You in Control PRODUCT OVERVIEW

Similar documents
HS-100 AT-A-GLANCE MODEL NUMBER: HS-100-N 4-Wire Ionization Duct Smoke Detector HS-100-P 4-Wire Photoelectric Duct Smoke Detector

PRODUCT OVERVIEW SM-501 AT-A-GLANCE

PRODUCT OVERVIEW. SL-2000 AT-A-GLANCE MODEL NUMBER: SL-2000-N 4-Wire Ionization Duct Smoke Detector SL-2000-P 4-Wire Photoelectric Duct Smoke Detector

You in Control PRODUCT OVERVIEW SM-501 AT-A-GLANCE

Air Specialties Express, 448 S. Main St., P. O. Box , Verona, WI Phone: (877) Fax: (608)

Air Specialties Express, 448 S. Main St., P. O. Box , Verona, WI Phone: (877) Fax: (608)

RT-3000 SERIES NEMA 4X TYPE 4X ENCLOSURE WATERTIGHT CORROSION RESISTANT DUCT SMOKE DETECTORS

Installation Manual: PAD100-DUCTR Analog Addressable Duct Detector

utomation omponents nc.

Application Data ! WARNING FACTORY INSTALLED SMOKE DETECTORS FOR SMALL AND MEDIUM ROOFTOP UNITS 2TO25TONS TABLE OF CONTENTS PART NUMBERS

Installation Instructions

DH100ACDCI Ionization Air Duct Smoke Detector

DH100ACDCI Ionization Air Duct Smoke Detector

DETECTOR TEST LOG. Detector Identification Information DHX-501 INTELLIGENT AIR DUCT SMOKE DETECTOR HOUSING INSTALLATION AND MAINTENANCE INSTRUCTIONS

D350PL INTELLIGENT PHOTOELECTRONIC DUCT SMOKE DETECTOR WITH EXTENDED AIR SPEED RANGE INSTALLATION AND MAINTENANCE INSTRUCTIONS

TRN100BPT, TRN100BP, and TRN100BPC Air Duct Smoke Detector with Extended Air Speed Range

INSTALLATION AND MAINTENANCE

Installation Instructions

DH500ACDC Intelligent Air Duct Smoke Detector Housing

D350RPL INTELLIGENT PHOTOELECTRONIC DUCT SMOKE DETECTOR WITH EXTENDED AIR SPEED RANGE INSTALLATION AND MAINTENANCE INSTRUCTIONS

DH100ACDCLP Air Duct Smoke Detector with Extended Air Speed Range

E-PDD Duct Smoke Detector Installation Sheet

DH100LP Air Duct Smoke Detector with Extended Air Speed Range

SK-Duct Air Duct Smoke Detector

DH200PL Intelligent Air Duct Smoke Detector with Extended Air Speed Range

DH200PL Intelligent Air Duct Smoke Detector with Extended Air Speed Range

Duct smoke housings, 4-wire D341/D341P and D342/D342P

DH500 Intelligent Air Duct Smoke Detector Housing

D2E Duct Smoke Detector

DH400 Air Duct Smoke Detector

TrueAlarm Analog Sensing

DH200RPL Intelligent Air Duct Smoke Detector with Extended Air Speed Range

MANUAL RESET ALARM RELEASE BOX

Duct smoke housing, 2-wire D340/D340P

DNR Duct Smoke Detector

7251DH Intelligent Air Duct Smoke Detector

Wiring Instructions for the 2900 Series FIREGUARD Combination Door Closer-Holder and Releasing Device with Integral Smoke Detector

FX-PDD Duct Smoke Detector Installation Sheet

DNRHS Intelligent Air Duct Smoke Detector

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information)

DNRECL Eclipse Duct Smoke Detector

DNR Duct Smoke Detector

TrueAlarm Analog Sensing

DUCTSD Duct Smoke Detector

MR-2602 Two Zone Fire Alarm Control Panel

MANUAL RESET ALARM RELEASE

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

Addressable Detectors & Bases

8600 EMR SERIES. INSPK NO Rev.06/ INS NO. GENERAL DESCRIPTION

Single Doors FIREGUARD Series Use one Master Unit each door or one 2409 Support unit each door. Pairs of Doors

Conventional Smoke Detectors KFAPO

TS93 EMR WITH SMOKE DETECTOR

Specification/ Data Sheet

AL1042ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev X

Wiring Instructions. Single Doors 99 Checkmate Series Use one or Master Unit each door or one or Support unit each door

WARNING. Installation Tip: Try out this unit before installing onto a fire door system. Test and learn the release INTRODUCTION

AL1002ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev X

Installation Manual CFP-105. Fire Alarm Control Panel. Version 1.0

MANUAL RESET ALARM RELEASE

, -9686, -9688, -9755, Duct Detector/Sensor Installation Instructions

DNR-AUS Duct Smoke Detector

M O D E L S F I R E G A R D M C V ADVANCE FIRE CONTROL RELEASE DEVICE

Reshaping Duct Smoke Detection

Addressable NAC Output Module D327A

DUCT SMOKE DETECTOR D4120

SPECIFICATION FOR A TOTAL FLOOD ECARO-25 TM CLEAN AGENT FIRE SUPPRESSION SYSTEM FOR USE WITH THE SHP PRO CONTROL PANEL SYSTEM

MADE IN THE U.S.A. ADVANCE FIRE CONTROL MODEL LM21-AFC MANUAL RELEASE DEVICES TEST WEEKLY TO ASSURE PROPER OPERATION OF RELEASE DEVICE/CONTROL PANEL

TECHNICAL DATA OBSOLETE

Reshaping Duct Smoke Detection

Conventional Releasing Control Panel

LiftMaster 300 Windsor Drive Oak Brook, IL LiftMaster.com

ED820-24V MODEL INSTRUCTION MANUAL. fire DETECTOR

Remote NAC Power Supply D7038

Fire Alarm System Fundamentals

SECTION FIRE ALARM SYSTEMS

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

AL600ULADA. NAC Power Extender. Installation Guide

AL1042ULADA. NAC Power Extender. Installation Guide (See Application Guide for additional information) Rev

Wiring Instructions (01-09)

RELEASE DEVICE CONTROLS

FireNET FN-LCD-S Serial Annunciator Installation and Operation Manual

Installation Instructions Models FDBZ492, FDBZ492-R and FDBZ492-HR

DH100ACDCLPX Air Duct Smoke Detector with Extended Air Speed Range

PSN-1000 & PSN 1000(E) Installation Manual

AL800ULADA. NAC Power Extender. Installation Guide

TYPE C: RETURN AIR UNDER POSITIVE PRESSURE FROM SEPARATE BLOWER

MODEL B2 INSTALLATION MANUAL

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST FIRE ALARM SYSTEM INSTALLATION

PULL STATION SERIES DIE-CAST METAL MANUAL PULL STATIONS

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

Model 17A00 Expansion Enclosure

D343. Installation Instructions. Air Duct Smoke Housing

Fire Alarm Acceptance Testing & On-Going Maintenance with The Joint Comm. Standards / Reporting. Prepared Especially for : OSFM TEC 2016

D7050DH. Installation Instructions. Multiplex Photoelectric Duct Smoke Detector

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

Transcription:

AIR PRODUCTS AND CONTROLS You in Control AIR PRODUCTS AND CONTROLS INC. INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR SERIES PLENUM DUCT SMOKE DETECTORS NO-FLOW LOW-FLOW SPECIAL APPLICATION -N -P PRODUCT APPLICATION Series plenum / duct smoke detectors provide early detection of smoke and products of combustion present in air moving at no or low flow through an HVAC duct supply, return, or both in commercial, industrial, and residential applications. These devices are designed to prevent the recirculation of smoke in areas by the air handling system s fans and blowers. Complete systems may be shut down in the event of smoke detection. 4-Wire, Ionization Type 4-Wire, Photoelectric Type PRODUCT OVERVIEW To minimize the impact of air turbulence and stratification on performance, a duct smoke detector should be located as far as possible downstream from any obstruction (i.e. deflector plates, elbows, etc.). In plenum space applications, turbulent areas would be preferred over areas considered dead spots, or areas that do not have active velocity when typical system airflow is present. In all situations, confirmation of velocity is required. The is designed specifically for applications where our standard external mount duct detectors cannot be utilized. Examples include air shafts, plenum spaces or applications requiring extremely low or no air velocity 100 ft/min. A compatible Listed MS- or MSR- Series remote indicator must be installed in a visible position with the. NOTE: For the correct installation of a duct smoke unit, please refer to the NFPA 72 (National Fire Alarm Code), NFPA 90A (Standard for Installation of Air Conditioning and Ventilation Systems),NFPA 92A (Recommended Practice for Smoke Control Systems.), NFPA 5000 (Building Construction and Safety Code), IMC (International Mechanical Code), and IFC (International Fire Code). This detector is not intended for open area protection nor should it be used for early warning detection or replace a regular fire detection system. REMOTE ACCESSORIES Audible and visual alarm indicators, remote status indicators, and remote reset/test switches can be accommodated by the Series duct units by connecting to DC voltage output terminals as described on Page 3. These terminals are not supervised and the voltage/current will only be present when the detector unit is in alarm. The remote pilot (green) LED will be permanently illuminated when connected to the output terminals as long as input power and detector head are present. AT-A-GLANCE MODEL NUMBER: -N 4-Wire Ionization Duct Smoke -P 4-Wire Photoelectric Duct Smoke PRODUCT DESCRIPTION The Series smoke detector is fitted with a mounting base that will accept an ionization smoke detector head model 55000-225 or photoelectric smoke detector head model 55000-328. The duct unit supports one set of form C alarm contacts, one form A alarm contact and one form B trouble contact. The trouble contact supervises the presence of the input power and the removal of the smoke detector head. The trouble contacts will not operate in the event of a smoke alarm. The Series duct detector will operate from various input voltage sources; namely 24VAC, 24VDC, 115VAC and 230VAC. SAMPLING The operating principle of this duct detector is based on air flowing through the duct and passing over the detector head. When the concentration of smoke particles suspended in the air stream reach the alarm threshold of the detector head, the unit will go into alarm. The duct smoke detector units are designed to operate in spaces with an air velocity between 0 to 3,000 feet per minute. To verify correct installation, the air velocity should be measured using a velocity meter. An acceptable reading is between 0 and 2,000 ft/min for the -N; between 0 and 3,000 ft/min for the -P. 1 DETECTOR HEAD MODEL NUMBER: Ionization Head: 55000-225 Photoelectric Head: 55000-328 POWER REQUIREMENTS: 60 Hz STANDBY CURRENT ALARM CURRENT 24VAC 54.4mA 24VAC 139mA 24VDC 15mA 24VDC 48mA 115VAC 31mA 115VAC 34mA 230VAC 18mA 230VAC 20mA UNIT RATINGS: Alarm contacts: 1 Set form C rated at 10A@115VAC resistive 1 form A rated at 2A Trouble contact: 1 form B rated at 10A @ 115VAC resistive Air velocity: 0 to 3,000 ft/min. Ambient temperature: -N: 32 F to 158 F (0 C to 70 C) -P: 32 F to 140 F (0 C to 60 C) Humidity: 0% to 85% RH Non-Condensing/Non-Freezing Material: White plastic base/housing and detector (Makrolon 94V-0) Dimensions: 6.0" Dia X 4.0" H Overall / 2.6" H from back box front Max. net wt.: 1.0 lb. Radioactive element: -N (Ionization) - Americium 241, 0.9 micro curie. Mounting: Standard 4" square back box (by others) Do not expose to corrosive atmospheres.

MECHANICAL INSTALLATION LOCATION PREREQUISITES This guideline contains general information on duct smoke detector installation, but does not preclude the NFPA and/or ICC documents listed. Air Products and Controls assumes no responsibility for improperly installed plenum/duct smoke detectors. To determine the correct installation position for an Series duct smoke detector, the following factors must be considered. Air Flow Direction 4" Square back box, conduit and hardware }by others Testing/Maintenance Access Plate 1) The airflow present at the unit must be a representative sample of the air moving through the HVAC system (NOT in a dead spot ). The airflow must be between 0 ft/min. to 3,000 ft/min. To determine duct velocities for in-duct applications (shown top right), examine the engineering specifications that define the expected velocities or use an Alnor model 6000AP velocity meter (or equivalent). filter evaporator coil blower heat exchanger To determine fpm velocities in plenum spaces such as the return in a rooftop package unit (shown bottom right), divide the cfm velocity by the plenum space in square feet at the desired mounting location of the unit (multiply the linear foot measurement of height by the linear foot measurement of width). For example: 30 ton Package Unit puts out 12,000cfm 24in high x 30in wide = 2ft x 2.5ft = 5ft 2 12,000cfm 5 ft 2 plenum = 2,400 fpm return air in 2) To minimize the impact of air turbulence and stratification on performance, a duct smoke detector should be located as far as possible downstream from any obstruction (i.e. deflector plates, elbows, etc.). In all situations, confirmation of velocity within specifications is required. 3) Identify a code compliant location (supply or return side, or both) for the installation of the duct unit that will permit easy access for inspection and serviceability. 4) When installing on the return side, install duct units prior to the air being exhausted from the building or diluted with outside fresh air. supply compressor condenser coil 7) To prevent false alarms, the duct detector should not be mounted in areas of extreme high or low temperatures, in areas where high humidity exists, or in areas where the duct may contain gases or excessive dust. MOUNTING Remove the detector from its twist-in base. Remove the two mounting base plate-to-shroud screws. After securing the mounting base plate to the 4" square back box, wire the mounting base plate as appropriate. Re-assemble the shroud/detector base to the mounting base plate. Re-install the detector head. Proceed to testing. When mounted, it is critical that the smoke-sensor is situated such that the airstream flows through the head and not directly at the head (see below). 5) When installing duct smoke units downstream of filters, fires occurring in the filters will be detected, but if the filters become blocked, insufficient air flow through the duct unit will prevent the correct operation of the duct detector. Duct units installed in the supply air side may monitor upstream equipment and/or filters. 6) Where possible, install duct detectors upstream of air humidifiers and downstream of dehumidifiers. airflow airflow 2 INST AP-332 C100909

ELECTRICAL INSTALLATION TERMINAL AND POWER CONNECTIONS Prior to connecting input power to the duct unit, determine the correct input voltage/current availability and ensure it is connected to the correct terminals. CAUTION: Do not use looped wire under terminals. Break wire run to provide for proper supervision of connections. DRY CONTACT OUTPUTS ALARM FACP * Trouble contacts shown in normal unit energized state ALM - N.O. ALM - COM ALM - N.C. 8 9 10 10A @ 115 VAC * 16 17 18 18 19 19 TRB - COM TRB - N.C. ALM - COM ALM - COM ALM - N.O. ALM - N.O. t ro u b l e a l a r m 10 A @ 115 VAC 2.0A @ 30VDC HIGH VOLTAGE LOW VOLTAGE GND Ground to Back Box GND Ground to Back Box 24V 5 AC 24V 5 () N 1 Neutral H2 1 Neutral 0/N 4 AC 0/N 4 ( ) H 2 115V H1 2 3 230V 24VAC 50/60 HZ 0.2A MAX. 24VDC 0.1A MAX. 115VAC 50/60 HZ 0.1A MAX. 230VAC 50/60 HZ 0.1A MAX. REMOTE ACCESSORY OUTPUTS MSR-SERIES MS-SERIES CONNECTIONS SHOWN FOR ALL POSSIBLE TERMINAL STYLE CONFIGURATIONS. CONNECT ONLY THOSE TERMINALS AVAILABLE ON THE MSR REMOTE ACCESSORY CONTROL ASSEMBLY TB C AL P T/R 11 12 13 14 15 TB C AL P T/R 11 12 13 14 15 RED GREEN PILOT LED BLACK C 7 C 7 BLACK BLACK YELLOW TROUBLE LED RED BLACK N.O. TEST/RESET SWITCH TB C AL P T/R C MSR REMOTE RED ALARM LED RED BLACK AND/OR HORN HORN/STROBE MS REMOTE WIRING In the event of a fire alarm, certain equipment may be required to be shut down. For example, shut down may be achieved by interrupting the supply source to that particular piece of equipment when wired as indicated on Page 4. 3 INST AP-332 C100909

ALARM CONTACT USE EXAMPLE DAMPER SUPPLY SOURCE M FIRE ALARM CONTROL PANEL WIRING 10 9 8 NC COM NO ALARM In alarm 10 and 9 will open, interrupting voltage supply to damper causing it to close. SAMPLE CONTROL PANEL WIRING - STYLE D / CLASS A IDC (Supervised - A fault condition will not inhibit an alarm response) 16 17 16 17 UL Listed Conventional Fire Alarm Control Panel 19 19 18 18 19 19 18 18 SAMPLE CONTROL PANEL WIRING - STYLE B / CLASS B IDC (Supervised - A fault condition will not inhibit an alarm response) 16 17 16 17 UL Listed Conventional Fire Alarm Control Panel 19 19 18 18 19 19 18 18 EOL End of Line INTERCONNECTION WIRING FOR COMMON FUNCTIONS 13 13 13 12 12 12 INST AP-332 C100909 6 6 6 All alarm relays operate with single alarm. Individual horn/strobe units operate on alarmed detector only. 30 detectors max. 6 6 6 12 12 12 4 All alarm relays operate with single alarm. All horn/strobe units operate on any single alarm. 10 detectors max. NOTE: A common power supply must be used for all interconnected detectors. 15 15 15 Common test/reset. 30 detectors max. (Use normally open test/reset switch) 6 6 6 All alarm relays operate wiht single alarm. 30 detectors max.

TESTING AND MAINTENANCE PROCEDURES OPERATIONAL TESTING To determine the correct operation of the Series duct smoke detector, ensure input power is connected and the LED on the detector head of both the ionization and photoelectric models is flashing while the unit is in standby mode. The LED on the smoke detector head will be permanently illuminated when smoke is detected and the head is in alarm. CAUTION: DO NOT SPRAY GAS FOR MORE THAN ½ SECOND. OVERUSE OF TEST GAS FACILITY MAY RESULT IN DETECTOR CONTAMINATION. After 15 to 20 seconds the detector head will go into alarm, illuminating the detector head LED and causing the duct unit functions to operate, alarm relays will change state, and the alarm related remote accessories, if attached, will function. If no test gas is available to conduct functional testing, blow smoke from a cotton wick or punk directly at the head to cause an alarm. The alarm indicator should illuminate within one minute. Should additional testing also be required for simulated fire conditions, smoke bombs placed in the duct may not be suited for the particular detector head (photoelectric or ionization) selected and installed. Consult the smoke bomb data for proper use and compatibility with detector type. Above: The LED will be permanently illuminated when the unit is in alarm. Cause a detector alarm via magnet or smoke testing procedures detailed under functional testing below with the air handling unit shut down (not connected). The red alarm LED on the detector will be illuminated and the alarm relay outputs will change state. Using a multimeter set to OHMS (or continuity buzzer function on the meter) place the meter probes on the following terminals, and ensure the contacts are closed (continuity) (19-18) and (8-9). When removing the magnet or clearing the detector chamber of test gas and twisting the head loose manually and locking it back into position these contacts will again open and the unit will be back in the normal standby state. The trouble contacts (16,17) on the detector will not change state in the event of a fire alarm, operational, or functional testing. The trouble contacts can be tested by rotating the smoke detector head counter-clockwise or completely removing the detector head. This action will extinguish the flashing red LED and cause the trouble contacts to change state, and (16-17) will be open circuit. Replacing the detector head and rotating it clockwise until it locks will cause the red LED to be illuminated flashing and the unit will be operational; terminals (16-17) will be closed (continuity). FUNCTIONAL TESTING Once operational testing is concluded the unit requires functional testing to determine the correct operation of the detector head. MAGNET TESTING: Place the magnet provided with the installation kit on top of the shroud or detector head roughly opposite the LED. Allow at least five seconds for alarm initiation. Remove magnet and reset detector. SMOKE TESTING: Using smoke test canister with spray testing nozzle (available from Air Products and Controls Inc. part number TG-1000), spray the test gas into the detector. The S65A ionization detector head (55000-225) utilizes a radioactive source as its means of detection and will detect smoke particles of between.1 and 1 micron in size. The S65A photoelectric detector head (55000-328) operates on the principle of light scatter and will detect smoke particles of between 1 and 10 microns in size. When purchasing smoke bombs for additional required functional testing, ensure smoke particle sizes comply with the criteria as described above. NOTE: In situations that require a duct smoke detector to be held in an alarm condition for an extended period of time, the magnet test or smoke test methods should be used to ensure the detector is locked into alarm. MAINTENANCE Each installation location must be assessed on its own merits. If the protected area is of a very dirty nature then the duct unit(s) will have to be checked and cleaned on a quarterly basis or when cleaning is required. As a guideline the smoke detector head should be cleaned every six months or as required. The best methods of cleaning are to vacuum the detector head thoroughly or to blow the detector head out using clean, dry compressed air. Do not use chemicals or non-conforming air to clean the detector head housing as this could contaminate the detector head and damage the casing. Consult your local code and AHJ requirements for required maintenance schedules. 5 INST AP-332 C100909

AIR PRODUCTS AND CONTROLS AIR PRODUCTS AND CONTROLS INC. 25 Corporate Drive Auburn Hills, MI 48326 USA Telephone: (248) 332-3900 www.ap-c.com You in Control Technical Support: (888) 332-2241 AVAILABLE ACCESSORIES FOR USE WITH SERIES DUCT SMOKE DETECTORS MSR- SERIES REMOTE ACCESSORIES Visual Indicators: Alarm, Pilot, Trouble Buzzer: Programmable for Alarm and Trouble Buzzer Silence: Visual Notification and Ringback Test/Reset: Key Operated LED/Buzzer Test: Push-Button Operated MSR-100R/W White Face Plate MSR-100R/R Red Face Plate MSR-100R/S Stainless Steel Face Plate MSR-100RS/W/C White Face Plate; Strobe with Clear Lens MSR-100RS/W/O White Face Plate; Strobe with Opaque Lens MSR-100RS/R/C Red Face Plate; Strobe with Clear Lens MSR-100RS/R/O Red Face Plate; Strobe with Opaque Lens MSR-100RS/S/C Stainless Steel Face Plate; Strobe with Clear Lens MSR-100RS/S/O Stainless Steel Face Plate; Strobe with Opaque Lens MS- and SHP- SERIES REMOTE ACCESSORIES MS-RA Remote Alarm MS-RA/R Remote Alarm, push button Test/Reset Switch MS-RA/P/R Remote Alarm, Pilot, push-button Test/Reset Switch MS-KA/R Remote Alarm, key-operated Test/Switch MS-KA/P/R Remote Alarm, Pilot, key-operated Test/Reset Switch MS-RA/P Remote Alarm, Pilot MS-RH Remote Alarm Horn MS-RH/KA/P/R Remote Alarm, Pilot, Horn, key-operated Test/Reset Switch MS-RH/P/A Remote Alarm, Pilot, Horn MS-RH/KA/P/A/T Remote Alarm, Trouble, Pilot, Horn, key-operated Test/Reset Switch MS-RA/P/T Remote Pilot, Trouble MS-RA/FT/P Remote Pilot, Trouble, push-button Test/Reset Switch MS-KA/P/R/T Remote Pilot, Trouble, key-operated Test/Reset Switch MS-RD Remote Alarm MS-F/T Remote Trouble SHP24-1575R Horn/Strobe, red housing, clear cover SHP24-1575O Horn/Strobe, white housing, opaque cover SHP24-1575W Horn/Strobe, white housing, clear cover SMOKE TEST GAS TG-1000 Solo Aerosol Test Gas with Spray Nozzle REPLACEMENT SMOKE DETECTOR HEADS 55000-225 S65 Ionization Replacement Head 55000-328 S65 Photoelectric Replacement Head POWER SUPPLIES T-PB 202-1 24VAC @ 4.0A Class I Power Supply T-PB 202-0 24VAC @ 4.0A Class I Power Supply T-PB 303-1 24VAC @ 3.0A Class I Power Supply T-PB 303-0 24VAC @ 3.0A Class I Power Supply AIR PRODUCTS AND CONTROLS SERIES PLENUM/DUCT SMOKE DETECTORS You in Control NO-FLOW LOW-FLOW SPECIAL APPLICATION INSTALLATION AND MAINTENANCE INSTRUCTIONS -N 4-Wire, Ionization Type -P 4-Wire, Photoelectric Type NOTICE: The information contained in this document is the most current available at the time of shipment of accompanying product, and is subject to change without notice. Future references should always be made to the most current revision of this document. The information contained in all this document should be considered before installing or using the product. Any example applications shown are subject to the most current enforced local/national codes, standards, approvals, certifications, and/or the authority having jurisdiction. All of these resources, as well as the specific manufacturer of any shown or mentioned related equipment, should be consulted prior to any implementation. For further information or assistance concerning this product, contact Air Products and Controls Inc. Air Products and Controls Inc. reserves the right to change any and all documentation without notice. Air Products and Controls Inc. 2006 A COPY OF THESE INSTRUCTIONS SHOULD BE LEFT WITH THE EQUIPMENT UNTIL INSTALLATION BY ALL TRADES IS FULLY COMPLETE. FOLLOWING FINAL INSPECTION, A COPY SHOULD BE LEFT WITH THE OWNER/USER. FOR TECHNICAL SUPPORT CALL TOLL FREE 888-332-2241 OR 248-332-3900