NICHOLSON STEAM TRAP THERMODYNAMIC STEAM TRAPS

Similar documents
LIQUIDATOR UMT-TD Series Thermodynamic

THERMODYNAMIC STEAM TRAPS

THERMODYNAMIC STEAM TRAPS

THERMOSTATIC STEAM TRAPS

LIQUIDATOR 450 SERIES

CD-33/CD-33S Controlled Disc Steam Traps

FT600 & FT601* Steam Traps Float & Thermostatic Steam Trap. Float & Thermostatic STEAM TRAPS

Liquid Drainers LIQUID DRAINERS

PT15 MATERIAL : DIMENSIONS - Nominal in inches. AVAILABLE SPARES: Disc (Packet of 5) ORDERING INFORMATION: Refer to "HOW TO ORDER" page.

Technical Data CONDENSATE COMMANDER PUMP SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 9902D

Yarway Repairable Drip and Tracer Steam Traps Series 751/761, 711/721, 731/741, 500/546, 460/515/D3

UNIVERSAL STYLE STEAM TRAPS WU450 Series

Economical and simplified solutions that offer quality and optimum steam trap service.

YARWAY NON-REPAIRABLE DRIP AND TRACER STEAM TRAPS SERIES PB, 29, 129Y AND 29S

YARWAY PROCESS THERMODYNAMIC STEAM TRAPS SERIES 40/40D AND C250/260

THE THERMOSTATIC STEAM TRAP

Steam Traps and Steam Specialties

STEAM TRAPS

Pump & Trap Combinations

Condensate Pumps Jones Boulevard Limerick Airport Business Center Pottstown PA Tel:

The right trap for the right application.

Product. Add Efficiency To Your Steam Investment... Steam Traps Drain Traps Air Vents & Eliminators Accessories Piping Assemblies Replacement Kits

Pure Performance For Steam Mains and Tracers

Pamphlet A2404. Mechanical Pump & Pump/ Trap. GP Series GT Series

opening trap 30 mm Space required for Space required for opening trap 30 mm MK 45-1 with flanged ends (to DIN)

Hoffman Specialty General Catalog

Pure Performance For Steam Mains and Tracers

TABLE OF CONTENTS STEAM TRAPS INVERTED BUCKET SERIES PAGE FLOAT AND THERMOSTATIC SERIES PAGE THERMOSTATIC THERMODISC B0 26. How to Select All 107

THERMODYNAMIC STEAM TRAP

Wide range of steam traps that provide consistent performance in less than perfect conditions.

Float & Thermostatic Steam Traps for efficient condensate drainage of industrial process and HVAC equipment

Our Know-How. Your Peace of Mind. Steam Solutions

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD

Ball Float Steam Trap with Integral Spiratec Sensor and Flanged Connections

MODELS N150/300/675/900/1500/2500/2600 INSTALLATION, SERVICING AND MAINTENANCE INSTRUCTIONS

Hydrocarbon & Chemical Processing Solutions

FT14 and FT14HC. SG Iron Ball Float Steam Traps (1" HC, 1¼", 1½" and 2")

Pamphlet U2404. Mechanical Pump & Pump/ Trap. GP Series GT Series

STAINLESS STEEL TRAP VALVE STATION

Armstrong Steam System Solutions for the Hydrocarbon and Chemical Processing Industries

Series 151 and AV5. A wide range of process thermostatic steam traps is available to match almost any application need.

FT14 Ball Float Steam Trap (Screwed)

Armstrong Steam System Solutions for the Hydrocarbon and Chemical Processing Industries

Inverted Bucket Float & Thermostatic Radiator Traps STEAM CONTROL PRODUCTS STEAM TRAPS

Mini Pump Trap. Features: n Low maintenance - No leaking seals, impeller or motor problems reducing maintenance and downtime.

AIC Series Float & Thermostatic Steam Trap Installation and Maintenance Instructions

High Capacity Instantaneous Steam Fired Water Heater

Inverted Bucket Steam Traps. for efficient condensate drainage of industrial and HVAC equipment

Yarway Narvik Steam Desuperheater Series 4300 TempLow

Pamphlet M2404. Mechanical Pump & Pump/ Trap. GP Series GT Series

Armstrong J Series Float, Thermostatic Steam Traps, Condensate Controllers & Liquid Drainers Installation and Maintenance Manual

Installation and Maintenance Manual

YARWAY PROCESS THERMOSTATIC STEAM TRAPS SERIES 151 AND AV5

Steam and Condensate Technology. Solutions which are brilliant in their simplicity. combined with a first-class design & consultancy service.

Main Steam Vents. Hoffman Specialty Regulators. How to Select Steam Vents

INSTALLATION, OPERATION

S and SF Inverted Bucket Steam Traps Installation and Maintenance Instructions

Steam Traps. . Chambered valves such as; bleeding & venting valves and steam traps. Float Valves using a free fl oat

Ball Float Controlled. Thermo Dynamic(TD) Trap Safety Valve Condensate Pump Flash Vessel Moisture Separators Deaerator Head Steam Injector Sight Glass

Steam Trap Presentation for IDEA Distribution Workshop. Presenter: Joe Radle

GESTRA. Program for Universal Connections. The Smart Solutions

ESCO. Committed. Group of Companies. to help conserve Steam Energy

SECTION Pipeline Ancillaries

VENTS. Main Steam Vents. How to Select Steam Vents. For Steam Vent selection information, please refer to Selection Guidelines on page 133.

Pamphlet A2000. TL\l. Free Float Steam Trap Series

PRODUCTS. Expansion Joints Fire Fighting. Flexible Metal Hoses. Equipments. Insulation Solutions. Steam. Valves. Level Control.

STEAM CONSERVATION GUIDELINES

FLOAT AND THERMOSTATIC STEAM TRAPS FLT17 (DN 1/2 to 1 ; DN15 to DN25)

ø D ø g ø k Max. service [barg] pressure [psig] H 1 96 L BK 45 with butt-weld ends End connections Screwed Socket-weld

Steam trap checking WHY WE NEED TO CHECK STEAM TRAPS METHODS OF CHECKING TRAPS ADVANTAGES AND DISADVANTAGES PRACTICAL DEMONSTRATION

Bringing Energy Down to Earth

Section H11 BLOWDOWN SEPARATORS CONTENTS FEATURES AND BENEFITS...H11-3 PRODUCT OFFERING...H11-3 SAMPLE SPECIFICATIONS...H11-11 ILLUSTRATIONS

APPLICATION GUIDELINES STEAM MAIN DRAINAGE

MFP14 Automatic pumps. for condensate and other industrial fluids

Documento Descargado desde:

GEM TRAP FITTING & MAINTENANCE INSTRUCTIONS

D-11 OUTLINE SPECIFICATION FOR HTHW (ABOVE GRADE) HYDRONIC PIPING

Installation and Maintenance Manual Forbes Marshall Tracer Line Trap FMMST63

THE PRESSURIZED CONDENSATE RECOVERY SYSTEM:

Flow Control for Fire Protection

Air Vents AV-392. Proven Same proven, free-floating all stainless steel mechanism as used in Armstrong steam traps.

BASCO TYPE T and TC MOISTURE SEPARATORS and TRAP. ...world leaders in heat transfer technology

Steam Conservation Guidelines for Condensate Drainage Steam Trap Sizing and Selection.

Refrigerant Valves/Accessories

STEAM AND TRAP FUNDAMENTALS

PhiloWilke Partnership Addendum No. 2 A/E Project No April 2016

INSTRUCTION MANUAL. Keep this manual in a safe place for future reference TEMPERATURE CONTROL STEAM TRAP LEX3N-TZ LEX3N-TZ.

ICS Float and Thermostatic Steam Trap Installation and Operation Manual

Installation and Testing of Inverted Bucket Steam Traps Manual

High Pressure Water - Descale Valves - VXXX Series. Quad-S TM Poppet Cartridge Zero Leakage, Media Piloted Raw Water Operation

INDIRECT FIRED, SEMI-INSTANTANEOUS STEAM & BOILER WATER HEATER. Compact Design. High Recovery. Energy Efficient. Stainless Alloy Construction

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT

HEAT GENERATION 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS. B. Section HVAC Basic Materials and Methods

MFP14 Automatic pumps for condensate and other industrial fluids

Disc Type Steam Trap TSD-42

Thermostatic Steam Traps

Flanged Immersion Heaters

Boiler Steam Supply Piping Basics November 18, ) Q: What kind of condensate traps should be used on vacuum condensate return systems?

ECS Protector Nitrogen Generator. ECS Protector Nitrogen Generator PGEN-30. Specifications

How to Trap: Trap Selection and Safety Factors

Transcription:

THERMODYNAMIC S has a wide variety of Thermodynamic Steam Traps to accommodate applications through 600 psi. Most models utilize s exclusive Celtron Cartridge. The Celtron facilitates inline maintenance while simultaneously providing superior performance. The all-stainless NTD 600 is the value leader of the line, providing the performance users have come to expect in a conventional, recognizable design.

Applications Steam Tracing Drips Heating NTD 600 SERIES S Pressures To 600 PSIG (41.3 barg) Temperatures to 800 F (426 C) Compact Design Hardened stainless steel disc is the only moving part. Inexpensive Low initial cost is less expensive than repairable technologies. Simplifies Installation Works in any position. Rugged Handles water hammer and superheat. Reliable, Efficient Operation Blast discharge helps to eliminate dirt buildup and provides tight shutoff Freeze resistant Self draining design prevents freezing. All Stainless Steel Construction Resists both internal and external corrosion. Easy to Monitor Audible discharge cycle makes checking operation simple. Models NTD 600 Thermodynamic Disc Trap Operation Incoming air and condensate flow through the trap body and into the control chamber. Line pressure raises the disc off the seat allowing complete discharge. When flashing condensate enters the cartridge, flow velocity increases, creating low pressure underneath the disc. Flashing condensate at high velocity strikes the inside wall of the disc chamber and is deflected to the top of the disc causing a pressure buildup. The disc is forced down onto the seat by this pressure imbalance. The trap remains closed as flashed vapor in the control chamber keeps the disc seated. Pressure inside the cap is not lowered until the trapped flash vapor condenses due to body radiation. Condensing steam lowers the pressure above the disc. Disc is then lifted and the cycle repeated. C2

NTD 600 SERIES S Typical Specification Steam trap shall be of thermodynamic design. Body shall be of all stainless construction and hardened throughout. Seat shall be integral to body. Cover shall seal to body without gaskets or seals. Trap shall be suitable for pressures through 600 psi and available in 3/8" through 1". Maximum Operating Conditions PMO: Max. Operating Pressure 600 psig (41.3 barg) TMO: Max. Operating Temperature800 F (426 C) PMA: Max. Allowable Pressure 600 psig (41.3 barg) TMA: Max. Allowable Temperature 800 F (426 F) Materials of Construction Body: 420F SS ASTM A743 CA40F Cap & Disc: 416 SS ASTM A582 C A Connections: 3 8" 1" NPT Dimensions in inches (mm) Size A B C B Weight in Lbs. (kg) 3 /8" 2 1 3 /4 1 3 /4.8 (51) (44) (44) (.36) 1 /2" 2 11 /16 1 3 /4 2 1.2 (68) (44) (51) (.55) 3 /4" 2 13 /16 2 5 /16 2 7 /16 1.85 (71) (59) (62) (.86) 1" 3 5 /16 2 1 /2 2 7 /8 3.1 (84) (64) (73) (1.8) Maximum Capacity lbs/hr 10 F Below Saturation Differential PSIG (barg) NPT 3.5 5 10 20 30 50 75 100 150 200 300 400 500 600 Connection (0.24) (0.34) (0.7) (1.4) (2.1) (3.4) (5.2) (6.9) (10.3) (13.8) (20.7) (27.6) (34.5) (41.3) 3/8" 180 185 190 200 215 245 305 370 500 610 790 960 1100 1250 1/2" 300 310 345 410 465 575 700 810 1000 1140 1410 1630 1830 2000 3/4" 405 420 470 560 640 810 1000 1160 1450 1670 2100 2430 2750 3050 1" 640 670 725 865 980 1200 1470 1750 2200 2600 3250 3780 4250 4700 For Kg/Hr Multiply by.454 C3

S610 SERIES THERMODYNAMIC Pressures To 600 PSIG (41.3 barg) Temperatures to 800 F (426 C) Shown with optional tapped blowdown connection. Applications Steam Tracing Drips Heating Options Socketweld Connections Tapped Blowdown Connection Stainless Steel Blowdown Valve Celtron plastic-packed replaceable cartridge for fast and simple replacement Improved Energy Savings Lowers steam waste due to steam jacketing. Trap cycle is unaffected by ambient temperatures or precipitation. Extended Trap Life Integral strainer keeps disc and seat clean. Non-violent discharge reduces wear. Heavy disc prevents warpage and improves performance. Easily Maintained Completely renewable without disturbing piping connections by removing cover, unscrewing and replacing Celtron cartridge. Celtron replacement cartridges are packaged individually with cover and gaskets in a protective bag. Freeze Proof When mounted vertically or on its side horizontally. Multi-functional Integral check valve eliminates need for additional fittings. Economical First cost and maintenance cost are low. Spiral-wound Cover Gasket assures positive closure. Models S610 3/8" & 1/2" standard capacity S610L Low capacity on S610 S610S Tapped blowdown connection on S610 S610LS Tapped blowdown connection on S610L S610V Blowdown valve on S610 S610LV Blowdown valve on S610L S611 3/4" standard capacity S611L Low capacity on S611 S611S Tapped blowdown connection on S611 S611LS Tapped blowdown connection on S611L S611V Blowdown valve on S611 S611LV Blowdown valve on S611L S612 1" standard capacity S612S Tapped blowdown connection on S612 S612V Blowdown valve on S612 Operation Incoming air and condensate flow through the trap body and into the Celtron cartridge. Line pressure raises the disc off the seat allowing complete discharge. When flashing condensate enters the cartridge, flow velocity increases, creating low pressure underneath the disc. Flashing condensate at high velocity strikes the inside wall of the disc chamber and is deflected to the top of the disc causing a pressure buildup. The disc is forced down onto the seat by this pressure imbalance. The trap remains closed as steam in the jacket prevents exposure of the Celtron cartridge to ambient temperatures. Pressure inside the cap is not lowered until the trapped flash vapor condenses. Condensing steam lowers the pressure above the disc. Disc is then lifted and the cycle repeated. C4

S610 SERIES THERMODYNAMIC Typical Specification Steam trap shall be of thermodynamic capsule design. Body shall be of forged carbon steel construction housing stainless steel Celtron capsule. Celtron capsule shall contain all working components. Capsule shall be hardened throughout. Seat shall be stress relieved to eliminate warpage. Trap shall contain integral strainer with available blowdown port and valve. Cover shall seal to body utilizing spiral wound graphite gasket. Trap shall be suitable for pressures through 600 psi and available in 3/8" through 1". Maximum Operating Conditions PMO: Max. Operating Pressure 600 psig (41.3barg) TMO: Max. Operating Temperature 800 F (426 C) PMA: Max. Allowable Pressure 650 psig (44.8 barg) TMA: Max. Allowable Temperature 800 F (426 C) Materials of Construction Body & Cover: ASTM A105 Forged Steel Celtron Cartridge: 416 Stainless Steel w/hardened disc & seat Bolts: High temperature alloy Cover Gasket: 347 Stainless Spiral-wound w/graphite filler Integral Strainer: 304 Stainless Steel A C Connections: 3/8" 1" NPT or Scoketweld Dimensions in inches (mm) Weight in Lbs. (kg). Size A B C D 3 /8" 1 /2" 1 17 /64 21/32 3 1 /4 2 15 /32 2.3 lbs (32) (17) (83) (63) (1.05) 3 /4" 1 1 /2 3/4 3 3 /4 2 25 /32 3.4 lbs (38) (19) (95) (71) (1.5) 1" 1 19 /32 7/8 4 3 /16 3 15 /16 5 lbs (40) (22) (106) (100) (2.3) B D DISCHARGE CAPACITIES IN LBS. PER HOUR OF CONDENSATE NPT Threaded Differential PSIG (barg) or Socketweld Trap 5 10 25 50 75 100 200 300 400 600 Connections (0.34) (0.7) (1.7) (3.4) (5.2) (6.9) (13.8) (20.7) (27.6) (41.3) 3/8" 1/2" S610L 105 150 235 330 395 435 550 630 690 790 3/8" 1/2" S610 240 265 420 590 700 770 980 1120 1240 1400 3/4" S611 450 500 790 1130 1340 1460 1850 2100 2300 2630 3/4" S611L 105 150 235 330 395 435 550 630 690 790 1" S612 1090 1200 1900 2700 3200 3550 4450 5100 5650 6400 For Kg/Hr Multiply by.454 The S610 Series trap works efficiently at all line pressures between 2 and 600 psi and back pressures to 80% of line pressure. C5

S650 SERIES Pressures To 600 PSIG (41.3 barg) Temperatures to 800 F (427 C) SHOWN WITH OPTIONAL BLOWDOWN VALVE Applications Steam Tracing Drips Heating Options Stainless Steel Blowdown Valve Socketweld Connections Space Saving Design incorporates a built-in strainer and optional blowdown valve. Eliminates four connections and four fittings. Improved Energy Savings Lowers steam waste due to steam jacketing. Trap cycling is unaffected by ambient temperatures. Non-violent Discharge Soft discharge which is unique in a steam trap of this type. Easily Maintained Completely renewable without disturbing piping connections by removing cover, unscrewing and replacing Celtron cartridge. Celtron replacement cartridges are packaged individually with cover and gaskets in a protective bag. Optional blowdown valve permits easy strainer cleaning while in service. Freeze Proof When mounted vertically or on its side horizontally. Low in Cost Purchase and maintenance costs are low. Models S650 Y pattern body with screen and blowdown port tapped and plugged S650L Low capacity on S650 S650B Y pattern body with screen and blowdown port tapped and plugged S650BL Low capacity on S650B Celtron plastic-packed replaceable cartridge for fast and simple replacement Operation Incoming air and condensate flow through the trap body and into the Celtron cartridge. Line pressure raises the disc off the seat allowing complete discharge. When flashing condensate enters the cartridge, flow velocity increases, creating low pressure underneath the disc. Flashing condensate at high velocity strikes the inside wall of the disc chamber and is deflected to the top of the disc causing a pressure buildup. The disc is forced down onto the seat by this pressure imbalance. The trap remains closed as steam in the jacket prevents exposure of the Celtron cartridge to ambient temperatures. Pressure inside the cap is not lowered until the trapped flash vapor condenses. Condensing steam lowers the pressure above the disc. Disc is then lifted and the cycle repeated. C6

S650 SERIES Typical Specification Steam trap shall be of thermodynamic capsule design. Body shall be of forged carbon steel construction housing stainless steel Celtron capsule. Celtron capsule shall contain all working components. Capsule shall be hardened throughout. Seat shall be stress relieved to eliminate warpage. Trap shall contain integral Y pattern strainer with available blowdown valve. Cover shall seal to body utilizing spiral wound graphite gasket. Trap shall be suitable for pressures through 600 psi and available in 1/2"-3/4" NPT. Maximum Operating Conditions PMO: Max. Operating Pressure 600 psig (41.3 barg) TMO: Max. Operating Temperature 800 F (426 C) PMA: Max. Allowable Pressure 650 psig (44.8 barg) TMA: Max. Allowable Temperature 800 F (426 C) Materials of Construction Body & Cover: ASTM A105 Forged Steel Celtron Cartridge: 416 Stainless Steel w/hardened disc & seat. Cover Gasket: 347 stainless spiral wound w/graphite fill Strainer:.033 perf. 304 Stainless Steel Blowdown Valve: 416 Stainless Steel 2 7 /8 (73) 5 (127) DIMENSIONS IN INCHES (MM) SHOWN WITH OPTIONAL BLOWDOWN VALVE WEIGHT: 5 LBS. (2.3 KG) Connections: 1/2" or 3/4" NPT or socketweld 3 5 /16 (84) 2 1 /4 (57) 3 1 /2 (89) Maximum Capacity lbs/hr 10 F Below Saturation (Kg/hr 5 C Below Saturation) Differential PSIG (barg) Trap 5 10 25 50 75 100 200 300 400 600 (0.34) (0.7) (1.7) (3.5) (5.2) (6.9) (13.8) (20.7) (27.6) (41.3) S650L, S650BL 105 150 235 330 395 435 550 630 690 790 S650, S650B 240 265 420 590 700 770 980 1120 1240 1400 For Kg/Hr Multiply by.454 C7