Explosion Proof Hazardous Location Roof Top A/C Units

Similar documents
RTXP2 Series - Division 1 OR 2 / Zone 0, 1,OR 2

VAC1 Series - Division 2 / Zone 2

VAC1 Series-Division 2 / Zone 2

VACPB1 Series - 60 Hz Models

Capacity: 1.5 to 6.0 Ton

Capacity: 1.5 to 6.0 Ton

CU-MS & AH-HW Mini-Split Series

Manufacturers of Explosion Proof, Corrosion Resistant and Severe Duty HVAC/R Systems, and Pressurization Equipment.

FX5 Series Explosion-Proof Electric Air Heaters

XGB Unit Heater. Certification. Model Coding XGB 038 T3B 3 1 T TEMPERATURE CODE T3B (165 C) T3A (180 C) T2D (215 C) T2C (230 C)

Explosion-Proof Forced Air Unit Heater - XGB

Explosion-Proof Forced Air Unit Heater - XGB

Stars Management JLT SUBMITTAL. EXPLOSION PROOF ELECTRIC AIR HEATER (FX Series)

Commercial High-Efficiency Condensing Units

CF1 ProVector Explosion-Proof Heaters

48TF GAS HEATING/ ELECTRIC COOLING UNITS

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

CX1 ProVector Explosion-Proof Heaters

Comfort. Description. Applications

48TM GAS HEATING/ELECTRIC COOLING UNITS

CB18/CBS18 Bulletin # September 1994 Supersedes August 1986

Concealed Ducted Split Series R-407C MBH

PAJ3. Product Specifications

Description. Applications

CWA4 Chilled & Hot Water Fan Coil

13 GEP A L P - 1 A

50TM TFF COMBINATION HEATING/COOLING UNITS

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

50TM COMBINATION HEATING/COOLING UNITS

WIBR SERIES. Unit Coolers - Technical Catalog Hunt St - Pryor, OK Fax

48SS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

Self-Contained & Split System Reverse Cycle Air Conditioners Models

EVLPF Series Compact Fluorescent

B24/C22/24 COILS BLOWER COIL UNITS ENGINEERING DATA. Bulletin # June 1994 Supersedes August B24 Blower Unit (With Optional Electric Heat)

Self-Contained & Split System Reverse Cycle Air Conditioners Models

Self-Contained Reverse Cycle Air Conditioners

R4H4. Product Specifications

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

RGE 13 A T - 1 A

Self-Contained & Split System Reverse Cycle Air Conditioners SAB Self-Contained Units, CAB Condensers and DEAH Air Handlers

A Series T 3. Unit Coolers - Technical Catalog. Product Benefits: Comdustrial TM Refrigeration. Adaptability- Durability- Serviceability-

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

Portable Vertical Air-Conditioning and Heating Systems

Burner Comparisons. Typical Competitor s Burner

KIC Air Curtains. Technical Guide

TECHNICAL GUIDE MODELS: MV MODULAR VARIABLE SPEED AIR HANDLERS FOR USE WITH SPLIT SYSTEM COOLING & HEAT PUMP DESCRIPTION FEATURES

SECTION (15767) - UNIT HEATERS

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

GAS-FIRED PRESSURIZED LOW INTENSITY INFRARED HEATERS SERIES TLP

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS

Description. Applications

Center Mount Unit Coolers

Explosion Proof LED Light - Equivalent to Watt Metal Halide - Class 1 Division 2

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

Today s Value-Added Performers. The DRY-30 Series Dehumidifiers from DryAire Systems.

CWA2 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000-60,000 BTUH

Product Data PH13(N,P)R FEATURES AND BENEFITS. SPLIT SYSTEM HEAT PUMP For Use With R Refrigerant 1---1/2 TO 5 TONS ( )

Today s Value-Added Performers. The DRY-40A Series Dehumidifiers from DryAire Systems.

SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS

Super-Flo Low Profile Unit Cooler

WCH5**4. Product Specifications

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

Installation Instructions

MH1WC4W-06-1-B Chilled/Hot Water 1-Way Cassette Fan Coil

NH 3. Dual Discharge Evaporator. Ammonia Industrial Applications 1-16 Tons MDAN

Q-TEC QC-Series Chilled Water Air Conditioner

R4H4. Product Specifications

General Description. Operation

Weathermaster Series 48HJ004, 005, 006, 007, 008, 009, 012 & 014 COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

Thru-The-Wall THDC Series R-410A Condensing Units Ton Series

TECHNICAL SPECIFICATIONS

SpaceKeeper Console (SKC)

Technical Guide DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS. 7-1/2 and 10 NOMINAL TONS LA090 & LA120 SUPPLY AIR PLENUMS

MHWW-24-H-1 Chilled/Hot Water Hi-Wall Fan Coil 2-Pipe Heat / Cool Fan Coil 24,000 BTUH

MHWW-09-H-1 Chilled/Hot Water Hi-Wall Fan Coil 2-Pipe Heat / Cool Fan Coil 9,000 BTUH

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

DRY CHARGE UNITS. 1.5 to 5 Tons AIR CONDITIONERS LCS13DC PRODUCT SPECIFICATIONS L C S 13 DC MODEL NUMBER IDENTIFICATION

PA 500/1100V Ultra Quiet Ventilation Fan

Product Data. GEMINI SELECT 09DPS ,09DPM Air-Cooled Condensers with PURON Refrigerant (R-410A) 50/60 Hz

072, 090, 120, 180 & 240 MODELS C SERIES CONDENSING UNITS P SERIES HEAT PUMPS

MODELS B1PA024, 030 AND 036

XB Convection Heater. Convection Heaters. Applications. Special Wattage and Lengths. Selection of Temperature Code. Construction and Installation

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT

Q-Tec TM QC-Series Chilled Water Air Conditioner

Indoor Air Handlers with Compressors MVS and MVW

Installation Instructions

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

T P A 120 S 4 S N 1 Y

16 SEER TWO-STAGE AIR CONDITIONERS

MERIT SERIES Up Flow / Horizontal

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Mission Critical. Series 6, 8 & 9. vertical floor mount Ton Units. Air Conditioning Systems

Convection Heaters. Type XB. Product Description. Selection of Temperature Code. Construction and Installation. Special Wattage and Lengths

TZPL SERIES. Applications Thermal Zone remote heat pumps offer comfort and dependability for single, multi-family and light commercial applications.

CENTRAL SPLIT UNIT UNIC

Corporation , Soraji-ro, Paju-si, Gyeonggi-do, Republic of Korea (Postal Code: 10863)

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

Transcription:

Explosion Proof Hazardous Location Roof Top A/C Units RT-XPC Series RT-XPC Series Roof Top Air Conditioning Systems are designed to Provide Maximum Indoor Comfort while meeting the demanding requirement of Severe Duty Industrial Applications. The RT-XPC Series system can be built to meet Division 2 and/or Zone 2 in the: Condenser Section Only, Evaporator Section only, or both Condenser and Evaporator Section. Our Systems are Fully Tested for Operational Performance and Compliance. Units are Manufactured to N.E.C. and I.E.C. Explosion Proof Codes as well as CSA Certified RT-XPC Series Division II and Zone II Applications 13500 & 15000 BTU/HR Capacity 60 & 50 Hertz Models Standard Features All Electrical Components are UL Approved Explosion Proof Overload Protection on Motors and Compressors Easily Accessible Motor for fast and Convenient Service Non Sparking Condenser Fan and Blower designs Aluminum Fin and Copper Tube Coils for Maximum Heat Transfer Explosion Proof and General Purpose Operational Controls Ceiling Assembly Included with Air Filter Operation, Maintenance & Installation Manuals Included System Third Party Certified for use in Hazardous Locations by CSA International N.E.C. Rated and Approved Safe Air Technology Offering The Keys to Success: Quality, Pricing and On Time Delivery 4133 Evan Brooks Road Baton Rouge LA 70814 U.S.A Phone (225) 303-0007 Fax (225) 303-0020 www.explosionproof.net Email: sales@explosionproof.net COPYRIGHT 2014 Safe Air Technology LLC. All Rights Reserved 1 R1-0405

System Description Safe Air Technology RT-XPC series Units are fully tested for operational performance and compliance to ensure customer satisfaction. Our units are designed to provide cooling for Industrial severe duty applications. Our quality of engineering and manufacturing will ensure many years of reliable service. Please contact our sales engineering departments should you have any questions. We look forward to working with you and serving your needs for all of your HVAC/R Projects. Safe Air Technology, providing NEC Certificates of Conformance showing compliance with N.E.C. codes. If requested, SAT will provide an engineering submittal package for approval prior to manufacturing. System Applications Industrial Refineries Chemical Plants Offshore Platforms Gas Plants and Pipelines Corrosive and Hazardous Storage Facilities Ammunition Storage Bunkers Paint Rooms Fuel Transfer Docks and Pumping Stations Available Options -B -CC -CRT -EPX -MG1 -MG2 -SH4 -SH6 -SVI Group B Classification Copper Tube and Copper Fin Coils Export Crate for Sea or Air Shipping Epoxy Coated Metal (50HZ Units Only) Marine Grade Coating Condenser & Evaporator Coated Marine Grade Coating Coils & Sheet Metal Coated 304 Stainless Steel Housing 316 Stainless Steel Housing Service Port Installed Bottom Section Return Air Filter Installed This photo shows the controls for the unit when the blower and interior section must comply with Explosion Proof Codes. The bottom section is still put into place, but without the standard general purpose controls. This photo shows the standard bottom section for a General purpose blower section. Note that standard Controls remain. 2

RT-XPC Series [ 60 Hz. ] Class I, Groups C & D, Division 2 T-3 Model (1) 60 Hertz BTU/HR Power Supply Volts / Ph / Hz. Heating Wire Size (2) Fuse Size (3) Air Flow CFM RT-XPC-13500-1-N-CND-ICD2-*** 13,500 115 / 1 / 60 15.5 N/A 12 20 320 RT-XPC-13500-1-EH-CND-ICD2-*** 13,500 115 / 1 / 60 15.5 16 12 20 320 RT-XPC-13500-1-N-AU-ICD2-*** 13,500 115 / 1 / 60 15.5 N/A 12 20 320 RT-XPC-15000-1-N-CND-ICD2-*** 15,000 115 / 1 / 60 15.9 N/A 12 20 320 RT-XPC-15000-1-EH-CND-ICD2-*** 15,000 115 / 1 / 60 15.9 16 12 20 320 RT-XPC-15000-1-N-AU-ICD2-*** 15,000 115 / 1 / 60 15.9 N/A 12 20 320 RT-XPC Series [ 50 Hz. ] Class I, Groups C & D, Division 2 T-3 Model (1) 60 Hertz BTU/HR Power Supply Volts / Ph / Hz. Heating Wire Size (2) Fuse Size (3) Air Flow CFM RT-XPC-13500-2(50)-N-CND-ICD2-*** 13,500 220-240 / 1 / 50 7.4 N/A 12 15 300 RT-XPC-13500-2(50)-EH-CND-ICD2-*** 13,500 220-240 / 1 / 50 7.4 9 12 15 300 RT-XPC-13500-2(50)-N-AU-ICD2-*** 13,500 220-240 / 1 / 50 7.4 N/A 12 15 300 Notes: See Nomenclature for Unit ID ( 2 ) THHN 75 C Copper Wire ( 3 ) Delay Fuse or Approved Circuit Breaker ( *** ) Options that can be added. Contact our Sales Department should your specifications require a variation on our standard units. IMPORTANT NOTICE T Codes: It is important to know the auto ignition temperature of the Gas or Vapor the unit will be operating in or around. The Gas or Vapor temperature should be above the rating of the equipment. 3

System Dimensions Shipping Weights and Dimensions STANDARD PACKAGING SINGLE AND DOUBLE EXPORT CRATE Standard Packaging Data Single Crate Data Double Crate Data Length Width Height Weight Length Width Height Weight Length Width Height Weight 36 46 26 175 LBS 36 46 30 275LBS 36 46 60 550 LBS 4

RT-XPC - 13500-1 - N - CND- ICD2 - *** Roof Top Identification RT-XPC = Roof Top Capacity 13,500 = 13,500 BTU/HR 15,000 = 15,000 BTU/HR Unit Power Supply Options 1 = 110-120 Volt / 1 Phase / 60 Hertz 2(50) = 220-240 Volt / 1 Phase / 50 Hertz Heating Options EH = Electric Heat N = No Heat Area of Explosion Proofing for N.E.C. Classification CND = Explosion Proofing ONLY to Condenser Section AU = Explosion Proofing to All Sections of Unit Explosion Proof N.E.C. Classification Contact Our Sales Engineering Department for Classification Codes ICD2 = Class I, Groups C & D, Division 2 IBCD2 = Class I, Groups B, C & D, Division 2 Options Listed at End of Model Number - B = Group B Classification (B) - CC = Copper/Copper Coils Installed (CC) -CRT = Export Crate Included (CRT) -EPX = Epoxy Coated Metal (50HZ Units Only) (EPX) -MG1 = Marine Grade Coating Condenser & Evaporator Coated (MG1) -MG2 = Marine Grade Coating Coils & Sheet Metal Coated (MG2) -SH4 = 304 Stainless Steel Housing (SH4) -SH6 = 316 Stainless Steel Housing (SH6) -SVI = Service Port Installed (SVI) 5