KOBOLD PSR/PS FLOW SWITCH

Similar documents
QVE1901U Flow Switch. Technical Instructions Document No September 20, Description. Features. Application.

FSW300 Series Flow Switch

1592P01. for liquids in piping DN max. DC 48 V, 1 A, 20 W

! WARNING. Before using product, read and understand instructions.

1592P01. for liquids in piping DN

! WARNING. Before using product, read and understand instructions.

Flow switch. Operating Manual. English manual page Page 1 of 15 Fax:

! WARNING. Before using product, read and understand instructions.

Blue Ribbon Corporation

INSTRUCTION MANUAL MM-601REVI. Series FS4-3 General Purpose Liquid Flow Switch

INSTALLATION INSTRUCTIONS

Installation Instructions PP-AS20 Anti-Scale System

INSTALLATION INSTRUCTIONS

Model EPWHP. How to install, operate and maintain your Water Heater Protector. Do not return unit to store

INSTRUCTION MANUAL MM-615E. Series FS1 High Sensitivity Liquid Flow Switch

THERMAPHASE INSTALLATION AND OPERATING INSTRUCTIONS

Parts & Material Included

COMPRESSED AIR DRYER. SAFETY... Page 2 MAINTENANCE... Page 5. INSTALLATION... Page 3 PARTS AND KITS... Page 6

AV17 Series Switch-Tek Manual Direct and Remote Drum Mount Float Alarm 17 SEPT 08 Rev A

OptiSoft Softeners Simple Install Steps 1-17

Process Water Heater For Industrial Applications All Voltages, Single or Three Phase Up To 88 KW

IMPORTANT SAFETY INFORMATION READ ALL...

INFINITY FLUIDS CORPORATION

Acrylic Claw Foot Tub

Model ESFR-17 Dry Type Pendent Sprinklers Early Suppression Fast Response 16.8 K-factor General Description

PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST PLYMOUTH BELVEDERE

INSTALLATION & TESTING MANUAL

SUPERIOR SOFT-TEC NO SALT WATER SOFTENER Installation & Operation Manual

INSTALLATION & TESTING MANUAL

Model NOTE TO INSTALLER: Please leave this information with the Maintenance Department. LIMITED WARRANTY

TITAN VI High Efficiency Water Conditioner Installation and Operation Manual

TUB AND SHOWER FAUCET

EEMAX SERIES-TWO WATER HEATERS

TABLE 1 Electrical Specifications

Installation & Service Guide

WAIWELA SERIES-TWO WATER HEATERS

TITAN Pro-Max High Efficiency Upflow Water Conditioner Installation and Operation Manual

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL AUTOBOOSTER IMPORTANT SAFETY INFORMATION

Installation Instructions

Instructions CH Chrome SS Stainless Steel Certifications. Single Handle, Pull-Down, Kitchen Faucet. Tools Required.

TABLE 1 Electrical Specifications. Phase

! WARNING. Replacement Head Mechanism INSTRUCTION MANUAL MM-413F

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

TITAN FLOW CONTROL, INC.

installation, operation & Maintenance manual Floor-mounted Induction units

SIKA VK300 OR VK325 SERIES FLOW SWITCH Operating Manual

Series SFN Unbraided Flexible Hose Assemblies Series SFB Braided Flexible Hose Assemblies

Instruction Manual - Anti-Siphon Ejector Chlorine & Sulfur Dioxide 500 PPD (10 kg/h) Maximum Capacity

SMARTBOOST IMPORTANT SAFETY INFORMATION

One Less Thing to Forget...

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL TANKBUDDY IMPORTANT SAFETY INFORMATION

Controlled Energy Corp. 340 Mad River Park Waitsfield, VT TOLL FREE

The Inlet and Outlet should be as per below illustration. This will ensure that water will flow through the filter in an upflow configuration

Circulation heaters for ATEX/IECEx hazardous areas or in non-atex version

MP-MBA-45T-1/60T-1 / 75T-1

Installation and Maintenance "L" and "LS" Series

SERVICE MANUAL (v1) UL / ULC. WET CHEMICAL HAND PORTABLE RESTAURANT KITCHEN FIRE EXTINGUISHERS Model: SF-6LK / WBDL-6LK

Instructions. 110-KVD-CYSCH-AD-Z Chrome 110-KVD-CYSSS-AD-Z Stainless Steel Certifications. Single Handle, Pull-Down, Kitchen Faucet

DIRTMAG dirt separator with magnet, adjustable for vertical or horizontal pipe

FS80-C Flow Switch. Features and Benefits. Allows user select the setting according the needs of system

Model ESFR-17 Dry Type Pendent Sprinklers Early Suppression Fast Response 16.8 K-factor General Description

THERMOMETER INSTALLATION, OPERATION AND MAINTENANCE

RAPID RESPONSE Model RSV-1 Residential Shut-Off Valve, Dual-Purpose Water Supply, Domestic and Fire Sprinkler System General Description

7500-S Sediment Backwash Filter Guide

Installation, Operation and Maintenance Guide G3600 Series Thermostatic Mixing Valves

ARIN THERMOSTATIC SHOWER SYSTEM

Torq N Seal. Operating and Maintenance Instructions. Mechanical Tube Plugs

REF. NO Clamp Assembly 8 1 set Gasket (4 per set) S.S. Lock-washer 3/8 x 1/ Brass Impeller 3.

INTRODUCTION / TABLE OF CONTENTS

"S" SERIES IMMERSIBLE PUMP OWNER'S MANUAL INSTALLATION OPERATION PARTS Models S2 S4 S5 SS6 SS7 S8

VADA - Rain2Main Automatic Rainwater Controller

INSTALLATION AND OPERATING INSTRUCTIONS FOR RW519 RAIN WATER FILTRATION SYSTEM

Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K Upright, and Pendent Extended Coverage Light and Ordinary Hazard General Description

Models Series Series

! WARNING. Before using product, read and understand instructions.

A B A B4

HydroCycle Vertical Aeroponic Systems

KC22/32 SERIES Sealless Non-Metallic Centrifugal Pumps Installation and Maintenance Instructions

Installation, commissioning and servicing instructions

Genesis Whole House Chlorination System Page 2

HydroCycle Vertical Aeroponic Systems

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR PIPE THREAD IMMERSION HEATERS USED IN HAZARDOUS LOCATIONS

installation, operation & Maintenance manual acb ceiling-mounted cassette models

Armstrong J Series Float, Thermostatic Steam Traps, Condensate Controllers & Liquid Drainers Installation and Maintenance Manual

SEABREEZE. SeaBreeze Rain Shower System Model #1086-CH Owner's Manual

Autotrol Performa FA Valve

MOJAVE. Mojave ShowerSpa Model #1016 Owner's Manual

A.YITE GROUP (Hongkong & Shanghai)

WATLOW IND. WATROD Circulation Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 6/11/2008 Rev: 2.00

EEMAX ProAdvantage Series 1

A.YITE GROUP (Hongkong & Shanghai)

Instruction Manual for HX-DX and HX-DXHP Heat Exchangers 3 / 2017

Duct heaters for ATEX/IECEx hazardous areas or in non-atex version

Models Series Series

918 Clock Gauge Installation, Operation, and Maintenance Instructions

KELCO F29 PROGRAMMABLE FLOW SWITCH

Single Lever Pull Out Kitchen Faucet

Model AV1LED Audio-Visual LED Light Installation and Maintenance Manual

TIMES SQUARE TWO-HANDLE THERMOSTAT

Transcription:

KOBOLD PSR/PS FLOW SWITCH User Instructions KOBOLD Instruments Inc. 1801 Parkway View Drive Pittsburgh PA 15205 Phone (412) 788-2830 Fax (412)-788-4890 www.koboldusa.com Manual-PSR-PS_8-10

PSR/PS Table Of Contents KOBOLD PSR/PS FLOW SWITCH 1.0 General... 1 2.0 Specifications... 2 3.0 Installation... 5 3.1 Contact Protection... 5 4.0 Operation... 6 4.1 Adjusting Setpoint... 6 5.0 Maintenance... 7 6.0 Damaged Equipment... 7 7.0 Need Help with your PSR/PS... 7 LIST of DIAGRAMS Diagram 2.4 Diagram of Dimensions... 4 Diagram 2.5 Diagram of Pressure loss vs. Flow rate... 4 Diagram 4.2 Diagram of Reed Contact... 6 LIST of TABLES Table 2.1 Table of Technical Data... 1 Table 2.2 Table of Construction... 2 Table 2.3a & b Table of Switching Ranges... 3 Table 3.2 Table Reed Contact - Data... 5

1 PSR/PS KOBOLD PSR/PS FLOW SWITCH User Instructions CAUTION: For safety reasons, please read the cautionary information located at the end of the manual, before attempting installation. 1.0 General The KOBOLD PSR/PS flow switch is intended for applications in which an electrical switching function is required once a specific flow is achieved. The PSR/PS can be set to operate as either a normally-open (N/O) or normally-closed (N/C) switch. Switching is done with a reed contact which is electrically isolated from the flowing medium. The device operates through use of a paddle-spring arrangement. The flowing medium exerts force on the lower part of the paddle ( in the T-piece ). The paddle pivots about a point higher in the PSR/PS body but is resisted by a leaf spring. On the upper part of the paddle is a magnet, which moves as the paddle pivots about its center. A reed switch is located outside the PSR/PS housing ( thus hermetically isolated ) inside a movable plastic housing. As the magnet nears the reed switch, the switch closes. By moving the reed switch, the flow required to close it is altered. The result is a flow sensitive reed switch, with adjustable switch point. 2.0 Specifications Table 2.1: Technical Data Operating Principle: Spring resisted paddle Dimensions: See Diagram 2.4 Ranges: See Diagram 2.3a & 2.3b Maximum Pressure: Most Brass/SS units: 1450 PSIG (100 Bar) NOTE: PSR-5132 & PSR-5140: 360 PSIG (25 Bar) Maximum Medium Temperature: 230 Degrees F (110 Degrees C) Maximum Ambient Temperature: 150 Degrees F ( 65 Degrees C) Reed Switch Specifications: See Table 3.2

PSR/PS 2 Table 2.2: Construction Housing (1,4,6) Brass SS Impact Plate (3.1) Leaf Spring (3.4) 304 SS 304 SS 301 SS 301 SS Lever (3.2) 301 SS 301 SS Locking Plate (5) Housing (7) Brass Polyamide GFR* Brass Polyamide GFR* Cabling (8) PVC PVC O-Ring (2) Buna-N Viton Magnet (3.3) Ceramic Ceramic *GFR - Glass Fiber Reinforced

3 PSR/PS Table 2.3a: Switching Ranges - PSR Stand Conn. NPT Stand. switching ranges Increasing Decreasing GPM Water GPM Water Flow switch model PSR Brass SS 1/4 0.9-1.3 0.6-1.2 PSR 5105 PSR 5205 3/8 1.0-1.6 0.7-1.5 PSR 5110 PSR 5210 1/2 1.3-2.1 1.0-2.0 PSR 5115 PSR 5215 3/4 3.0-4.0 2.2-3.0 PSR 5120 PSR 5220 1 3.2-5.0 2.4-4.5 PSR 5125 PSR 5225 1 1/4 4.9-8.5 3.8-7.8 PSR 5132 PSR 5232 1 1/2 9.2-15.0 7.9-14.3 PSR 5140 PSR 5240 Table 2.3b: Switching Ranges - PS Pipe Size Stand. switching ranges Increasing Decreasing GPM Water GPM Water Stand. conn. NPT Flow switch Model PS Material Brass SS 2 18-24 16-22 1/2 3 48-66 45-62 1/2 4 84-106 79-101 1/2 6 185-242 176-237 1/2 2 13-16 11-15 1/2 3 41-48 38-44 1/2 4 57-70 53-66 1/2 6 147-159 137-156 1/2 4 24-30 19-27 1/2 6 53-75 44-62 1/2 8 101-141 88-123 1/2 PS-5149 PS-5152 PS-5114 PS-5249 PS-5252 PS-5214

PSR/PS 4 Diagram 2.4 Dimensions - PSR/PS Order Number Dimensions (inches) Thread A B C D HEX1 HEX2 (NPT) PS-5149/PS-5249 3.66 2.32 1.34 0.78 0.87-1/2" PS-5152/PS-5252 5.25 2.22 3.03 0.75 1.06 1.18 1/2" PS-5114/PS-5214 7.55 4.52 3.03 0.75 1.06 1.18 1/2" PSR-5105/PSR-5205 1.97 0.39 3.15-1.06 1.18 1/4" PSR-5110/PSR-5210 1.97 0.39 3.15-1.06 1.18 3/8" PSR-5115/PSR-5215 1.97 0.39 3.15-1.06 1.18 1/2" PSR-5120/PSR-5220 2.05 0.59 3.21-1.25 1.18 3/4" PSR-5125/PSR-5225 2.2 0.59 3.31-1.54 1.18 1" PSR-5132/PSR-5232 2.6-3.5-1.97 1.18 1 1/4" PSR-5140/PSR-5240 2.6-3.62-2.36 1.18 1 1/2" Diagram 2.5: Pressure Loss vs. Flow Rate Pressure Drop: The pressure drop of the flow switch is mostly due to the size of the paddle and resulting resistance to flow. The data given in the diagram is valid for units with the standard set point ranges. The pressure drop is less for units with the special set point ranges in the table. The set point ranges are those over which the contact can be adjusted. The high grade stainless spring steel beam enables actual flow rates to be significantly higher without causing damage. There would however be a higher pressure drop.

5 PSR/PS 3.0 Installation Instructions CAUTION: For Safety reasons, please read the cautionary information located at the end of the manual, before attempting installation. The PSR/PS is installed directly in the pipeline. The PSR/PS is supplied with NPT threads. Use of teflon tape is recommended to aid installation. Note that the PSR must be installed so that flow direction in the pipe is as indicated by the arrow on the T-piece. The flow direction arrow on the PS series is stamped on the clamp plate. The reed contact is simply an open/closed type of switch - connect appropiately. Ensure that loads on the switch do not exceed the maximum ratings as given in Table 3.2. Remember that capacitive and inductive loads (such as motors) exhibit much greater voltage/current requirements at start-up and shut-down than the typical operating values. 3.1 Contact Protection Maximum values of current and voltage may not be exceeded on the reed relay. When driving inductive or capacitive loads, we recommend the use of an isolation relay. KOBOLD supplies a line of relays for such instances. Table 3.2: Reed Contact - Electrical Data Maximum Current: 1.5A Maximum Voltage: 250 VAC Maximum Power Dissipation: 50 VA / 50 W Electrical Cable Length: 5 ft. Environmental Protection: NEMA 4 / IP 65

PSR/PS 6 4.0 Operation As described in Section 1.0, the PSR/PS uses a paddle to activate a reed contact located at the top of the instrument. The reed contact is simply a switch, and should be wired as such. 4.1 Adjusting the Setpoint Diagram 4.2: Adjusting the Setpoint The PSR/PS is adjusted at the factory as a normally open switch, and to switch in approximately the middle of its range. To change the setpoint, consult Table 2.2: Construction, and do as follows: Loosen the clamp plate screws (5) to allow movement of the reed contact (7). Decide, at this point, whether you want a normally open (N/O) or normally closed (N/C) switching function. The switch functions as an N/O switch when the switch assembly (7) is positioned such that the red arrow is emerging from flow switch housing (4). The switch functions as an N/C switch when the switch assembly (7) is positioned such that the white arrow is emerging from flow switch housing (4). The switch is more sensitive to flow (i.e activates at a lower flowrate) as more of the arrow is pulled out of the housing. When the red arrow is nearly completely pulled out of the flow switch housing, the switch function will transition from N/O to N/C. The N/C switching sensitivity can then be adjusted by pulling the switch assembly further out of the flow switch housing.

7 PSR/PS Note: If during adjustment, the switch assembly (7) is pulled too far out of the flow switch housing (4), the switch will not function when the impact plate (3.1) is deflected. If this occurs, simply slide the switch assembly back into the housing until the contact functions as desired. 5.0 Maintenance Due to the simple construction of the PSR/PS, it is nearly maintenance free. Should cleaning ever be required, simply release pressure in your system, loosen the lock nut (Diagram 2.2, Item 6) on the PSR/PS and pull the body straight up. Clean as necessary and replace. During replacement, note that the pivot plate of the balance arm (Item 3.2) is keyed to the T-piece (Item 1). The instrument must be reassembled with the keys properly aligned in order to function properly. 6.0 Arrival of Damaged Equipment Your instrument was inspected prior to shipment and found to be defect-free. If damage is visible on the unit, we advise that you carefully inspect the packing in which it was delivered. If damage is visible, notify your local carrier at once, since the carrier is liable for a replacement under these circumstances. If your claim is refused, please contact KOBOLD Instruments for further advisement. 7.0 Need help with your PSR/PS Call one of our friendly engineers at 412-788-2830.

9 PSR/PS Caution PLEASE READ THE FOLLOWING GENERAL FLOW METER / MONITOR WARNINGS BEFORE ATTEMPTING INSTALLATION OF YOUR NEW DEVICE. FAILURE TO HEED THE INFORMATION HEREIN MAY RESULT IN EQUIPMENT FAILURE AND POSSIBLE SUBSEQUENT PERSONAL INJURY.

PSR/PS 10 KOBOLD manufactures a wide range of process sensors and technolgies. While each of these technologies are designed to operate in a wide variety of applications, it is the user s responsibilty to select a technology that is appropiate for the application, to install it properly, to perform tests of the installed system, and to maintain all components. The failure to do so could result in property damage or serious injury. Inspect instrument for damage upon arrival. Cracked, fractured, bent, or otherwise damaged instruments must not be put into use, since the device is weakened to an unknown extent. (The opeartions and installation guide will explain how to make a claim on damaged instruments.) Make sure that the model which you have selected is chemically compatible with the application liquids. While the meter is liquid and spray resistant when installed properly, it is not to be immersed. Under NO circumstances must the maximum tolerances (temperature and pressure) be exceeded. The maximum tolerances of the device have been determined using water, air and/or oil. If using other media, especially corrosive ones, it is critically important that the user determine chemical compatibility with our instruments. A list, detailing material composition of our instruments, is available from KOBOLD Instruments Inc. upon request. KOBOLD Instruments Inc. cannot accept responsibilty for failure and consequences resulting from use of media other than water, mineral oil, air, and nitrogen. Install the devices in a fully supported position within your flow system. This avoids excessive stresses which may damage the instrument. In particular: a. Ensure that the plumbing leading to and from the instrument is fully supported and that the instrument does not perform the physical function of a joint. b. When calculating stress on the device caused by plumbing, the weight of the medium in the pipes must be considered as well. c. Misaligned runs of rigid piping can cause large stresses when connected to the instrument. Do not connect in such a fashion. During installation, avoid stresses on the instrument by following guidelines given below: a. When connecting fittings, hold the instrument fittings rigid with a correctly sized wrench. Do not install by twisting the instrument into the pipe fittings. b. Do NOT install holding the device housing to provide counter-torque to the pipe fitting.

11 PSR/PS c. Use an appropiate amount of teflon tape on male threads of fitting. This reduces the twisting stresses produced by tightening the fittings into each other. d. Do not use pliers or wrenches on the housing, as this may damage it. e. Do not overtighten, as this may fracture the fittings. During operation, there are a number of situations to avoid: a. The sudden cessation of fluid flow causes what is typically referred to as water hammer. Most people are famailar with this phenomenon from their home experience - it is the cause behind the loud clank of water pipes which occurs when faucets are turned off too suddenly. The cause behind this water hammer is quite easy to visualize. Water is fairly massive. The amount of water in long runs of pipe is quite substantial. When the faucets are turned off suddenly, especially from a full on condition, the water has considerable momentum and does not want to stop flowing. The situation is similar to stopping a car by running into a wall, rather than by applying brakes. Both are sudden rather than gradual. The damage to the wall can be substantial (not to mention the car). The water hammer causes surges in fluid pressure which could cause the measurement instrument s pressure limit to be exceeded, resulting in failure and possible personal injury. b. Fluid surges, as well as the water hammer, can be particularly damaging to empty flow meters since there is no back pressure in the device. The damage is caused, once again, by momentary excess pressure. To avoid these surges, fluid lines should remain full (if possible) and water flow should be introduced to the device slowly. c. If the instrument is isolated with inlet and outlet valves, the flow meter must be completely drained when said valves are both closed. Failure to do so could result in damage to the device caused bt thermal expansion of fluid. d. Freezing of water in the instrument must be avoided since the resultant expansion will damage the flow meter and make it unsafe for use. Design a fail-safe system a. Design a fail-safe system that accomodates the possibilty of switch or power failure. In critical applications, KOBOLD recommends the use of redundant backup systems and alarms in addition to the primary system.