Ronan Model X90 Series Point Level Monitor

Similar documents
Ronan Model X96S Series Weighing System

Ronan Model X96S Series Density System

M E A S U R E M E N T S D I V I S I O N

Continuous and Point Level Measurement. Radiometric Sensors for Liquid and Solid Level Measurement

Technologies, Solutions, and Applications. Continuous Level Coke Drum Measurement System

Technologies, Solutions, and Applications. Radiation-based Level

SPECIFICATION CHEMGARD INFRARED GAS MONITOR SERIES

SIL 2. Ultima X Series Gas Monitors CERTIFIED

DensityPRO+ Gamma Density System with Remote Transmitter Installation Guide P/N Part of Thermo Fisher Scientific.

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

AIR or STACK MONITOR NOBLE GAS, GROSS BETA-GAMMA PARTICULATE, & IODINE. Optional Alpha, Tritium, Carbon-14

Electronic Flow Switches

MOVING FILTER AIR MONITOR ALPHA, BETA/GAMMA PARTICULATES

MOVING FILTER AIR MONITOR ALPHA, BETA/GAMMA

Technical Reference Manual

Dräger Polytron 7000 Fixed gas detector

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

Dräger Polytron 5100 EC Detection of toxic gases and vapors

NEX-BETA-ABG FACILITY Drinking Water Safety Monitor

RF Admittance Technology FACTS

SEC 2000 Millenium Infrared Gas Detector

MULTI-POINT DENSITY ARRAY FIXED-POINT INTERFACE PROFILING MEASUREMENT

Improve Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor...

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

LOW MINIMUM DETECTABLE ACTIVITY (MDA)

300/400 UNITS - MODULAR CONFIGURATION

Portable Survey Instruments NISP-RP-01

INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY

Gate Operator. Modfications

APPLIED. OMA-300 Hydrogen Sulfide Analyzer H 2. Ex p. Ex d. The world s safest continuous H 2. S analyzer. The OMA continuously measures H 2

All icon products are. Easy to use: with an intuitive glass touch-screen, wipe-clean graphic user interface with multi-language options.

NUCLEAR INDUSTRY STANDARD PROCESS Radiological Protection. Level 3 Information Use

SenSmart Universal Gas Detector Series

Model Q45P/R. ph/orp Monitor...

Flame Monitor for Multiple Burner Furnaces D-LE 603 D-UG 660

Centro-Matic Automated Lubrication Systems System Controls

Dräger Polytron 5700 IR Detection of flammable gases and vapours

INDUSTRIAL GRADE WATER SOFTENERS LWT INDUSTRIAL SERIES

Model D12-IR. Digital Gas Transmitter...

Model Q45P/R. ph/orp Monitor...

RTD TEMPERATURE SENSING SYSTEM

STRIKE GUARD DELIVERS:

Pioneer-R16 Gas Monitor Operator s Manual

Liquid Helium Level Instruments

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

AnaLASER II Detector. Protection Systems. A UTC Fire & Security Company. High-Sensitivity Smoke Detector (HSSD ) FEATURES DESCRIPTION

Ultrasonic Point Level Switches

Excellence through Versatility

3500/61E & 3500/67E Temperature Monitor

Beacon 800 Gas Monitor Operator s Manual

PH / ORP Analyzers MODEL OPM223/253. Wedgewood Analytical Inc. Liquid Analytical Measurement & Control Specialists DESCRIPTION FEATURES APPLICATIONS

Industrial Grade Gas Detection Detecting The Difference

Sitron s CF Line of Flow Switch Monitors

Temperature Controllers

Dissolved Oxygen Measurement liquisys M COM 223 / 253

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]

Dräger Polytron 8000 Stationary gas detector (EC)

Model 1062 Environment Monitor

APPLICATION DATA SHEET

ADDENDUM. xwatch Explosion-Proof Camera with X-Series Flame Detectors DESCRIPTION GENERAL APPLICATION INFORMATION

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

VIBRATION TRANSMITTER MODEL 140T INSTALLATION The mounting orientation can be in any position. This position should be in an area for the best vibrati

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Dräger REGARD -1 Control System

DensityPRO+ Gamma Density System with Remote Transmitter User Guide P/N Part of Thermo Fisher Scientific. Revision C

Ultrasonic Switches. Features & Benefits

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

Data Sheet 220 LEVEL MONITOR. Supplied by. .com. Call us on +44 (0)

vibration switch

SYSTEM DESIGN REQUIREMENTS

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

incontrol Systems Inc. Flame and Gas Detection

Installation and Operating Instructions

Page. 1-2 Sepra-Lite Integral Optic Level Switches. 3-5 Electro Optic Level Systems: Probe and Controller

Troubleshooting Thermo Scientific LevelPRO Gauges

Using the DewTrak II Dew Point/ Humidity Transmitter

SENSITIVE ENOUGH TO DETECT RUNOFF CHANGES IN GROUNDWATER TRITIUM PLUMES

AS950 REFRIGERATED SAMPLERS

TrueAlarm Analog Sensing

SLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001

Model 4001 Series Single Channel Controller

Continuous Gamma Level System Installation Guide P/N

MODEL 1925-PR TRITIUM HEAVY WATER LEAK DETECTOR

ULTRA-SAFE Explosion-proof Duct Heaters

WARRANT Y AND LIMITS OF LIABILIT Y Vulcain Inc. warrants to the original purchaser that its product, and the component parts thereof, will be free fro

A New Standard of Excellence

CLARITY II TURBIDIMETER

ph COOLING TOWER CONTROLLER

DF-340E PROCESS ANALYZERS APPLICATIONS FEATURES

Model LTN-3R Outdoor Rated Uninterruptible Power System Single Phase

Dräger Polytron Pulsar 2 Open Path Gas Detector

Operating Instructions

HEALTH AND SAFETY MANUAL

Process Protection. MFA 4P Motion Failure Alarm

INSTALLATION, OPERATION INSTRUCTIONS FOR FLOW SWITCHES 62-9FS & FS

HIGHLY SENSITIVE FOR NUCLEAR POWER PLANTS Real-Time Continuous Water Monitor

Cabinet Cooler Systems

TRACENET TM TN SERIES

Dräger Polytron 8100 EC Detection of toxic gases and vapors

C1D1 Explosion Proof Horn - Industrial Siren - Programmable Timer - NEMA 4X - Weatherproof

Transcription:

Ronan Model X90 Series Point Level Monitor For more than 27 years Ronan has provided the process control industry with unsurpassed products in the harshest environments. With a philosophy of designing new products to be backward compatible, our customers have the confidence of an installed base of thousands of systems. A worldwide network of dealers, 24-hr factory certified Field Service Engineers and an experienced staff of Applications Engineers are ready to assist with your measurement needs. Product Information Applications Solids and Liquids Measurement Measurement Not Affected by: Dust or Moisture High Temperatures Corrosive, Abrasive or Toxic Materials Features and Benefits Lowest Activity Sources on the Market Remote or Integral Electronics Remote Mount in 1 to 7 Unit Chassis. Programmable Through Hand-Held Communicator Low Maintenance / No Component Wear Integral Mount Electronics The X90 Point Level Monitor detects the presence or absence of material at a given point in a tank, hopper, chute or process pipe. All components are mounted externally to the process vessel making the system ideal for monitoring the most dangerous materials such as caustic, toxic, corrosive, explosive, and carcinogenic irrespective of their temperature. The modular design is ideal to upgrade older systems while keeping the existing sources.

Remote Mount Electronics Measurement Principle Each point level system consists of a gamma source, detector and either integral or remote mount electronics. The detector receives energy at a level dependant upon the presence or absence of the process material inside the pipe or vessel. Applications requiring both high, and low-level alarms, or the monitoring of several points may, in many cases, utilize the same source. The electronics unit converts the pulse output of the detector and provides a DPDT (double-pole, double-throw) contact output, which represents the change in status between the presence and absence of material. This electronics unit may be mounted integrally to the detector or at a remote location.

Source Holders Ronan pioneered the development of ultra-low level sources to greatly improve safety, and eliminate the requirement for surveys, wipe tests, inspections and much of the documentation. They are so safe the NRC permits their removal and installation without a licensed person being present, translating into significant cost savings for the user.

The RLL-1 ultra low source utilizes very small quantities of radioactive materials. RLL is a Ronan Engineering term that stands for "Radiation Low Level." RLL technology utilizes up to a total of 0.9 mci (0.033 GBq) of cesium source. In comparison, some conventional weight gamma gauges use source sizes with a hundred times more activity to make the same measurement. Because of these very low-levels of activity, and their simplicity of design, Ronan systems are the safest gamma gauges on the market. The NRC recognized this in 1999 when Ronan Engineering attained certification for the first RLL source design. RLL-1 Low level LS Source Holders SA-1 Source Holder Source Holders The LS series of source holders are approved for General License installations on level applications when used with an interlock device. The source is available in both single (LS-S) and dual (LS-D) port configurations for installations where vessels are close to each other and one source can be used on both. i.e. Flyash Hoppers

Specifications X90 Programmable Integral Electronics Performance System Accuracy Switching Time Outputs: Relay +/- 0.25 (6.35 mm) Nominally 1 second SPDT 5A at 30 VDC Res.; 2A at 30 VDC Ind..; 5A at 250VAC Res.; 3A at 150 VAC Ind. Open Collector 100 ma at 30VDC Diagnostics Calibration On-Board Modular Self-Test Watchdog Timer and Status LEDs Available Through Hand Held Communicator (RS485) or Local Push Button Environmental Operating temperature -40 to +60 C (-40 to 140 ) Electrical Power supply 110/220 VAC @1A or 24 VDC @ 0.3 A. Power Consumption 7 Watts Per Alarm Point Mechanical Construction Housing - 4 inch Diameter Schedule 40 Carbon Steel Explosion Proof - Stainless Steel Optional Paint Weight Protective Coating; Epoxy Based Approx. 37.4 lbs (17 kg) Approvals Warranty Class I, Div 1 Groups A,B,C,D; Class II, Div I, Groups E,F,G Nema 4, Nema 4X Three Year Limited Warranty

X90 Programmable Remote Electronics Performance System Accuracy Switching Time Outputs: Relay +/- 0.25 (6.35 mm) Nominally 1 second SPDT 5A at 30 VDC Res.; 2A at 30 VDC Ind..; 5A at 250VAC Res.; 3A at 150 VAC Ind. Open Collector 100 ma at 30VDC Diagnostics Calibration On-Board Modular Self-Test Watchdog Timer and Status LEDs Available Through Hand Held Communicator (RS485) or Local Push Button Environmental Operating temperature -40 to +60 C (-40 to 140 ) Electrical Power supply 110/220 VAC @1A or 24 VDC @ 0.3 A. Power Consumption 7 Watts Per Alarm Point Mechanical Chassis Single Weight Single Surface Mount Chassis. General Purpose Enclosure: One Module Approx. 10 lbs (5 kg) Surface or Rack Mount Chassis. General Purpose.. Holds up to Seven Modules Warranty Three Year Limited Warranty

Ronan Scintillation Detector Ronan pioneered the use of solid crystal scintillation detectors more than 20 years ago, and now has an installed base in the thousands across a wide variety of applications worldwide. Ronan employs two types of crystals: Scintillating Plastic Crystals for standard low-level applications, and Sodium Iodide scintillating crystals for ultra lowlevel fields. For point level applications, scintillation detectors are used for low level fields. Features High Detector Efficiency Spring Tension of PM Tube. Maintains Integrity of the Signal Path Under Vibration and When Detector is Mounted Inverted Lowest Gamma Fields in Industry Ronan Quality Manufacturing-Backed by a Three Year Limited Warranty

Scintillation Detector Specifications Performance System Accuracy Environmental Operating temperature Electrical Power supply Mechanical Construction Scintillation Crystal Weight Approvals Warranty +/- 1 % span -10 to +60 C (Low Temperature and High Temperature Options Available) 24 VDC @.035 A Electronics - Stainless Steel Housing - Schedule 40 Carbon Steel, Epoxy Painted - 304 Stainless Steel Optional - PVC Optional Plastic or Sodium Iodide 15 lb/ foot Complies with Cenelec/Atex CSA Class 1, Div 1 Groups A,B,C,D Nema 4, Nema 4X Three Year Limited Warranty

Ronan High Sensitive Geiger- Müller Tube Detector Ronan Geiger Müller Tube Detectors consists of a gas-filled tube containing electrodes, between which there is an electrical voltage, but no current, flowing. When ionizing radiation passes through the tube, a short, intense pulse of current passes from the negative electrode to the positive electrode and is measured or counted. The number of pulses per second measures the intensity of the radiation field. These pulses are directly proportional to the process mass being monitored and the electronics are then calibrated for the desired alarm status. For point level applications, Geiger Müller Tube detectors are used for high fields.

High Sensitive Geiger- Müller Tube Detector Specifications Performance System Accuracy Environmental Operating temperature Electrical Power supply Mechanical Construction Weight +/- 1 % span -10 to +60 C (Low Temperature and High Temperature Options Available) Powered from Electronics Stainless Steel Approx. 3 lbs Warranty One Year Limited Warranty

Programmable Integral Switch

Programmable Multi-Point Surface Mount

Programmable Single Point Surface Mount

Programmable Multi-Point Rack Mount Switch