FC330A-ECO1 Auto-addressing analogue 1-Loop fire detection panel

Similar documents
FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel

FC700A Fire detection control unit

FC724 Fire control panel

FC722 Fire control panel

FC723 Fire control panel

FC724 Fire control panel

FC722 Fire control panel

Synova TM product catalog.

FC2020 Fire control panel

Fire control panels FC726 FC726-XA

Sinteso TM product catalog.

FC2040. Fire control panel. Sinteso. FS20 series, MP6

Fire control panels FC360

Fire control panel for modernization

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

FS20 Fire detection system

DC1136, DC1131-AA, DC1134-AA, DC1136-AA Input / Output modules

Fire control panel detect 3004 plus and accessories

Fire Detection Systems Product Catalogue (Version )

Advanced FireAlarm Panel 1-4Loop

DC1192 Input /Output module

Building Technologies

Intelligent addressable fire alarm control panel

On the job around the clock 24/7: Fire detection systems

ZXSe Range Data Sheet

Touch Screen 1 loop Addressable Fire Alarm Panel

SUPREMATouch. Modular Fire & Gas Detection System

SUPREMATouch. Modular Fire & Gas Detection System

XC10 Extinguishing control panels

OOH740, OOHC740. Cerberus PRO. Automatic fire detectors

ZXSe Range. Fire Safety. Analogue addressable fire alarm control panel KEY FEATURES. Panel Features

ZIOU/230 - MAINS IO INSTRUCTION MANUAL

Intelligent Addressable Fire Alarm System

TECHNICAL DATA SHEET ADDRESSABLE FIRE ALARM SYSTEMS FIRE ALARM CONTROL PANEL LF-6100 A 1/2

OOH740, OOHC740 Automatic fire detectors

For Complete Fire and Gas Solutions

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

Bionics Instrument. Alarm Handling. Gas Alarm Systems

Input module, input/output modules

Cerberus FIT conventional system

Interface and EOL Modules 8

CODESEC FIRE ALARM SYSTEMS. security technologies

IQ8Control C Fire Alarm Panel

The EN54 Part 2 & 4 Fire System

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

UEZ 2000/1 LSN, UEZ 2000 LSN, Intrusion Control Centers

Fire Extinguishing Control Panel INSTRUCTION MANUAL. Revision 8/ Instruction Manual Page 1 Revision 8/01.17 of 63

The EN54 Part 2, 4 and 13 Fire System

Cerberus TM PRO Fire Safety System A comprehensive fire-protection system

DBS721, DBS729 Sounder interbase, Sounder beacon interbase

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

DB110xA, DB1131A, SO620A, DB1151A Detector bases and accessories

OH720, OP720, HI720, HI722

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

IGD.CO.UK

Entwicklung + Fertigung + Service: Heerweg 15 D, Denkendorf Tel.: / Fax.: /

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

Solution F2. Fire Alarm Control Panels one step ahead.

Multi line separator module

Cerberus PRO A comprehensive fire-protection system

Planning Instructions MEW01776 Revision -

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Phone: Fax:

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

C E R T I F I C AT LPCB I O N B O A R D P R E V E N T L O S S. Cooper Fire Systems

PEGAsys. Multi-Loop Intelligent Suppression Control System FEATURES DESCRIPTION. Effective: March 2007 K

FDCIO223 (ES 45) Transponder

MINERVA. Marine. Fire Detection. MX T2000 Panel Range. Features: MINERVA Marine Panel Range

ID2000. intelligent fire alarm panel

OOH740-A9-Ex Multisensor fire detector

OOH740-A9-Ex Multi-sensor fire detector

STANDARD TECHNICAL SPECIFICATION FOR AN ANALOGUE ADDRESSABLE FIRE DETECTION SYSTEM

CONVENTIONAL FIRE ALARM CONTROL UNITS. MR-2300 SERIES Fire Alarm Control Units MEA

Vigilant MX4428 Fire Alarm System

XC10 combined fire detection and extinguishing control

MK8000 OPC Server Interface Specification for CS1115 Building Technologies

Input module, input/output module

Conventional Releasing Control Panel

Planning Instructions MEW01090 Revision 4

561-MB256 plus. Intruder alarm control panel. Performance features

Building Technologies SIGMASYS M Multifunctional danger alarm control and indicating panel

FDOOT241-9, FDOOT241-A, FDO241, FDT241

DC1154 / DC1154-AA / DC1156-AA / DC1157-AA Input / Output modules

CONVENTIONAL FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels MEA. Features. Description

Desigo TM Fire Safety System A comprehensive fire-protection system

Instructions for the fan motor control system with integrated wiring terminals SILVER C

Excel-EN Conventional Fire Control Panel

GE Security. FP1200, FP2000 and KSA1200 series fire panels, repeaters and emulators Interconnection and wiring

DUAL MONITORED INPUT/OUTPUT UNIT BN-305

Intelligent Single Loop Fire Alarm Control Panel

FDCL221-M Multi line separator module

Desigo TM Fire Safety System A comprehensive fire-protection system

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

PERTRONIC INDUSTRIES LTD F4-RMAX Installation Note

REPEATER FS5200R INSTRUCTION MANUAL

M2500 Engine Controller Installation Manual

Intelligent 2 & 4 Loop Fire Alarm Control Panels

FEC400 Series. Installation Manual

Multi-Gas-Controller MGC2

IntelliKnight 5820XL Addressable Fire Alarm Control System Sales Guide

System 57. An advanced World of intelligent gas detection system management

Transcription:

FC330A-ECO1 Auto-addressing analogue 1-Loop fire detection panel Synova Commissioning in no time thanks to automatic address allocation Auto-addressing makes setting dip switches, punch cards, etc. unnecessary Automatic localizing of interruptions & shorts Unshielded cables prevent irksome ground-returns Periodic self-test facility Serial interface for third-party building management systems, repeaters, printer, etc. Additional cards may be retrofitted at anytime for customized solutions Maintenance can be tailored to customer needs

Features Synova FC330A-ECO1 has all the requirements for intelligent systems. Addressing is automatic and address allocation takes only seconds. To improve security and increase speed, distributed intelligence enables detectors to verify danger signals independently. Product features 128 addressable Synova fire detectors, regardless of type, may be connected to the Synova FC330A-ECO1 fire detection panel. Commissioning, which comprises auto-addressing of all connected elements, is executed by the intelligent SynoLOOP transmission protocol. Time-consuming preparatory work such as setting dip switches, punch cards, etc., is no longer necessary, providing reliable on-time commissioning. Siemens equips all auto-addressable elements with isolating links so they do not require individual resetting. If a short circuit occurs, the panel localizes and isolates the defective cable section. The loop system permits data flow in both directions up to the error source, with optimum safety. Thanks to automatic isolation, planning or adapting detector groups or fire sections to changing needs is more convenient. Expansion with various additional cards opens the door to almost unlimited customized solutions. Control panel FC330A-ECO1 and its many options SynoLOOP SynoLINE300 LON-bus 2

FC330A-ECO1 (one-loop) and its expansions [8] Z3B171 Relay module [1] FC330A-ECO1 Control panel, 1 loop Position C (up to 4 Z3B171) [2] Z3S030 Z3S020 [3] K3X030 Master board One RS232 port [4] Z3G280 Mounting plate (up to 2 cards) [7] K3I080 RS232/LON-Bus converter or [5] K3G050 Relay card [6] K3L070 VdS interface card 3

FC330A-ECO1 (one-loop) and its expansions (continued) [1] Fire detection panel FC330A-ECO1 The FC330A-ECO1 fire detection panel accommodates: Smoke, heat and multi-sensor detectors and manual call points from different series Special detectors (flame detectors, highly sensitive detectors) for special applications Input and output modules Siren outputs Fire detection panel FC330A-ECO1 is equipped with state-of-the-art software, virtually unlimited range of applications may be programmed easily. It provides: Intuitive, menu-driven operation 128 free definable detector groups Dual-detector independence Chronological storage and retrieval of up to 200 events Windows-based software tool for parameter programming, etc. [2] Access with key Z3S030/Z3S020 The system operator may access the fire detection system in three ways: by password, without a password, or with a key. Two kinds of key switches are available: Module Z3S030 is integrated in an existing like-key concept Module Z3S020 follows the Nordic fire brigade concept [3] SynoLOOP master board K3X030 The master board is the basic control panel module and is part of its basic equipment. Switched on, the master board recognises all connected elements and is ready to transmit fire alarms. One auto-addressable loop with 128 devices (or one stub line with 32 addressable detectors). The master board has in addition the built in: 8 programmable control outputs 2 supervised horn outputs Alarm and fault relays 4 progammable inputs 4 LEDs activated via external inputs The RS232 interface accommodate alternatively various applications: System programming Printer connection for event protocol printouts LON-bus connection Incorporation in a building management system (BMS) Connection of the visualiser training tool, to operate the FC330AECO1 via your PC. [4] Mounting plate Z3G280 The mounting plate is needed to connect up to two expansion cards, to be mounted over the master board K3X030. The cards may be mounted either vertical or horizontal. [5] Relay card K3G050 The relay card K3G050 triggers fire controls such as activation of fire doors or air vents. It offers additionally the following outputs: 8 relay switch contacts (max. 30VDC / 2A) 4 programmable outputs (24VDC / 48mA) 2 supervised outputs (sirens, 24VDC / 500mA) 1 plug is available for the relay card or the VdS card [6] VdS Interface Card K3L070 This card is only needed, when VdS peripherals are specified. The card contains the fire service key box adapter. It also permits the connection to a fire brigade operating panel or a transmission device. A standard extinguishing interface is provided. One plug is provided for the VdS card or the relay card (K3G050). [7] LON-bus converter card K3I080 The K3I080 LON-bus converter card is used to connect to the control panel with various LON-bus applications: Floor repeater panels Mimic panels LED parallel indications Various signal in and output possibilities Converter cards on the LON-bus make numerous user-oriented solutions possible. For instance, up to 16 floor repeater panels may be connected to the LON bus and up to 256 addresses can be managed for max. 9216 LED displays. The LON-bus converter card is built directly into the control panel and connected to the RS232 serial output. For more information consult the data sheet 007349. [8] Relay module Z3B171 The relay module (250VAC / 10A) is an additional control module, activated by the control panel's control outputs. Up to 4 relay modules may be connected to the FC330A-ECO1. Programmable key A key on the key pad can serve as additional input. The key may be programmed for various functions (e.g. lamp test). It can be easely connected via the F02F290 to the masterboard K3X030. 4

System overview Alarm devices DBZ OH HI OP AI DM DF addressable Alarm reception centre (Fire brigade) 1 SynoLOOP max. 128 devices ABI EB AB CB DC DC DC DC Ventilation, Air cond. system, Elevator OH HI OP SynoLINE300 HI OP SynoLINE600 DLO SB DO-Ex DT-Ex DF-Ex SynoLINE600-Ex FBF FSD ÜE Fire control installations (FCI) VdS periphery: - Fire brigade control panel - Fire brigade key cabinet - Remote transmission unit One RS232 serial interface Building management system LON-Bus via LON interface Printer Control in/output modules LON/Synoptic converter Databus Floor repeater panels Parallel indicators or Synoptic / relay Configuration tool SWE330A Training 5

Technical data 400mm 110 19 Rack Type K3X030 K3G050 K3I080 K3L070 Z3B171 Current consumption for FC330A-ECO1 and expansions Normal operation Alarm condition 100mA 1) 20mA 10mA 12mA 0mA +9mA 2) +9mA 2) 0mA 3) +40mA +27mA 1) 0.2mA normal operation current consumption per addressable device connected 2) Per activated contact/control line/buzzer, without external load (sounders, etc.) 3) LON-devices see document 007349 Programmable outputs 8 x 24VDC / 40mA + 4 optional Relay output for transmission 2 x 30VDC / 1A Supervised outputs 2 x 24VDC / 500mA + 2 optional Programmable inputs 4 Programmable key input 1 Programmable fire zones 128 Programmable control zones 128 Line resistance addressable loop 150Ohm / 300nF Mains 115 / 230VAC +10% / 15%, 50 / 60Hz Power consumption < 50VA Battery 2 x 12V / 12Ah Standards EN54-2, IEC721-3-3 / 3K5 Colour light grey ( RAL 7035) Approvals VdS Nr. G298015, LPCB, a.m.m. Z3G290 (needs 10 rack units) * * 1 rack unit = 44.4mm Reference documents Doc. no.1583 Synova FC330A Planning, Installation, Commissioning, Operating Programming, Trouble Shooting, Maintenance Doc. no. 1973 Synova FC330A Operating Manual, System Operation for User Doc. no. 1923 Synova FC330A Remote indicating & Control devices, Logging Printer (Installation & Commissioning) Doc. no. 007349 LON-Bus Data Sheet Details for ordering Type Part no Designation Weight FC330A-ECO1 543716 Control panel 1 Loop analogue auto-addressing 8.000 kg FCA105 576013 Language kit (International English) 0.040 kg Z3S020 484082 Key switch module «Nordic access key» 0.140 kg Z3S030 484095 Key switch module «like-keyed» 0.140 kg Z3B171 484383 Relay module with 1 contact 250VAC/10A 0.040 kg F02F290 513762 Connecting ribbon cable for optional key 0.210 kg TKU2 230508 Surveillance contact 0.019 kg Z3G290 566159 Adapter set 19 2.400 kg Expansion cards Z3G280 566146 Mounting plate for expansion cards 0.500 kg K3G050 512970 Relay card 0.254 kg K3L070 523820 VdS-interface card D 0.330kg K3I080 504768 RS232 / LON-bus converter 0.325 kg AG Alte Landstr. 411 CH-8708 Männedorf Tel. +41 1-922 6111 Fax +41 1-922 6450 www.sbt.siemens.com 2003 Copyright by AG Data and design subject to change without notice. Supply subject to availability. Document no. 007397_b_en_-- Manual FD-C Edition 12.2003 Section 8