NFPA 70E Elevates Safety. with Heightened Risk Awareness

Similar documents
IEEE Std IEEE Recommended Practice for Electrical Installations on Shipboard Safety Considerations

Arc Flash Protection Training - NFPA 70e Electrical Safety

Guide to Compliance with the Electrical Workplace Safety Standards in the United States

Electrical Safety for Facility Managers and Building Owners

NFPA 70E Edition Update

Understanding 2015 Changes to NFPA 70E Safety-related work practices and maintenance requirements mandate more robust electrical safety programs for

Electrical Safety Compliance: NFPA 70E

NFPA 70E Electrical Safety & Arc Flash Training

Electrical Hazards and NFPA-70E: Protecting Your Employees

2012 Edition. Tech Topics: Standards & Codes. Note 4, Issue 1. Points of Interest: Introduction. Background. Changes to Definitions in Article 100

May is National Electrical Safety Month, an AND THE ELECTRICAL INSPECTOR. by Mark Hilbert and Laura L. Hildreth

NFPA 70E Standard for Electrical Safety in the Workplace. EEI Safety and Health Meeting May 2011

6/23/ National Electrical Contractors Association and Intec, Inc.

T22 - Arc Flash Hazards and Arc Resistant Equipment- Understanding the Standards

NECA S System Approach to Electrical Safety for NFPA 70E

NECA. Standard for Electrical Safety in the Workplace

UNDERSTANDING 2015 CHANGES TO NFPA 70E

NFPA 70E. Electrical Safety in the Workplace. KTR Associates. Joseph Deane, PE. Engineering Solutions

NECA S System Approach to Electrical Safety for NFPA 70E

UNDERSTANDING 2015 CHANGES TO NFPA 70E

SUMMARY: Policy Title: Electrical Safety Work Practice Program. Policy Number: UNIV-EHS 430 Policy Approved: January 2014

HESNI ANNUAL CONFERENCE May 3, 2012 Aramark Conference Center, Downers Grove

Arc Flash Analysis. Arc flash hazard analysis is required to determine the risk to personnel, warn them of the

PREVIEW COPY. Table of Contents. Annexes and Supplemental Materials Lesson One Article 90: Introduction and Purpose... 3

IMPROVE SAFETY WITH ARC FLASH LABELING COMPLY WITH THE 2015 NFPA 70E REGULATIONS

SALISBURY ASSESSMENT SOLUTIONS

Applying the 2012 NFPA 70E. Arc Flash Standard

How many time has your company been asked by an owner or customer to work on equipment energized?

Your Global Automation Partner. Minimizing Arc Flash Exposure in Industrial Applications. White Paper - W1000

Changes to NFPA 70E. - The Role of PdM &Safe PdM Work Practices. Tim Rohrer Exiscan LLC

PREPARING YOUR ORGANIZATION FOR NFPA 70E 2015

Professional Seminar. The Electrically Safe Workplace. Understanding the NFPA 70E Electrical Safety Standard, 2012 Edition ...

Arc Flash Codes & Compliance: What You Need to Know to Deliver Both Protection and Performance

Arc Flash Mitigation Solutions: A Proactive Approach To Arc Flash Risk

NFPA 70E Electrical Safety in the Workplace

White Paper. NFPA 70E 2018 Edition Changes and Implications for. Personnel Performing Condition Based Maintenance. Abstract: iriss.

Centennial Energized Electrical Work Permit Instructions

2014 National Electrical Code & NFPA 70E/Arc Flash

DEMYSTIFYING FR CLAIMS: AN ERGODYNE WHITE PAPER

Implementing an Energized Electrical Work Program. SESHA Hill Country Chapter. Brett Jay Davis, PE Zephyr Environmental Corporation

NFPA 70E Update: Key Changes You Need to Know to Assure Compliance

Electrical Safety Program

Janine Bain Rhonda Lewis Harland Hirst Sandra Olive David Johnson Edward Maurer Kathy Felsten Joe Halle

Welcome DISCLAIMER. Testing Electric Fire Pumps You Need to Understand the Arc Flash Hazard 5/1/ NFPA Conference & Expo

NATIONAL ELECTRICAL CODE (NEC) & NFPA 70E ARC FLASH ELECTRICAL SAFETY

NFPA 70E Arc Flash Considerations for MV Equipment. By: Dominik Pieniazek, P.E. HV Engineering, LLC

PROTECTING AGAINST ARC FLASH HAZARDS

Electrical Safety Program.

Safety Meeting Topic #37 NFPA 70E What is it?

Promoting Electrical Safety through NFPA 70E Standards Adherence

Brian McCauley December 2017

The Basics Arc Flash Protection

White Paper. Reducing Arc Flash Risks with Electrical Maintenance. Safety Devices. Abstract: iriss.com


SEL Arc-Flash Solutions

SEL Arc-Flash Solutions

The Electrical Safety Guide

A Powerful Case for Infrared Windows

VeriSafe Absence of Voltage Tester The safe way to verify the absence of voltage

TABLE OF CONTENTS 1 AVO TRAINING INSTITUTE MISSION STATEMENT 2 AVO AT A GLANCE 4 TRAINING LOCATIONS 6 ELECTRICAL CONSULTING SERVICES

Energized Electrical Work Review. Thomas Jefferson National Accelerator Facility

Rutgers Environmental Health and Safety (REHS)

DANGERS AND HAZARDS OF ENTERING LIVE SUBSTATIONS AND ENCLOSURES Barry Gass Actom Protection and Control

[PDF] ELECTRICAL SAFETY TRAINING EBOOK

White Paper. OSHA and NFPA 70 Understanding NFPA 70 and its. Implications in Electrical Inspections Abstract: iriss.com

Thomasville fire rescue

NFPA 70E STANDARD FOR ELECTRICAL SAFETY IN THE WORKPLACE 2012 Edition

General Safety Training

Your Turnkey Solution for Mitigating the Hazards of Arc Flash Incidents in the Workplace

General Safety Training

The safe way to verify the absence of voltage.

Regional Training. Seminar. » EasyPower Hands-On» Protective Device Coordination» Arc Flash Hazard Analysis. March 12-16, 2018 Austin, TX

Licensed Electrician Dies When Electrocuted by 480Volts Incident Number: 03KY115

Predictive Maintenance Training

Protection from Electric Shock and Arc Flash. Meeting OSHA Regulations and NFPA 70E Standards.

OSHA-Required Trainings Offered by Ultimate Risk Services

UNDERSTANDING ELECTRICAL SAFETY RISKS

COMPLIANCE without compromise SAFETY without sacrifice YOUR RESULTS MATTER

REO & HPIR (HUD Property Inspection Report) Electrical Inspections Safety, Codes & Standards

EMERGENCY PREPAREDNESS & RESPONSE PROCEDURE

Compliance without compromise Safety without sacrifice

Arc Flash Analysis: IEEE Method versus the NFPA 70E Tables July 2017 / 1910DB1702

HOW-TO CONDUCT A WEEKLY SAFETY MEETING

DON T GET BURNED BY THE CONFUSION:

NFPA Overview. International Titanium 2014 Conference Chicago Kevin L. Kreitman

Health and Safety Plans Health and Safety Policy Statement Fire Prevention Plan Objective

Safety requirements for voltage testing instruments

Document Number: ELECTRICAL SAFETY ZSD-HMSAFESA Issue Date: July 4, 2017 Revision #: 3 Next Review Date: July 4, 2022

State of North Carolina Department of Environment and Natural Resources Division of Waste Management. Safety and Risk Management Program

Become familiar with the subject areas in the table of contents for OSHA standards through and

WHY ELECTRICAL PREVENTIVE MAINTENANCE IS ESSENTIAL TO A SAFE AND PRODUCTIVE WORKPLACE

ELECTRICAL SAFETY GUIDELINE

NECA & Salisbury Assessment Solutions Partnership

To: All SAAS Accredited Certification Bodies Subject: Clarification to Emergency and Health & Safety Requirements in the SA8000 Standard

F&S Control of Hazardous Energy Program

ENERGY CONTROL LOCKOUT/TAGOUT PROGRAM PLAN

Occupational Safety Next Review Date: 12/20/17. Scope: University Wide Original Creation Date: 2009

Answer: B Objective: NFPA 472, (c), 4.2.3, 5.2.3(1); Level: Awareness, Operations Subject: Introduction; Chapter 1; Page 5

Compliance Solutions: NFPA 70E 2018 Edition from Schneider Electric Services

Electrical Safety Myths and Facts

Transcription:

NFPA 70E 2015 Elevates Safety with Heightened Risk Awareness Next Page

NFPA 70E 2015 Elevates Safety with Heightened Risk Awareness: Significant Changes Since 2012 Compel Updated Electrical Safety Training By Sheila Kennedy NFPA 70E, Standard for Electrical Safety in the Workplace, is an indispensable, ongoing work in progress. Approximately every three years, it is updated to incorporate the latest electrical safety research, risks, work practices, electrical designs, and personal protective equipment (PPE) to reduce the number of deaths and injuries caused by shock, electrocution, arc flash, arc blasts, and fires. Much is learned every year. When the National Fire Protection Association (NFPA) initiated the voluntary standard at the Occupational Safety and Health Administration s (OSHA s) request in 1979, its first edition only addressed electrical shock. It wasn t until the 1995 edition that arc flash hazards were recognized, and numerous workplace safety requirements have since been added. Each new edition succeeds in further improving electrical safety in the workplace and makes the prior version obsolete. As the safety standard evolves, so must the companies and electrical workers that use it. The 10th and latest release, NFPA 70E 2015, contains some significant differences from its 2012 predecessor. It is essential to clearly understand these changes and why they matter in order to remain compliant with OSHA, avoid compromising lives and safety, reduce liability, and prevent unexpected and costly downtime. Safety consulting and engineering services can be called upon to help expedite and refine safety education and compliance initiatives. 2

Summary of NFPA 70E 2015 Changes The new edition strives to ensure a safer workplace and clarify the responsibilities of employees and employers by making the following major changes, in addition to extensive minor adjustments. Users are made more aware of the devastating risk of failure and loss caused by shock, arc flash, and arc blast hazards by replacing the phrase hazard analysis with risk assessment throughout the standard. The risk assessment process is defined as identifying the hazards, estimating the potential severity of injury or damage to health, estimating the likelihood of the injury occurrence or damage to health, and determining if protective measures are required. Maintenance status is now an integral part of the risk assessment. The electrical safety program must now include maintenance on electrical equipment as a primary element. The responsibility for proper installation and maintenance is assigned to the equipment owner or the owner s designated representative. Clarification was made that the risk assessment is required, not the incident energy analysis, which is one component of the risk assessment. The elimination of hazard/risk categories will force a culture change because HRC has become institutionalized terminology. The short-circuit current and clearing time of the over-current protective device must be known for an incident energy analysis. Hazard/risk category (HRC) tables have been replaced with a new task-based table that clarifies selection methods for arc flash PPE, and all references to HRC have been replaced with the term arc flash PPE category. This will force a culture change because HRC has become institutionalized terminology in the industry. 3

NFPA 70E 2015 training objectives Identify the common factors of electrical accidents Understand the arrangement of the NFPA 70E material Explain the hazards of electrical work and their effects Describe the main elements in an electrically safe work program Identify the requirements for establishing an electrically safe work condition (lockout/tagout) Identify the requirements for a shock risk assessment Identify the requirements for an arc flash risk assessment Establish approach boundaries for shock protection for qualified and unqualified employees Select PPE for shock protection Select safe work practices if an arc flash hazard is present Understand the use of the arc flash boundary Select PPE for arc flash protection To use the PPE category tables, the short-circuit current and clearing time of the over-current protective device must be known. HRC 0, the standard PPE worn every day for normal construction activities, has been eliminated; now, the qualified person must make a risk determination based upon normal operation of equipment that meets all of the following criteria: The equipment is properly installed The equipment is properly maintained All equipment doors are closed and secured All equipment covers are in place and secured There is no evidence of impending failure Companies can develop their own PPE numbering system. Warning label content was expanded to include: Nominal system voltage Arc flash protection boundary At least one of the following: Incident energy at a corresponding distance or PPE category selected using 70E tables, but not both Minimum arc rating of clothing Site-specific level of PPE The electrical equipment owner is now responsible for the documentation, installation, and maintenance of field-installed labels. The requirements for construction and maintenance work were separated from outdoor work to enhance usability. The table update for restricted approach boundary dimensions added clarity, and the prohibited approach boundary was deleted. A new requirement covers risk assessment associated with battery work. Explain contractor and employer compliance responsibilities 4

Why Do These Changes Matter? NFPA 70E provides instructions on how to comply with OSHA s electrical safety regulations. According to OSHA, there are approximately 350 electrical-related fatalities each year. OSHA is able to cite companies for non-compliance with the consensus standard when an electrical accident causes a serious injury or death, even though NFPA 70E is considered voluntary rather than a Federal regulation. Certain states with more restrictive occupational health and safety laws require NFPA 70E compliance. NFPA makes it the responsibility of the employer to educate employees on safety standards, including qualified and unqualified electrical workers. In fact, a plant manager can be held criminally responsible for a worker s injury if the worker did not have proper safety training. Personnel in any industry who work on or around AC or DC voltages of 50 volts or more, or are responsible for safety in the workplace, should receive NFPA 70E 2015 training. In particular, the new standard s risk assessment process alters the paradigm by broadening the scope of employees requiring safety education. Employers must assess generally recognized arc flash and shock hazards in the workplace and make provisions for protection from those hazards, and all employees must be made aware of the potential hazards. A plant manager can be held criminally responsible for a worker s injury if the worker did not have proper safety training. The 2015 edition requires an arc flash risk assessment to determine whether an arc flash hazard exists. If it exists, the employer must determine the risk to employees and the required safe work practices, arc flash boundary, and PPE, explains Dennis Neitzel, Director Emeritus at AVO Training Institute and a principal committee member and special expert for the NFPA 70E standard. Similarly, shock risk assessments are required to determine the voltage, shock boundaries, and PPE. These new skills must be quickly trained and implemented. 5

All employees who are exposed to electrical hazards where the risk has not been reduced to a safe level (with no exposed energized conductors or parts of equipment and the equipment is essentially stagnant) require risk and avoidance training, according to the new standard. The reality is, covers are removed, equipment doors are opened, and most equipment is operated manually or automatically on a regular basis, says Neitzel. Even the process of establishing an electrically safe work condition puts the employee at risk. Ultimately, all employees must be trained, not just electricians. Anyone in close proximity is potentially at risk of serious injury or death from arc flash burns, whether it s an operator, mechanic, janitor, office worker, or someone plugging into an electrical outlet, he adds. Everyone must be trained to identify, understand, and avoid the electrical hazards and risk of injury associated with the tasks that they are required to perform. Neitzel recommends that a job/task analysis and task hazard analysis with shock and arc flash risk assessments be conducted for each employee. The exposure or potential exposure to electrical hazards should be recorded in the employee s job description and their training requirements determined accordingly. Finally, employers must certify that the hazard assessments were performed, and authorize energized electrical work permits as needed. Companies must be prepared to share these records if requested during an OSHA inspection. The new standard s risk assessment process alters the paradigm by broadening the scope of employees requiring safety education. Compliance May Necessitate Outside Assistance OSHA requires employers to document and implement an electrical safety program that addresses exposure to all existing hazards, and those likely to exist, in the workplace. The program must be published and available to all employees who might be exposed to the hazards. OSHA also has specific equipment labeling requirements. Developing, documenting, training, and implementing safety programs and procedures can be expedited with the aid of third-party experts in electrical safety and associated regulations. 6

Arc flash risk assessments and shock risk assessments are urgent tasks because they must be conducted before any person is exposed to electrical hazards, according to NFPA 70E 2015. Navigating all of the requirements, conditions, and exceptions that result from these assessments requires a great familiarity with the new standard. Hazard assessments, incident energy analysis, and follow-up activity can be supported expeditiously and in accordance with NFPA and IEEE standards by third-party electrical safety experts. Unfortunately, the language used by OSHA can make its electrical standards difficult to interpret and apply. Training of each new edition of the OSHA, NFPA, and NEC electrical safety standards should be delivered by someone who has a thorough understanding of the latest requirements and how they apply to individual facilities, and who can relay the complicated material in an easily understood manner, regardless of the students experience level. Multiple delivery options are available for electrical safety training. Custom courses can be designed to match a company s industry and environment, including its voltage, energy level and circuit conditions. Online and on-site training options avoid incurring personnel travel time and expenses. Fully equipped, regional training centers provide skills-based training combined with hands-on labs. Everyone must be trained to identify, understand, and avoid the electrical hazards and risk of injury associated with the tasks that they are required to perform. Arc flash and power system analysis studies performed by registered engineering firms identify and mitigate the hazards created by electrical equipment. Folding these engineering studies into the latest industry standards enables continuous improvement of workplace safety, OSHA compliance, equipment reliability, and uptime. Summary For more than 35 years, NFPA 70E has delivered on its mission to continuously improve safe workplace practices, but the standard remains a work in progress. Although each new edition requires new training and implementation efforts, this voluntary how-to guide for OSHA compliance plays an invaluable role in helping to mitigate electrical safety hazards in the workplace, protect human lives and safety, and keep businesses up and running. 7

Download the Avo 2015 Course Catalog www.avotraining.com/resources/downloads (click here) KEEPING PEOPLE SAFE FROM ELECTRICAL HAZARDS FOR OVER 50 YEARS About Avo Training Institute AVO Training Institute a subsidiary of Megger celebrates its 50th year of keeping people safe from electrical hazards. From equipment application and maintenance procedures to safe work practices, arc flash studies and engineering services, AVO is the complete one-stop learning center. In addition to classroom lectures, our difference is our hands-on approach to training. Students are required to perform tasks in equipment labs supervised by the most talented electrical instructors in the industry. Courses are offered at our locations nationwide or on-site at your facility. We also develop custom safety programs for industrial, commercial, utility, and government installations. Visit www.avotraining.com or call 877-594-3156 for more information. AVO Training Institute 4271 Bronze Way Dallas, Texas 75237 877-594-3156 www.avotraining.com 8