Sita200plus. 200detectors. Single loop analogue addressable System

Similar documents
INTELLIGENT FIRE TECHNOLOGY

The new detector from Rafiki

System 800 Addressable Fire Detection & Alarm System

FIRE ALARM SOLUTIONS THAT FIT YOUR NEEDS

ZIOU/230 - MAINS IO INSTRUCTION MANUAL

Intelligent addressable fire alarm control panel

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

Overview. Wireless Overview QLD NSW VIC Fundamentals. Operation. Features.

Solution F2. Fire Alarm Control Panels one step ahead.

Intelligent Security & Fire Ltd

Excel-EN Conventional Fire Control Panel

Control Panel User Guide

MINERVA MZX125 Digital Addressable Fire Detection System

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

Control Panel User Guide

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

Addressable and Conventional Fire Protection

Installation, Operating and Maintenance Manual

TECHNICAL DATA SHEET ADDRESSABLE FIRE ALARM SYSTEMS FIRE ALARM CONTROL PANEL LF-6100 A 1/2

P R O D U C T D ATA S H E E T

Intelligent Security & Fire Ltd

MINERVA MZX125. Digital Addressable Fire Detection System

OPERATION AND INSTALLATION MANUAL

Evolution Analogue Addressable Fire System

Industries. As a premier global manufacturing company, we believe that great brands are

Intelligent 2 & 4 Loop Fire Alarm Control Panels

An introduction to... Sigma

LF /2. Fire Alarm Control Panel. Features:

Intelligent Single Loop Fire Alarm Control Panel

PANELS, KEYPADS & MODULES. Take Fire Protection to the Next Level Fire Products from DSC

INDEX 1- Introduction The Control Pane...7l 4.1- The Control Panel 1 and 2 Loops The Control Panel 4 and 8 Loops...

Algo-Tec 6300 INTERACTIVE DIGITAL ADDRESSABLE FIRE CONTROL SYSTEM (1-4 LOOPS)

JUNO-NET. Fire Alarm Control Panel OPERATION & MAINTENANCE MANUAL

intelligent fire alarm ID60series panels

Control Panel Engineering and Commissioning Manual (TO BE RETAINED BY THE COMMISSIONING ENGINEER)

EFBW series - BiWire Ultra control panel

ZXSe Range Data Sheet

Wireless Fire & Security Solutions. Fire Product Showcase

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

Control Panel User Guide (TO BE RETAINED BY THE USER)

Fire Product Catalog

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

1) This manual covers 4400, 5400 and 6400 fire alarm systems. The differences are described in the appropriate sections.

C E R T I F I C AT LPCB I O N B O A R D P R E V E N T L O S S. Cooper Fire Systems

ZXSe Range. Fire Safety. Analogue addressable fire alarm control panel KEY FEATURES. Panel Features

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

INPUT / OUTPUT MINI MODULES

SALES SUPPORT DOCUMENT

Control Panel Engineering and Commissioning Instructions

NZ 400 AUTOMATIC FIRE ALARM SYSTEM OPERATORS MANUAL

Installation and Operating Instructions

MINERVA. Marine. Fire Detection. MX T2000 Panel Range. Features: MINERVA Marine Panel Range

Algo-Tec 6500/6600 INTERACTIVE DIGITAL ADDRESSABLE FIRE CONTROL SYSTEM (1-4 LOOPS)

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

MINERVA MX. 800 Series Ancillary Equipment

FDMM01S - FDMM02 - FDMM10- FDMM11S FDMM12 - Input / output mini modules

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

Maintenance Guide EMS Security Group Ltd. All rights reserved. MK154 Iss5 18/11/15 AJM

INTELLIGENT FIRE TECHNOLOGY. Twinflex and Multipoint V3. User Guide (TO BE RETAINED BY USER) Issue 3

Protec. Protec Algo-Tec TM 6500 Interactive Digital Addressable Fire Control System with Algo-Tec 6600 Bridging Network. Fire Detection - Addressable

BT1 SINGLE ZONE FIRE ALARM SYSTEM OPERATORS MANUAL

Saxon Range 1-8 Zone Convertional Control Panels

Discovery 1-4 Loop 32 Zone, 40 Character Analogue Addressable Control Panel. Application Guide

Control Panel Engineering and Commissioning Manual (TO BE RETAINED BY THE COMMISSIONING ENGINEER)

1200-HCM DIN RAIL MOUNTING FIRE SYSTEM MODULE Fire Detection & Extinguishant Control A R T PATOL LIMITED SUPPLY FAULT SOUNDER

The EN54 Part 2 and 4 Fire System

Advanced FireAlarm Panel 1-4Loop

The EN54 Part 2, 4 and 13 Fire System

Protec. Protec Algo-Tec TM 6500 Open Protocol Interactive Digital Addressable Fire Control System with Algo-Tec 6600 Bridging Network

HART XL High Sensitivity Smoke Detection

HART XL High Sensitivity Smoke Detection

BiWire Flexi. BiWire Flexi Fire Panel EFBW8ZONE-FLEXI / EFBW4ZONE-FLEXI / EFBW2ZONEFLEXI Installation Manual

Discovery 1-4 Loop 96 Zone, 40-Character Analogue Addressable Control Panel. Application Guide

Syncro Matrix Analogue Addressable Fire Alarm Mimic Panel Product Manual

Fire and Smoke Control Systems

Addressable Carbon Monoxide Detection, Monitoring & Ventilation System

ID50series. intelligent fire alarm panels

Control Panel Engineering and Commissioning Manual (TO BE RETAINED BY THE COMMISSIONING ENGINEER)

Discovery 4 Loop Analogue Addressable Control Panel (NVI & NVA series Protocols)

The complete conventional fire warning system

UL Systems. UL intelligent addressable systems Product Name

STANDARD TECHNICAL SPECIFICATION FOR AN ANALOGUE ADDRESSABLE FIRE DETECTION SYSTEM

SECURIT 700L PLUS ENGINEERING MANUAL

INTELLIGENT FIRE ALARM CONTROL PANEL

SUPREMATouch. Modular Fire & Gas Detection System

Scope. Warning sounders except specific requirements. Intercom Systems for Emergency Purposes. Sound Systems for Emergency Purposes

user manual Document No , Revision 03 November 2015

6100 SINGLE LOOP DIGITAL ADDRESSABLE FIRE ALARM CONTROL PANEL

Fire Alarm Control Panel. System Maintenance and Log Book

CONVENTIONAL FIRE CONTROL PANELS FS 5100 and FS 5200

Analogue addressable devices

SIMPLICITY CO CARBON MONOXIDE DETECTION & VENTILATION PANEL

FC700A Fire detection control unit

four Vigilon Compact Analogue Addressable Fire Detection & Alarm System 4/1

IntelliKnight 5820XL Addressable Fire Alarm Control System Sales Guide

SOLO Single Loop Addressable Fire Control Panel

Addressable Fire Alarm Control System 2100 series

Reliably Advanced Extinguishing Control

Conventional Fire Detection

Transcription:

Single loop analogue addressable System Fast short circuit isolator in every device 15 combinations of smoke & heat detection modes Loop length up to 2km long with spurs INTELLIGENT FIRE TECHNOLOGY

A D D R E S S A B L E F I R E D E T E C T I O N Sita200plus Addressable intelligent detector system With the Sita 200 plus System a high technology approach has been adopted, with a microcomputer in each device implementing a large degree of distributed intelligence. The system can support 200 Multipoint combined detector/sounders on a single loop. Each one not only provides detection, but also a built in sounder. Certificate number 331 C/01 Integrity of the system is maintained by way of a built-in isolator in every device. Sita system intelligence has been harnessed in such a way that equipment used is very easy to install, commission and maintain. The system has been designed to high specification and quality standard, and is intended to fully comply with the new EN54 2 and EN54 4 standards and EU directives. Sita 200 plus offers all of these features: Fast short circuit isolator in every device 15 combinations of smoke & heat detection modes Loop length up to 2km long with spurs Digital communication with high power transfer 32 programmable detection/alarm zones Multi stage alarms pre alarm feature Very low current consumption 7 sound patterns plus off, 3 different volume settings Control panel has 32 zonal displays for fire Automatic continuous self calibration Addressable Multipoint detector is monitored for all failures of sensor chamber warning is indicated when a smoke detector head requires servicing Control panel has integral power supply with intelligent battery management Repeater units available connected on a bi-directional serial data link Zones 17 to 32 can be assigned as auxiliary zones Soft addressing Full range of loop driven sita compatible products available including call points, call point sounders, stand alone sounders, sounder beacons, I/O interface units and weatherproof items.

Spurred device 200 Heat Detectors, 200 Smoke Detectors, 200 Sounders and 200 I/O s on a single loop Built in isolator in every device Pre alarm features Soft addressing 15 detection modes Up to 200 conventional call points can be spurred from each device Loop length 2 Km) Beam Detector Sita Flash point Sita Soundpoint Weatherproof Sita Loop Conventional Interface Sita Callpoint Sita Panel Sita Bell Sita Repeater Panel Sita Callpoint Detector/Strobe Sita Soundpoint Weatherproof Detector/Strobe Sita Hipoint Sita Soundpoint Smoke is detected in one room of an apartment 4 OPTIONS TO CHOOSE The sounder in that detector will sound for 30 seconds. All the sounders in that zone will sound for 30 seconds The sounders in a linked zone will sound for 30 seconds ie. caretaker The display may show an optional warning showing the location of incident. SMOKE CLEARS SMOKE REMAINS If smoke disappears, all sounders will silence automatically within 30 seconds If the smoke is still present the sounders will continue to sound as above. SMOKE REMAINS SMOKE CLEARS The above process will continue for a predetermined time (1-7.5 Minutes). If smoke is detected after this time, and up to 10 minutes from the start. If at any time during Alarm-Confirmation, a second detector detects smoke. If there is no smoke in the room between predetermined time and 10 min FULL ALARM Or any required actions programmed The alarm is reset automatically and only the occupant in one apartment is disturbed! If a call point or heat detector is activated before, during or after the Alarm Confirmation then the system will activate the alarms immediately.

C O N T R O L P A N E L The Sita SINGLE LOOP panel has a maximum loop length of 3.2km (2 miles) fully loaded! The loop has a maximum capacity of 200 detectors and 200 sounders. Sita utilises soft addressing and can be configured via a PC. The system itself operates on a distributed intelligence basis where signal processing and fire decisions are made within the local device. Activity of devices is displayed individually on the panel LCD. The panel provides a set of monitored inputs and outputs that can be configured to perform a range of functions. The repeat link on the Sita panel enables up to 4 repeater units to be connected. The system may be configured to utilise up to 3 alarm stages with full Cause & Effect programming across all 32 zones and the option of 7 different sound patterns. The Sita panel is compliant with EN54-2 and EN54-4 and EU directives. Digital communication with high power transfer Alarm confirmation as standard Technical specifications Compatibility: Sita 200 plus Construction: Front: V2 rated ABS Back box: Mild Steel Operating Temperature: 5 C to 33 C Voltage Range: 16 to 48v DC Main voltage: 230v AC +10% -15% Panel Inputs/Outputs: 2 x monitored sounder/relay circuit 1 x common fire relay 1 x common fault relay 2 x fire input (latching/non latching) 1 x R-bus (Repeater and PC link) Loop voltage: 40v DC Current Consumption: Max loop current: 500mA Quiescent: 25µA Alarm: 48mA Battery Requirements: 48hr: 2 x 3.3Ah 12v Loop Length: 3.2Km 2 core 1.5mm (with screen/earth) Part Code: 503 0001 Advanced PC configuration tools Very low current consumption 32 zonal displays for fire Integral power supply with intelligent battery management W:318 mm Repeater units available - connected on a bi-directional serial data link H:318 mm D:72 mm D:27 mm

A D D R E S S A B L E F I R E D E T E C T I O N Sita200plus R E P E A T E R P A N E L The Sita Repeater panel provides additional indication and control for your system The Sita repeater panel utilises a 2 core screened fire cable for data transmission, and will operate up to 4 repeater panels. The panel gives full text and led indication of events taking place, and provides system controls for Alarms On/Off and Reset System. The repeater panel housing is similar to the main control panel, allowing flush or surface mounting, complete with integral PSU and battery compartment. Technical specifications Compatibility: Sita 200 plus Construction: Front: V2 rated ABS Back box: Mild Steel Operating Temperature: 5 C to 33 C Mains voltage: 230v AC +10% -15% Panel Inputs/Outputs: 1 x common fire relay 1 x common fault relay 1 x R-bus (Repeater and PC link) Battery Requirements: 2 x 3.3Ah 12v Part Code: 503 0002 W:318 mm H:318 mm D:72 mm D:27 mm

Rafiki Protection Limited 31 Springvale Industrial Estate Cwmbran NP44 5BD United Kingdom T: +44 (0) 1633 865558 F: +44 (0) 1633 866656 rafikisales@rafiki.biz www.rafiki.biz Issue 1