EN :2012 EN :2012 ETAG 026 part 3:2011 DECLARATION OF PERFORMANCE. Sikasil -670 Fire

Similar documents
DECLARATION OF PERFORMANCE

DECLARATION OF PERFORMANCE

DECLARATION OF PERFORMANCE

DECLARATION OF PERFORMANCE

DECLARATION OF PERFORMANCE

Declaration of Performance

in accordance with Annex 111 of Regulation (EU) No. 305/2011 ( Construction Products Regulation ) ULTRA PROFLEX SP+ES GREY

See product BS EN :2010

DECLARATION OF PERFORMANCE. No EN

DECLARATION OF PERFORMANCE. No EN

DECLARATION OF PERFORMANCE. No EN

Firetect C. Fire protective products: Fire protective board

DECLARATION OF PERFORMANCE. No EN

European Technical Assessment ETA-14/0176

EUROPEAN TECHNICAL ASSESSMENT

Declaration of Performance

EUROPEAN TECHNICAL ASSESSMENT

DECLARATION OF PERFORMANCE. DoP: 0094 for Injection System fischer FIS V (Bonded anchor for use in concrete) EN

DECLARATION OF PERFORMANCE. No EN

Technical Assessment Body issuing the ETA and designated according to Article 29 of the Regulation (EU) No 305/2011: UL International (UK) Ltd

Declaration of Conformity Declaration of Performance Notes

CONSTRUCTION PRODUCTS REGULATION 2011 DECLARATION OF PERFORMANCE

DECLARATION OF PERFORMANCE. DoP: 0135 for fischer injection system FIS EM Plus (Bonded anchor for use in concrete) EN

DECLARATION OF PERFORMANCE. No EN. Post-installed fastening in cracked or uncracked concrete, see appendix, especially Annexes B 1 to B 9

DECLARATION OF PERFORMANCE. No EN. Annexes B 1 to B 4

Technical Bulletin CE marking: from 1st July 2013

EUROPEAN TECHNICAL ASSESSMENT

EUROPEAN TECHNICAL ASSESSMENT

DECLARATION OF PERFORMANCE. No EN. Post-installed fastening in cracked or uncracked concrete, see appendix, especially Annexes B 1 to B 4

CONSTRUCTION PRODUCTS REGULATION 2011 DECLARATION OF PERFORMANCE

European Technical Assessment

DECLARATION OF PERFORMANCE. DoP: 0124 for fischer Ceiling Anchor FDZ (Metal anchors for use in concrete (light-duty type)) EN

DECLARATION OF PERFORMANCE. No EN

European Technical Assessment

European Technical Assessment

Implementation of the Construction Products Regulation (CPR) in harmonized standards - Template for Annex ZA -

European Technical Assessment. ETA-10/0352 of 6 July English translation prepared by DIBt - Original version in German language.

DECLARATION OF PERFORMANCE. No EN. Post-installed fastening in cracked or uncracked concrete, see appendix, especially Annexes B 1 to B 6

1. Terms defined in the Construction Products Regulation (CPR)

European Technical Assessment. ETA-15/0440 of 6 July English translation prepared by DIBt - Original version in German language.

DECLARATION OF PERFORMANCE

European Technical Assessment. ETA-12/0166 of 18 June English translation prepared by DIBt - Original version in German language.

European Technical Assessment. ETA-10/0255 of 22 August General Part. Technical Assessment Body issuing the European Technical Assessment:

Guidance Note No 21/1. CE Marking Windows and doorsets to BS EN 16034

European Technical Assessment. ETA-02/0024 of 17 June English translation prepared by DIBt - Original version in German language.

European Technical Assessment. ETA-14/0125 of 26 May General Part. Technical Assessment Body issuing the European Technical Assessment:

European Technical Assessment. ETA-15/0771 of 14 December English translation prepared by DIBt - Original version in German language

European Technical Assessment. ETA-14/0030 of 26 June General Part. Technical Assessment Body issuing the European Technical Assessment:

SYSTEM DATA SHEET Sikafloor MultiDur ES-44 ESD

European Technical Assessment. ETA-13/0651 of 18 June English translation prepared by DIBt - Original version in German language.

European Technical Assessment. ETA-14/0028 of 22 September General Part. Technical Assessment Body issuing the European Technical Assessment:

European Technical Assessment. ETA-08/0315 of 15 May General Part. Technical Assessment Body issuing the European Technical Assessment:

ETICS and the EU Internal Market The European framework. G. Katsarakis European Commission, DG GROWTH Unit C-1: Clean technologies and products

F O C U S D O O R C L O S E R S

Regulation 574_2014: Annex III CPR. and. Regulation 568_2014: Annex V CPR

Guideline Construction Products Regulation (EU) 305/20122

European Technical Assessment. ETA-11/0492 of 26 June General Part. Technical Assessment Body issuing the European Technical Assessment:

Trade name of the construction product Injection system Hilti HIT-HY 110. This version replaces ETA-13/1037 issued on 17 January 2014

Declaration of Performance and CE marking of windows and external pedestrian doorsets according to the CPR

European Technical Assessment. ETA-14/0269 of 13 October General Part. Technical Assessment Body issuing the European Technical Assessment:

Guidance on Declaration of Performance and CE marking of windows and external pedestrian doorsets according to the CPR

Implementing the Construction Products Regulation (EU) 305/2011

European Technical Assessment. ETA-02/0020 of 11 December English translation prepared by DIBt - Original version in German language

European Technical Assessment. ETA-12/0605 of 4 May English translation prepared by DIBt - Original version in German language.

System Solutions. Quick and simple to construct. Range of partitions. Fully warranted systems. CE Marked. Knauf CE Marking. A guide to CE marking

European Technical Assessment. ETA-12/0084 of 14 April English translation prepared by DIBt - Original version in German language.

Cylinder Mortice Dead lock Lockcase(mm) A=87 Backset (mm) B=55. Follower (mm) 8 Latch Bolt

COMMISSION DELEGATED REGULATION (EU)

European Technical Assessment. ETA-14/0323 of 10 October General Part. Technical Assessment Body issuing the European Technical Assessment:

European Technical Assessment. ETA-08/0314 of 8 August General Part. Technical Assessment Body issuing the European Technical Assessment:

Trade name of the construction product Fix Master Injection system Fit-Ve 200 for rebar connection. Karhutie 9 Fl NURMIJÄRVI FINNLAND

Frequently Asked Questions on the Construction Products Regulation (CPR) - Enterprise and Industry

European Technical ETA-12/0084 Assessment of 3 February 2017 General Part

European Technical Assessment. ETA-16/0693 of 29 August English translation prepared by DIBt - Original version in German language.

European Technical Assessment. ETA-11/0240 of 7 May English translation prepared by DIBt - Original version in German language.

Introduction. Declaration of performance (DoP) CE marking

European Technical Assessment. ETA-11/0360 of 6 October English translation prepared by DIBt - Original version in German language.

YOUR GUIDE TO UNDERSTANDING CPR

European Technical Assessment. ETA-15/0296 of 27 August English translation prepared by DIBt - Original version in German language.

Implementation of the Construction Products Regulation (CPR) in harmonized standards - Template for Annex ZA -

Guidance Note No 19/1. CE Marking windows and doorsets

European Technical Assessment

European Technical ETA-15/0270 Assessment of 2 February 2016 General Part

European Technical Assessment

European Technical Assessment. ETA-14/0475 of 19 December English translation prepared by DIBt - Original version in German language

AC100-PRO Ice. Stanley Black & Decker Deutschland GmbH Richard-Klinger-Straße Idstein DEUTSCHLAND

CE marking of noise barriers and foundations

concrete Indo Spark Constructions services 198 E Tararani Chowk Near Geeta mandir KOLHAPUR Maharastra INDIEN

European Technical Assessment. ETA-16/0515 of 14 December English translation prepared by DIBt - Original version in German language

European Technical ETA-07/0332 Assessment of 30 January 2015 General Part

for concrete Apolo MEA Befestigungssysteme GmbH Industriestraße Aichbach DEUTSCHLAND Apolo MEA Befestigungssysteme GmbH, Plant2 Germany

European Technical Assessment. ETA-16/0107 of 22 March English translation prepared by DIBt - Original version in German language.

European Technical ETA-06/0078 Assessment of 21 January 2015 General Part

European Technical Assessment. ETA-99/0010 of 15 December English translation prepared by DIBt - Original version in German language

European Technical Assessment. ETA-13/0652 of 17 March English translation prepared by DIBt - Original version in German language.

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

GNB-CPR Position Paper: Issuance of certificates under CPR

For structural use in all types of construction works according to EN

European Technical Assessment. ETA-07/0121 of 30 March English translation prepared by DIBt - Original version in German language.

European Technical ETA-13/0909 Assessment of 8 December 2016 General Part

Transcription:

EN 15651-1:2012 EN 15651-4:2012 ETAG 026 part 3:2011 14 1104 DECLARATION OF PERFORMANCE Sikasil -670 Fire 02 05 14 03 0000 000 106 1. Product Type: Unique identification code of the product-type: 2. Type batch or serial number or any other element allowing identification of the construction product as required under Article 11(4): 3. Intended use or uses of the construction product, in accordance with the applicable harmonised technical specification, as foreseen by the manufacturer: 4. Name, registered trade name or registered trade mark and contact address of the manufacturer as required under Article 11(5): 5. Contact Address: Where applicable, name and contact address of the authorized representative whose mandate covers the tasks specified in Article 12(2): 6. AVCP: System or systems of assessment and verification of constancy of performance (AVCP) of the construction product as set out in CPR, Annex V: 7. Notified body (hen): In case of the declaration of performance (DoP) concerning a construction product covered by a harmonised standard: 8. Notified body (ETA): In case of the declaration of performance concerning a construction product for which a European Technical Assessment (ETA) has been issued: 9. 9.1 According to EN 15651-1:2012 Sikasil -670 Fire See packaging of the product EN 15651 Sealant for facade for interior and exterior application (intended for use in cold climates) F EXT-INT CC Sealant for pedestrian walkways PW INT ETAG 026 - part 3 Fire stopping and sealing product for linear joint and gap seal FI-02921 Espoo Not relevant EN 15651 System 3 for the type testing System 3 for the reaction to fire testing ETAG 026 - part 3 System 1 The notified body SKZ Tecona GmbH, identification number, performed the type testing and the testing of the reaction to fire and issued test report and classification report. The notified body Exova Warrington Fire, identification number 1104, issued European Technical Assessment 14/0474 on the basis of ETAG 026 part 3, edition 2011 www.sika.fi Page 1 / 8

Conditioning: Substrate: Method A Mortar M1, Sika Primer-3 N Essential characteristics Performance Test standard Harmonised technical specification Reaction to fire Class E EN ISO 13238 Classification acc. EN 13501-1:2010 Release of chemicals dangerous to the environment and health Water tightness and air tightness EN 15651-1:2012; 4.5 Resistance to flow 3 mm EN ISO 7390 Loss of volume 10 % EN ISO 10563 Tensile properties at maintained extension after water immersion (elastic) Tensile properties for nonstructural sealants used in joints in cold climate areas (-30 C) EN ISO 10590 EN ISO 8340 modified Secant tensile modulus at -30 C 0.9 MPa EN ISO 8339 Durability pass EN ISO 8339 EN ISO 8340 EN ISO 9047 EN ISO 10590 EN 15651-1:2012 www.sika.fi Page 2 / 8

9.2 According to EN 15651-4:2012 Conditioning: Method A Substrate: Mortar M1, Sika Primer-3 N Essential characteristics Performance Test standard Harmonised technical specification Reaction to fire Class E EN ISO 13238 Classification acc. EN 13501-1:2010 Release of chemicals dangerous to the environment and health Water tightness and air tightness Tensile properties at maintained extension EN 15651-4:2012; 4.5 EN ISO 8340 Loss of volume 10% EN ISO 10563 Tear resistance EN 15651-4:2012; 4.3.2.6 Adhesion/cohesion properties at maintained extension after 28 days water immersion Adhesion/cohesion properties at maintained extension after 28 days salt water immersion Tensile properties at maintained extension at -30 C Change of secant modulus <50% Change of secant modulus <50% EN 15651-4:2012; 4.4.1 EN 15651-4:2012; 4.4.1 EN ISO 8340 modified Durability pass EN ISO 8339 EN ISO 8340 EN ISO 9047 EN 15651-4:2012 www.sika.fi Page 3 / 8

9.3 According to ETAG 026 part 3, edition 2011 Essential characteristics Performance Test standard ETAG Safety in case of fire Reaction to fire Class E EN ISO 13238 Classification acc. EN 13501-1:2010 Resistance to fire Floor seals AAC-AAC E240 EI120-H-X-F-W 12-30 E240 EI60-H-X-F-W 31-50 Floor seals AAC-Steel E240 EI30-H-X-F-W 12-30 E180 EI30-H-X-F-W 31-50 Wall seals AAC-AAC E240 EI180-H-X-F-W 12-30 Wall seals AAC-Softwood E180 EI120-V-X-F-W 12 EI120-V-X-F-W 13-49 EI240-V-X-F-W 50 Wall seals AAC-Hardwood EI120-V-X-F-W 12-29 EI240-V-X-F-W 30-50 Wall seals AAC-Steel E240 EI60-V-X-F-W 12-29 E240 EI90-V-X-F-W 30-49 E240 EI120-V-X-F-W 50 Hygiene, health and environment Air permeability 0.0 m3/h at 100 Pa pressure differential EN 13501-2:2010 EN 1314-1 Water permeability EN 12155 Release of dangerous substances Mechanical resistance and stability Resistance to impact/movement Safety in use Adhesion, not relevant Airborne sound insulation Protection against noise Rw (C;C tr) = 38 (-2;-9) - - - EN ISO 140-3 Impact sound insulation - Energy economy and heat retention Thermal properties - Water vapour permeability Durability and serviceability General aspectsd Z 1 ISO 8339 ISO 9047 - ETAG 026 - Part 3 edition 2011 www.sika.fi Page 4 / 8

10. Declaration The performance of the product identified in points 1 and 2 is in conformity with the declared performance in point 9.This declaration of performance (DoP) is issued under the sole responsibility of the manufacturer identified in point 4. Signed for and on behalf of the manufacturer by: Ralf Heinzmann Global Technical Manager Sika Services AG TM Christian Völlm Corporate Product Engineer Sika Services AG TM Ecology, Health and Safety Information (REACH) For information and advice on the safe handling, storage and disposal of chemical products, users shall refer to the most recent Safety Data Sheet (SDS) containing physical, ecological, toxicological and other safety related data. www.sika.fi Page 5 / 8

14 020514040000000106 EN 15651-1: 2012 Sealant for facade for interior and exterior application (intended for use in cold climates) F EXT-INT CC EN 15651-4: 2012 Sealant for movement joints in floors for interior application PW INT Conditioning: Method A Substrate: Mortar M1/Aluminium, Sika Primer-3 N/ Sika Aktivator-205 Essential characteristics Performance Reaction to fire Release of chemicals dangerous to the environment and health Water tightness and air tightness EN15651-1:2012 Class E Resistance to flow 3 mm Loss of volume 10 % Durability Tensile properties at maintained extension after water immersion (elastic) Tensile properties for non-structural sealants used in joints in cold climate areas (-30 C) Water tightness and air tightness EN15651-4:2012 Tensile properties at maintained extension Pass Loss of volume 10 % Tear resistance Adhesion/cohesion properties at maintained extension after 28 days water immersion Adhesion/cohesion properties at maintained extension after 28 days salt water immersion Tensile properties at maintained extension at -30 C Durability, change of secant modulus <50%, change of secant modulus <50% pass www.sika.fi Page 6 / 8

1104 14 14/0474 ETAG 026 part 3, edition 2011 Linear joint and gap seal Essential characteristics Safety in case of fire Performance Reaction to fire Class E Resistance to fire Floor seals AAC-AAC E240 EI120-H-X-F-W 12-30, E240 EI60-H-X-F-W 31-50 Floor seals AAC-Steel E240 EI30-H-X-F-W 12-30, E180 EI30-H-X-F-W 31-50 Floor seals AAC-AAC E240 EI180-H-X-F-W 12-30 Floor seals AAC-Softwood E180 EI120-V-X-F-W 12, EI120-V-X-F-W 13-49 EI240-V-X-F-W 50 Floor seals AAC-Hardwood EI120-V-X-F-W 12-29, EI240-V-X-F-W 30-50 Floor seals AAC-Steel E240 EI60-V-X-F-W 12-29, E240 EI90-V-X-F-W 30-49 E240 EI120-V-X-F-W 50 Hygiene, health and environment Air permeability 0.0 m3/h at 100 Pa pressure differential Water permeability Release of dangerous substances Safety in use Mechanical resistance and stability Resistance to impact/movement Adhesion, not relevant Protection against noise Airborne sound insulation Rw (C;C tr) = 38 (-2;-9) Impact sound insulation Energy economy and heat retention Thermal properties Water vapour permeability General aspects Durability and serviceability Z 1 www.sika.fi Page 7 / 8

Legal note: This information is given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. In practice, the differences in materials, substrates and actual site conditions are such that no warranty in respect of merchantability or of fitness for a particular purpose, nor any liability arising out of any legal relationship whatsoever, can be inferred either from this information, or from any written recommendations, or from any other advice offered. The user of the product must test the product s suitability for the intended application and purpose. Sika reserves the right to change the properties of its products. The proprietary rights of third parties must be observed. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request. www.sika.fi Page 8 / 8