VENTURI Compact 300 NPWT Systems Choice of Therapy Modes Advanced Predictive Low Vacuum Alarm

Similar documents
V.A.C.RX4 USER MANUAL THERAPY SYSTEM. Rx Only

INFOV.A.C. USER MANUAL THERAPY SYSTEM. Rx Only

CircuFlow Quick Setup Guide

User Manual. December 2006 M Rev.A

Table of content Introduction... 2 Intended Use... 2 Indications for use of Vcare system... 5 Contraindications... 5 Clinical Guidelines of the Vcare

CBC II Blood Collection & Reinfusion System. Installation and use in Operating Room

Thopaz+ Quick Reference Guide. Precious life Progressive care

PRODUCT SAFETY DATA SHEET

Quick-Start Guide Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input Models and

Rocket Quick Guide. Rocket PSU Portable Suction Unit

ACTIV.A.C. User Manual THERAPY SYSTEM. For Patients and Clinicians. Rx Only

Cl inician Training Packet

Operating Instructions. Transair Alternating Pressure Care Mattress Replacement System

Section. 3: CADD Pump. Updated: June 20, Section Author(s): sstafford & jhval

VICTORIAN RESPIRATORY SUPPORT SERVICE AUSTIN HEALTH

The door can be opened with a RF card. The door can be opened with a transit RF card. Up to 20 cards be registered.

Operating Instructions. Transair Alternating Pressure Care Overlay System

HERCULES (110V) (220V) USER S MANUAL

P1195 DUAL TOURNIQUET MONITOR

v.a.c.simplicity TM Quick Reference Guide Power Connection Canister Battery Charging Light Control Panel

VICTORIAN RESPIRATORY SUPPORT SERVICE AUSTIN HEALTH

Hemovac Wound Drainage Family. The Time-Tested System for Reliable Wound Drainage and Auto-Transfusion

User Instruction Manual

Dryer Controller M720

Local Air Conditioner

USER MANUAL For Clinicians. Rx Only

NexSysLink. 2 CAN Display Operation Manual. CAN Instruments Product Family

User Manual. Dryer Controller M720

PORTABLE AIR CONDITIONER

PR-L2466W- PA. Operating Instructions. High Performance Refrigerator PR-L2466W-PA

7. Troubleshooting. General

2001 Smith Eastern Corporation

Owner's Manual. WS Series. Water Softener

DMWD 1 to 4 Zone Water Detection Alarm with Distance to Leak Measurement Installation and Operation Manual

Mini Rythmic PN+ Set-up Guide

Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input

NPWT PRO and PRO to GO PATIENT USER MANUAL

15,000 BTU Portable Air Conditioner

WEATHER FORECASTER WITH IN/OUT THERMO RADIO-CONTROLLED COLOR PROJECTION CLOCK - Ref.: RPM OWNER S MANUAL -

BRAVO AUTOCLAVES. Installation Notes. BRAVO 1 Quick Start Guide SD-402 Rev. 1.0 Copyright 2012 SciCan Ltd. All rights reserved

Compression therapy device & accessories Model 701A User manual

air conditioner/dehumidifier 9000btu/hr

DYGIZONE GJD910 Lighting Controller & Enunciator

CentriVap. Centrifugal Vacuum Concentrators and Cold Traps

WSK300 Multifunction Wall Control

Insight Operating Manual

Intelligent Security & Fire Ltd

R9968 ROBERTS. Analogue World Radio. Sound for Generations. Please read this manual before use

Alaris Syringe Module v9

MODEL 3X Series User s Manual

User Manual. Digi-Sense TC9500 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

CAREFULLY READ THESE INSTRUCTIONS BEFORE USING SAFETY PRECAUTIONS USE OF EXTENSION CORDS

Owner s Manual TABLE OF CONTENTS

Introduction... 3 Setup & Suggestions... 4 Basic Use... 4 Setting Time... 4 Setting Temperature... 5 Setting Height / Pressure...

Panel Functions & Indicators - Key to Icons General & Zone Fire LEDs ACCEPT SOUNDERS START/ STOP RESET BUZZER MUTE KEYSWITCH DELAY ON/OFF ITEM SELECT

Suits all KPF849 models

EVac II Programmable Digital Vacuum Gauge

CENTRIVAP CENTRIFUGAL CONCENTRATORS & COLD TRAPS

SERVICE MANUAL WASHING MACHINE

Checkout Procedure Manual

Analog Room Pressure Monitor RPC Series

Clinician Information

7. Troubleshooting. Description and Corrective Action. Low Pressure

TBR 40 1 GD Blood Refrigerator Instruction Manual. for BLOOD STORAGE REFRIGERATORS MODEL TBR 40 1 GD. (40 x 500ml Blood Bag Capacity)

SimplyGo Mini. User Manual REF R05 JH 08/01/2016 EN-INTL

Portable Air Conditioner User Manual

Introduction. OM-THA2

Water Softener & Single Tank Triple Treat System Installation Overview. Using 1850 Metered Valves

Syringe Pump. User Manual

Nellcor Bedside SpO 2 Patient Monitoring System, PM100N

Owner's Manual TABLE OF CONTENTS

Baros Comfort Turn Mattress

ELITE (110V) (220V)

PREASSEMBLED SURGICAL WASH SET FOR DIDECO ELECTA

Dehumidifier Owner s Manual Read and save these instructions before use

Owner's Manual TABLE OF CONTENTS

π H-3404 FoodSaver Vacuum Sealer

PORTABLE AIR CONDITIONER

ATMOS Medical Suction Systems

Installation. Leveling

Portable Air-conditioner

DC200 Digital Dispenser Operating Manual

TCA-9102 Series Surface Mount Temperature Controllers with High and Low Alarm

Alaris Syringe Module v9

Instruction manual. Please keep safe for future reference

HIn3550 Magnetic Field Monitor User's Manual

Model: Edge-HC. 1 edge-hc

Owners Manual Operating Instructions Patent # 7,081,811

SharperImage.com T.E.N.S. Massager with Handheld Control Operating Manual

Flowtron ACS900. Instructions For Use. ...with people in mind INT1 Rev A - 05/2015

Owner s Manual TABLE OF CONTENTS

SmartVent. Digital Controller User Guide Manual. NZ s Home Ventilation Specialists

T-32-TS Touchscreen Thermostat. Installation Manual

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCS. Voltage rating: 115V~60Hz Power rating : 1400W

A few simple steps to ensure perfect water, every time.

User guide User guide English

CDE2TI, CDE2TIB, CDE2ECC, CDE2ECCB, CDE24ECC & CDE24ECCB AUS/NZ

WASHING MACHINE SERVICE MANUAL

Portable Air-conditioner Use and Care Manual

JUNEAU JUN. 08/51193/0 Issue 0

Transcription:

VENTURI Compact 300 NPWT Systems Negative Pressure Wound Therapy (NPWT) is a mechanical wound care treatment that uses controlled negative pressure to assist and accelerate wound healing. VENTURI Compact 300 NPWT Systems are a clinically proven, cost effective option for the treatment of many wounds including pressure ulcers, dehisced surgical wounds, diabetic/ neuropathic ulcers, venous leg ulcers, post surgical wounds traumatic wounds and pre- and post-op flaps/grafts. The VENTURI COMPACT 300 versatile vacuum power units benefit from dual-power technology, offering a seamless choice of 110V or battery operation. The integral battery is chargeoptimized, and provides long-lasting power back-up when needed, in addition to allowing the systems to function away from a 110V supply, giving the patient full mobility during therapy. Ideally suited for mobile use, the VENTURI COMPACT weights around 2lbs. Choice of Therapy Modes The VENTURI power units deliver continuous negative pressure therapy with the option to select intermittent therapy, allowing the clinician to choose the most appropriate treatment for their patient. The system incorporates an autolock device to prevent accidental modification of therapy settings once treatment begins. Advanced Predictive Low Vacuum Alarm The VENTURI systems feature an advanced predictive low vacuum warning system which continuously monitors vacuum pressure, providing early detection of any environmental air leakage through the dressing which could dehydrate or contaminate the wound. Wound care set connection tubing features a turn and lock connector for secure attachment. Y-connectors available to allow for treatment of multiple wound sites. Integral canister sealing plug for secure containment of exudate prior to disposal. Large 600ml capacity of VENTURI AVANTI canister minimizes the frequency of canister changes. Smaller 300ml capacity of VENTURI COMPACT canister minimizes overall weight and dimensions of system for increased portability. Locking knob to secure canister to power unit and allow simple removal for canister changes. Carry bag supplied to allow patient full mobility during therapy. Bracket supplied with VENTURI COMPACT for versatile securing of unit during therapy PAGE 1

ASSEMBLY UNPACKING AND SETUP 1. Remove all packaging from the power unit and remove the piece of foam protecting the metal pins on the back of the canister prior to putting it on the unit. 2. If not already in place, attach canister to flat face of power unit by matching up the rear location pegs and rotating locking knob 1/4 turn clockwise to secure. Ensure canister is correctly located and secured otherwise NO CANISTER alarm will appear and power unit will not operate. 3. Prepare and seal wound as described in wound care set instructions. 4. Attach wound care set connection tubing to the VENTURI AVANTI / VENTURI COMPACT power unit canister by lining up locater stud on tubing connector with notch on canister tubing receptacle located on top corner of canister, twisting clockwise to lock. BUTTON FUNCTIONS RUN/STOP Press and hold this button for 3 seconds till a beep is heard and the Standby mode is obtained. Press again to run the power unit. To turn the unit off it first must be unlocked then press the button for 3 seconds until it beeps and returns to the Standby mode. In battery operation the power unit will then power off after one minute of inactivity. If using a main power source, turn off by disconnecting the power cable from the unit or turning off the power supply. VACUUM LEVEL The power unit will begin operation at the default pressure of 80 mm Hg. Vacuum level can be adjusted when in Standby mode for up to 1 minute after the last button operation when the power unit is running using the UP and DOWN arrow buttons. Pressure can be adjusted in 5mm Hg increments between 10mm Hg and 160mm Hg according to treatment requirements. The selected vacuum level is shown on the display screen. THERAPY MODE The VENTURI AVANTI / VENTURI COMPACT power unit offers a choice of continuous or intermittent therapy modes. On power-on, the power unit will default to continuous therapy mode. To switch between therapy modes,press and hold the THERAPY MODE button until power unit beeps to confirm change of mode. When in intermittent therapy mode, the power unit will provide vacuum therapy for periods of 5 minutes followed by a 2 minute rest period. The selected therapy mode is displayed on the power unit screen and can be altered in either stand-by or (unlocked) run modes. MUTE Press to silence alarm and to clear alarm display from display screen and to clear the unit memory. UNLOCK / LIGHT The VENTURI AVANTI / VENTURI COMPACT power unit will automatically lock 1 minute after last button operation when running to prevent inadvertent operation of button functions (except MUTE), as indicated by L on the display screen. Press and hold the UNLOCK button until power unit beeps if further button operation is needed (i.e. change of therapy mode or vacuum level, or returning power unit to stand-by mode). The power unit will lock again 1 minute after last button operation. Pressing this button will also illuminate the display screen for 10 seconds when operated on direct electric power. PAGE 2

OPERATING INSTRUCTIONS 1. If using the electric power supply, plug the smaller end of the power cable into the side of the VENTURI AVANTI / VENTURI COMPACT power unit, and the other end into mains outlet in wall. The battery will charge when the unit is connected to power (indicated by battery charge status icon on display screen scrolling from left to right) and provides automatic power back-up if mains power fails. It is recommended to use mains power when convenient to do so as this will ensure the battery is fully charged when needed. 2. Press RUN/STOP button to invoke and display STAND-BY mode (the unit will beep and therapy mode, operating pressure and battery charge status will be displayed). 3. The unit will default to continuous therapy mode at 80mmHg. To switch between continuous and intermittent therapy modes, press and hold the THERAPY MODE button until power units beeps to confirm change of mode. Adjust vacuum level if required using the UP and DOWN arrow buttons. 4. Press RUN/STOP button again to initialize and run the power unit. Vacuum level and therapy mode can be adjusted when in stand-by mode and for up to 1 minute after power unit is running. Power unit will automatically lock 1 minute after last button operation when running to prevent inadvertent operation of button functions (except MUTE), as indicated by L on the display screen. Press and hold the UNLOCK button until power unit beeps if further button operation is needed. Display screen is only illuminated for a short period after button operation in battery mode. 5. Once power unit is running, observe the wound site. The dressing should contract noticeably, become firm to the touch and raisin-like. If the dressing fails to contract, the dressing has not been completely sealed. 6. To change or remove dressing, unlock power unit (press and hold UNLOCK until power unit beeps), then press and hold the RUN/STOP button until power unit beeps three times to return to stand-by mode. Clamp wound care set tubing and remove by turning anticlockwise and lifting out of tubing receptacle on canister. Dispose of used wound care set according to local clinical waste policy. If required, apply new wound care set and continue NPWT. 7. Canisters should be replaced as required or weekly. To change canister, make sure power unit is in stand-by mode (if still running, press and hold the UNLOCK button, followed by the RUN/ STOP button). Clamp connection tubing and remove by turning anticlockwise and lifting out of tubing receptacle (this can be reconnected to new canister and unclamped if wound dressing is not being changed). Remove sealing plug from its location on top corner of canister and use to cap tubing receptacle to seal in contents. Rotate locking knob 1/4 turn anticlockwise and remove canister. Dispose of used canister according to local clinical waste policy. If continuing NPWT, attach new canister and connect wound care set tubing as previously described. 8. To stop the power unit, press and hold the UNLOCK button until power unit beeps and L clears from display screen. Then press and hold the RUN/STOP button until power unit beeps three times to return to stand-by mode. In battery operation the power unit will then power off after one minute of inactivity. If using mains power, switch off by disconnecting power cable from power unit or turning off main power 9. Place the user manual in a safe place for future use. PAGE 3

TALLEY QUICK FACT SHEET - BWOC (COMPATIBILITY MODE) BUTTONS Run/Stop 1. Press once to turn unit on 2. Unit goes into standby 3. Press second time to run 4. Press and hold to put unit back into standby 5. Shuts off automatically after 1 minute of inactivity in battery or off by pulling plug if using electric Vacuum Level 1. Up / Down Buttons 2. 10-160 mm 3. Begins at the default pressure of 80 mm unless set otherwise Therapy Mode 1. Default is continuous 2. To switch press and hold therapy button until unit beeps; button auto toggles to other setting 3. Auto set at on for 5 min low for 2 min. 4. Can be changed in standby or unlocked mode Mute 1. Silence alarms 2. Clears display screen. Unlock/Light 1. Auto-locks 1 minute after last button operation when running 2. L is indicated on the screen 3. Press and hold unlock button to unlock unit and go into standby 4. In battery, light on for 10 seconds only PAGE 4

TALLEY QUICK FACT SHEET - BWOC (COMPATIBILITY MODE) ALARMS LOW VACUUM 1. Unit will continue to operate 2. Press mute to silence/clear alarm 3. Alarm will reoccur till resolved 4. Disconnect tubing and cap tubing to unit; if alarm stops problem in dressing 5. Check edges of dressing and seal around connector 6. Seal as needed TUBE CONSTRICTED 1. Default alarm is on 2. Kink in tubing TILT ALARM 1. Alarm delays 5 seconds 2. Self muting when returned to upright position ATTACH CANISTER 1. Line up pegs with flat surface of unit 2. Turn knob ¼ turn 3. Connect tubing together CHANGING SETTINGS 1. Can only be done in standby setting after it has been unlocked 2. Changing pressure a. Put in standby b. Press the button c. Press the Run/Stop button to run 3. Changing therapy a. Put in standby b. Press and hold Therapy button until unit beeps which indicates unit in change mode c. Press Run/Stop DISPOSAL 1. Turn off unit 2. Clamp tubing 3. Remove tubing from canister 4. Remove cork from opposite side of canister and place in hole where tubing was 5. Dispose according to local bio-hazard rules USER SELECTABLE FUNCTIONS 1. To obtain menu press and hold unlock key 3 seconds PAGE 5