SUBJECT Model ASH218SV-C8LU SPECIFICATION ASH218SV-C8LU. 1. SCOPE This specification is applied to SHANGHAI HITACHI rotary compressor.

Similar documents
HITACHI ROTARY COMPRESSOR MODEL SG153BG3GC I. SPECIFICATION. This specification is applied to SHANGHAI HITACHI rotary compressor. 2.

COMPRESSOR SPECIFICATIONS

Rotary Air-conditioning Compressors Specification

M P 1 2 F G C O M P R E S S O R TECHNICAL SPECIFICATIO N

CK C O M P R E S S O R

NE6210CZ NE6210CZ C O M P R E S S O R TECHNICAL SPECIFICATION HUANGSHI DONPER ELECTRICAL APPLIANCE CO., LTD

.2 Section Waste Management and Disposal.

CJ6240CK COMPRESSOR TECHNICAL SPECIFICATION HUANGSHI DONPER ELECTRICAL APPLIANCE CO., LTD

APPROVAL SHEET SPECIFICATIONS OF HERMETIC SCROLL COMPRESSOR C-SBR180H16A

TECHNICAL DATA & SERVICE MANUAL

Contour TM Screw Compressors

PROAIR Air Conditioner. CR23 Model INSTRUCTION MANUAL nvent Rev. D P/N

PROAIR Air Conditioner. CR43 Model INSTRUCTION MANUAL nvent Rev. H P/N

SECTION ROTARY-SCREW WATER CHILLERS

PROAIR Air Conditioner. CR29 Model INSTRUCTION MANUAL nvent Rev. I P/N

T-SERIES Air Conditioner. T29 Model INSTRUCTION MANUAL nvent Rev. I P/N

T-Series Air Conditioner T53 Model

Technical Manual for LG Compressor

EBAC MODEL WM150 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

TECHNICAL DATA & SERVICE MANUAL

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

T-SERIES Air Conditioner. T50 Model INSTRUCTION MANUAL nvent Rev. F P/N

T-SERIES Air Conditioner. T43 Model INSTRUCTION MANUAL nvent Rev. I P/N

1. TF Hermetic Reciprocating Compressor

GENESIS Air Conditioners. All Models INSTRUCTION MANUAL nvent Rev. K P/N

T-Series Air Conditioner T15 Model

Featuring Ozone-safe HFC134a. Hitachi Centrifugal Chillers NEW. GXG-S Series GSG-S Series. Debut

Rev. E 2013 Pentair Technical Products P/N Distributed by: McLean Parts

T-Series Air Conditioner T20 Model

Refrigeration & Air Conditioning Experiment No. 5. Experiment No. 5

Instruction Manual. Refrigerated Air Dryer

TOSHIBA AIR CONDITIONING

Condensing Units CUS 15-60

PARALLEL RACK SYSTEM INSTALLATION & OPERATIONS MANUAL With Master Rack Compressor Sequencer

V-SERIES Air Conditioner. VA08 Model INSTRUCTION MANUAL nvent Rev. F P/N

SERVICE Manual AIR CONDITIONER AW0719 AW Precautions. 2. Product Specifications. 3. Operating Instructions and Installation

ORTEC HIGH CAPACITY REFRIGERATED AIR/GAS DRYERS

SAVE THESE INSTRUCTIONS HOUSEHOLD USE ONLY

NM1850 SERVICE PARTS

SPECTRACOOL Air Conditioner. N21 Model INSTRUCTION MANUAL nvent Rev. G P/N

Service Manual & Installation Manual

INSTALLATION AND COMMISSIONING MANUAL. Neos 100S Integra 20X, 30S, 35X, 40X, 50X

DTW Works Master Specification Version 2006 Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5

Room Air Conditioner Service and Parts Manual

INVERTER WALL MOUNTED TYPE ROOM AIR-CONDITIONER (Split system, air to air heat pump type)

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

LABORATORY AIR COMPRESSORS AND VACUUM PUMPING SYSTEMS

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

CS/CD/CP AIR COOLED CONDENSING UNITS (P/N E207120C R2)

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models

Danfoss Scroll for Refrigeration MLM / MLZ

PACKAGE AIR CONDITIONER

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

A/C-HEATER SYSTEM - MANUAL

Centrifugal Chiller. GFG-S/SIT Series GXG-S/SIT Series GSG-S/SIT Series

HVAC Basics RESIDENTIAL AIR CONDITIONING

T-SERIES Air Conditioner. T20 Model INSTRUCTION MANUAL nvent Rev. C P/N

PC20-AMFII / PC40-AMF USER MANUAL

NUMBER: ISSUED: JULY 13, /336 73/23 STACKABLE CRESCENT CUBER KM-1300SWH-E SERVICE MANUAL FOR QUALIFIED SERVICE PERSON HOSHIZAKI

RPI Industries, Inc.

Hoshizaki America, Inc.

TECHNICAL DATA & SERVICE MANUAL

VA G 052 S VA08 Indoor Model 1200, 1500 and 2000 Watts. Sealed Enclosure Cooling Air Conditioners

RM85 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

MACH N-407 Heat Pump Air-Cooled Chiller

Publication # RD-0003-E Rev 1, 10/17 SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS

R4H4. Product Specifications

SERVICING PROCEDURE R-410A LEAK TEST EVACUATION CHARGING. Bard Manufacturing Company, Inc. Bryan, Ohio Manual Page 1 of 11

NM952 SERVICE PARTS TABLE OF CONTENTS. Cabinet Air Cooled Refrigeration Water Cooled Refrigeration Water System Gearmotor...

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624. Models HFC. Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624.

Installation, Operation, and Maintenance Information

TECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER

Air Conditioning Operation and Troubleshooting Matt Dunham

Código : Motc.PANASC/SANYO-CSB453H8A--6HP-15100fr

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER OUTDOOR UNIT: AE22AC/ACL/AH AE28AC/ACL/AH AE38AC/ACL/AH AE42AC/ACL/AH

SERVICE MANUAL PORTABLE AIR CONDITIONER WAP-237EB NEW WIDETECH V 50Hz

ON/OFF. Domestic Air conditioner. Wall mounted Type Arc-Series CAUTION HSU-14HR03/R2 HSU-18HR03/R2 1. READ THIS MANUAL CAREFULLY TO

UCV CONDENSING UNITS SPECIFICATIONS 1. Specifications

Commercial High-Efficiency Condensing Units

Air-Cooled Condensing Units with Compact Screw Compressors

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624 REVISED EDITION-E. Models HFC

User s Information and Installation Instructions

HNC-120BE-L/R-B HNC-150BE-L/R-B HNC-180BE-L/R-B HNC-210BE-L/R-B COUNTER SHOWCASE MODEL SERVICE MANUAL HOSHIZAKI

COMPRESSOR TECHNICAL OVERVIEW

POLICY BULLETIN Tecumseh Compressor Company Compressor Group

EBAC MODEL K100 DEHUMIDIFIER OWNER S MANUAL

GTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts

MOBILE AIR CONDITIONER. User Manual PC15/20/26-BCB

(PD[ $LU 'U\HU 5 ( ) 5, * ( 5 $ 7 ( ' 7 < 3 ( & ( 6 6 ( ' $, 5 ' 5 < ( 5 6 ('5&) ದ ('5&) Instructions Manual

Operation Manual and Parts Directory

Service Step by Step Trouble-Shooting Check-List

HOSHIZAKI MODULAR CRESCENT CUBER MODEL KM-280MAH KM-280MWH SERVICE MANUAL

0.4 In the preparation of this standard, assistance has been derived from the following standards:

MAC N-407 Air-Cooled Chiller

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

Chapter 6. Do s & Don ts in Refrigeration & Air-Conditioning Servicing

T P A 120 S 4 S N 1 Y

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

Transcription:

ASH218SV-C8LU

SUBJECT Model ASH218SV-C8LU SPECIFICATION ASH218SV-C8LU PAGE:1/23 1. SCOPE This specification is applied to SHANGHAI HITACHI rotary compressor. 2. SPECIFICATION OF COMPRESSOR 2.1 Model ASH218SV-C8LU 2.2 Rated Voltage-Frequency-Phase 220~240V/50Hz 2.3 Application Air Conditioning 2.4 Refrigerant R 410A 2.5 Compressor Cooling Forced air 2.6 Displacement 2.7 Rated capacity(see*) 2.8 Motor input(see*) 21.83ml/rev 5180W(4455Kcal/h) (220V) 1785W (220V) 2.9 COP 2.90 COP= Rated capacit (W) (220V) Motor input (W) 2.10 Current 8.25 A (220V) 2.11 Allowable amount of refrigerant charge 2100g 2.12 Amount of oil charge 600±20 ml(initial) 2.13 Oil HAF68D1 or equivalent 2.14 Space volume of inner case 1850ml 2.15 Net weight 19.5 kg incl.oil

SUBJECT Model ASH218SV-C8LU SPECIFICATION PAGE:2/23 2.16 Hermetic Terminal 1/4 quick connect type 2.17 Motor Type Permanent Split Capacitor Capacitor 60μF /400 Volts Locked rotor amps 40A (240V/50Hz) Approved voltage range Rated voltage ±10% Winding resistance(m/s) 2.06/1.87Ω(at 75 ) 2.18 Rated conditions Voltage 220 V Evaporating temp. 7.2 Condensing temp. 54.4 Liquid temp. entering expansion valve. 46.1 Return gas temp. 35 Ambient temp. 35.0 2.19 Starting performance (1) The starting voltage should be as follows. (2) The starting pressure should be balanced between the suction and discharge of the compressor and should be adjusted to the following table. (3) The temperatures of the compressor enclosure should be more than 20 continuously at the following table.

SUBJECT Model ASH218SV-C8LU SPECIFICATION PAGE:3/23 Starting Conditions TABLE 1 Spec Motor temperature Pressure Starting voltage MPa{kgf/cm 2 G} Cold-Starting Cold state (room temperature) 1.703{16.36} (V 2 )** Below 85% of rated voltage Hot-Starting(Standard) Hot state after operated under standard load condition 1.703{16.36} Below 85% of rated voltage Hot-starting(Overload) Hot state after operated under overload condition 1.860{17.96} Below 90% of rated voltage *. Rated capacity and motor input are measured by secondary Refrigerant calorimeter Methods of JIS B8606 by Shanghai Hitachi Electrical Appliances Co., Ltd. Allowable capacity should be more than 95% of the rated capacity and Allowable motor input should be less than 107% of rated motor input. **. V 2 means minimum voltage measured between pins of hermetic terminal at the compressor starts. V 2 Time ***. The suction pressure is measured on the position above the filter of accumulator.

SUBJECT Model ASH218SV-C8LU SPECIFICATION PAGE:4/23 3. PARTS AND DRAWING LIST PARTS NAME QTY/SET DRAWING NO. REMARKS Compressor Dimensioned sketch 1 4CYCH0002 Mounting RUBBER GROMMET 3 4CYC00008 parts Bolt - 4CYC00175 * Nut - (M8) * Electrical Oterminal-Cover 1 4CYC00101 parts Gasket 1 4CYC00102 Nut 1 3CYC00004 Rubber-Washer 1 4CYC00174 Running Capacitor - 4CYC00173 * 4CYC00737 Wiring Diagram Performance curve * Out of supply, for reference. 4. CHARACTERISTICS 4.1 Residual moisture 150mg MAX 4.2 Residual impurities 100mg MAX

ROTARY COMPRESSOR CRITERIA FOR LONG LIFE REFRIGERATION SYSTEM PAGE:5/23 1. SYSTEM DESIGN LIMITATIONS 1.1 Power source and Voltage Voltage applied to hermetic terminal should be within the range mentioned in this specification. In the case of three phase, the phase imbalance should be within 3% among the compressor terminals. The phase imbalance should be calculated according to the follow formula. (V)max-(V)mean the phase imbalance = 100% (V)mean (V)max:Maximum voltage among the three terminals. (V)mean:average voltage among the three terminals. 1.2 Operating Temperatures and Pressures The operating temperatures and pressures of the compressor should be within The range shown in the table 2. 1.3 Operating and Shut-off Period The compressor should be operated continuously at least for 5 minutes after Being turned ON.3 minutes shut-off time should be ensured at least until restarting. 1.4 Leak Test Pressure 4.32MPa[abs] 1.5 Oil Back and height of the oil level Oil should be returned continuously to the compressor and not kept in the refrigeration system. Oil level of compressor should be higher than 7.5 mm from the lubricating piece fixed on the end of the crankshaft.

ROTARY COMPRESSOR CRITERIA FOR LONG LIFE REFRIGERATION SYSTEM PAGE: 6/23 Item Table 2 表 2 Standard load condition *Overload Condition Blocked fan condition Discharge pressure 3.376{33.4} MAX MPa{kgf/cm 2 G} Suction Pressure 0.64~1.22 {5.5~11.4} MPa{kgf/cm 2 G} MAX Discharge pipe temperature **110 MAX 4.268{42.5} MAX 0.64~1.22 {5.5~11.4} MAX 5.0{50.0} MAX Compressor case bottom temp 99 or below and 6 degrees higher than condensing temperature Motor winding temp. Rated voltage: 99 MAX R.Voltage±10%: R.Voltage±7.5%: 127 MAX Motor winding temp. under locked-rotor condition Accumulator temp Ambient temp. 127 MAX under stable condition: OLR Average OFF 165 MAX Temp Highest Highest 190 MAX Average OLR ON Time Higher than outlet pipe of evaporator 35 43 Notes: * Overload condition should not be continuous. ** Discharge pipe temperature should be less than 110 at 300mm away from compressor surface. The end of thermocouple should be soldered on the discharge pipe surface, and the soldered place is covered by urethane foam insulation preventing the influence of air flow, when you measure the discharge pipe temperature.

ROTARY COMPRESSOR CRITERIA FOR LONG LIFE REFRIGERATION SYSTEM PAGE:7/23 Compressor must not be started operated under a dual-layer separate status. However, in case of foaming situation, the height of this foam does not mean the height of the oil level. If you do not keep the oil level, the oil shortage will occur, and influence the reliability of compressor. (Please check the oil level in the compressor with the sight glass we supply.) 1.6 Liquid refrigerant return limitations (1) Liquid refrigerant level in s-tank should be lower than the top of s-pipe in s-tank.(see chart at right) (2) There should not exist noise of the liquid refrigerant compression, current and vibrancy increase. System can append the assistant stank or reduce the amount of refrigerant to prevent from liquid refrigerant compression. Refrigerant system forbid liquid refrigerant from flowing back compressor in any case. In normal condition the overheat gas refrigerant should flow back compressor. 1.7 Allowable Incline The allowable incline should be less than 5 during operation. 1.8 Pipe Vibration The displacement of the pipes, which connect from the compressor to other Parts of the refrigerator systems, should be less than 0.8mm(1/32 )when the compressor is operating at rated frequency +10Hz/ -10Hz and voltage range of rated ±10%. Displacement in excess of 0.8mm(1/32 ) will require changing tube length and/or routing.

ROTARY COMPRESSOR CRITERIA FOR LONG LIFE REFRIGERATION SYSTEM PAGE:8/23 1.9 Connecting Tube Design In designing and routing tubing that connect from the compressor to the Other parts of the air conditioner, following should be considered. Moving tubes to the moving parts; minimum clearance 12.7mm(1/2 ) Moving tubes to non-moving parts; minimum clearance 9.5mm(3/8 ) Moving tubes never touch to lead wire. 2. PROCESS LIMITATIONS 2.1 The degree of vacuum in the refrigerating system should be less than 20Pa {150 10-3 mmhg}at room temperature just before charging refrigerant. The quantity of water should be less than 0.15ml. 2.2 Prevent moisture from entering into the enclosed unit system. When the moisture entered into the unit with refrigerant R410A, the refrigerant oil and the organic compound material presented in the hermetic motor will possibly decompose on the affecting of water. It will result in the capillary depositing and the reducing of insulation resistance. It is necessary to install a dryer to dehumidify the residual moisture mixed in the refrigerant in the cycling system. The specially defined molecular-sieve dryer is advised. 2.3 The weight of foreign particles on the inside surface of the heat exchanger tubes should be less than 0.01g/m 2. Metallic dust should not be permitted to enter the refrigerating system.

ROTARY COMPRESSOR CRITERIA FOR LONG LIFE REFRIGERATION SYSTEM This value means the weight of foreign particles filtered after washing inside surface of the heat exchanger tubes with R-11. PAGE:9/23 Prevent the impurities from entering into the enclosed unit system. When the impurities entered into the enclosed system, it will damage the moving mechanism parts and result in the capillary depositing. 2.4 Eliminate all system contaminants such as trichlorethylene, alkalies,soap,acid, oil & washing fluid used at machining the heat exchanger tubes. 2.5 The quantity and kind of contamination (the process materials) in the cycle should be grasped and managed. Carry on reliability test that input contamination a lot than anticipated contamination quantity. 2.6 Purge parts with dry nitrogen or dry air to remove remains in parts (dust, detergent,etc.)before assembly of system. Time for purging:over one second for pipe;over three seconds for heat exchanger. Purging pressure: 0.9±0.1MpaG.Dew point of dry air:below-20. Dry nitrogen should be charged in compressor before assembly of system. Welding should be finished within one minute after charge of nitrogen.dry nitrogen needs to be charged again and weld if over one minute. Always pruge the compressor with dry nitrogen during assembly of system. 2.7 The motor winding temperatures should be less than 149 in process of manufacturing the refrigerating system. The temperature of the hermetic terminal body should be less than 177.

ROTARY COMPRESSOR CRITERIA FOR LONG LIFE REFRIGERATION SYSTEM PAGE:10/23 2.8 The compressor should be operated for more than 20 seconds within 15 minutes after charging refrigerant Into the system so proper lubrication results. 3. MISCELLANY 3.1 The pipe and hermetic pins attached to the compressor should not be bent. 3.2 The compressor should never be operated while under vacuum;otherwise, internal arcing can cause damaging parts. 3.3 The compressor should not be operated to form a vacuum and to absorb air. 3.4 The compressor should not be left opened in the atmosphere for more than 5 minutes. When the air entered into the unit system with refrigerant R410A, it will expedite the deterioration Of the oil and result in the capillary depositing and the reducing of insulation resistance. 3.5 The electric pulse should not be applied to the hermetic terminals when the compressor is under vacuum. 3.6 The compressor should be kept in the clean place with low-moisture. 3.7 The compressor must not be applied for transportation equipment, such as automobiles, trains, ships, and others. 3.8 The compressor should not be splashed with water intentionally. 3.9 Use the refrigerant of specified brand. When the refrigerant not specified used, it will possibly cause trouble of the performance and reliability of the compressor by the impurities in the refrigerant.

ROTARY COMPRESSOR CRITERIA FOR LONG LIFE REFRIGERATION SYSTEM 3.10 Refrigerant should be charged from the end of condenser of refrigerating systems. Never charge refrigerant to the compressor directly. PAGE:11/23 The refrigerant should always be charged in liquid state. When the refrigerant is charged in gas state, The percent component will possibly be changed. Do not recharge with the remaining refrigerant in the System when leakage happened. Because the percent component of the refrigerant in the unit system had Possibly been changed. 3.11 Temperature s within systems during stable compressor operation should not be less than -35 to prevent wax precipitation from the oil. 3.12 Compressor mounting Rubber grommets are designed soft to provide the noise isolation and To lessen vibration energy Transmission. Stud bolt should be designed to provide sufficient clearance for noise and vibration isolation and to Prevent compressor from coming off its mount. 3.13 The compressor,if dropped, should not be used. 3.14 The first starting voltage supplied to the refrigerating system should be more than the starting voltage mentioned TABLE 1(page 3). 3.15 The trouble of refrigeration system components such as the reversing valve, solenoid valve, defrost mechanism, refrigerant control parts, fan motor, etc. may cause failure of the compressor. Reliability of those components should be checked. A design that insures no leakage during manufacturing and usage should be applied.

ROTARY COMPRESSOR CRITERIA FOR LONG LIFE REFRIGERATION SYSTEM PAGE:12/23 3.16 The compressor should be kept out of the corrosive atmosphere such as in a chemicals storage, beside a hot spring and so on. 3.17 The lead wires should be connected to hermetic terminals without being touched on the surface of the compressor. 3.18 The fuse or/and breaker should be equipped in the main circuit. 3.19 There should be adequate clearance between the OD26-under-surface of Bolt-head and the upper surface of rubber grommets. 3.20 To avoid water and impurity into the refrigeration system and make sure no leakage of refrigerant during the operating course. It s required to direct the erector and maintenance man of air-conditioner. 3.21 Compressor can be used when ambient temperature is higher than 10. Confirm the start-up of compressor if the temperature of compressor surface is below 10. Heat up compressor to reach the temperature higher than 10 with heater if the ambient temperature is below 10.

Check upon Delivery PAGE:13/23 1. Basis for Checking upon Delivery The Performance test will be carried out in accordance with this compressor Specification. The Safety Performance in accordance with GB4706.1 Safety of household and Similar electrical appliances General requirements and GB 4706.17 Safety Of household and similar electrical appliances Particular requirements for Motor-compressor. 2. Rule for Checking upon Delivery If come across any quality problem, please notify the company in written form Within 30 days after the arrival of the cargo, the company shall exchange Exactly the number of the products, otherwise they shall be regarded as being Up to standard.

14/23

15/23

16/23

17/23

18/23

19/23

20/23

0 21/23

22/23

23/23