THERMODYNAMIC STEAM TRAPS

Similar documents
LIQUIDATOR UMT-TD Series Thermodynamic

THERMODYNAMIC STEAM TRAPS

NICHOLSON STEAM TRAP THERMODYNAMIC STEAM TRAPS

LIQUIDATOR 450 SERIES

THERMOSTATIC STEAM TRAPS

CD-33/CD-33S Controlled Disc Steam Traps

Liquid Drainers LIQUID DRAINERS

FT600 & FT601* Steam Traps Float & Thermostatic Steam Trap. Float & Thermostatic STEAM TRAPS

PT15 MATERIAL : DIMENSIONS - Nominal in inches. AVAILABLE SPARES: Disc (Packet of 5) ORDERING INFORMATION: Refer to "HOW TO ORDER" page.

UNIVERSAL STYLE STEAM TRAPS WU450 Series

THE THERMOSTATIC STEAM TRAP

Technical Data CONDENSATE COMMANDER PUMP SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 9902D

Yarway Repairable Drip and Tracer Steam Traps Series 751/761, 711/721, 731/741, 500/546, 460/515/D3

Economical and simplified solutions that offer quality and optimum steam trap service.

YARWAY NON-REPAIRABLE DRIP AND TRACER STEAM TRAPS SERIES PB, 29, 129Y AND 29S

YARWAY PROCESS THERMODYNAMIC STEAM TRAPS SERIES 40/40D AND C250/260

Pump & Trap Combinations

Product. Add Efficiency To Your Steam Investment... Steam Traps Drain Traps Air Vents & Eliminators Accessories Piping Assemblies Replacement Kits

Hoffman Specialty General Catalog

Condensate Pumps Jones Boulevard Limerick Airport Business Center Pottstown PA Tel:

STEAM TRAPS

Pure Performance For Steam Mains and Tracers

TABLE OF CONTENTS STEAM TRAPS INVERTED BUCKET SERIES PAGE FLOAT AND THERMOSTATIC SERIES PAGE THERMOSTATIC THERMODISC B0 26. How to Select All 107

Steam Traps and Steam Specialties

Pamphlet A2404. Mechanical Pump & Pump/ Trap. GP Series GT Series

The right trap for the right application.

Inverted Bucket Float & Thermostatic Radiator Traps STEAM CONTROL PRODUCTS STEAM TRAPS

Float & Thermostatic Steam Traps for efficient condensate drainage of industrial process and HVAC equipment

STAINLESS STEEL TRAP VALVE STATION

Our Know-How. Your Peace of Mind. Steam Solutions

Hydrocarbon & Chemical Processing Solutions

Pure Performance For Steam Mains and Tracers

Ball Float Steam Trap with Integral Spiratec Sensor and Flanged Connections

Inverted Bucket Steam Traps. for efficient condensate drainage of industrial and HVAC equipment

Pamphlet U2404. Mechanical Pump & Pump/ Trap. GP Series GT Series

THERMODYNAMIC STEAM TRAP

S and SF Inverted Bucket Steam Traps Installation and Maintenance Instructions

Armstrong Steam System Solutions for the Hydrocarbon and Chemical Processing Industries

Wide range of steam traps that provide consistent performance in less than perfect conditions.

Disc Type Steam Trap TSD-42

opening trap 30 mm Space required for Space required for opening trap 30 mm MK 45-1 with flanged ends (to DIN)

Steam Trap Presentation for IDEA Distribution Workshop. Presenter: Joe Radle

Steam and Condensate Technology. Solutions which are brilliant in their simplicity. combined with a first-class design & consultancy service.

Armstrong Steam System Solutions for the Hydrocarbon and Chemical Processing Industries

Pamphlet M2404. Mechanical Pump & Pump/ Trap. GP Series GT Series

Installation and Maintenance Manual

FT14 Ball Float Steam Trap (Screwed)

High Capacity Instantaneous Steam Fired Water Heater

Mini Pump Trap. Features: n Low maintenance - No leaking seals, impeller or motor problems reducing maintenance and downtime.

Section H11 BLOWDOWN SEPARATORS CONTENTS FEATURES AND BENEFITS...H11-3 PRODUCT OFFERING...H11-3 SAMPLE SPECIFICATIONS...H11-11 ILLUSTRATIONS

INSTALLATION, OPERATION

AIC Series Float & Thermostatic Steam Trap Installation and Maintenance Instructions

FT14 and FT14HC. SG Iron Ball Float Steam Traps (1" HC, 1¼", 1½" and 2")

Yarway Narvik Steam Desuperheater Series 4300 TempLow

Installation and Testing of Inverted Bucket Steam Traps Manual

Ball Float Controlled. Thermo Dynamic(TD) Trap Safety Valve Condensate Pump Flash Vessel Moisture Separators Deaerator Head Steam Injector Sight Glass

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD

Steam Traps. . Chambered valves such as; bleeding & venting valves and steam traps. Float Valves using a free fl oat

PRODUCTS. Expansion Joints Fire Fighting. Flexible Metal Hoses. Equipments. Insulation Solutions. Steam. Valves. Level Control.

Armstrong J Series Float, Thermostatic Steam Traps, Condensate Controllers & Liquid Drainers Installation and Maintenance Manual

GESTRA. Program for Universal Connections. The Smart Solutions

MODELS N150/300/675/900/1500/2500/2600 INSTALLATION, SERVICING AND MAINTENANCE INSTRUCTIONS

HEAT GENERATION 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS. B. Section HVAC Basic Materials and Methods

Pamphlet A2000. TL\l. Free Float Steam Trap Series

Series 151 and AV5. A wide range of process thermostatic steam traps is available to match almost any application need.

ESCO. Committed. Group of Companies. to help conserve Steam Energy

High Pressure Water - Descale Valves - VXXX Series. Quad-S TM Poppet Cartridge Zero Leakage, Media Piloted Raw Water Operation

INSTRUCTION MANUAL. Keep this manual in a safe place for future reference TEMPERATURE CONTROL STEAM TRAP LEX3N-TZ LEX3N-TZ.

Installation and Maintenance Manual Forbes Marshall Tracer Line Trap FMMST63

Instant hot water Feed-Forward system unlimited supply accurate to +/- 4 F

Steam trap checking WHY WE NEED TO CHECK STEAM TRAPS METHODS OF CHECKING TRAPS ADVANTAGES AND DISADVANTAGES PRACTICAL DEMONSTRATION

Series 1140 and 1141 Temperature Regulators

YARWAY PROCESS THERMOSTATIC STEAM TRAPS SERIES 151 AND AV5

Air Vents AV-392. Proven Same proven, free-floating all stainless steel mechanism as used in Armstrong steam traps.

Documento Descargado desde:

APPLICATION GUIDELINES STEAM MAIN DRAINAGE

GEM TRAP FITTING & MAINTENANCE INSTRUCTIONS

Main Steam Vents. Hoffman Specialty Regulators. How to Select Steam Vents

SECTION Pipeline Ancillaries

Thermostatic Steam Traps

INSTRUCTION MANUAL. Keep this manual in a safe place for future reference. QuickTrap FX1 Trap Unit X1. Manufacturer

VENTS. Main Steam Vents. How to Select Steam Vents. For Steam Vent selection information, please refer to Selection Guidelines on page 133.

Steam trapping overview STEAM & CONDENSATE MANAGEMENT SOLUTIONS

BASICS OF STEAM TRAPS BASICS OF STEAM TRAPS

ICS Float and Thermostatic Steam Trap Installation and Operation Manual

Commercial, Residential & Institutional Pumps, Tanks, & Accessories

MECHANICAL STEAM TRAPS

PIP PNE00004 Steam Trap Guidelines

Installation and Maintenance "L" and "LS" Series

ø D ø g ø k Max. service [barg] pressure [psig] H 1 96 L BK 45 with butt-weld ends End connections Screwed Socket-weld

Chapter 2.3: Steam System

Boiler Condensate Return Basics. Presented by Steve Connor February 24, 2016

Compressed Air Dryers

THE PRESSURIZED CONDENSATE RECOVERY SYSTEM:

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT

STEAM AND TRAP FUNDAMENTALS

Pumps. Pressured-powered pump catalog. The more reliable and efficient way to pump condensate and other liquids.

MFP14 Automatic pumps. for condensate and other industrial fluids

WATER HAMMER something that never should occur in a steam system

STEAM CONSERVATION GUIDELINES

Transcription:

THERMODYNAMIC STEAM TRAPS Nicholson has a wide variety of Thermodynamic Steam Traps to accommodate applications through 600 psi. Most models utilize Nicholson s exclusive Celtron Cartridge. The Celtron facilitates inline maintenance while simultaneously providing superior performance. The all-stainless NTD 600 is the value leader of the line, providing the performance Nicholson users have come to expect in a conventional, recognizable design. 50

NTD600 SERIES THERMODYNAMIC STEAM TRAPS Pressures To 600 PSIG (41.3 barg) Temperatures to 800 F (426 C) Compact Design - Hardened stainless steel disc is the only moving part. Inexpensive - Low initial cost is less expensive than repairable technologies. Simplifies Installation - Works in vertical or horizontal position. Rugged - Handles water hammer and superheat. Reliable, Efficient Operation - Blast discharge helps to eliminate dirt buildup and provides tight shutoff Freeze resistant - Self draining design prevents freezing. All Stainless Steel Construction - Resists both internal and external corrosion. Easy to Monitor - Audible discharge cycle makes checking operation simple. Applications Steam Tracing Drips Heating MODELS NTD600 Thermodynamic Disc Trap NTD600S NTD600 with integral strainer NTD600B NTD600S with blowdown valve Installation Tip: Always install STV Test & Block Valve as part of trap station SEE PAGE 118 Installation Tip: Add Uniflex Pipe Coupling for ease of maintenance SEE PAGE 102 NTD600 Model Only: Canadian Registration # OE0591.9C Operation Incoming air and condensate flow through the trap body and into the control chamber. Line pressure raises the disc off the seat allowing complete discharge. When flashing condensate enters the cartridge, flow velocity increases, creating low pressure underneath the disc. Flashing condensate at high velocity strikes the inside wall of the disc chamber and is deflected to the top of the disc causing a pressure buildup. The disc is forced down onto the seat by this pressure imbalance. The trap remains closed as flashed vapor in the control chamber keeps the disc seated. Pressure inside the cap is not lowered until the trapped flash vapor condenses due to body radiation. Condensing steam lowers the pressure above the disc. Disc is then lifted and the cycle repeated. 51

NTD600 SERIES THERMODYNAMIC STEAM TRAPS SPECIFICATION Steam trap shall be of thermodynamic design. Body shall be of all stainless construction and hardened throughout. Seat shall be integral to body. Cover shall seal to body without gaskets or seals. Trap shall be suitable for pressures through 600 psi and available in 3/8" through 1". Maximum operating conditions PMO: Max. Operating Pressure 600 psig (41.3 barg) TMO: Max. Operating Temperature 800 F (426 C) PMA: Max. Allowable Pressure 600 psig (41.3 barg) TMA: Max. Allowable Temperature 800 F (426 F) A Materials of construction Body... 420F SS ASTM A743 CA40F Cap & Disc... 416 SS ASTM A582 Blow Down Valve... 304/316SS Screen... Stainless Steel Dimensions Inches (mm) Size A B C 3 8'' 1 2'' 3 4" 1" 2 (51) 2c (68) 213 16 (71) 35 16 (84) 13 4 (44) 13 4 (44) 25 16 (59) 21 2 (64) 13 4 (44) 2 (51) 27 16 (62) 27 8 (73) Weight lbs (kg).8 (.36) 1.2 (.55) 1.85 (.86) 3.1 (1.8) Connections: 3/8 1 NPT Maximum Capacity lbs/hr 10 F Below Saturation NPT Connection 3.5 (0.24) 5 (0.34) 10 (0.7) 20 (1.4) 30 (2.1) 50 (3.4) Differential PSIG (barg) 75 (5.2) 100 (6.9) 150 (10.3) 200 (13.8) 300 (20.7) 400 (27.6) 500 (34.5) 600 (41.3) 3/8" 180 185 190 200 215 245 305 370 500 610 790 960 1100 1250 1/2" 300 310 345 410 465 575 700 810 1000 1140 1410 1630 1830 2000 3/4" 405 420 470 560 640 810 1000 1160 1450 1670 2100 2430 2750 3050 1" 640 670 725 865 980 1200 1470 1750 2200 2600 3250 3780 4250 4700 For Kg/Hr Multiply by.454 NOTE: The NTD600 Series works efficiently at all line pressures between 5 & 600 psi and back pressures up to 80% of line pressures. 52

LIQUIDATOR UMT-TD SERIES THERMODYNAMIC STEAM TRAP Pressures To 450 PSIG Temperatures to 650 F Applications Unit Heaters Laundry Equipment Steam Tracing Plating Tanks Drip Legs Platen Presses Tire Presses Cooking Equipment Easily Maintained Four bolt cover permits easy in-line rebuilding for less than the cost of replacement. Durability and Long Service Life Stainless steel body and cover with stainless steel Celtron Cartridge for maximum corrosion, thermal and hydraulic shock resistance. Optional Integral Strainer Helps prevent dirt and scale buildup on valve seat. Excellent Energy Savings Positive shutoff assures no loss of steam during normal operation. Unaffected by Ambient Conditions Steam jacketing minimizes steam loss. Blast Discharge Clears away dirt and scale. Fits all Universal Connectors Liquidator body will replace any manufacturers universal mount trap body. 3 Year Guarantee Guaranteed against defects in material and workmanship. Easily Replaced Two bolt design permits rapid removal without breaking pipe connections. Freeze Proof Self draining when installed vertically 53

LIQUIDATOR UMT-TD UNIVERSAL MOUNT THERMODYNAMIC STEAM TRAPS Pressures To 450 PSIG (31 barg) Temperatures to 650 F (343 C) Easily Maintained - Universal two bolt swivel mounting simplifies removal from system. Kits allow flexibility to replace or rebuild. Simple Installation - Stainless mounting block mounts permanently into system. Trap installs via two bolt universal connection. Improved Energy Savings - Lowers steam waste due to steam jacketing. Trap cycle is unaffected by ambient temperatures or precipitation. Extended Trap Life - Integral strainer keeps disc and seat clean. Non-violent discharge reduces wear. Heavy disc prevents warpage and improves performance. Easily Maintained - Completely renewable without disturbing piping connections by removing cover, unscrewing and replacing Celtron cartridge. Celtron replacement cartridges are packaged individually with cover and gaskets in a protective bag. Freeze Proof - When mounted vertically or on its side horizontally. Economical - First cost and maintenance cost are low. Celtron plastic-packed replaceable cartridge for fast and simple replacement Applications Steam Tracing Drips Light Process Options SW - Socketweld Connections B - Blowdown Valve UMT-TD SERIES TRAP AND UMTC CONNECTOR MODELS UMT-TD10L - Low Capacity Trap UMT-TD10 - Standard Capacity Trap UMTC - Standard connector (1/2" & 3/4" only) UMTCY - Connector w/y strainer UMTCYR - Right Hand Connector w/y strainer UMTCYL - Left Hand Connector w/y strainer PUMTVS-BB P - Connector with Isolation Valves, Strainer, Blowdown Valve and Test Port For complete unit, order trap and connector as separate items. For information on Big Block UMTVS-BB Connector SEE PAGE 116 Canadian Registration # 0E13886 Operation Incoming air and condensate flow through the trap body and into the Celtron cartridge. Line pressure raises the disc off the seat allowing complete discharge. When flashing condensate enters the cartridge, flow velocity increases, creating low pressure underneath the disc. Flashing condensate at high velocity strikes the inside wall of the disc chamber and is deflected to the top of the disc causing a pressure buildup. The disc is forced down onto the seat by this pressure imbalance. The trap remains closed as steam in the jacket prevents exposure of the Celtron cartridge to ambient temperatures. Pressure inside the cap is not lowered until the trapped flash vapor condenses. Condensing steam lowers the pressure above the disc. Disc is then lifted and the cycle repeated. 54

LIQUIDATOR UMT-TD UNIVERSAL MOUNT THERMODYNAMIC STEAM TRAPS SPECIFICATION Steam trap shall be of a thermodynamic capsule design. The body shall be of a 304 stainless steel 2 bolt universal swivel construction with a stainless steel in line renewable Celtron capsule. Celtron capsule shall contain all working components. Capsule shall be hardened throughout. Seat shall be stress relieved to eliminate warping. Trap shall seal to body with spiral wound graphite gaskets. Trap shall be suitable for pressures through 450 psi and available in 1/2" through 1" NPT or socketweld connections. UMT-TD SERIES TRAP AND UMTC CONNECTOR 3.5 (8.89) 4.8 (122).75 (19) 1.25 (3.18) 2.6 sq. (66 sq.) 2.81 (71) Connections: 1/2", 3/4" or 1" NPT or socketweld 5 (12.7) Maximum operating conditions PMO: Max. Operating Pressure (41.3 barg) (31 barg) TMO: Max. Operating Temperature 650 F (343 C) PMA: Max. Allowable Pressure 450 psig (31 barg) TMA: Max. Allowable Temperature 650 F (343 C) 3.44 (8.74) NICHOLSON R UMTCYR Materials of construction Body & Cover:... ASTM A351 Grade CF8 (304) Cover Gasket:... 304 stainless spiral wound w/graphite fill Celtron Cartridge:... 416 Stainless Steel w/hardened disc & seat Strainer:...(.033 perf.) 304 Stainless Steel Mounting Block:...ASTM A351 Grade CF8 (304) UMTCYL 5 (12.7) 1.25 (3.18) 3.5 (8.89) NICHOLSON L 3.44 (8.74) DIMENSIONS - INCHES (MM) WEIGHT TRAP - 3.2 LBS. (1.4 KG) STD. MOUNTING BLOCK - 1.1 LBS. (0.5 KG) Y STRAINER MOUNTING BLOCK - 2.3 LBS. (1.0 KG) Trap 5 (0.34) 10 (0.7) Maximum Capacity lbs/hr 10 F Below Saturation Differential PSIG (barg) 25 (1.7) 50 (3.4) 75 (5.2) UMT-TD10L 105 150 235 330 395 435 550 630 690 715 UMT-TD10 240 265 420 590 700 770 980 1120 1240 1280 For Kg/Hr Multiply by.454 100 (6.9) 200 (13.8) 300 (20.7) 400 (27.6) 450 (31) The UMT-TD Series trap works efficiently at all line pressures between 5 and 450 psi and back pressures to 80% of line pressure. 55

NOTES 56