L62GB BASO Safety Shutoff Device

Similar documents
BGH Series Hot Surface Ignition Control

LGB Gas fired boiler

Q382A,B Pilot Burners

SERIES 35-63J APPLICATIONS FEATURES SPECIFICATIONS AGENCY CERTIFICATIONS

INSTALLATION AND OPERATION INSTRUCTIONS

Owner s Guide Installation & Operation

USER'S INFORMATION MANUAL

LGB. Control Supplement. Gas fired boiler. Universal Control System. Series 2 Propane gas. Contents

Owner s Guide Installation & Operation

JADE TACO RANGES MODEL: JTR and JTRB Series JADE STOCK POT RANGES MODEL: JSP Series

Commercial/Industrial Combustion Control Level Three Announcement

Cleaning Instructions for Burner, Pilot Assembly, and Emitter Screen. Series: LP Gas

Quick Reference Guide. Application. Gas Furnaces Boilers Water Heaters Commercial Cooking. Features

V SERIES HDR GAS RANGES

24 VAC Direct Spark Gas Ignition

READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

Owner s Guide Installation & Operation

S150 S300 CONSTRUCTION HEATERS. Rev: August 15, 2008 SERVICE AND MAINTENANCE MANUAL No PLEASE RETAIN FOR FUTURE REFERENCE PRODUCTS

USER MANUAL Gas Step Up Hot Plate

24 VAC Intermittent Pilot Gas Ignition Control

Installer: Leave this manual with the appliance. Consumer: Retain this manual for future reference.

Multi-Function Cooktop

21D83M-843 Integrated Single Stage Furnace Control Replacement Kit INSTALLATION INSTRUCTIONS

Panel Fan Series Operators Manual (Galvanized and Polymer)

CINCINNATI, OH USA

100% Safety Shutoff Control 40,000 BTUH Input Rating Constant Pilot Propane Gas

INSTALLATION AND OPERATION INSTRUCTIONS

SERIES VAC Microprocessor-Based Hot Surface Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION AGENCY CERTIFICATIONS

50M Integrated Single or Two-Stage HSI Integrated Furnace Control Kit INSTALLATION INSTRUCTIONS

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

Operator: Save these instructions for future use!

TRUERH Series HE-67xx Humidity Element with Temperature Sensor

CAUTION WARNING. 50T Integrated Furnace Control INSTALLATION INSTRUCTIONS DESCRIPTION PRECAUTIONS

Stone Hearth Pizza Dome Oven

Operator: Save these instructions for future use!

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

Installation/Operating Instructions

Packaged Gas/Electric Units. Owner s Guide to Operating and Maintaining Your Gas/Electric Unit

INSTALLATION AND OPERATION INSTRUCTIONS

OBSOLETE. Y8610U Intermittent Pilot Retrofit Kit GENERAL FEATURES PRODUCT DATA. Contents

Y8610U Intermittent Pilot Retrofit Kit

Pilot Burner and Direct Spark Ignition (DSI) Applications with Flame Rectification Sensing

USER'S INFORMATION MANUAL

Instruction Sheet LTR - Low Water Cutoff for Hot Water Boilers

YP7999A1000 ControLinks Fuel Air Ratio Control Panel

Fig. 1 - Unit PGD4, PGS4, WPG4

USER MANUAL Gas Countertop Charbroilers

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference)

SV9501/SV9502/SV9601/SV9602 SmartValve TM System Control

USER S INFORMATION MANUAL (2,4)SG13B

Y8610U Intermittent Pilot Retrofit Kit

DLCLRA. INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 TABLE OF CONTENTS

Applies to: Models F, B, FE, and BE FOR YOUR SAFETY

INSTALLATION AND OPERATION MANUAL GAS SKILLETS MODELS: GTS-30 GTS-40

GENERATION 2 QUADRATHERM Heater

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVN/P-400 INDIRECT FIRED SPACE HEATERS

Intermittent Pilot Ignition (IPI) and Direct Spark Ignition (DSI) Applications with Flame Current Probes

SERIES VAC Microprocessor-Based Intermittent Pilot Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

25M01A-100 to 25M01A-199 HSI Single Stage Combination Gas Valve

21 20 LITER GAS FRYER FFA3200 INSTALLATION AND SERVICING.

User s Information Manual

SV9520H SmartValve System Control Line Voltage Polarity Sense Models

ZG Shown READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

PANEL FAN SERIES OPERATORS MANUAL (Galvanized and Polymer)

SV9540; SV9640 SmartValve System Controls

USER'S INFORMATION MANUAL

Wilbur Curtis Company, Inc.

Operator: Save these instructions for future use!

Gas Conversion Kits and Instructions

Tankless Water Heater

Panel Fan Series Operators Manual (Galvanized and Polymer)

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) F-1000T DUAL FUEL CONSTRUCTION HEATER

SV9560/SV9570 SmartValve Water Heater Controls

Owner s Information Manual

INSTALLATION AND OPERATION INSTRUCTIONS

ULTRA-MAX GAS RADIANT CHARBROILER. ULTRA-MAX GAS LAVA ROCK CHARBROILER MODELS 8024CBB, 8036CBB, 8048CBB, 8060CBB, and 8072CBB

Residential Gas Hybrid Water Heater

THC 85 / 175 INDUSTRIAL / COMMERCIAL SPACE HEATER

USER'S MANUAL PGE Single Package Rooftop

A19, A28 Series Thermostats for Agricultural Buildings

50A Integrated Furnace Control

INSTALLATION INSTRUCTIONS

National Comfort Products 539 Dunksferry Road Bensalem, PA (215) Fax: (215)

Instruction manual Supplement

*Note: For operation at elevations above 2000 ft., appliance rating shall be reduced at the rate of 4 percent for each 1000 ft. above sea level.

USER S INFORMATION MANUAL

Operator: Save these instructions for future use!

INSTALLATION INSTRUCTIONS

User s Information Manual

Conversion Instructions Logano G234X. Gas boiler. Please read carefully before installing and servicing. Gas boiler

Failure to follow these instructions could result in fire or explosion which could cause property damage, personal injury or death.

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) F-400T DUAL FUEL CONSTRUCTION HEATER

THC-175DF INDUSTRIAL / COMMERCIAL SPACE HEATER. Certified to / Certifié à CGA 2.14 M2011 Conforms to / Conforme à ANSI std Z83.

STAR-MAX PROPANE GAS GRIDDLE

OPTIONAL THERMOSTATIC BLOWER ASSEMBLY No. SC18T

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVN/P-400 INDIRECT FIRED SPACE HEATERS

CYLINDER NOT INCLUDED

Installation Instructions

C6097A,B Pressure Switches

Operator s Manual CAYENNE GAS COUNTERTOP CHAR BROILER ENGLISH

Transcription:

Installation Instructions Issue Date August 18, 2008 L62GB BASO Safety Shutoff Device Installation IMPORTANT: Only qualified personnel should install or service BASO Gas Products. These instructions are a guide for such personnel. Carefully follow all instructions in this document and all instructions for the appliance. 4. Mount the L62GB in any convenient position using the mounting holes in the back of the case. 5. Push the circuit wires through the conduit opening on the side of the device, strip the ends of the wires just enough to put the bare wire under the terminal screws, and attach them to the two wire terminals. Shut off the gas supply at the main manual shutoff valve before installing or servicing the L62GB. Failure to shut of the gas supply can result in the release of gas during installation or servicing, which can lead to an explosion or fire, and may result in severe personal injury or death. Do not attach both wires to one terminal on the L62GB. Doing so bypasses and eliminates all safety features provided by the L62GB, can lead to an explosion or fire, and may result in severe personal injury or death. CAUTION: Risk of Electric Shock. Disconnect power supply before making electrical connections to avoid electric shock. IMPORTANT: Make all gas installations in accordance with applicable local, national, and regional regulations. To install the L62GB. 1. Turn off power to the appliance. 2. Turn off gas at the main manual shutoff valve adjacent to the appliance. 3. Remove the L62GB cover by loosening the screw on the front of the device. IMPORTANT: Do not loosen or tighten the brass hex nut that fastens the brass terminal bushing to the plastic switch housing. The machined flats on the terminal bushing must be parallel to the flats on the switch housing. If not, the switch power unit may distort and cause the safety switch to fail. Verify that this device is wired in series electrically with thermostats and other appliance operating controls. Wiring the device in parallel with such controls will defeat the safety features of this device and may result in severe personal injury or death. 6. Replace the cover. Do not loosen or tighten the brass hex nut. 7. Connect the pilot burner orifice fitting to the pilot outlet on the L62GB with 1/4 in. outside diameter tubing, and connect the pilot gas inlet with the gas manifold upstream from the automatic valve. Note: The pilot line connection is bidirectional as indicated by the arrows pointing in either direction. This provides the option of connecting the pilot gas inlet and outlet in either position. 8. Attach the thermocouple securely to the pilot burner, and screw the terminal end to the BASO power unit terminal on the L62GB. Make sure that this connection is clean. Tighten the thermocouple lead nut finger tight plus a maximum of 1/8 turn. Do not overtighten. 2008 BASO Gas Products. 1 Part No. BASO-INS-L62GB, Rev. A www.baso.com

X indicates possible locations for other controls. Power Unit Terminal L62GB BASO Safety Shutoff Device Power Source Thermostat Red Lever Transformer Main Manual Shutoff Valve ( A Valve) Pilot Gas Inlet Pilot Valve ( B Valve) Basotrol Valve "X "X 76.2 mm (3 in.) Sediment Trap Thermocouple Lead Pilot Gas Outlet Figure 1: Typical L62GB Installation Setup and Adjustments Checkout Verify that there are no gas leaks by testing with appropriate equipment. Never use a match or lighter to test for the presence of gas. Failure to test properly can lead to an explosion or fire and may result in severe personal injury or death. Make sure all components are functioning properly by performing the following test: 1. Test all joints and connections for leaks with a soap solution. 2. Set the thermostat to the lowest setting. 3. Close the main manual shutoff valve (A valve) and the pilot valve (B valve [see Figure 1]) and wait at least 5 minutes for unburned gas to escape from the appliance. 4. Reopen the B valve, push down the red lever and light the pilot burner. Continue to hold down the red lever for approximately 30 seconds. 5. Open the A valve. The main burner ignites from the pilot burner when the thermostat calls for heat. 6. Disconnect the thermocouple from the L62GB. The main valve should close immediately. If it does not close, check for wiring errors. Reconnect the thermocouple to the L62GB when it is operating correctly. 2 L62GB BASO Safety Shutoff Device Installation Instructions

7. Check the millivoltage output of the thermocouple and milliampere dropout range at the BASO power unit terminal to see that they meet the values in Table 1 and Table 2. Step-by-step procedures for these checks are included with the Y99AB BASO Test Kit. 8. Relight the pilot. 9. Observe at least three complete operating cycles to make sure that all components are functioning correctly. 10. Reset the thermostat to a normal temperature setting before leaving the installation. Repairs and Replacement Field repairs must not be made to the L62GB safety shutoff device. If the thermocouple meets the output listed in Table 1 and the valve does not function, replace the entire device. Any attempt to repair this assembly voids the manufacturer s warranty. For a replacement safety shutoff device, contact the nearest BASO Gas Productsdistributor. Check the millivoltage output of the thermocouple and milliampere dropout range at the BASO power unit terminal to see that they meet the values in Table 1 and Table 2. If the readings do not meet these values, replace the thermocouple and/or the safety shutoff device. Table 1: Thermocouple Output Thermocouple mv Range Lead Type Turn Not Less Down Normal Than K15 4 mv 20-28 15 K16 4 mv 25-35 17 K19 4 mv 25-35 17 Table 2: L62GB Dropout Range ma Range of Power Unit Assembly Low High 100 300 Pilot Servicing If pilot flame problems occur, check the following: If the pilot flame burns yellow, it may be due to dirt or lint covering the lower portion of the pilot burner. Remove dirt and lint using a soft brush or a vacuum cleaner. A flame approximately 0.5 in. (12.7 mm) high must surround the thermocouple tip (see Figure 2). Because this is an electrical connection, the thermocouple lead connection to the BASO power unit must be clean and free of grease. Approximately 1/2 in. (12.7 mm) Figure 2: Flame Position Replacement Procedure Shut off the gas supply at the main manual shutoff valve before installing or servicing the L62GB. Failure to shut off the gas supply can result in the release of gas during installation or servicing, which can lead to an explosion or fire, and may result in severe personal injury or death. CAUTION: Risk of Electrical Shock. Disconnect power supply before making electrical connections to avoid electrical shock. WARNING: Risk of Explosion, Fire, or Electric Shock. Label all wires before they are disconnected when replacing the L62GB. Wiring errors can cause improper or dangerous operation and may result in an electric shock, fire, or explosion leading to severe personal injury or death. When necessary, replace the safety shutoff device as follows: 1. Turn off power to the appliance. 2. Close the main manual shutoff valve and the pilot valve. 3. Disconnect the thermocouple lead from the safety shutoff device. 4. Remove the cover. L62GB BASO Safety Shutoff Device Installation Instructions 3

5. Disconnect and label the wires from the two wire terminals and remove the device from the appliance. 6. Remove the new L62GB cover by loosening the screw on the front of the device. Note: The L62GB may be mounted in any position by the mounting holes in the back of the case or by using the universal mounting plate supplied with the device. 7. Attach the universal mounting plate to the device when required (see Figure 3). Secure the mounting plate to the switch case with the sheet metal screws provided. The mounting plate is not required for exact replacements. Universal Mounting Plate 1 4 2 3 5 8. Mount the L62GB-3 using the holes in the universal mounting plate that match the mounting holes for the device being replaced (see Table 3). Table 3: Mounting Guide Switch Being Replaced Use Holes Numbered PENN (BASO) L62EA 1, 2, 3 PENN (BASO) L62GB-1 Plate Not Required Honeywell C591A 4, 5 ITT/General A100G653 4, 5 Note: Remove the L62GB cover for access to Holes 3 and 5. 9. Refer to Steps 5 through 8 in the Installation section complete the installation. 10. Perform the Checkout procedure before leaving the installation. BASO Power Unit Terminal Wire Terminals L62GB-3 Cover Figure 3: L62GB-3 Mounting 4 L62GB BASO Safety Shutoff Device Installation Instructions

Technical Specifications Product 100% Shutoff Yes Conduit Opening Switch Contacts Electrical Specifications Ambient Temperature Range Reset Switch Action Type of Gas L62GB BASO Safety Shutoff Device 2 (1 plugged) 24/25 VAC 125 VAC 250 VAC * 8 A 4 A -40 to 79 C (-40 to 175 F) Manual SPST Natural, Liquefied Petroleum (LP), manufactured, mixed, or LP gas-air mixtures Packaging Bulk pack supplied to original equipment manufacturer (individual pack optional). L62GB-3 supplied as individual pack only. Bulk Pack Quantity 30 Weight 32 lb (14.5 kg) Agency Listings CSA Certificate Number 229521-1656085 Specification Standards ANSI Standard Z21.20 CAN1-6.4 * Switch can be used on 24/25 VAC installation. Performance specifications are nominal and conform to acceptable industry standards. All agency certification of BASO products is performed under dry and controlled indoor environmental conditions. Use of BASO products beyond these conditions is not recommended and may void the warranty. Product must be protected if exposed to water (dripping, spraying, rain, etc.) or other harsh environments. The original equipment manufacturer or end user is responsible for the correct application of BASO products. Consult BASO Gas Products LLC for questionable applications. BASO Gas Products LLC shall not be liable for damages or product malfunctions resulting from misapplication or misuse of its products. Refer to the L61, L62 Series BASO Safety Shutoff Device Product Bulletin (BASO-PB-L61/L62) for necessary information on operating and performance specifications of this product. 1007 South 12th Street PO Box 170 Watertown, WI 53094 www.baso.com 1-877-227-6427 (1-877-BASOGAS) Published in U.S.A. L62GB BASO Safety Shutoff Device Installation Instructions 5