Vanilla Box Design Criteria

Similar documents
Library stacks and records storage 150 LB/SF live load

SPACE TYPE: JUDICIAL CHAMBER

PLAN REVIEW SUBMITTAL GUIDE

Unit # 1038 ± 900 SF Width ± 15' Depth ± 60'

Unit HH Gregg. ± 30,000 SF Width ±26' Lakeland Retail Center. Lease Outline Drawing. Unit HH Gregg. Depth ± 145' HVAC Units & Information

Unit # E ± 1,200 SF Width ± 20' Depth ± 60'

Proudly made in Canada. to Canadian Standards. The Statesman Series. 16 Wide Single Section Homes

Unit # H ± 2,000 SF Width ± 25' Depth ± 80'

SPACE TYPE: CHILD CARE

DIVISION 10 SPECIALTIES

Environmental Safety Risk Assessment Inpatient Behavioral Health Settings (Compiled from tools in the public domain)

Facility Condition Assessment Summary Report. British Columbia Institute of Technology NE6 - Plumbing and Pipefit Building

Plot # R019A ± 74' ± 74' ± 65' Plot # R019A LEASE OUTLINE DRAWING GROSS LEASABLE AREA ± 4,631 S.F. DEMISING FRONT WIDTH DEPTH ± 13' ± 32' Lease Line

About the Instructor & Presenter:

Paradise Marketplace. Unit # AOP +/- 1,600 SF +/- 12' +/- 11' +/- 8' 11'-7" +/- 85' +/- 74' +/- 20' MAIN FLOOR +/- 20' +/- 85' Width.

Electrical Information

UNIVERSITY OF ROCHESTER DESIGN STANDARDS FEBRUARY 2005MARCH 2007

About This Model. Series: Rockbridge Modular Homes Model: RJ501A Grand Rockwell. Style: Ranch / Bedrooms: 4 / Bathrooms: 2 / Square Feet: 2280.

Paradise Marketplace REAR FRONT. Unit # AOH +/- 1,700 SF +/- 20' +/- 85' +/- 85' +/- 20' MAIN FLOOR +/- 20' +/- 85' Width. Depth

SECTION FIRE EXTINGUISHER CABINETS

DESIGN AND CONSTRUCTION STANDARDS SPECIFICATION GUIDELINES

2 Main Office Building BLDG-955A Building Purpose Building Area Administration offices. Training room 7,610 SF Inspection Date August 16, 2016 Inspect

University of Rochester October 17, 2008 Brooks Landing Business Center

2. Interior doors shall be not less than 18 gauge steel.

Demountable Office Fronts. A Sustainable Interior Design Solution

Residential Accessibility Checklist - for Unit Types A and B With Connecticut Amendments Type A Units Accessibility Requirements rev.

KCKHA PRICE LIST 2015

Retreat in Luxury. About Us

REAR. Exit 5'-9" 6'-1" 8'-3" 6'-1" Freezer Entrance Stall

Use a minimum loading pad 6' curb length of a hard surface to connecting curb and sidewalk.

SECTION DOOR HARDWARE

THE HEMLOCK 3 BD 2.5 BA 1371 sq ft

Sprinkler: The building does not have a fire protection system installed. MECHANICAL / PLUMBING / SPRINKLER SYSTEMS RECOMMENDATIONS

HOLUM EDUCATION CENTER. Architectural. January 13, 2014 DeForest Area School District

Procurement Department ADDENDUM # 1

Introducing... The Lake Country Series. 18 Wide Single Section Homes. ... our WIDEST single section homes! Canada. Proudly made in

Safe at Home. Suggestions for Homeowner Created in partnership with the Administration on Aging. Assessor: Assessor: Homeowner Name: Address:

SECTION DOOR HARDWARE

Landscape Includes sprinkler system Irrigation, system maintenance, and landscape upkeep are all included in H.O.A. dues

About This Model. Series: Blue Ridge MAX Model: B Grandview Max. Style: Ranch / Bedrooms: 3 / Bathrooms: 2 / Square Feet: 1638.

Facilities Management State-Funded and Billable Services

Modern Exteriors Stylish Kitchens Designer Bathrooms Comtemporary Living Fixtures & Finishes Schedule Inclusions Brochure

room data sheet CORDOVA RESIDENCE 1/11 54 EAST CORDOVA STREET, VANCOUVER, BC RESIDENTIAL ROOM RM DIVISION ELEMENT REQUIREMENT

PLATTEVILLE MIDDLE SCHOOL

This Report Was Prepared For: Property Address Inspected:

Axiom Property Inspections

DESIGNER KITCHEN WITH PREMIUM APPLIANCES 1407 & 1409 Military Trail Features & Finishes 1. Open concept kitchen with NEFF designer cabinetry and Caesa

Inspection Report. 1 Inspection Way Orlando, FL Prepared for: Wanda Figueroa Prepared by: ACF Home Inspections Inc

room data sheet TAMURA HOUSE 396 POWELL STREET, VANCOUVER, BC 1/8 RESIDENTIAL ROOM RM DIVISION ELEMENT REQUIREMENT

1. Items known commercially as finish hardware or builders hardware, required for swing, sliding, or folding doors.

Caywood Builders Standard Selections

About This Model. Series: Richland ELITE Ranch Model: GF903A. Style: Ranch / Bedrooms: 3 / Bathrooms: 2 / Square Feet: 1813.

ONONDAGA COMMUNITY COLLEGE FERRANTE HALL RENOVATIONS - PHASE

The Lake Country Series


DIVISION 08 OPENINGS HARDWARE AND KEYING PART 1 - GENERAL 1.01 SUMMARY

Northpointe Renovation EPN #1701 F/A Project #17027 September 8, 2017

Celebrating 75 years of Schult excellence.

DIVISION 08 OPENINGS HARDWARE AND KEYING PART 1 - GENERAL 1.01 SUMMARY

The Lake Country Series

Springpoint Architects, pc SECTION Childcare Center Architect s Project No TABLE OF CONTENTS Monroe County Comm. Sch. Corp.

Element C Interiors Interior Construction

Stairway Location for Optional Foundation Model

General Kitchen, Bath & Bedroom Remodeling Notes County of Marin, Building Inspection Division

1152 Vinetta - Des Peres The Wakefield Model $634,900

About This Model. Series: Timberland Ranch Model: TL815A. Style: Ranch / Bedrooms: 3 / Bathrooms: 2 / Square Feet: Notes:


Columbia Single Section Homes

Proudly made in. Canada. to Canadian Standards. The Columbia Series. 14 Wide Single Section Homes

Appendix B. Facilities Assessment Report

CORRALES INTERNATIONAL SCHOOL TENANT IMPROVEMENT 5500 WILSHIRE AVE NE ALBUQUERQUE, NM 87113


About This Model. Series: Summit Model: RAE112A Barnsley. Style: Ranch / Bedrooms: 3 / Bathrooms: 2 / Square Feet: Notes:

22-F fire exit rim device for all types of 4 x 8 (1219mm x 2438mm) single doors and 8 x 8 (2438mm

room data sheet MARR HOTEL 401 POWELL STREET, VANCOUVER, BC 1/9 RESIDENTIAL ROOM RM DIVISION ELEMENT REQUIREMENT

Proudly made in Canada. to Canadian Standards

STC 46 3-Sided Paired Frame (Double Rabbet Only)

About This Model. Series: Richland ELITE Ranch Model: GF900A. Style: Ranch / Bedrooms: 3 / Bathrooms: 2 / Square Feet: 1493.

Closing Checklist. Mstr Hall/Clo. Mstr Bath. Guest Bath 1/2 Bath Kitchen Nook. Guest Hall. Utility Rm Garage Yard. Right Side Left Side Rear

PRESIDENTIAL SERIES 1

The Lake Country Series 16 Wide Single Section Homes

1225 TUNNEL ROAD PERKASIE BOROUGH, BUCKS COUNTY, PA

Agustin Lara Elementary Academy

THE ELEMENTS Updated as of 1/30/2019

HMC ARCHITECTS 2495 Natomas Park Drive, Studio 100 Sacramento, California ADDENDUM NO. 3

Ph: (907) Quality Homes

About This Model. Series: Richland Elite Modulars Model: GCM101A. Style: Cape / Bedrooms: 2 / Bathrooms: 2 / Square Feet: 1280.

Proudly made in. Canada. to Canadian Standards. The Columbia Series. 14 Wide Single Section Homes

About This Model. Series: Pennwest 2-Story Modular Model: HS125A Millington. Style: 2-Story / Bedrooms: 4 / Bathrooms: 3 / Square Feet: 2406.

CENTRAL GREAT PLAINS SERIES

Feb H: FINISH HARDWARE

room data sheet MARBLE ARCH HOTEL 518 RICHARDS STREET, VANCOUVER, BC 1/14 RESIDENTIAL ROOM RM DIVISION ELEMENT REQUIREMENT

Proudly made in. Canada. to Canadian Standards. The CJ Series. 20 Wide Homes

DOOR HARDWARE SECTION DESIGN REQUIREMENTS GENERAL INFORMATION

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 10 - SPECIALTIES

JAMES P. KISSANE, ARCHITECT


1. Portable fire extinguishers. 2. Fire-protection cabinets for portable fire extinguishers.

YORK COUNTY DEPARTMENT OF FIRE SAFETY BUILDING PLAN REVIEW REQUIREMENTS

Homes. A Grandeur Manufactured home combines comfortable living with an affordable price. This type of home is placed on a

Transcription:

Description: 1. Floor: 2. Walls: 3. Ceiling: A. Finished and sealed 4 thick concrete slab on 10 mil poly vapor barrier on 4 of crushed stone throughout, including toilets. A. Interior gypsum board walls to receive tape and joint compound only and shall be sanded and ready to prime and paint. B. No thermal or sound insulation will be installed in any interior walls. Exterior walls will be insulated to a value of R-11. C. No base trim will be installed. A. Tile to be 2 x4 x5/8 lay in as manufactured by Armstrong or approved equal. B. Tile pattern to be No. 755 white fissured 24 x 48 minaboard or approved equal. C. Ceiling suspension system is standard 15/16 prefinished (white). D. Height of ceiling to be approximately 10-0. A ceiling height greater than 10-0 must be planned for in advance. Toilet rooms to have 8-0 ceiling height. 4. Windows and Doors: A. Windows will be 1 insulated clear glass, tempered where required by code.

B. Window frames will be aluminum store front type with dark bronze anodized finish. C. No window treatments will be provided. D. Front doors shall be narrow stile aluminum store front type with dark bronze anodized finish. E. Front door hardware to be as follows: Pair of offset pivots Threshold Weather striping Push/Pull for each door leaf Door closer for each door leaf Thumb turn lock Flush bolts for inactive door of pairs Key cylinder

F. Rear door and frame will be of the hollow metal type and will be factory primed only. G. Rear door hardware to be as follows: 1½ pair of butt hinges with non-removable security studs Lockset Door closer Weather striping Threshold Latch guard H. Toilet room doors will be solid core wood (birch veneer) with hollow metal frame and not finished. I. Toilet room doors to be furnished with a privacy latch set, 1½ pair butt hinges.

5. Toilet Accessories: A. Two handicapped grab bars will be provided per toilet room. One 36 grab bar (Stock No. Bobrick B6206 x 36 or approved equal) will be mounted on wall at back of toilet. One 42 grab bar (Stock No. Bobrick B6206x42 or approved equal) will be mounted at the side of the toilet. B. A frameless float plate glass 24 x 36 mirror will be provided above sink. C. A Bobrick toilet paper dispenser (Stock No. B685) will be provided. 6. Mechanical and Plumbing A. Heating, cooling and ventilation will be provided at a rate of 350 s.f. per ton. B. No special heating or cooling requirements have been taken into consideration (i.e. restaurants, dry cleaners, tanning shops). C. HVAC units will be equipped with an electronic thermostat. D. HVAC unit(s) will not be equipped with an economizer. E. HVAC units (condensers) will be ground mounted behind buildings. F. Ventilation in Toilet Rooms will be provided by a light/vent that is ducted to outdoors thru sidewall. G. Plumbing fixtures are limited to a flush tank water closet (American Standard or approved equal) and a wall mounted lavatory (American Standard or approved equal) per each Toilet Room. H. Lavatories will have a Delta single lever control.

I. Cold and hot running water will be provided at each lavatory (10 gallon water heater). J. A hose bibb to be shared with other tenants will be provided somewhere on the front of building. K. Each tenant space will be provided with a water meter. L. Fire protection sprinklers will be provided only when required by Code. M. House meter for hose bibb and irrigation. 7. Electrical Service, Lighting, Electrical Fixtures and wiring: A. Electrical service including meter socket is provided at rear of store. B. Electrical service provided is 120/208-volts, three phase. C. Size of electrical service is based on the size of the tenant space and average retail usage. No unusual power requirements have been taken into consideration (i.e. restaurants, dry cleaners, tanning shops) D. Each tenant space will have at least one (1) 200 amp panel. E. All necessary wiring for the power and control to the HVAC system will be installed in each tenant space. F. Exterior lighting at the front of the building will consist of decorative wall lighting. Number and location of these fixtures to be determined by electrical engineer. G. The above mentioned front and rear exterior lighting will be controlled by a photo cell and timeclock on a separate house panel. H. One (1) 2 telephone conduit will be provided, originating from a centrally located panel and will be run to each tenant space.

I. A 48 x 48 ¾" plywood telephone terminal mounting board will be provided in each tenant space. J. Electrical service will be sized to accommodate a ten (10) gallon water heater, which the Owner will provide. K. Electrical service will be sized to accommodate basic exterior signage, wiring to signage, conduit for wiring to signage or photo cell and timeclock to control signage. L. 2 x 4 fluorescent lighting fixtures will be installed at a rate of approximately one (1) per one hundred (100) square feet. 2 x 4 fluorescent fixtures will have acrylic lens. M. Lighting in Toilets to consist of ceiling mounted light/vent fan. N. Exit signs and battery pack units internal to 2 x 4 lighting fixtures will be installed for egress and emergency lighting. O. Duplex plug receptacles will be provided at approximately 20 on center on perimeter walls. P. Toilet rooms will have one (1) GFI electrical outlet. 8. Miscellaneous A. A bracket mounted 10# ABC fire extinguisher will be provided for each tenant space by the tenant, to be located as directed by the Fire Marshal.