-3300. _4

recessed dimensions Standard Pendent V3426 2½ 63 mm 1¾ 44 mm 13 8 35 mm 23 8 60 mm Max Hole 2 51 mm Min. Hole 15 16 24 mm 5 8 16 mm TYPICAL CEILING TILE 17 8 47 mm FINISHED SURFACE 215 16 74 mm MAXIMUM EXTENSION ¾" Adjustment Recessed V3426 (drawing not to scale) 13 8 35 mm TYPICAL CEILING TILE 11 8 28 mm FINISHED SURFACE MAXIMUM RECESS _5

recessed available wrenches Sprinkler Type Open End Recessed V3426 Pendent V34 V34 V3426 Recessed Pendent V34 ROOM SIZE Victaulic V3426, 6.9 K-Factor Pendent Sprinkler For Ceiling types refer to NFPA 13, 13R or 13D 2013 Editions Max. Coverage Area (a) Ft. x Ft. m x m Ordinary Temp Rating 155 F/68 C Flow (b) GPM L/min Pressure (b) PSI bar Intermediate Temp Rating 175 F/79 C Flow (b) GPM L/min Pressure (b) PSI bar 12 X 12 20 8.4 20 8.4 3.7 X 3.7 75.7 0.58 75.7 0.58 14 X 14 20 8.4 20 8.4 4.3 X 4.3 75.7 0.58 75.7 0.58 16 X 16 20 8.4 20 8.4 4.9 X 4.9 75.7 0.58 75.7 0.58 18 X 18 20 8.4 20 8.4 5.5 X 5.5 75.7 0.58 75.7 0.58 20 X 20 22 10.2 22 10.2 6.1 X 6.1 83.3 0.70 83.3 0.70 Deflector to Ceiling 1 3/16 to 4 inch Installation Type ¾" recessed Escutcheon or non-recessed per NFPA 13, 13R or 13D Minimum Spacing (a) For coverage area dimensions less than or between those indicated, use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. (b) For NFPA 13 residential applications, the greater of 0.1gpm/ft 2 over the design area of the flow in accordance with the criteria in the table must be used. Ft. m 8.0 2.4 _6

recessed NOMINAL WETTING PATTERNS Model V3426 K6.9 residential and recessed 20 GPM/75.7 LPM 18 x 18 /5.5 x 5.5 m coverage area 8' 7' 2.1m 5' 1.5m 4' 1.2m 3' 0.9m 1' 0.3m 0' 4' 1.2m 8' 9' 8' 4' 1.2m 0' C L OF ROOM Model V3426 K6.9 residential and recessed 22 GPM/83.3 LPM 20 x 20 /6.1 x 6.1 m coverage area 8' 7' 2.1m 5' 1.5m 4' 1.2m 3' 0.9m 1' 0.3m 0' 4' 1.2m 8' 10' 8' 3.0m 4' 1.2m 0' C L OF ROOM NOTES: 1 Data shown is approximate and can vary due to differences in installation. 2 These graphs illustrate approximate wall-wetting patterns for these specific Victaulic FireLock Automatic Sprinklers. They are provided as information for guidance and should not be used as minimum sprinkler spacing rules for installation. Sprinkler location shall be in accordance with the obstruction rules for residential sprinklers in NFPA 13 (2002 or later revision). Failure to follow these guidelines could adversely affect the performance of the sprinkler and will void all Listings, Approvals and Warranties. 3 All patterns are symmetrical to waterway. _7

recessed warranty Refer to the Warranty section of the current Price List or contact Victaulic for details. note This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Updated 03/2013 4293 rev C