FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel

Similar documents
FC330A-ECO1 Auto-addressing analogue 1-Loop fire detection panel

FC700A Fire detection control unit

FC724 Fire control panel

FC722 Fire control panel

FC724 Fire control panel

Synova TM product catalog.

FC723 Fire control panel

FC722 Fire control panel

FC2020 Fire control panel

Fire control panels FC726 FC726-XA

Sinteso TM product catalog.

Fire control panels FC360

FC2040. Fire control panel. Sinteso. FS20 series, MP6

Fire control panel for modernization

FS20 Fire detection system

DC1192 Input /Output module

DB110xA, DB1131A, SO620A, DB1151A Detector bases and accessories

Input module, input/output modules

XC10 Extinguishing control panels

Building Technologies

OOH740, OOHC740. Cerberus PRO. Automatic fire detectors

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

OOH740, OOHC740 Automatic fire detectors

DBS721, DBS729 Sounder interbase, Sounder beacon interbase

DC1154 / DC1154-AA / DC1156-AA / DC1157-AA Input / Output modules

FDCL221-M Multi line separator module

FDCIO223 (ES 45) Transponder

Cerberus FIT conventional system

MK8000 OPC Server Interface Specification for CS1115 Building Technologies

DC1136, DC1131-AA, DC1134-AA, DC1136-AA Input / Output modules

Advanced FireAlarm Panel 1-4Loop

Input module, input/output module

Multi line separator module

OOH740-A9-Ex Multisensor fire detector

OH720, OP720, HI720, HI722

OOH740-A9-Ex Multi-sensor fire detector

Fire control panel detect 3004 plus and accessories

Fire Detection Systems Product Catalogue (Version )

Intelligent addressable fire alarm control panel

Output module (230 V)

Manual call points. Sinteso / Cerberus PRO FDM225, FDM226

FDOOT241-9, FDOOT241-A, FDO241, FDT241

FDCL221-Ex Line adapter (Ex)

13 tones to choose from, 2 programmable alarm levels Adjustable sound levels up to 93 dba

UEZ 2000/1 LSN, UEZ 2000 LSN, Intrusion Control Centers

FDF Sinteso Cerberus PRO Cerberus FIT. Flame detector. Flame detector addressed or collective, ASAtechnology TM

FDS229-R / FDS229-A Alarm sounder with supplementary optical indication

ZIOU/230 - MAINS IO INSTRUCTION MANUAL

ASA linear smoke detector

On the job around the clock 24/7: Fire detection systems

ZXSe Range Data Sheet

FDCW221 / DOW1171 / SMF121 SMF6120 (repair/replacement) Radio fire detection system

Touch Screen 1 loop Addressable Fire Alarm Panel

XC10 combined fire detection and extinguishing control

DF1101-Ex Infrared flame detector

FT2080 Fire terminal (Touch) Mounting Installation

FT2080 Fire terminal (Touch) Mounting Installation

Building Technologies. FDUL221 en Line tester operating instructions for electricians

Fire Extinguishing Control Panel INSTRUCTION MANUAL. Revision 8/ Instruction Manual Page 1 Revision 8/01.17 of 63

FDOOT241-A9-Ex Multisensor fire detector

Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation

Intelligent Addressable Fire Alarm System

DM1101 / DM1103 / DM1104 DM1103-L / DM1103-S Manual call points Manual release button and emergency stop button

DT1101A / DT1102A / DO110xA Automatic fire detectors

SUPREMATouch. Modular Fire & Gas Detection System

The EN54 Part 2 & 4 Fire System

ZXSe Range. Fire Safety. Analogue addressable fire alarm control panel KEY FEATURES. Panel Features

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

Solution F2. Fire Alarm Control Panels one step ahead.

Bionics Instrument. Alarm Handling. Gas Alarm Systems

SUPREMATouch. Modular Fire & Gas Detection System

For Complete Fire and Gas Solutions

Manual call point. Sinteso Cerberus PRO FDM223H, FDM224H. 'Heavy Duty' manual call point addressed (FDnet/C-NET)

IGD.CO.UK

2015 NEW. Cerberus ECO. enjoy protecting. Product Brouchure. siemens.com/buildingtechnologies

Call stations and extensions

Interface and EOL Modules 8

Cerberus TM PRO Fire Safety System A comprehensive fire-protection system

Mimic display driver, LED ribbon cable

TECHNICAL DATA SHEET ADDRESSABLE FIRE ALARM SYSTEMS FIRE ALARM CONTROL PANEL LF-6100 A 1/2

Fire safety products and accessories siemens.com/cerberus

Cerberus PRO A comprehensive fire-protection system

DM1131 / DM1133 / DM1134 Manual call points

DF1151-Ex Infrared flame detector

Planning Instructions MEW01776 Revision -

CODESEC FIRE ALARM SYSTEMS. security technologies

FDCW241 Radio gateway Mounting

FDOOT221, FDO221, FDT221

IQ8Control C Fire Alarm Panel

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

Multi-Gas-Controller MGC2

561-MB256 plus. Intruder alarm control panel. Performance features

Vigilant MX4428 Fire Alarm System

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

Entwicklung + Fertigung + Service: Heerweg 15 D, Denkendorf Tel.: / Fax.: /

The EN54 Part 2, 4 and 13 Fire System

FDA241, FDA221 Siemens ASD

Building Technologies

XC10 combined fire detection and extinguishing control

Reliably Advanced Extinguishing Control

Transcription:

FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel Synova TM Commissioning in no time thanks to automatic address allocation Auto-addressing makes setting dip switches unnecessary Automatic localizing of interruptions & shorts Unshielded cables prevent irksome ground-returns Periodic self-test facility Serial interface for third-party building management systems, repeaters, printer, etc. Additional cards may be retrofitted at anytime for customized solutions Maintenance can be tailored to customer needs

Features The FC330A-ECO has all the requirements for intelligent systems. Addressing is automatic and address allocation takes only seconds. To improve security and increase speed, distributed intelligence enables detectors to verify danger signals independently. 128 addressable Synova fire detectors, regardless of type, may be connected to the FC330A-ECO fire detection panel. Commissioning, which comprises auto-addressing of all connected elements, is executed by the intelligent SynoLOOP transmission protocol. Time-consuming preparatory work such as setting dip switches etc., is no longer necessary, providing reliable ontime commissioning. Siemens equips all auto-addressable elements with isolating links so they do not require individual resetting. If a short circuit occurs, the panel localizes and isolates the defective cable section. The loop system permits data flow in both directions up to the error source, with optimum safety. Thanks to automatic isolation, planning or adapting detector groups or fire sections to changing needs is more convenient. Expansion with various additional cards opens the door to almost unlimited customized solutions. System overview B3Q580, B3Q590, B3Q595 Floor repeater panels B3R051 Parallel indicators Mimic panel 2

FC330A-ECO and its expansions 3

FC330A-ECO and its expansions (continued) [1] Fire detection panel FC330A- ECO The FC330A-ECO fire detection panel accommodates: Smoke, heat and multi-sensor detectors and manual call points from different series Special detectors (flame detectors, highly sensitive detectors) for special applications Input and output modules Siren outputs Fire detection panel FC330A-ECO is equipped with state-of-the-art software; virtually unlimited range of applications may be programmed easily. It provides: Intuitive, menu-driven operation 128 free definable detector groups Dual-detector independence Chronological storage and retrieval of up to 200 events Windows-based software tool for parameter programming, etc. [2] Access with key Z3S030/Z3S020 The system operator may access the fire detection system in three ways: by password, without a password, or with a key. Two kinds of key switches are available: Module Z3S030 is integrated in an existing like-key concept Module Z3S020 follows the Nordic fire brigade concept [3] SynoLOOP master board K3X030 The master board is the basic control panel module and is part of its basic equipment. Switched on, the master board recognizes all connected elements and is ready to transmit fire alarms. One auto-addressable loop with 128 devices (or one stub line with 32 addressable detectors). The master board has in addition the built in: 8 programmable control outputs 2 supervised horn outputs 2 Alarm and fault relays 4 programmable inputs 4 LEDs activated via external inputs The RS232 interface accommodate alternatively various applications: System programming Printer connection for event protocol printouts LON-bus connection Incorporation in a building management system (BMS) Connection of the Visualizer training tool, to operate the FC330A-ECO via your PC. [4] Mounting plate Z3G280 The mounting plate is needed to connect up to two expansion cards, to be mounted over the master board K3X030. The cards may be mounted either vertical or horizontal. [5] Relay card K3G050 The relay card K3G050 triggers fire controls such as activation of fire doors or air vents. It offers additionally the following outputs: 8 relay switch contacts (max. 30 VDC / 2 A) 4 programmable outputs (24 VDC, 48 ma) 2 supervised outputs (sirens, 24 VDC, 500 ma) One plug is provided for the K3G050 or for the K3L070. [6] VdS Interface Card K3L070 This card is only needed, when VdS peripherals are specified. The card contains the fire service key box adapter. It also permits the connection to a fire brigade operating panel or a transmission device. A standard extinguishing interface is provided. One plug is provided for the K3L070 or for the K3G050. [7] LON-bus converter card K3I080 The K3I080 LON-bus converter card is used to connect to the control panel with various LON-bus applications: Floor repeater panels Mimic panels LED parallel indications Various signal in and output possibilities Converter cards on the LON-bus make numerous user-oriented solutions possible. For instance, up to 16 floor repeater panels may be connected to the LON bus and up to 256 addresses can be managed for max. 9216 LED displays. The LON-bus converter card is built directly into the control panel and connected to the RS232 serial output. For more information consult the data sheet 007349. [8] Relay module Z3B171 The relay module (250 VDC, 10 A) is an additional control module, activated by the control panel's control outputs. Up to 4 relay modules may be connected to the FC330A-ECO. Programmable key A key on the key pad can serve as additional input. The key may be programmed for various functions (e.g. lamp test). It can be easily connected via the F02F290 to the master board K3X030. 4

Detailed system overview AI DM DF DBZ OH HI OP addressable 1 SynoLOOP max. 128 devices ABI EB AB CB DC DC DC DC Alarm devices Alarm reception centre (Fire brigade) Fire control installations (FCI) Ventilation, Air cond. system, Elevator OH HI OP SynoLINE300 HI OP SynoLINE600 DLO SB DO-Ex DT-Ex DF-Ex FBF FSD ÜE VdS periphery: - Fire brigade control panel - Fire brigade key cabinet - Remote transmission unit SynoLINE600-Ex One RS232 serial interface Building management system LON-Bus via LON interface Printer Control in/output modules LON/Synoptic converter Databus Floor repeater panels Parallel indicators or Synoptic / relay Configuration tool SWE330A Training 5

Dimensions 19 housing 110 19 400 400 Z3G290 (needs 10 rack units) 1 rack unit = 44.45 mm 6

Technical data Type K3X030 K3G050 K3I080 K3L070 Z3B171 Current consumption for FC330A-ECO and expansions Operation current Alarm current 100 ma 1) +9 ma 2) 20 ma +9 ma 2) 10 ma 0 ma 3) 12 ma +40 ma 1) 0.2 ma normal operation current consumption per addressable device connected 2) Per activated contact/control line/buzzer, without external load (sounders, etc.) 3) LON-devices see document 007349 Detector loop (SynoLOOP) 1 Programmable outputs 8 x 24 VDC / 48 ma + 4 optional Relay output for transmission 2 x 30 VDC / 1 A Supervised outputs 2 x 24 VDC / 500 ma + 2 optional Programmable inputs 4 Programmable key input 1 Programmable fire zones 128 Programmable control zones 128 Line resistance addressable 150 Ohm / 300 nf loop Supply voltage 115/230 VAC ±15 % (VdS: +10 %) 50... 60 Hz Power consumption max. 50 VA Battery 2 x 12 V / 12 Ah Standards EN54-2, EN54-4 Color light grey, RAL 7035 Operating temperature 0 +50 C Humidity 95 % rel. Protection category IP40 Approvals VdS LPCB G298015 126h/03 0 ma +27 ma Reference documents Doc. no.1583 Synova TM FC330A Fire detection system (Planning, Installation, Commissioning, System operating, User application settings, Background information, Trouble shooting, Maintenance, Appendix) Doc. no. 1923 Synova TM FC330A Remote indicating & Control devices, Logging Printer (Installation & Commissioning). Doc. no. 1973 Synova TM FC330A Operating Doc. no. 007349 LON-Bus Data Sheet 7

Details for ordering Type Part no Designation Weight Control unit FC330A-ECO 5437160001 Control panel 1 Loop analogue autoaddressing 8.000 kg FC330A-ECO-CH 5775750001 Control panel 1 Loop analogue autoaddressing including accessories for CH incl. inscription stripes 8.000 kg Accessories FCA.. Accessory set (EPROM, inscription stripes) 0.040 kg available languages see document 1583 Z3S020 4840820001 Key switch module Nordic access key 0.140 kg Z3S030 4840950001 Key switch module like-keyed 0.140 kg Z3B171 4843830001 Relay module with 1 contact 250 VAC, 10 A 0.040 kg F02F290 5137620001 Connecting ribbon cable for optional key 0.210 kg TKU2 2305080001 Surveillance contact 0.019 kg Z3G290 5661590001 Adapter set 19 2.400 kg Expansion Z3G280 5661460001 Mounting plate for expansion cards 0.500 kg K3G050 5129700001 Relay card 0.254 kg K3L070 5238200001 VdS-interface card D 0.330kg K3I080 5047680001 RS232/LON-bus converter 0.325 kg Siemens Switzerland Ltd Group International Headquarters Gubelstrasse 22 CH-6301 Zug Tel. +41 41 724 24 24 Fax +41 41 724 35 22 www.sbt.siemens.com 2007 Copyright by Siemens Switzerland Ltd Data and design subject to change without notice. Supply subject to availability. Document no. 007397_d_en_-- Manual FD-C Edition 04.2007 Section 8