A10. Installation & Operation Manual. Flow Switch. For the latest version of this manual, visit kteksolidslevel.com.

Similar documents
Installation Manual. THM-0100 Setpoint Thermostat Version THM HBX Control Systems Inc.

Installation, Operation & Service Manual

INSTALLATION AND OPERATING INSTRUCTIONS FOR THE VEHICLE-MOUNTED RADIATION DETECTION SYSTEM

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

Model NT20e Installation Guide

DBF 4XL Dryer Booster Fans

WMWLB / WMWFM / WTWLB / WTWFM Series Hydronic Heating Unit

DESCRIPTIVE AND INSTALLATION INSTRUCTION MANUAL FOR MODEL G1000 AND H1000 SERIES ANNUNCIATORS

Installation Guide

XT Series Thermostats

INSTALLATION, OPERATION AND MAINTENANCE

1022 R/T Remote Monitor

Installation and Operations Manual

Installation and Operating Instructions

Remote Relay Module (RRM)

DUST FREE CARBON Whole House Air Purifier

DESCRIPTIVE AND INSTALLATION INSTRUCTION MANUAL FOR MODEL AH1000, BH1000, AND EH1000 SERIES ANNUNCIATORS

Installation Manual. Expansion Module 0100 Version 1.0 EXP HBX Control Systems Inc.

Filter Oven with Controller 101FRDC00-50 / 101FRDC00-CTRL

CLIMAGUARD Air-to-Air Outdoor Heat Exchangers INSTRUCTION MANUAL. Rev. H 2015 Pentair Equipment Protection P/N

RATIO:GUARD Model E-1S EC Monitor

Instruction Manual. Nacho Cheese Dispenser and Warmer

Power Conditioners User s Manual. For use with Standard Power Conditioners, Medical Power Conditioners and Ground Guard Power Conditioners

M Series Fan Filter Units

CVS Model Inline Multi-Port Ventilators

IAQ Series. Bosch IAQ Photo Catalytic Oxidizer (PCO) Residential Application. Installation Manual and Owner s Guide

Controllers. Instruction Manual WARNING

Thermal Dispersion Flow, Level, Granular Solids & Temperature Switch

10810 W. LITTLE YORK RD., STE. 130 HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!

Instruction Manual WARNING

Series: MBC1-TC Mini Benchtop Temperature Controller

Easy installation in both new construction and retrofit. ZB90C ZB110C X2 Multi-Speed Ventilation Fan INSTALLATION GUIDE

GAS MONITOR Model Model

Users Manual. LAURUS Systems, Inc. - Ph: Fax:

DECORATIVE GAS LOG PLACEMENT INSTRUCTIONS

Installation Instructions

Fan Speed. Auto Swing. Timer. Power. Mode. Fan. Only. Saver. Temp. Dry. Fan. Speed. Auto Swing. Timer. Power. Mode. Saver. Only. Temp.

BX Series. Installation, Operation, Maintenance Instructions & Spare Parts

WKS 4000 SERIES (USA only) --INSTALLATION INSTRUCTIONS--

Ultrasonic Reflective Sensor

Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL.

Panel Mounted Heat Exchangers by Dantherm, Inc.

3800 North Mill Road Vineland, NJ USA Tel: Fax: Web: Rev. A

Viessmann B1HA Boiler Series

120 VAC SYSTEM CONTROL KIT Model: CK-63

Installation & Operation Manual Ice Cream Freezers

Single Phase Simplex SXL21=3, SXL24=3, SXH21=3, and SXH24=3

120 VAC SYSTEM CONTROL KIT

SONANCE ORIGINAL SERIES MEDIUM IN-WALL SPEAKERS

Three Phase Simplex. Installation (937) Installation Instructions and Operation/Troubleshooting Manual. Installation of Floats.

Spy model 673 wet sponge holiday detector ope rati ng instructions

Use this product according to this instruction manual. Please keep this instruction manual for future reference. MODELS: ST-H15-B & ST-H30

MODEL 925W FEATURES: ELECTRICAL DATA: DIMENSIONS: SHIPPING INFORMATION: FOOD WARMING/ MERCHANDISING CABINET

SYSTEM CONTROL KIT Model: CK-41P

Operating Instructions Manual. Condensate Separators. Models 4GNL3 thru 4GNL9 and 53RG84 thru 53RG95

6502B RF Distribution

Operation and Maintenance Manual

RecoverX Oil-Filled Hermetic Refrigerant Recovery System. Operation and Maintenance Manual

PreView WorkSight. WS6220 WS6215 WS6210 Sensor Operating Manual.

OWNERS MANUAL For IN ROOM BREWING SYSTEM MODEL REFILLABLE CAPSULES K901. Includes: Installation Use & Care Servicing Instructions

Instruction Manual. 36 in. and 42 in. Popcorn Staging Cabinets

AV17 Series Switch-Tek Manual Direct and Remote Drum Mount Float Alarm 17 SEPT 08 Rev A

Instruction Manual. Dogeroo, Super Dogeroo, and Mini Dogeroo

Operating Instructions & Parts Manual. Silent Low-Profile Ceiling Fans. Models 3DPE2A, 3DPE3A, 1UBH6B, 1UBH7B, 1UBH8A, 5AE68B, 5AE69A

Mini rad-d User's Manual - February 22, 2010

Surge Protective Devices Installation, Operation and Maintenance Manual. LowProfile Series: 080 and 120

Xaact Spot. Xaact Hot Spot

Intelligent Electronic Enclosure Thermal Management Systems

LUDLUM MODEL ALPHA, BETA, GAMMA HAND DETECTOR. June 2016 Serial Number and Succeeding Serial Numbers

Easy installation in both new construction and retrofit

Low Temperature Stainless Steel Panel Series Installation and Commissioning Guide

Pressurized Filter Up to 1250 gallons

SPA BLOWER OWNER'S MANUAL XXXX, XXXX, XXXX, XXXX, XXXX, XXXX fax

Inline Heater for Solvent or Gas. Installation and Operation Manual

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Ice Cream Freezers

PROAIR Water-Cooled Air Conditioner. CR43WC Model INSTRUCTION MANUAL

Easy installation in both new construction and retrofit

OPERATIONAL & INSTRUCTION MANUAL. Model: 2400FA (120v 1Ø) Model: 3200FA (220v-240V 1Ø) Voltage Supply to Machine:

Wrap-Around TOTE Tank / IBC Heaters (TOTE and TOT Series)

! "! # Please read these installation and operating instructions completely and carefully before starting.

Owner s Manual. 5+2 Day Programmable Digital Thermostat

GASGUARD NH 3. Ammonia Sensor OPERATING & INSTALLATION MANUAL

QAS-101 SERIES SINGLE CHANNEL CONTROLLERS

Twin Photobeam Detectors Manual

FOR EASY, FAST INSTALLATION AND FOR RESULTS

Owner s Manual. PIR-1 IR Learner

OPERATIONAL & INSTRUCTION MANUAL. Model: 2400FA (120v 1Ø)

HotPoly Tote Tank / IBC Heaters (TTH Series)

Level Alarm Control. Blender Accessories U S E R G U I D E UGB

Owner s Manual. Digital Thermostat

Eliza Hugger 56 CEILING FAN

TL-105 COLUMN HEATER

MACURCO INC. CONTROLLERS & CARBON MONOXIDE DETECTORS SS103-3A, SS103-10A SS102H, SS102HC-1 INSTALLATION & OPERATING INSTRUCTIONS

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

IMPORTANT INFORMATION - PLEASE READ CAREFULLY

PodView Level Indicator LI40 Series Manual

OmniDry 2.9 Amp Centrifugal Air Mover

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

Blade Series Heat Exchanger Operation and Installation

Rev. A AUGUST 2012 RNP SERIES REFRIGERATED COMPRESSED AIR DRYERS OPERATOR MANUAL RNP25 RNP35 RNP50

Transcription:

Installation & Operation Manual A10 For the latest version of this manual, visit kteksolidslevel.com. K-TEK Solids Level l 6100 West by Northwest #140 l Tel: +(1) 713.462.7665 l Toll Free 800.245.7056 l Houston, TX 77040 USA Fax: +(1) 713.462.7684 Email: sales@kteksolidslevel.com l Website: kteksolidslevel.com

TABLE OF CONTENTS 1.0 General Description...3 2.0 Installation and Calibration...3 3.0 Operation...6 4.0 Maintenance and Troubleshooting...6 5.0 Customer Support...7 5.1 K-TEK Solids Level RMA Form...8 6.0 Warranty Statement...9 FIGURES Figure 1 Overall Dimensions...3 Figure 2 Suggested Mounting...4 Figure 3 Typical Mounting Arrangement...4 Figure 4 Typical Field Wiring Diagram...5 Figure 5 Location of Adjustment...5 Figure 6 Kasiflo Block Diagram...7 A10-0200-1 Rev a (10-2010) DCN0528 For the latest version of this manual, visit kteksolidslevel.com. 2

1.0 General Description The K-TEK Kasiflo Model A10 detects, without contact, dry material flowing in a system. The unit can detect flow in spouts, pipes, ducts and tanks without penetrating the vessel wall. It is sensitive enough to work through most standard bin and duct liners, yet selective enough to ignore normal plant background noise. A10 Installation consists of mounting the unit with two bolts so that its sensing surface is in contact with the outside wall of the vessel in which flow is to be monitored. Wiring of the power and alarm circuits is dictated by the unit s environment and by the type of application in which it is used. A 3/4 inch conduit entry is provided. The unit operates in the 40 KHz region, thereby ignoring audible noise and most plant interference. It is also adjustable to reject background noise and vibration. In addition, the built-in time delay assures positive sensing. 2.0 Installation and Calibration After unpacking the unit, inspect it for any evidence of shipping damage. Any claims for damage due to shipping must be filed with the carrier who handled the package(s). Select a mounting location for the unit on the duct in which flow is to be sensed. The mounting location should be away from noisy or vibrating machinery if possible. Even 12 inches away from such machinery is helpful. The back of the box should be firmly in direct contact with the outside surface of the duct in which material is flowing. When material flow is due to gravity, the flow switch should be mounted on the bottom side of the duct. In pneumatic conveying systems, the flow switch may be able to work on the sides of the duct as well as the bottom. The top of the duct should generally be avoided as a mounting location. Figure 1 Overall Dimensions The flow switch will work well with many types of lined duct work, but if the duct has two layers of material with an airspace between, special mounting methods may be necessary. See Figure 3 for typical mounting locations. Figure 4 shows a typical arrangement that may be sued with round piping or duct work. Connect the field wiring to the flow switch as show in Figure 3 or as required for a particular application. Figure 3 shows one, and only one, of many possible applications of Kasiflo. The remote indicator lamp shown in this figure might be located on an operator s graphics panel so that the operator would know when material is flowing at the location being monitored by the Kasiflo. CAUTION: Be sure that all wiring conforms to the requirements of the national Electrical Code and any other enforcing authorities or agencies having jurisdiction over the installation. Be sure that any specific conditions such as areas having explosion hazards are given full consideration. A10-0200-1 Rev a (10-2010) DCN0528 For the latest version of this manual, visit kteksolidslevel.com. 3

Figure 2 Suggested Mounting K-TEK Model A10 Optional mounting adaptor plate kit (available from K-TEK or your distributor) Figure 3 Typical Mounting Arrangement for Round Pipe or Duct A10-0200-1 Rev a (10-2010) DCN0528 For the latest version of this manual, visit kteksolidslevel.com. 4

Figure 4 Typical Field Wiring Diagram Figure 5 Location of Adjustment and Controls Test the flow switch for proper operation. As the unit is shipped from the factory, it is set for maximum sensitivity and will work well in many applications with no further adjustment. In some cases where there is a considerable amount of nearby vibration or noise, it may be necessary to adjust the sensitivity to compensate for the noise or vibration. With no material flowing in the duct, apply power to the flow switch and observe the remote indicator light. The lamp should remain off. If the lamp lights or flashes erratically, the flow switch will require adjustment. If the lamp remains off, the next step is to cause a flow of material in the duct. Approximately one second after material begins flowing over the unit, the lamp should come on. When material ceases to flow, the lamp should go out immediately. if required, calibrate the Kasiflo using the procedures which follow. See Figure 5 for location of adjustments and controls. Adjustment Procedure The purpose of this adjustment is to set the flow switch in such a manner that when the flow switch hears product flowing in the duct, the relay will be energized. When product is not flowing, the relay will be de-energized. The CALI- BRATION POTENTIOMETER is used to set the flow switch to a particular installation. Once it is set, it should not require further adjustment unless the installation is changed or the unit is moved to a different duct. The INDICATOR LIGHT is used to determine the proper setting of the calibration potentiometer. Once the flow switch is properly calibrated, the indicator light will show presence or absence of material flow in the duct. Once the flow switch is properly installed and has been tested, use the following procedures to calibrate the unit, if necessary, to the particular installation. The only equipment required is a small screwdriver to adjust the calibration potentiometer. CAUTION: If the flow switch is mounted in a hazardous atmosphere, it will be necessary to follow all required procedures, such as ventilation, hot work permits, etc. Read all the following steps before beginning: Step 1: Before beginning adjustment, be sure that all machinery in the general area is operating normally and that no material is flowing in the duct.\ Step 2: Make sure that the power is off, then remove the cover of the enclosure. NOTE: There are 20 complete turns of the calibration potentiometer from one end to the other. When one or the other end is reached, the adjustment screw will continue to turn and freewheel (without damage) until the direction of the rotation is reversed. Step 3: Restore power to the unit and observe the indicator light. A. If the indicator light is off, turn the potentiometer clockwise until the light comes on. Proceed to B. B. If the indicator light is on, turn the potentiometer counterclockwise until the light goes out. Turn the potentiometer 1/8 turn further counterclockwise. Now cause material to flow in the duct. The light should come on and remain on until flow stops. Step 4: Remove power from the unit, replace the cover and re-apply power. This completes the calibration of the flow switch unit, and it is now ready to operate. A10-0200-1 Rev a (10-2010) DCN0528 For the latest version of this manual, visit kteksolidslevel.com. 5

3.0 Operation No operator actions are required to use this unit. When material is flowing in the duct, the really will energize. Since the relay contacts may be used in a number of different ways, the operator should know what to expect when a change of condition occurs and be prepared to take any action required by the system in which the Kasiflo is used. 4.0 Maintenance and Troubleshooting No routine maintenance is required other than keeping the interior of the unit clean and free of dirt, dust and other contaminants. The Kasiflo consists of two main sub-assemblies. These are the enclosure with the ultrasonic transducer attached and the printed circuit board assembly. The following troubleshooting guide will assist in determining how to correct most of the problems that may be encountered. Review the Installation and Calibration procedures in section 3 prior to using this guide. Problem Possible Cause Solution LED cannot be adjusted to turn on. Ultrasonic transducer not connected. Plug transducer cable into circuit board cable. No AC power to unit. Bad circuit board. Check for 90 VAC to 130 VAC at terminals L1 & L2 on circuit board. Replace circuit board assembly. LED remains on at all times. Material actually flowing in system. Interrupt flow to confirm proper operation. Unit triggers when material flows in duct, but will not reset when material stops flowing or unit gives false alarms. Excessive vibration or machinery noise at sensing location. Bad circuit board. Unit set too sensitive for application. Reduce noise or vibration or relocate flow switch to a quieter location that will indicate desired flow. Replace circuit board assembly. Perform ADJUSTMENT PROCE- DURE beginning at Section 3.1. Unit will not detect flow of material. Sensitivity set improperly. Perform ADJUSTMENT PROCE- DURE beginning at Section 3.1. Flow switch operates properly, but no signal at relay terminals. Bad circuit board. Burned or broken lands on circuit board. Replace circuit board assembly. Turn off power. Remove circuit board from housing and inspect lands from relay to terminals for damage. Replace if necessary. A10-0200-1 Rev a (10-2010) DCN0528 For the latest version of this manual, visit kteksolidslevel.com. 6

5.0 CUSTOMER SUPPORT Figure 6 Kasiflo Block Diagram K-TEK Solids Level (USA, Canada, International) 6100 West by Northwest #140 Houston, TX 77040 USA Tel: (1) 713.462.7665 Toll Free 800.245.7056 Fax: (1) 713.462.7684 Email: service@kteksolidslevel.com Website: kteksolidslevel.com A10-0200-1 Rev a (10-2010) DCN0528 For the latest version of this manual, visit kteksolidslevel.com. 7

5.1 K-TEK Solids Level RMA Form K-TEK Solids Level 6100 West by Northwest #140 Houston, TX 77040 USA Phone: (1) 713.462.7665 Fax: (1) 713.462.7684 Email: service@kteksolidslevel.com *** IMPORTANT CUSTOMER NOTICE: PLEASE READ PRIOR TO RETURNING PRODUCTS TO K-TEK*** Be sure to include the Return Authorization (RA) number on the shipping label or package to the attention: Customer Service. A copy of this document should also be included with the packing list. K-TEK Solids Level wants to maintain a safe work environment for its employees. In the event, the returned product or material has been in contact with a potentially hazardous chemical, per federal regulations, the customer must provide evidence of decantamination and the related chemical composition and characteristics. In order to expedite your return, please include the applicable Material Safety Data Sheets (MSDS) and decontamination tags by affixing these documents in close proximity to the shipment label for identification purposes. Return Authorization Form Customer: Contact Name: Contact Phone: Contact Email: Contact Fax: Date: Service Rep: Completed by Customer Product Serial Number Job Number Reason: Is expedited return shipping requested? If yes, please provide a purchase order or your shipper s account number (ex FedEx or UPS). K-TEK Solids Level pays return transport via standard ground shipments only. If purchase order is issued, a copy of purchase order must be included with return authorization documentation. Account #: Yes Is K-TEK Solids Level authorized to repair items determined to be non-warranty? If yes, a copy of purchase order must be included with return authorization documentation. Customer PO#: Has product been in contact with any potentially hazardous chemical? If yes, documentation product and forward MSDS to K-TEK Solids Level. ATTN: Customer Service Return Repaired Product to Address Shipping Address: Date: Billing Address: Yes Yes Ship Via: A10-0200-1 Rev a (10-2010) DCN0528 For the latest version of this manual, visit kteksolidslevel.com. 8

6.0 WARRANTY 3 YEAR WARRANTY FOR: KCAP 300 & KCAP 400 capacitance switches. 2 YEAR WARRANTY FOR: WT2000 radar level transmitters; KP paddle switches; A02, A75, & A77 RF capacitance level switches and A33 & A38 RF capacitance level transmitters; A22 Speed Switch; CP2 Conductance Switch. 1 YEAR WARRANTY FOR: LaserMeter series laser transmitters; DPM100 digital indicators; KVIEW series digital indicators and controllers; GranuPoint and SlurryPoint vibrating fork switches, SoliTrak Electro-Mechanical Continuous Measuring Devices, SonikTrak ultrasonic level transmitters & transducers, ChuteMaster Microwave Transmitter / Receiver and TiltMaster Switches. SPECIAL WARRANTY CONSIDERATIONS: K-TEK Solids does not honor OEM warranties for items not manufactured by K-TEK Solids (i.e. Palm Pilots). These claims should be handled directly with the OEM. K-TEK will repair or replace, at K-TEK s election, defective items which are returned to K-TEK by the original purchaser within the period specified above from the shipment date of the item and which is found, upon examination by K-TEK, to its satisfaction, to contain defects in materials or workmanship which arose only under normal use and service and which were not the result of either alterations, misuse, abuse, improper or inadequate adjustments, applications or servicing of the product. K-TEK s warranty does not include onsite repair or services. Field service rates can be supplied on request. If a product is believed to be defective, the original purchaser shall notify K-TEK and request a Returned Material Authorization before returning the material to K-TEK, with transportation prepaid by the purchaser. (Request door to door delivery via Houston International Airport located in Houston, TX, USA.) The product, with repaired or replaced parts, shall be returned to the purchaser at any point in the world with transportation prepaid by K-TEK for best-way transportation only. K-TEK is not responsible for expedited shipping charges. If the product is shipped to K-TEK freight collect, then it will be returned to the customer freight collect. If inspection by K-TEK does not disclose any defects in material or workmanship, K-TEK s normal charges for repair and shipment shall apply (minimum 250.00 USD). The materials of construction for all K-TEK products are clearly specified and it is the responsibility of the purchaser to determine the compatibility of the materials for the application. THE FOREGOING WARRANTY IS K-TEK S SOLE WARRANTY AND ALL OTHER WARRANTIES EXPRESSED, IMPLIED, OR STATUTORY, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OF FITNESS FOR A PARTICULAR PURPOSE, ARE EXCLUDED AND NEGATED TO THE MAXIMUM EXTENT PERMITTED BY LAW. NO PERSON OR REPRESENTATIVE IS AUTHORIZED TO EXTEND ANY OTHER WARRANTY OR CREATE FOR K-TEK ANY OTHER LIABILITY IN CONNECTION WITH THE SALE OF K-TEK S PRODUCTS. THE REMEDIES SET FORTH IN THIS WARRANTY ARE EXCLUSIVE OF ALL OTHER REMEDIES AGAINST K-TEK. K-TEK SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL, OR SPECIAL DAMAGES OF ANY KIND. K-TEK S SOLE OBLIGATION SHALL BE TO REPAIR OR REPLACE PARTS (FOUND TO BE DEFECTIVE IN MATERIALS OR WORKMANSHIP) WHICH ARE RETURNED BY THE PURCHASER TO K-TEK. A10-0200-1 Rev a (10-2010) DCN0528 For the latest version of this manual, visit kteksolidslevel.com. 9

For the latest version of this manual, visit kteksolidslevel.com. Houston, TX 77040 USA Tel: +(1) 713.462.7665 l Toll Free 800.245.7056 l Fax: +(1) 713.462.7684 Email: sales@kteksolidslevel.com l Website: kteksolidslevel.com A10-0200-1 Rev a (10-2010) DCN0528 For the latest version of this manual, visit kteksolidslevel.com. 10 K-TEK Solids Level l 6100 West by Northwest #140 l