OPERATING INSTRUCTIONS

Similar documents
OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS

OPER LV Wheeler Way

Operation and Maintenance Manual

RecoverX Oil-Filled Hermetic Refrigerant Recovery System. Operation and Maintenance Manual

Enspeco RMS. The Enspeco Refrigerant Management. The following instructions will INSTRUCTIONS

R100 Oil-Less Refrigerant Recovery Unit

RecoverX-CAR Contaminated Automotive Refrigerant Recovery System Operation and Maintenance Manual

OPERATION & MAINTENANCE MANUAL TX600

OWNER S MANUAL (English)

Pro-Set TRA21 SERIES Mobile Multiple Refrigerant Recovery / Recycle System

ENSPECO Recovery/ Recycle/ Evacuate/ Recharge

OPERATION & MAINTENANCE MANUAL TC670

OWNER S MANUAL (English)

TRS21 IGNITION PROOF SERIES

WMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS

TRS21 IGNITION PROOF SERIES

Refrigerant Recovery Machine. Model No Operating Manual

14. The center port of the manifold is used for evacuation, charging and refrigerant recovery.

OPERATION & MAINTENANCE MANUAL RHS680

OPERATION & MAINTENANCE MANUAL AC860

ariazone 601HD Refrigerant Recovery & Recycling Unit User's manual

User manual Flushing device VAS 6337/1a

5/12/2018 Climate Control System General Information and Diagnostics - Air Conditioning (A/C) System Recovery, Evacuation and Charging - G

Owner s Manual. Model AC375C Refrigerant Recovery, Recycle, and Recharge Unit

SECTION 50 - CAB CLIMATE CONTROL

Ariazone 601HD Refrigerant Recovery&Recycling unit

Additional users operating manual

CC Series VACUUM PUMPS

Air Dryers & After Coolers Dry Land

Owner s Manual. Terpene Trap CF 1000

Model K / K. Modelo K / K. Modèle K / K. Operating Manual

Refrigerant Recovery Unit, Model RRU134

NEUTRONICS MINI ID R-1234yf REFRIGERANT IDENTIFIER OPERATION MANUAL

High Performance Oilless Residential Light Commercial. Product Leadership Training Service Reliability

Horizontal Bottle Cooler Installation and Operation Manual

Operating Manual, Model K/348012K Recovery/Recycling/Recharging Unit For R-12 and R-134a Refrigerants...1

Operation Manual... 1 Manuel d utilisation Manual de Operación.. 60

SECTION AIR COMPRESSORS AND ACCESSORIES

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system

USER S OPERATING AND INSTRUCTION MANUAL

REFRIGERANT RECOVERY SYSTEMS

YELLOW JACKET Recovery Machines for every refrigerant, every size system

Automotive Air-Conditioning Service Equipment Ariazone 5001HD OPERATOR MANUAL Ariazone 5001HD

Residential Piping and Long Line Guideline

SFD. Suburban Filter Dryer. User Manual Installation Instructions

Reference Document RD-0007-E GUIDELINES FOR THE UTILIZATION OF R-404A R-452A. Page 1 of Tecumseh Products Company LLC. All rights reserved.

INSTALLATION INSTRUCTIONS TXV Horizontal Slab Coils WLSH

Some of these procedures need to be performed to conform to requirements of the Clean Air Act.

BLOCK ICE MAKERS BY DELTA ICE, AIR AND HEAT INC.

Digital Refrigerant System Analyzer. MAXMIN Psi kpa Bar MPa C F R TIME P T UNITS

WKS 4000 SERIES (USA only) --INSTALLATION INSTRUCTIONS--

DRY AIR SYSTEMS, INC Metro Boulevard Maryland Heights, Missouri (314) fax (314)

OPERATION & MAINTENANCE MANUAL AC880

Oilless Refrigerant Recovery System. OWNER S MANUAL (English) TO BE OPERATED BY QUALIFIED PERSONNEL ONLY

347002K/177002K/34900

Owner s Manual Refrigerated Compressed Air Dryers Models F-3528, F-3529, F-3530, F-3531 & F-3532

NZQA Expiring unit standard 3397 version 4 Page 1 of 5. Convert an automotive air conditioning system from R-12 to R-134a

INSTRUCTIONS RHS 700. Recovery, Recycling, Evacuation and Charging Station RHS 700

DLCLRA. INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 TABLE OF CONTENTS

Vacuum Oil Purifier (VOP) (5 Pages. June 2017)

OWNER S MANUAL (English)

Turbo Air Speed up the Pace of Innovation TBB-4SB CAUTION! PLEASE KEEP POWER SWITCH ON BEFORE OPERATING THIS EQUIPMENT

Operating Manual Manual de Operación Manuel d utilisation

"SWVP - SWHP" COMMERCIAL WATER SOURCE HEAT PUMPS & AIR CONDITIONERS

OPERATING MANUAL. Model 34134Z. Refrigerant Unit Recover, Recycle, and Recharge

Ariazone 5001 HFO-1234yf

Caresaver Universal Refrigerant Recovery Unit

OPERATING MANUAL MODEL AIR 1500TM AIR DRYER

R E D I C O N T R O L S

WKS 2200 SERIES (USA only) --INSTALLATION INSTRUCTIONS--

Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System

Module 7: Air Supply System

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD

Rev. None AUGUST 2012 MDM SERIES MODULAR MEMBRANE AIR DRYERS OPERATOR MANUAL MDM1 MDM4 MDM9 MDM13 MDM24 MDM49 MDM66 MDM106 MDM138

Quest Dry 105, 155, and 205 Dual

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD

Chapter 6. Do s & Don ts in Refrigeration & Air-Conditioning Servicing

V LPM Desiccant Air Dryer Installation and Operation Manual

INSTRUCTIONS! DO NOT DISCARD!

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system

LITTLE BLASTER SET-UP INSTRUCTIONS FOR SHOT PEEN MACHINES WITH CARTRIDGE TYPE DUST COLLECTORS *** READ BEFORE OPERATING EQUIPMENT***

Installation Instructions

Operating Manual. Model K/ K Recovery/Recycling/Recharging Unit

COMMERCIAL REFRIGERATOR INSTRUCTION MANUAL

3. What are the main parts in a compressed air generation? And list the flow path in order? 4. Draw the ISO symbol for an air compressor.

Vacuum Gauge. Measures lower-than-atmospheric pressure Digital scales. microns psi in. Hg millibars pascals torr millitorr

Glass Door Merchandiser Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment!

CS/CD/CP AIR COOLED CONDENSING UNITS (P/N E207120C R2)

Milk Coolers Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment!

National Maritime Center

Owner s Manual Refrigerated Compressed Air Dryers Models F-200, 250, 300 & F350

NORDYNE has received reports of malfunctioning TXV valves in ton split systems and package units.

Installation Manual for CCS Cased Coils with SC, SD, SW Compressor Units and R-410A Refrigerant

OWNER/OPERATOR MANUAL COMPONENTS, INSTALLATION, OPERATION AND SERVICE INSTRUCTIONS

Operating Manual. Model 34700Z / 17700Z Recovery, Recycling, Recharging Unit

Publication # RD-0003-E Rev 1, 10/17 SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS

VF/VG700 Jumbo. Construction Heater. Installation and Maintenance Manual

OWNER S MANUAL #DC2000Y #DC2000YCF 2 HP, 1500 CFM DUST COLLECTOR. VERSION 1 -w/ 6 INLET PORT. Model #DC2000Y Global Rd.

INSTALLATION INSTRUCTIONS TXV Coils for Manufactured Housing EMA

Transcription:

OPERATING INSTRUCTIONS MODEL LV8 COMMERCIAL REFRIGERANT RECOVERY UNIT NATIONAL REFRIGERATION PRODUCTS 985 WHEELER WAY LANGHORNE, PA 19047 (215) 638-8909 FAX (215) 638-9270 A01001 7/11/96 NRP-OM-LV8 7/96 Obsoletes LV8 6/15/92

MODEL LV8 For safety reasons it is very important to fill all cylinders by weight in accordance with the cylinder supplier s instructions and ARI guidelines. The LV8 is a large capacity refrigerant transfer unit for use with R12, R22, R114, R134a, R500 & R502. ALWAYS USE HIGH PRESSURE CYLINDERS WITH 2 VALVES. CYLINDERS MUST BE DOT APPROVED, SUCH AS CYLINDERS SUPPLIED BY NRP. DO NOT OVERFILL CYLINDERS. Cylinders should be filled to a maximum of 80% capacity. DO NOT MIX DIFFERENT REFRIGERANTS IN A CYLINDER. Mixtures can not be separated. ALWAYS WEAR RUBBER GLOVES AND SAFETY GOGGLES WHEN TRANSFERRING REFRIGERANT. BEFORE FILLING AN EMPTY CYLINDER, ALWAYS EVACUATE THE CYLINDER TO AT LEAST 1000 MICRONS TO REMOVE AIR AND NON-CONDENSABLES. NON-CONDENSABLES WILL INCREASE DISCHARGE PRESSURE DRASTICALLY. PLEASE EVACUATE OR PURGE THE LV8 RECOVERY UNIT AND HOSES BEFORE YOUR RECOVERY JOB TO AVOID INTRODUCING NON-CONDENSABLES IN THE RECOVERY CYLINDERS. ALWAYS USE A 163 FILTER DRIER BEFORE THE INLET VALVE OF THE LV8. THIS DRIER WILL CAPTURE PARTICULATE AND WILL PREVENT DAMAGE TO THE REFRIGERANT PUMP, O-RINGS AND INTERNAL SEALS OF THE LV8. 2

HOW TO USE THE LV8 The NRP LV8 is simple to use because it will pump either refrigerant liquid or vapor in the same way, shown in Figure 1. There is no need to change the piping or valve settings of the unit. There is no risk of damage by running the pump dry. POWER REQUIREMENTS The LV8 includes its own 1.5 HP oil-less compressor, wired for 230 Volt, single phase, 60 Hertz. When operating with its own compressor, the LV8 does not need an outside air supply. The compressor is turned on or off by the main power switch. The condenser fan is always on when the unit is plugged in. If there is an outside air supply, the LV8 can be run on plant air. Dry compressed air at 10 CFM at 100 PSI is best and recommended. If there is a lower air pressure or capacity, the pumping capacity of the pump will be reduced. There is a shut-off valve at the air inlet to shut off air to the pump. This allows the pump to be turned on and off. The LV8 must be plugged in to provide power to the condenser fan. Please drain moisture which accumulates in the moisture separator on the air inlet side of the LV8 to avoid damage to the pump. The air supply to the LV8 is not to be lubricated in any way, and if a rental compressor is being used, make sure that the air supply is coming off the dry or non-lubricated port of the air compressor. Some of the air compressors from equipment rental dealers, used for jackhammers, have an automatic oiler. Make sure not to use that air outlet. 3

REFRIGERANT RECOVERY - ( SEE FIGURE 2) During refrigerant recovery the LV8 valves should be set as shown in Figure 2. Since it is faster to recover refrigerant liquid than vapor, the refrigerant should be removed through the liquid side of the system. A 3/8 flared. fitting should be used, with 3/8 refrigerant charging hoses. For convenience use a sight glass in line at the refrigerant outlet of the LV8 condenser. After the liquid has been removed, the left over vapor can be pumped out of the unit until the suction gauge on the LV8 reaches 0 PSIG. The LV8 will pull to a 20 Hg vacuum. 4

SELF PUMP-OUT OF RECOVERY UNIT (FIGURE 3) To avoid mixing refrigerant, it is important that at the end of each recovery operation, the refrigerant left in the LV8 recovery unit must be pumped out. This is shown in Figure 3. The LV8 has a self pump-out system (Patent Pending) which is very easy to use. 1. Close inlet ball valve. 2. Open outlet valve of LV8 and recovery cylinder valve. 3. Turn LV8 power on. 4. When suction pressure gauge on the LV8 reaches 0 PSIG, self pump-out is complete. 5. When self pump-out is complete shut cylinder valve and outlet valve. 6. A total evacuation of the unit can only be obtained by using a vacuum pump. 5

MAINTENANCE Caution: Never lubricate this dry oil-less compressor. The Teflon filled rings are self-lubricating and do not require oil. The motor bearing are grease packed for the life of the bearing. Warning: TO AVOID EXPLOSIVE HAZARD, DO NOT PUMP COMBUSTIBLE LIQUIDS OR VAPORS WITH THESE UNITS OR USE IN AN AMBIENT THAT CONTAINS COMBUSTIBLE VAPORS OR LIQUIDS. Under certain ambient temperature of 40 F or lower, the exhaust air from the LV8 can cause ice formation, causing the LV8 to stop pumping. Placing the pump in a warmer area can solve this problem. After using the LV8 for removing highly contaminated refrigerants, use a few pounds of clean refrigerant to pump through the LV8 to clean out the LV8 pump. IMPORTANT NOTE: For trapping of particles, filter-drier size 163 must be installed at the refrigerant inlet of the LV8. The drier should be replaced after each job or as often as required, depending on the amount of rust and particulate which are in the system being pumped out. This will greatly reduce the amount of wear on the internal O-ring seals in the LV8. THE LV8 AIR COMPRESSOR COMES WITH A PRE-SET SAFETY VALVE. DO NOT MAKE ANY ADJUSTMENTS TO THIS VALVE. IF THE VALVE MALFUNCTIONS REPLACE IT. MAKE SURE THE PRESSURE REGULATOR IS FULLY OPEN WHEN USING THE LV8 AIR COMPRESSOR. OTHERWISE, THIS COMPRESSOR SAFETY VALVE MAY UNLOAD. 6

WARRANTY National Refrigeration Products (NRP) Recovery Equipment is warranted to be free of manufacturing defects. NRP will repair or give credit for repair, at NRP s choice, if any NRP Recovery units or accessories have manufacturing defects. Any warranty claim must be submitted in writing within one year of purchase with a copy of the invoice. In no event shall NRP be liable for the cost of the labor charges, lost profits, injury to good will, or any other special or consequential damages for defective goods, late delivery, or non-delivery. There are no warranties which extend beyond the description on the face hereof, and NRP makes no warranty of merchant ability or fitness for specific purpose. Warranty does not cover damage by improper operation or abuse. 7