Non-Contacting Point Level Detection and Pump Control Sensor. Setting a New World Standard

Similar documents
POINTEK ULS 200 ULTRASONIC LEVEL SWITCH

POINTEK ULS 200 ULTRASONIC LEVEL SWITCH. Instruction Manual August 2002

Ultrasonic switch. Pointek ULS200. Quick Start Manual 03/2013. Milltronics

Level Measurement Continuous level measurement Ultrasonic transmitters

Level instruments. Continuous level measurement - Ultrasonic transmitters. SITRANS Probe LU. Overview. Configuration

Level Measurement Continuous level measurement - Ultrasonic transmitters

Continuous level measurement Ultrasonic transmitters

POINTEK CLS 100 OINTEK CLS 100 CAPACITANCE LIQUIDS/SOLIDS. Instruction Manual March 2001

E C H O T E L C O N T A C T U L T R A S O U N D

Data Sheet 220 LEVEL MONITOR. Supplied by. .com. Call us on +44 (0)

DREXELBROOK. USonic-R Series. Ultrasonic Level Measurement System. User Friendly

POINTEK CLS 200 OINTEK CLS 200 CAPACITANCE LIQUIDS/SOLIDS. Instruction Manual December 2001

POSITIONERS CONTROLS ELECTRO-PNEUMATIC INTELLIGENCE FOR DOUBLE & SINGLE ACTING PNEUMATIC ACTUATORS SERIES 6A. The High Performance Company CELEBRATING

Sitron s CF Line of Flow Switch Monitors

PRODUCT CONFORMITY CERTIFICATE

Low-Cost, Non-Invasive, Microwave-Based Bulk Solids Flow Detector

Instruction Manual April sitrans AS 100

Dissolved Oxygen Measurement liquisys M COM 223 / 253

Measurement & Analytics Measurement made easy. LLT100, LM80, and LM200 Lasers for level: Now everything is possible

Technologies, Solutions, and Applications. Radiation-based Level

MEAS CAL ALARM WASH CONF APT4000 CC ENCLOSURE TYPE 2

Dräger Polytron 8000 Stationary gas detector (EC)

Level gauges Series LS Level indicator, switch and transmitter for liquids

TD Series Temperature Transmitter with Local Display. One-piece sanitary construction 2-wire electronics High accuracy

Rosemount 3100 Series Ultrasonic Level Transmitters

Ultrasonic Point Level Switches

MSM400 Ultrasonic Suspended Solids Monitoring and Control System

Mobrey MSP900SH Level and MSP900FH Flow Ultrasonic Transmitters

Instruction Manual August sitrans CU 02

Process Alarm Module RTA 421

Dräger Polytron 7000 Fixed gas detector

DuroSite LED End-to-End Linear Fixture - UL / CSA for Indoor and Outdoor Industrial Applications

Turbimax CUE21 / CUE22

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

Centro-Matic Automated Lubrication Systems System Controls

Dräger PointGard 2100 Detection of toxic gases and vapours

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Ultrasonic Switches. Features & Benefits

Quick Start Manual July pointek CLS100

Rosemount 3100 Series Ultrasonic Level Transmitters

Sensall Sapphire. Thermo MeasureTech ULTRASONIC POINT LEVEL SYSTEM

Is your process protected?

Dräger Polytron 5100 EC Detection of toxic gases and vapors

POINTEK CLS 300 OINTEK CLS 300 CAPACITANCE LIQUIDS/SOLIDS. Instruction Manual December 2001

CAPITAL CONTROLS SERIES WP70CV3 GAS FEEDERS

Drum Mix facility A schematic diagram of the components in a typical drum mix facility is shown in the figure below.

120W Hazardous Location LED Fixture V DC - Modbus TCP/IP - Network Controlled - Dimmable

CU-02 with Senaco Plus

Instruction Manual December 2001 ENACOCU02

Level Measurement. Point level measurement Capacitance switches. Pointek CLS100. Overview. Configuration

Turbimax CUE21 / CUE22

Level instruments. Point level measurement - Capacitance switches. Pointek CLS100 5/9. Overview. Configuration

MEAS CAL ALARM CONF APT2000 CC ENCLOSURE TYPE 2

Model LTN-3R Outdoor Rated Uninterruptible Power System Single Phase

MEMS Accelerometer ICs. AMR Magnetic Sensor ICs. Gas Flow Modules. Differential Pressure Sensors. Tilt Modules. Current Sensors

Toroidal Conductivity Transmitters Series APT4000 Specifications

MEAS CAL ALARM WASH CONF APT4000 PH ENCLOSURE TYPE 2. Description

Level Measurement. Point level measurement - Capacitance switches. Pointek CLS100. 5/10 Siemens FI Overview.

Software Version 2.01 LEVEL MONITOR MODEL 220

Sapphire ULTRASONIC POINT LEVEL SYSTEM

Continuous and Point Level Measurement. Radiometric Sensors for Liquid and Solid Level Measurement

Oxygen (O2) Single-Point Gas Detection System

Laser Level Measurement Products. Introducing the New LLT100

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Cabinet Cooler Systems

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Installation and Operating Instructions

RTA421. Technical Information. Limit alarm switch Alarm switch and power supply for monitoring current or voltage signals

INFRARED WINDOW SERIES

AS950 PORTABLE SAMPLERS

MEAS CAL ALARM WASH CONF APT4000 TC

The A-series Eletta Flow Monitor with local indication and analog output

Date SECTION MEASUREMENT AND CONTROL INSTRUMENTATION Project Name Page 1

Dräger Polytron 8100 EC Detection of toxic gases and vapors

Rosemount 2100 Series

High Pressure Conductivity Monitor

SILO PROTECTION SYSTEMS

MICROSENSE FLOW SWITCH

25W Hazardous Location Integrated LED Light Fixture Lumens - Low Profile - ATEX IEC CSA UL

Plug-in Base, Long Range Sensor E3B2

Analyze IT Zirconia Oxygen Analyzer for Small Boiler Applications

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

General Purpose Photoelectric Sensor

MEAS CAL ALARM WASH CONF APT4000 PH ENCLOSURE TYPE 2. Description

Dräger Polytron 8310 Stationary gas detector (DSIR)

ECA-DIN. Users Manual. Current and Voltage Alarms. March 2018

Bernstein product overview

Page. 1-2 Sepra-Lite Integral Optic Level Switches. 3-5 Electro Optic Level Systems: Probe and Controller

2 General Application Photoelectric Sensors

FT702LT Turbine control wind sensor gives durability a new meaning FT702LT. series

Ramsey Series Motion Monitoring Systems Accurate Sensing of Speed Conditions on Rotating Shafts and Machinery

T500 Elite - Hotbus Plant Wide Monitoring System for Bucket Elevators & Conveyors

Wallace & Tiernan Liquid Feed System LVN-2000 Liquid V-Notch

LC1350 Level Controller

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

Thermo Scientific Ramsey TM Series Sensing Speed Conditions on Rotating Shafts and Machinery

PRODUCT INFORMATION HISIC450 OVERHEIGHT DETECTORS RELIABLE OVERHEIGHT DETECTION OF VEHICLES. Traffic sensors

Introduction to Flow Switch

Metalarm Metal Detectors. Model TR, BR, PL, PL2 and VC and HH-10 ERIEZ. ...Only from Eriez. Features:

Transcription:

Non-Contacting Point Level Detection and Pump Control Sensor Setting a New World Standard

Key Pointek Features and Benefits Markets Food and Beverage Power Grain/Milling Pulp and Paper Tank Storage Manufacturing Processes Water and Wastewater Aggregate, Cement Application Versatility Level Detection Proximity Detection Overfill Detection Presence/Absence Detection Simple Single/ Dual Pump Control For Sanitary 3A Applications Non-contacting point level detection on liquids, slurries and bulk solids for versatile, low maintenance operation Switching ranges: Liquids/Slurries 0.25m to 5.0m (0.8 ft. to 16.4 ft.). Bulk Solids 0.25m to 3.0m (0.8 ft. to 9.8 ft.) One output can be configured to indicate loss of echo adding to the unit s reliability Simple, two-button set-up Multi-segment graphic on LCD display shows operation status A single Pointek ULS unit provides both high and low level detection. Set-up is as easy as 1-2-3. Parameters such as time delay and deadband can be quickly adjusted as needed through the two programming buttons and a large LCD display, located beneath the readily accessible unit cover. Type 6 NEMA6/IP67 polycarbonate or aluminum enclosure for aggressive environments Easy to install Self-cleaning sensor minimized maintenance/downtime ac or dc power supply Wiring is simple through the cable entry gland Built-in temperature compensation for constant accuracy in variable conditions Sanitary version available, with an industry standard flange option DEADBAND DEADBAND HIGH LEVEL LOW LEVEL

Reliable, Adaptable and Affordable Dual Switch Point Level Detection Left: Standard Model Below: Sanitary Model with Flange Pointek ULS ultrasonic non-contacting point level sensors represent an important breakthrough in reliable, low cost point level detection and simple pump control. As part of the Milltronics family of high performance level measurement instruments, the new Pointek ULS 200 reflects Milltronics continuing commitment to supply the widest range of level detection solutions across a broad spectrum of measurement technologies. Unmatched Performance This low cost, ultrasonic switch is capable of non-contacting detection of two distinct levels on liquids, slurries and solids. It works effectively on bulk solids applications up to 3 metres (9.8 ft.) and on liquids and slurries up to 5 metres (16.4 ft.)... without ever touching the process. Unlike contacting point level devices, there is no material build-up or plugging on the sensor, eliminating many problems associated with invasive mechanical devices such as bubblers and floats. Its rugged integrated design which combines both the sensor and the electronics in one durable package, and absence of moving parts, provides virtually maintenance-free operation. The bottom line? The Pointek ULS 200 delivers superior performance while dramatically reducing your maintenance, downtime and equipment replacement costs. Easy to Program, Easy to Use With the non-contacting ULS 200, there are no rods or extensions to limit flexibility. If there is a change in process application specifications, set-points can be modified on the spot. The unit is programmable using a simple, two-button set-up for high-high, high-low and low-low level detection/ alarms. Each switch point is infinitely variable over the specified range. Installation Couldn t be Simpler Just mount the compact Pointek ULS 200 unit on the top of the vessel with a standard 2 fitting, connect it to the appropriate ac or dc power supply, connect the outputs, set detection levels using the two built-in programming keys and that s it! No need to shut down the process or fill/empty the vessel. The sanitary model is easy to remove and clean... a key requirement for food and beverage processes. Wide Application Versatility To meet the need for configurations that are effective in standard processes as well as hazardous applications, the Pointek ULS 200 enclosure can be ordered in polycarbonate or aluminum with a chemically-resistant Tefzel or Kynar-Flex sensor. This extends the unit s usage to chemical, petrochemical and water and wastewater industries, where more rigorous approval levels are required. When compared to other point level detection products, the Pointek ULS 200, with its unique and powerful features, delivers a cost effective solution at an extremely low cost of ownership.

Designed to Deliver Maximum Application Flexibility Chemical Storage Application in the Food Industry A three step cleaning regimen is used in this application to clean all pipework and vessels used in the manufacture of ice cream products. The non-contacting Pointek ULS 200 is mounted on stainless steel tanks containing various water and chemical combinations and detects two different levels. One output controls an inlet valve while the second controls a pump. The Pointek ULS unit detects both high and low levels within a tolerance set by the deadband, and can be easily re-programmed at any time. Automated Cement Plant Application In this application, raw gypsum is fed from a hopper onto a conveyor belt carrying material to the crusher. The hopper feed frequently becomes blocked, reducing or halting the flow of material. The non-contacting Pointek ULS 200, mounted on a bracket above the conveyor belt, is pre-set to detect a low level condition which results in a signal sent to the central control panel. This, in turn, activates a vibrator on the side of the hopper to clear the blockage. The Pointek ULS point level unit replaced a paddle switch, and resulted in a significant reduction in downtime, maintenance and equipment replacement costs. Porcelain Manufacturing Application The level of porcelain slurry (slip) in the vessel is maintained within two points (on/off, high/low) by the Pointek ULS 200, which controls the opening and closing of a valve. The mixture is agitated in the vessel and then dosed out in batches to the manufacturing process.

Design and Construction Highlights The use of ultrasonic technology for point level detection means that there is no need to specify the length of the wetted part on installation. If your application specification changes, simply adjust the Pointek ULS settings. No modification or replacement units are required. (Standardization on Pointek ULS for all your applications could mean significant savings.) The non-contacting Pointek ULS 200 is virtually immune to many of the problems inherent to most contacting level detection devices e.g. material build-up and is unaffected where there is a presence of suspended solids in a liquid application. One unit can provide both high and low level detection which results in a reduced initial investment as well as a low ongoing cost of ownership. The two adjustable switch outputs are programmable for high-high, high-low and low-low level alarms and/or simple pump control. With the Pointek ULS 200, changes in application requirements can be accommodated on the fly. Settings are modified by the user with the push of a button. The Sonic Intelligence Advantage The Pointek ULS ultrasonic sensor continuously emits sonic pulses that are reflected from the target surface. By measuring the time delay between transmitted and reflected pulses, levels are constantly monitored. To optimize accuracy, the Pointek ULS output is automatically temperature compensated before conversion to distance. Advanced echo processing techniques of Sonic Intelligence software ensure consistently reliable data from the Pointek ULS. The unit not only differentiates between real echoes and echoes generated by acoustical or electrical noise, but can also capture weak true echoes in hostile environments where extreme hot, cold or steamy conditions can make other level detection systems inoperable. A three digit LCD (located under the lid) displays the distance between the sensor face and the material. Set-up is easy, using two programming keys.

S p e c i f i c a t i o n s Operations Detection Range Liquids: 0.25m (0.8 ft.) to 5m (16.4 ft.) Solids: 0.25m (0.8 ft.) to 3m (9.8 ft.) Modes of Operation High, low, high-high, high-low, low-low level indication Pump Control: single pump control with one alarm or failsafe or simple dual pump control only Repeatability 0.25% of full range Resolution 3mm (0.1 ) Echo Processing Patented Sonic Intelligence software Memory Non-volatile EEPROM Process Pressure Vent to atmosphere Sensor Beam Angle 10 at -3dB boundary Ambient Temperature -40 to 60 C (-40 to 140 F). For metal mounting: -20 to 60 C (-5 to 140 F) Process Temperature -40 to 60 C (-40 to 140 F). For metal mounting: -20 to 60 C (-5 to 140 F) Process Temp. Compensation Built in to compensate for fluctuations over the operating range Outputs ac Version dc Version Deadband Display Information Programming 2 form C (SPDT) contacts, rated 5A at 250 Vac non-inductive 2 non-polarized transistor switches rated 48 Vdc, 100 ma maximum or 2 form C (SPDT) contacts, rated 5A at 48 Vdc Independently adjustable deadbands LCD displays three 9mm (0.35 ) digits for programming distance between sensor face and material. Multi-segment graphic for operation status. 2 keys Installation Power Supply 18 to 30 Vdc, 3W maximum or 100 to 230 Vac, 12VA (5W) maximum Wiring Termination Terminal block: 2.5mm 2 (14 gauge) solid / 1.5mm 2 (16 gauge) stranded maximum Cable Entry Polycarbonate enclosure 2 connections: 1/2 NPT or PG 13.5 Aluminum enclosure 2 connections: 1/2 NPT or PG 13.5 Sensor Mounting: Threaded 2 NPT, 2 BSP or PF2. Optional flange adapter to 3 ANSI, DIN 65PN10 and JIS 10K3B Sanitary 4 3A compliant tri-clamp Integrated Enclosure Electronics Material Polycarbonate or optional epoxy coated aluminum with gasket Ingress Protection Type 6 / NEMA 6 / IP67 Sensor Material Tefzel or Kynar-Flex Environmental Location Indoor / outdoor Altitude 2000m (6562 ft.) maximum Installation Category II Pollution Degree 4 Shipping Weight Approvals Polycarbonate enclosure: 1.6kg (3.52 lbs.) Aluminum enclosure: 2.3kg (5.06 lbs.) CE. 3A. CSA NRTL/C. Pending: FM, general purpose For hazardous applications: CSA. Pending: FM, CENELEC. Specifications are subject to change without notice. Y2K Compliant - Year 2000 Compliant Representative 35751015 NA 35751016 A4 29-2 1954 Technology Dr., P.O. Box 4225, Peterborough, Ont., Canada K9J 7B1 Tel.: +1 705-745-2431 Fax: +1 705-741-0466 182 Normanby Rd., Box 339, South Melbourne, 3205, Australia Tel.: +011-613-9695-2400 Fax: +011-613-9695-2450 August van de Wielelei 97, 2100 Deurne, Antwerp, Belgium Tel.: +32(0)3326 45 54 Fax: +32(0)3326 05 25 Century House, Bridgwater Road, Worcester, England WR4 9ZQ Tel.: +44 1905-450500 Fax: +44 1905-450501 Parc de la Sainte Victoire, Bât. 5, 13590 Meyreuil, France Tel.: +33 4 42 65 69 00 Fax: +33 4 42 58 63 95 Werftstrasse 47, D-40549 Düsseldorf, Germany Tel.: +49 211 562 5025 Fax: +49 211 562 6030 1 Hoi Wan Street, Suite 602, Quarry Bay, Hong Kong Tel.: +011 852-2856-3166 Fax: +011 852-2856-2962 Amores No. 1155, Col. del Valle, 03100 Mexico D.F., Mexico Tel.: +52 5 575-27-28 Fax: +52 5 575-26-86 Nikkelstraat 10, NL-4823 AB Breda, The Netherlands Tel.: +31(0)76 542 7 542 Fax: +31(0)76 542 8 542 709 Stadium Drive, Arlington, Texas U.S.A. 76011 Tel.: +1 817-277-3543 Fax: +1 817-277-3894 A joint venture in Singapore, a sales office in Brazil and distributors in 56 countries. Internet: http://www.milltronics.com Printed in Canada