CERTIFICATE OF FIRE APPROVAL

Similar documents
CERTIFICATE OF FIRE APPROVAL

CERTIFICATE OF FIRE APPROVAL

GUIDELINES FOR THE APPROVAL OF EQUIVALENT FIXED GAS FIRE-EXTINGUISHING SYSTEMS, AS REFERRED TO IN SOLAS 74, FOR MACHINERY SPACES AND CARGO PUMP-ROOMS

26 June 2001 *** I:\CIRC\MSC\1007.DOC INTERNATIONAL MARITIME ORGANIZATION 4 ALBERT EMBANKMENT LONDON SE1 7SR

CERTIFICATE OF FIRE APPROVAL

Notice No. 7. Rules and Regulations for the Classification of Ships, July Issue date: March Working together for a safer world

EC TYPE EXAMINATION (MODULE B) CERTIFICATE

Requirements for ships carrying hydrogen and compressed natural gas vehicles

FirePro ANNEX 1 MARINE MANUAL. Version 1,

NFPA 2001: Standard for Clean Agent Fire Extinguishing Systems NFPA 70: National Electrical Code (NEC) NFPA 72: National Fire Alarm Code

USCG-EU MRA EC TYPE EXAMINATION (MODULE B) CERTIFICATE

Notice on the implementation of the amendments to the FSS Code in resolution MSC.339(91)

ClassNK Technical Information No. TEC-0453 Attachment (1) to ClassNK Technical Information No. TEC-0453 Guidance on SOLAS Chapter II-2 as amended in 2

USCG-EU MRA EC TYPE EXAMINATION (MODULE B) CERTIFICATE SAMPLE

THE REPUBLIC OF LIBERIA LIBERIA MARITIME AUTHORITY

SPECIFICATION: Kidde Engineered Fire Suppression System Designed for use with 3M Novec 1230 Fire Protection

BMA INFORMATION BULLETIN No. 97 FIRE FIGHTING EQUIPMENT

Attachment 1. to ClassNK Technical Information No.TEC-0764 Malta Maritime Authority Date Revised 28 August 2008 Page 1 of 10 This Administration Requi

EC TYPE EXAMINATION (MODULE B) CERTIFICATE

SPECIFICATION: ECS SERIES CLEAN AGENT FIRE SUPPRESSION SYSTEM

Lloyd s Register Type Approval System Test Specification Number 3

A. NFPA 2001 Standard for Clean Agent Fire Extinguishing Systems 2004 edition.

EC TYPE EXAMINATION (MODULE B) CERTIFICATE

***** 2. Rev.1 is to be uniformly implemented by IACS Members from 1 July 2004.

Technical Information

EU DECLARATION OF CONFORMITY (Doc) issued in accordance with the MARINE EQUIPMENT DIRECTIVE (MED) and EU/US MRA

Only the Danish version is authentic Notice D II-2 N(2) 1 October 2002 CHAPTER II-2 N(2)

IMO FP 53 Report. Lloyd s Register report on the 53 rd session of IMO Fire Protection Sub-Committee. 16 th March, 2009

POSITION PAPER ON WATER MIST FOR FIRE FIGHTING APPLICATIONS

MGN 453 (M) Maritime and Coastguard Agency Logo MARINE GUIDANCE NOTE

OFFSHORE SUPPORT VESSELS 2014

PROCEDURES FOR APPROVAL OF LIFE-SAVING APPLIANCES AND FIRE SAFETY SYSTEMS, EQUIPMENT AND PRODUCTS

Australian Standard. Water mist fire protection systems System design, installation and commissioning AS

DRY CHEMICAL POWDER SYSTEM REQUIREMENTS TO COMPLY WITH THE LATEST IMO IGC CODE AND EUROPEAN COUNCIL CLARIFICATIONS

Hospitals and Major Medical Centers

MSC Guidelines for Automatic Sprinkler Systems

SPECIFICATION: ARGONITE Engineered Fire Suppression System

INTERNATIONAL STANDARD

SPECIFICATION: CARBON DIOXIDE ENGINEERED FIRE SUPPRESSION SYSTEM

Foam Concentrates Test and Fire Test

(2) Various fire sections enclosed by various classes of fire divisions; (3) Arrangement of fire detectors and manual fire alarm stations;

SECTION FM-200 FIRE SUPPRESSION SYSTEM

ENHANCED FIRE PROTECTION ARRANGEMENTS

RADAR REFLECTOR STANDARD FOR CERTIFICATION. DET NORSKE VERITAS Veritasveien 1, N-1322 Høvik, Norway Tel.: Fax:

ADDITIONAL FIRE PROTECTION (F-AMC)

RESOLUTION MSC.217(82) (adopted on 8 December 2006) AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS

MARINE GYRO COMPASS STANDARD FOR CERTIFICATION. DET NORSKE VERITAS Veritasveien 1, N-1322 Høvik, Norway Tel.: Fax:

RESOLUTION MSC.98(73) (adopted on 5 December 2000) ADOPTION OF THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS

MSC Guidelines for Foam Fire Suppression Systems

RESOLUTION MSC.292(87) (adopted on 21 May 2010) ADOPTION OF AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS

Iranian Classification Society Convention and Legislation Department Code: Tech Contents

EC TYPE EXAMINATION CERTIFICATE

Kidde Nitrogen Inert Gas Clean Agent Fire Suppression System

Section C-2 of the Gas Regulations

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 1 GENERAL

RESOLUTION MSC.339(91) (adopted on 30 November 2012) AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE)

MARINE CIRCULAR MC-7/2011/1

Order on fixed CO 2 fire-extinguishing systems 1

STANDARDS FOR VAPOUR EMISSION CONTROL SYSTEMS ( MARPOL reg VI/15 )

MSC Guidelines for Watermist Fire Suppression Systems Procedure Number: E1-03 Revision Date: 02/16/2017

IACS RESOLUTION CHANGES (GMO ) BEKİR SITKI TÜRKMEN

KD Innovative extinguishing with Novec TM 1230 by 3M TM

Australian Standard. Gaseous fire extinguishing systems AS (Incorporating Amendment No. 1) AS

IMO INTERPRETATIONS OF FIRE PROTECTION-RELATED PROVISIONS OF THE HSC CODE

GUIDELINES FOR THE APPROVAL OF HELICOPTER FACILITY FOAM FIRE-FIGHTING APPLIANCES

BOC FS125 The Fire Extinguishing Solution

SPECIFICATION: DRY CHEMICAL FIRE SUPPRESSION SYSTEM FOR INDUSTRIAL APPLICATIONS MODEL IND

C-01 FIRE DECKS AND BULKHEADS

INTERNATIONAL STANDARD

CLEAN AGENTS Updates to the NFPA 2001 Standard on Clean Agent Fire Extinguishing Systems 2015 Edition

GUIDE TO APPROVAL OF RETROFIT BALLAST WATER MANAGEMENT SYSTEM INSTALLATIONS

ClassNK Technical Information No. TEC-0838 (iii) The dormant period, visual indication, first stage audible alarm, second stage remote audible alarm a

Additional Fire Protection (F-AMC)

EC Type Examination Certificate

MAINTENANCE AND INPSECTION OF FIRE PROTECTION SYSTEMS AND APPLIANCES

3M Novec 1230 Fire Protection Fluid For Marine Applications. Created. Life. for

IMO CCC1 Summary Report on the developments of the IGF Code

First Revision No. 20-NFPA [ Section No ]

GASEOUS HYDROGEN SYSTEMS

AMENDMENTS NO. 3/2012 to

EU CERTIFICATE OF CONFORMITY

IMO DEVELOPMENT OF MODEL PROCEDURE FOR EXECUTING SHIPBOARD EMERGENCY MEASURES. Fire-fighting drills. Submitted by the Republic of Korea

ISO INTERNATIONAL STANDARD. Ships and marine technology Fire-extinguishing systems for protection of galley cooking equipment

Attachment 1. to ClassNK Technical Information No. TEC-1077 Isle of Man Ship Registry Manx Shipping Notice SOLAS II-2 The Maintenance and inspection o

IMO. Resolution A.951(23) Adopted on 5 December 2003 (Agenda item 17) IMPROVED GUIDELINES FOR MARINE PORTABLE FIRE EXTINGUISHERS

Global Requirements for the Fire Protection of Ships. Dr Janet Murrell Warrington Certification Ltd

Government of Bermuda Bermuda Shipping and Maritime Authority BERMUDA SHIPPING NOTICE

RESOLUTION MSC.44(65) (adopted on 11 May 1995) STANDARDS FOR FIXED SPRINKLER SYSTEMS FOR HIGH SPEED CRAFT

Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K Upright, and Pendent Extended Coverage Light and Ordinary Hazard General Description

International Water Mist Conference, Istanbul October 22-23, 2014 The background and development of the guidelines in IMO Resolution A.

REPORT NUMBER: SAT-001B ORIGINAL ISSUE DATE: February 29, 2016 REVISED DATE:

REVISED GUIDELINES FOR THE DESIGN AND APPROVAL OF FIXED WATER-BASED FIRE-FIGHTING SYSTEMS FOR RO-RO SPACES AND SPECIAL CATEGORY SPACES


Certificate of Compliance

This document is a preview generated by EVS

GROUNDING AVOIDANCE SYSTEM (GAS)

Fire Detection and Alarm System (FDAS) & Fire Detection and Suppression Systems (FDSS) for Buses - Requirements

IMO. Resolution A.952(23) Adopted on 5 December 2003 (Agenda item 17) GRAPHICAL SYMBOLS FOR SHIPBOARD FIRE CONTROL PLANS

Introduction. There is no obligation to follow the methods or comply with the standards set out in this Technical Booklet.

Survey of electrical equipment installed in hazardous areas on tankers

Transcription:

CERTIFICATE OF FIRE APPROVAL This is to certify that The product detailed below will be accepted for compliance with the applicable Lloyd s Register Rules and Regulations and with the International Convention for the Safety of Life at Sea, (SOLAS), 974, as amended, for use on ships and offshore installations classed with Lloyd s Register, and for use on ships and offshore installations when authorised by contracting governments to issue the relevant certificates, licences, permits etc. Manufacturer Address Type Description Specified Standard Kidde - Fenwal Inc. 400 Main Street Ashland MA 072 United States of America (USA) FIXED GAS FIRE EXTINGUISHING SYSTEM Fixed Fire Extinguishing System Type: Kidde ECS ADS Series Marine System with 3M Novec 230 Fire Protection Fluid for Machinery Spaces of Category A and Cargo Pump Rooms equivalent to Fire Extinguishing Systems required by SOLAS 974 as amended, Chapter II-2/0.5 and 0.9. In addition the system may be used in the cargo compressor and pump rooms of LNG and LPG carriers. IMO MSC/Circ. 848 as amended by MSC./Circ.267 and MSC./Circ.36 The attached Design Appraisal Document forms part of this certificate. This certificate remains valid unless cancelled or revoked, provided the conditions in the attached Design Appraisal Document are complied with and the equipment remains satisfactory in service. of issue Expiry date 28 September 2020 Certificate No. Signed Fire & Safety, MTES Lloyd's Register EMEA LR427.203.2 Sheet No of 6 Name M. Farrier Surveyor to Lloyd s Register EMEA A Member of the Lloyd s Register Group Note: This certificate is not valid for equipment, the design or manufacture of which has been varied or modified from the specimen tested. The manufacturer should notify Lloyd s Register of any modification or changes to the equipment in order to obtain a valid Certificate. Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause as the 'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

2 of 6 ATTACHMENT TO CERTIFICATE OF TYPE APPROVAL No. This Design Appraisal Document forms part of the Certificate. APPROVAL DOCUMENTATION Underwriters Laboratory of Canada, Test Report No. EX 4674, dated February 2005 and Lloyd's Register witness report, dated 26 October 2004. Additional component testing in test report No. EX 4674 dated November 204. Additional new nozzle tell-tale testing report UL Project No.478609874, File EX 4674, Edition 2, dated 25 July 203. FM Approvals, Norwood, USA, Report PI 3026502, dated 24 March 2006. Kidde-Fenwal Inc. and U.S. Coast Guard. CRADA, No. 04-CRADA-RDC-00, dated 6 November 2004. CONDITIONS OF CERTIFICATION. The National Authorities of the vessel concerned are to accept the use of NOVEC 230 as being acceptable for compliance with The International Code for Fire Safety Systems (Fire Safety Systems Code), Chapter, paragraph 4 and Chapter 5, paragraph 2.5 at the design stage. Should the system be installed in the cargo compressor and/or pump rooms of LNG or LPG ships the National Authorities of the vessel concerned are to accept the use of NOVEC 230 for this application. The manufacturers of the system are to advise, whoever they are contracted to, of this requirement at the earliest opportunity 2. If the system is to be of the modular type, i.e., with both the NOVEC 230 cylinders and associated separate nitrogen cylinders distributed within the machinery space, the National Authorities are to accept the arrangements with due reference to the Fire Safety Systems Code, Chapter 5, paragraph 2...4 and MSC/Circular 848, paragraph of the Annex, as amended by MSC./Circ 267. All other requirements specified in the Fire Safety Systems Code, Chapter 5, as amended by later IMO revisions of the Code are to be applied at the system design stage 3. The computation of the discharge time for each application is to be produced by the Kidde Fenwal program Flow Calculation Software Users Guide 06-237256-004 dated 204 and is to be independently verified at the design stage. The system should be designed so that 95% of the extinguishing agent can be discharged in 0 seconds. The flow calculation program shall be applied for balanced systems where the storage temperature range is 0 C - 54 C 4. The quantity of Novec 230 for the protected space is to be calculated at the minimum expected ambient temperature (which is to be no greater than zero degrees Celsius) with a minimum design concentration of 5.85%. The maximum concentration is not to exceed 0% (LOAEL Limit) at the maximum expected ambient temperature, (not less than 50 degrees Celsius). Other temperature ranges may be considered on a project by project basis, subject to agreement by the National Administration. Where the system is installed in the cargo compressor and/or pump rooms of a Liquefied Natural Gas carrier, the minimum design concentration of the extinguishing agent is to be 7.2% based on an operating temperature of 20 degrees Celsius and amended to reflect any lower operating temperature of the space

3 of 6 ATTACHMENT TO CERTIFICATE OF TYPE APPROVAL No. 5. Where the system is installed in the cargo compressor and/or pump rooms of a Liquefied Petroleum Gas carrier, the minimum design concentration of the extinguishing agent is to be 6.5% based on an operating temperature of 20 degrees Celsius and amended to reflect any lower operating temperature of the space 6. The design concentration is to be based on the net volume of the protected space, including the casing, the bilge and the volume of free air contained in air receivers that in the event of a fire, is released into the protected space. All objects that occupy volume in the protected space should be subtracted from the gross volume of the space. They include, but are not necessarily limited to: auxiliary machinery, boilers, condensers, evaporators, main engines, reduction gears, tanks and trunks 7. The discharge of NOVEC 230 is to be evenly distributed over the protected space and the nozzle spacing is not to exceed 5 metres for a 360-degree (ADS 360) nozzle or 0 metres for a 80-degree (ADS 80) nozzle or equivalent nozzle coverage arrangement. The maximum nozzle vertical spacing is not to be greater than 5 metres 8. The pressure at each nozzle is to be a minimum of 5.5 bar, at a maximum cylinder fill density of 2 kg/m³, for nozzle types: ADS 360 and ADS 80. The drill sizes of each nozzle orifice, nozzle part numbers and the quantity of agent to be discharged from each nozzle is to be determined by the flow calculation program. Nozzles to be manufactured from ASTM B6 Brass or stainless steel 9. 0% of the distribution piping is to be pressure tested to.25 times the maximum pressure likely to be experienced in service. For NOVEC 230 systems, this equates to.25 x 28 bar (at 54 C) = 35 bar. 0. For systems with NOVEC 230 cylinders stored outside the protected space, with a manifold and distribution valve(s). The manifold pipework is to be tested to at least.5 times the setting of the manifold relief valve. The manifold relief valve is to be set at a minimum pressure of 35 bar and the minimum manifold test pressure is to be 53 bar. The NOVEC 230 cylinders should be suitably designed to be pressure tested at least.5 times the pressure at the maximum temperature of the space in which they are stored, this equates to.5 x 28 bar (at 54 C) = 42 bar. The manufacturer pressure tests NOVEC 230 cylinders at 69 bar for this system. The system also includes nitrogen cylinders at a nominal stored pressure of 24 bar at 2 C and up to 38.3 bar at 54 C, used to increase the discharge rate of the NOVEC 230 liquid from their storage cylinder(s). The nitrogen cylinders should be suitably designed to be pressure tested at least.5 times the pressure at the maximum temperature of the space in which they are stored, this equates to.5 x 38.3 bar (at 54 C) = 208 bar. The manufacturer pressure tests Nitrogen cylinders at 232 bar for this system 2. All pipework and fittings should be of suitable galvanised steel or stainless steel construction. Threaded joints in fixed gas systems shall be allowed only inside protected spaces and in cylinder storage spaces 3. The arrangements and parts used in the system are to be in accordance with the Kidde ECS ADS Marine Series System document Design, Installation, Operation and Maintenance Manual titled Kidde ECS ADS Marine Series System with 3M Novec 230 Fire Protection Fluid, P/N 06-237257-00, dated July 204. This manual also contains recommended procedures for the control of products of agent decomposition, including HF vapour generated from fluorocarbon extinguishing agents which could impair escape

4 of 6 ATTACHMENT TO CERTIFICATE OF TYPE APPROVAL No. 4. The means of control of the fixed gas fire-extinguishing system shall be readily accessible, simple to operate, and shall be grouped together in as few locations as possible at positions not likely to be cut off by a fire in a protected space. At each location there shall be clear instructions relating to the operation of the system having regard to the safety of personnel 5. Where agent containers are stored within a protected space, the containers should be evenly distributed throughout the space and the arrangement of containers and the electrical circuits and piping essential for the release of any system should be such that in the event of damage to any one power release line or container valve through mechanical damage, fire or explosion in a protected space, i.e. a single fault concept, at least the amount of agent needed to achieve the minimum extinguishing concentration can still be discharged having regard to the requirement for uniform distribution of medium throughout the space; and the containers should be monitored for decrease in pressure due to leakage and discharge. Visual and audible alarms in the protected area and on the navigation bridge or in the space where the fire control equipment is centralised should be provided to indicate this condition 6. Arrangement drawings and calculations are to be submitted for acceptance in each case where it is proposed to install this system. Control panel schematics are also to be submitted. All principle components of the system are to be identified and their location indicated 7. Suitable warning of the possible products of agent decomposition is to be posted at the release station and personnel advised not to enter the space without breathing apparatus and protective clothing until the space has been thoroughly ventilated. Warning should also be posted to say that the integrity of the space is to be maintained after release of the agent and that the products of decomposition and combustion are not to be vented into areas where personnel could be present 8. Production items are to be manufactured in accordance with a quality control system which shall be maintained to ensure that items are of the same standard as the approved prototype GENERAL NOTES. The system is to be designed in accordance with the Annex of IMO MSC/Circ. 848 as amended by MSC./Circ. 267 and MSC./Circ.36. In particular, revised requirements apply where agent containers are stored within a protected space 2. All systems should be designed to allow evacuation of the protected spaces prior to discharge. Means should also be provided for automatically giving audible and visual warning of the release of the fire-extinguishing medium into any space in which personnel normally work or to which they have access. The alarm should operate for the period of time necessary to evacuate the space, but not less than 20 seconds before the medium is released. Unnecessary exposure, even at concentrations below an adverse effect level, should be avoided 3. Even at concentrations below an adverse effect level, exposure to gaseous fire extinguishing agents should not exceed 5 minutes. If a halocarbon agent is to be used above its NOAEL, means should be provided to limit exposure to no longer than the time specified according to a scientifically accepted physiologically based pharmacokinetic (PBPK) model or its equivalent which clearly establishes safe exposure limits both in terms of extinguishing media concentration and human exposure time

5 of 6 ATTACHMENT TO CERTIFICATE OF TYPE APPROVAL No. 4. The mechanical ventilation of the protected space(s) must be stopped before the activation of the fixed gas system and compartment closure arrangements should be designed to provide an agent hold time of at least 5 minutes. The release of an extinguishing agent may produce significant over and under pressurisation in the protected space. Measures to limit the induced pressures to acceptable limits should be provided 5. The system should be supplied by both main and emergency sources of power, with the emergency power supply being provided from outside the protected machinery space. 6. The system pipe work including; pipes, valves and fittings are to be in accordance with the requirements of the approval authority 7. The system storage containers and associated pressure components are to be designed and tested to codes of practice recognised by the approval authority, indicating that they can withstand the pressure expected in service, having regard to their installed location and that they are suitable for the agent identified 8. Recommended procedures for the control of products of agent decomposition are to be provided. In particular, on passenger ships, the decomposition products should not be discharged in the vicinity of muster (assembly) stations 9. Provisions should also be made to ensure that escape routes which may be exposed to leakage from the protected space are not rendered hazardous during or after discharge of the agent. Control Stations and other locations that require manning during a fire situation should have provisions to keep HF and HCl below 5 ppm at that location. The concentrations of other products should be kept below concentrations considered hazardous for the required duration of exposure 0. As longer exposure of the agent to high temperatures would produce greater concentrations of HF and HCl gases, the type and sensitivity of detection, coupled with the rate of discharge, should be selected to minimise the exposure time of the agent to the elevated temperature. The performance of fire-extinguishing arrangements on passenger ships should not present health hazards from decomposed extinguishing agents, for example on passenger ships, the decomposition products should not be discharged in the vicinity of muster (assembly) stations. Other mitigating steps include evacuation and donning masks. Warning signs should be located outside each entry to the protected space(s) 2. Suitable means of checking storage cylinder pressure and weight to be provided 3. Installation onboard: The on board arrangements and installation of this system are not part of this design Appraisal or certificate. All such arrangements are to be to the satisfaction of the Surveyors attending on board. On completion of the installation final acceptance of the system is dependent on satisfactory survey

6 of 6 ATTACHMENT TO CERTIFICATE OF TYPE APPROVAL No. PLACE OF PRODUCTION Kidde Products Limited Kidde-Fenwal Inc. Station Road 400 Main St High Bentham Ashland Lancaster MA 072 LA2 7NA United States of America United Kingdom Fire & Safety, MTES Lloyd's Register EMEA LR427.203.2 Martin Farrier Lead Specialist Statutory Fire & Safety Marine Technology and Engineering Services Lloyd's Register EMEA Supplementary Type Approval Terms and Conditions This certificate and Design Appraisal Document relates to type approval, it certifies that the prototype(s) of the product(s) referred to herein has/have been found to meet the applicable design criteria for the use specified herein, it does not mean or imply approval for any other use, nor approval of any products designed or manufactured otherwise than in strict conformity with the said prototype(s).