Drying ovens, incubators, cooled incubators

Made in Poland. Established POL-EKO-APARATURA. products. Your partner in laboratory analysis and technological processes

Table of contents. Table of contents. Development history THERMOSTATIC EQUIPMENT. Cooled incubators (ST) Laboratory refrigerators. Laboratory freezers

Laboratory thermostatic chambers

Incubators, cooled incubators, drying ovens, sterilizers, climatic chambers

ZL Laboratory freezers

Medical Air circulated Refrigerator TC (2 independent temperature ranges), also in accordance with DIN 58345

Plasma Freezer with air circulation TC 516 acc. to DIN 58375

Laboratory Deep Freeze Storage Cabinet TC 230 Air circulated

Constant climate chambers

Laboratory Air circulated Refrigerator/Deep Freezer TC Two-door (2 independent temperature ranges)

Constant climate chambers

External Dimensions: B = 600 mm D = 630 mm H = 2000 mm. Internal Dimensions: B = 451 mm D = 430 mm H = 1598 mm

Stability Chambers & Rooms

Constant climate chamber with ICH-compliant illumination

Constant climate chambers

External Dimensions: B = 750 mm D = 700 mm H = 2100 mm. Internal Dimensions: B = 600 mm D = 580 mm H = 1270 mm. Temperaturerange: 2 C to 20 C

Chromatographic Air circulated Refrigerator, two-door TC 603

DOUBLE DOOR FREEZER.

ICH110. Climate Chamber. Product specification

ICH750L. Climate Chamber. Product specification

Constant climate chamber with humidity

ICH260C. Climate Chamber. Product specification

ICP450. Compressor-cooled incubator. Product specification

ENVIRONMENT FRIENDLY CLIMATIC CHAMBER

OPERATING INSTRUCTIONS. G214 Software - Version 4

Sunrise the beginning of a brand new day

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

Laboratory Refrigerator/Deep Freezer TC 802

Environmental simulation chamber for complex alternating climate profiles

FITOCLIMA 600 & 1200 PHARMA

NC SERIES. Bench Top Steam Sterilizers

Walk in Freezer. Comfortable work environment

STABILITY. Stability Storage Chambers & Environmental Stability Rooms

STABILITY ICH. ICH Stability Tests

VWR INCU-Line Peltier Cooled Incubators. Instruction Manual

Ultra low temperature freezers for long-term storage at -86 C UF V 500, UF V 700

FITOCLIMA 600 & 1200 STABILITY

FITOCLIMA 600 & 1200 STABILITY

Chromatographic Air circulated Refrigerator, two-door TC 603

Caution: Before using the device first read carefully this manual!

Stability Studies? Walk in Stability Chamber BUY RENT SERVICE. Thermolab is a one stop solution for all your stability requirements

Floor model Freeze Dryer

OT SERIES. Bench Top Steam Sterilizers

AZTECA A LITRE STERILISER

WR-KWAP (Platelet incubator/agitator) HPL

REFRIGERATOR M E D I C A L.

Stability & Shelf Life

laboratory & sterilization technology

ECL Comfort 210 controller, Remote Control Units ECA 30 / 31 and Application keys Designed in Denmark

Best Freeze Drying Solutions

& Freezers. Selection Guide. Laboratory Refrigerators & Freezers. Accessories & Options

ECL Comfort 210 controller, Remote Control Units ECA 30 / 31 and Application keys

Climate chambers with illumination and humidity The BINDER KBWF series shines with its

laboratory & sterilization technology

Drying and heating chambers

ULTRA.GUARD ultra low temperature freezer

Internet. Climate rating definitions. Customer service.

Ultra low temperature freezers -40 C and -86 C. NEXUS Series

Constant climate chambers

Instruction Manual. DRY-Line DL 56 Prime: DL 112 Prime: DL 180 Prime:

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

PR / MP I Laboratory / Medicine

Photo Stability Chamber

Biomedical Freezer 37 38

NC 100. Vertical Steam Sterilizer

TCC-34. Features: TISSUE CULTURE

Technical Description. Laboratory Climate Test Chamber. System Weiss. Mat. No.: Type WKL 34/40

Thermo Scientific Revco UxF -80C Series Upright ULT Freezers

PowerWizard Range. Digital Control Systems & Remote Communication Options. PowerWizard Providing Safe Control of Your.

i.c³ User Guide For Helmer i.series Ultra-Low Freezers A/A

Epsilon 1-4 LSCplus Epsilon 2-4 LSCplus

Multi-Lab REFRIGERATORS Frigidere medicale

User manual for reversible heat pump


Model KBF 240 Constant climate chambers with large temperature / humidity range

FDL-10N-50-Series, Bench Top Freeze Dryers

Industrial Freezer Sales A division of IDS 5311 Derry Avenue Building D Agoura Hills CA Phone (818) Fax (818)

SPC-56 SHORT PLANT.

TESTING FITOTERM FITOCLIMA TEMPERATURE / HUMIDITY REACH-IN CHAMBERS FOR ENVIRONMENTAL TESTING

Model CB 220 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

EC 160 CO 2. Incubator

Model KBWF 240 Growth chambers with light and humidity

Ultra low temperature freezers -45 o C & -86 o C Upright & Chest 370 to 830 liter

Thermo Scientific Forma Environmental Chambers. Controlled Temperature Storage Solutions

TCR. Features: TISSUE CULTURE

Heated and Refrigerated Incubators

Igloo. Ultra low temperature freezers -45 o C & -86 o C Upright & Chest 370 to 830 liter

UMWELTSIMULATION TEMPERATUR VARIO. Walk-in chambers in modular design for multifunctional applications in different industrial fields

Ultra Low Freezers. Blood Management Solutions. B Medical Systems U Range

FITOCLIMA ECV45 / ECV75 TEMPERATURE & HUMIDITY TEST CHAMBER INTEGRATION WITH ELECTRO-DYNAMIC SHAKER

GE Security. FP1200, FP2000 and KSA1200 series fire panels, repeaters and emulators Interconnection and wiring

Constant climate chambers

Digital Control Systems & Remote Communications Options

CLIMATIC TEST CHAMBER CTC / TEMPERATURE TEST CHAMBER TTC 100 % AtmoSAFE: In Memmert environmental

Refrigerators and freezers Research and laboratory 2018

Application description

FREEZE DRYER LYOPHILIZER PRODUCTS LABFREEZ INSTRUMENTS CO., LTD

A660 Air Conditioning Laboratory Unit

INSTRUCTION MANUAL. Matos Refrigerators / Freezers

Transcription:

Laboratory refrigerators Application storage of water and sewage samples, piezometer leachate storage of AAS, GC or HPLC calibration standards storage of reagents chemical storage storage of medicines and vaccines Laboratory refrigerators are equipped with a cooling system and can provide a stable temperature between 0 C... +15 C. Calibration All thermostatic equipment manufactured by POLEKOAPARATURA can be provided with Calibration Certificate issued by accredited Measurement Laboratory. etailed information on accreditation of POLEKO Laboratorium Pomiarowe is available on website: www.polekolab.pl. 21

The BASIC, COMFORT, PREMIUM models are equipped with a PI microprocessor controller with an LC graphic display and illuminated touch s. Controller advantages temperature control adjustable start delay feature (1 min 99:59 h) adjustable hold at set point time for temperature from 1 min to 31 days or continuous operating operating with temperature priority mode overview of set and current parameters while operating recording of min, average and max temperature value for each segment operating with temperature priority mode defrosting function audible and visual temperature alarm temperature sensor fail alarm power failure control system (program continued after restoring power) realtime clock autodiagnostic function internal memory to store up to 2046 data records forced air convection with optional fan speed control (50100%) automatic fan shutdown after completing the program etailed description of parameters on page 82. Temp. [ C] 20 C off 100% 100% off T1 9 C TIME 11 9 C 0,5h 5h Time [h] Parameter set by the User fan speed control (option) delay of start (1 min...99:59 h) T1 segment temperature TIME 1 segment time 22

Control panel alarms or malfunction graphic LC display scroll down ENTER standby current temperature ESC scroll up Standard features: temperature range 0 +15 C quality control protocol (at +4 C) operation manual in English available menu languages: Czech, English, Estonian, French, German, Italian, Latvian, Polish, Portuguese, Russian, Spanish over temperature protection 1.0 class for BASIC and COMFORT models and 2.0 for PREMIUM models according to IN 12880 open door alarm wheels in standard for models 1200 and 1450 RS 232 and USB ports for data transfer internal LE light access port: (Ø 30 mm) wire shelves with slides set for BASIC and stainless steel wire shelves for COMFORT and PREMIUM models door lock solid door 23

PREMIUM TOP+ version All the units in TOP+ version are equipped with a PI microprocessor controller with a large (5,7 ) full colour touch screen, intuitive menu and user friendly software. They can be connected to Ethernet network for remote control from any computer, being one of the greatest advantages. Controller advantages multisegment temperaturetime profile (up to 100) loop function up to 99 times or endless adjustable start delay feature (from 1 min to 99:59 h or date/time) Administrator function to manage User accounts adjustable hold at set point time for temperature from 1 min to 999:59 h or continuous operating access control via login 7days programming temperature calibration adjustable ramps overview of set and current parameters while operating recording of min, average and max temperature value for each segment possibility of temperature calibration by the User audible and visual temperature alarm operating in temperature or time priority mode defrosting function temperature sensor fail alarm power failure control system (program continued after restoring power) digital timer realtime clock autodiagnostic function forced air convection with fan speed control (50100%) automatic fan shutdown after completing the program etailed description of parameters on page 82. GLP supporting functions password protected settings 20 user programs memory internal memory to store up to 4100 data records for each User, possibility to overview the values on the display or a PC computer in tabular or graphic form USB port to allow direct data recording or transfer into a flash drive events registry Temp. [ C] TOP+ Control application included (see page 68). off 100% 50% 100% 50% off T0 20 C TIME 0/1 T1 10 C TIME 1 TIME 1/2 T2 0 C TIME 2 10 C 0 C 1h 2h 5h 1,5h 3h Time [h] parameter set by the User: adjustable start delay (1 min 99:59 h) fan speed control T1/T2 segment temperature TIME 1 segment time TIME 0/1... ramp time 24

Control panel operating status (cooling/heating) current temperature program name loggedin user current date/time/weekday alarms door open info main menu overview of program parameter USB flash drive pluggedin internal light switch Standard features temperature range 0 +15 C Ethernet cable TOP+ Control software quality control protocol (at +4 C) English instruction manual available menu languages: English, Estonian, French, German, Hungarian, Italian, Latvian, Polish, Portuguese, Romanian, Russian, Spanish temperature protection 3.2 class to IN 12880 open door alarm wheels in standard for models 1200 and 1450 door lock USB port to allow direct recording and data transfer onto a flash drive RS 232 interface and LAN port internal LE light access port: Ø30 mm stainless steel wire shelves solid door 25

1 2 3 4 5 6 500 700 1200 1450 Parameter air convection chamber capacity [l] working capacity [l] door type temperature range [ C] temperature resolution [ C] controller interior housing 2 overall dims [mm] 3 internal dims [mm] BASIC COMF COMF/S PREM (TOP+) PREM/S (TOP+) BASIC COMF COMF/S PREM (TOP+) PREM/S (TOP+) 4 max shelf workload [kg] 5 Pw version max unit workload [kg] 6 W version nominal power [W] 7 weight [kg] over temperature protection power supply* shelves fitted/max warranty manufacturer Awidth B height C depth width ' width E height F depth F' depth G depth H height J height 150 122 * 230V 60Hz, 115V 60Hz also available 1 additional internal glass door 2 15 in TOP+ version are 60 mm higher, depth doesn t include 50 mm of power cable 3 dims of units with double door can be smaller 4 on uniformly loaded surface 70 55 all the above technical data refer to standard units (without optional accessories) All data on temperature stability and uniformity available on www.poleko.eu. forced 200 250 300 400 500 625 1365 163 203 243 324 386 450 1229 1 solid / glass or double (option) 0...+15 0...+15 / 10...+15 (option) every 0,1 microprocessor with external LC graphic display aluminum stainless steel to IN 1.4016 stainless steel to IN 1.4016 stainless steel to IN 1.4301 stainless steel to IN 1.4301 polished stainless steel polished stainless steel 570 620 620 620 620 620 660 750 1480 1450 600 860 1060 1260 1460 1860 1990 1990 1990 1970 680 650 650 650 650 650 810 860 860 950 430 480 480 480 480 480 430 480 2x480 2x490 470 520 520 520 520 520 510 600 1310 1340 430 660 860 1060 1260 1660 1510 1510 1510 1460 300 420 420 420 420 420 650 690 690 750 360 480 480 480 480 480 320 320 320 320 320 440 640 840 1050 1440 1380 1360 1360 1300 10 10 10 10 10 10 20 30 30 30 on request 100 100 100 100 20 30 40 50 60 60 100 150 300 300 on request 160 170 170 330 330 330 400 400 550 550 32 54 59 69 75 90 105 115 185 200 class 1.0 to IN 12880 / class 3.2 (option) / class 3.2 in PREM TOP+ 230 V 50 Hz 8 8 2/2 3/4 3/4 4/6 4/7 4/10 3/11 3/11 2x3/11 2 x 3/11 24 months POLEKOAPARATURA 5 reinforced shelf 6 reinforced version 7 for units in BASIC version with solid door 8 two columns with 3 shelves each 1460 1307 Options and accessories (icon description see pages 8081) INOX ALU INOX INOX/INOX IN 3.2 50...100% RS 422 RS 485 RS 232 RS 422 RS 485 USBK Professional KAFKA IQ OQ PQ 26

1/1 1/1/1 2/2 2/3 2/4 3/3 Parameter air convection chamber capacity [l] working capacity [l] door type temperature range [ C] temperature resolution [ C] controller interior housing 2 overall dims [mm] 3 internal dims [mm] BASIC COMF COMF/S PREM (TOP+) PREM/S (TOP+) BASIC COMF COMF/S PREM (TOP+) PREM/S (TOP+) 4 max shelf workload [kg] 5 Pw version max unit workload [kg] 6 W version nominal power [W] 7 weight [kg] over temperature protection power supply* shelves fitted/max Awidth B height C depth width ' width E height F depth F' depth G depth H height warranty manufacturer all the above technical data refer to standard units (without optional accessories) * 230V 60Hz, 115V 60Hz also available 1 additional internal glass door 2 depth doesn t include 50 mm of power cable 3 dims of units with double door can be smaller 4 on uniformly loaded surface 70/70 55/55 All data on temperature stability and uniformity available on www.poleko.eu. 70/70/70 55/55/55 forced 150/150 150/200 122/122 122/163 1 solid / glass or double (option) 0...+15 every 0,1 microprocessor with external LC graphic display aluminum stainless steel to IN 1.4016 stainless steel to IN 1.4016 stainless steel to IN 1.4301 stainless steel to IN 1.4301 polished stainless steel polished stainless steel 570 570 620 620 620 620 1170 1740 1680 1880 2080 2080 680 680 650 650 650 650 430 480 480 480 480 480 470 520 520 520/520 520/520 520 430 430 660 660/860 660/1060 860 300 420 420 420 420 420 360 480 480 480/480 480/480 480 320 320 320 320 320 440 640 840 1050 1440 10 10 10 10 10 10 on request 20 20 30 30/40 30/50 40 on request 320 480 350 350 350 350 65 98 109 114 124 119 class 1.0 to IN 12880 / class 3.2 (option) / class 3.2 in PREM TOP+ 230 V 50 Hz see table for single chamber models 24 months POLEKOAPARATURA 5 reinforced shelf 6 reinforced version 7 for units in BASIC version with solid door 150/250 122/203 200/200 163/163 Options and accessories (icon description see pages 8081) INOX ALU INOX INOX/INOX IN 3.2 50...100% KAFKA IQ OQ PQ RS 422 RS 485 RS 232 RS 422 RS 485 USBK Professional 27

1 A C B+60mm B F F E TOP+ version 2/3/4/5/6 A C B+60mm B F F H E G TOP+ version 500/700/1200/1450 A C F B E I 28

Laboratory freezers ZL Laboratory freezers Application longterm storage of samples and biological material for research storage of easily decomposing material (e.g. solid state) freeze resistance tests (e.g. of building materials: concrete, wood etc.) prefreezing plasma storage Laboratory freezers can freeze and store frozen samples. Calibration All thermostatic equipment manufactured by POLEKOAPARATURA can be provided with Calibration Certificate issued by accredited Measurement Laboratory. etailed information on accreditation of POLEKO Laboratorium Pomiarowe is available on website: www.polekolab.pl. 29

Laboratory freezers ZL The COMFORT and PREMIUM models are equipped with a PI microprocessor controller with an LC graphic display and illuminated touch s. Controller advantages temperature control operating with temperature priority adjustable start delay feature (1 min 99:59 h) loop function up to 99 times or endless overview of set and current parameters while operating recording of min, average and max temperature value for each segment audible and visual temperature alarm temperature sensor fail alarm power failure control system (program continued after restoring power) digital timer realtime clock autodiagnostic function internal memory to store up to 2046 data records natural (ZLNT) or forced (ZLWT) air convection etailed description of parameters on page 82. Temp. [ C] 20 C off T1 T1 10 C 9 C TIME 11 9 C 10 C 0,5h 5h Time [h] parameter set by the User adjustable start delay (1 min 99:59 h) T1 segment temperature TIME 1 segment time 30

Laboratory freezers ZL Control panel alarms or malfunction graphic LC display scroll down ENTER standby current temperature ESC scroll up Standard features temperature range 25 0 C for ZLN 85 and 40 0 C for ZLNT 125, 200, 300 wire stainless steel shelves for ZLN 85 and perforated stainless steel for ZLNT 125, 200, 300 quality control protocol (at 20 C) English instruction manual available menu languages: Czech, English, Estonian, French, German, Italian, Latvian, Polish, Portuguese, Russian, Spanish open door alarm access port: Ø20 mm door lock solid door RS 232 and USB ports for data transfer internal memory to store up to 2046 data records wheels in standard for ZLNT 300 31

Laboratory freezers ZL ZLN 85 ZLNT 125 new! new! ZLNT 200 ZLNT 300 ZLW200 ZLW300 Parameter air convection natural forced chamber capacity [l] working capacity [l] 95 76 130 109 210 180 310 262 210 140 310 213 door type solid temperature range [ C] 25...0 40...0 temperature resolution [ C] every 0,1 controller microprocessor with external LC graphic display COMF stainless steel to IN 1.4016 interior COMF/S stainless steel to IN 1.4016 PREM stainless steel to IN 1.4301 PREM/S stainless steel to IN 1.4301 COMF housing COMF/S polished stainless steel PREM PREM/S polished stainless steel 1 overall dims [mm] Awidth B height C depth width + width E height 610 880 650 380 420 590 660 1190 800 370 420 600 760 1380 800 450 520 770 760 1730 800 450 520 1120 760 1380 800 450 520 770 760 1730 800 450 520 1120 internal dims [mm] F depth 400 520 520 520 520 520 F+ depth 440 530 530 530 530 530 G depth 230 I depth 210 J depth 600 910 10 10 10 10 2 max shelf workload [kg] 3 Pw version 50 50 50 max unit workload [kg] 30 50 65 80 4 W version 100 130 160 160 160 nominal power [W] 200 450 470 470 500 500 weight [kg] 60 90 120 185 120 185 power supply* 230 V 50 Hz shelves fitted/max 2/4 2/3 2/4 3/6 2/4 3/6 warranty manufacturer all the above technical data refer to standard units (without optional accessories) * 230V 60Hz, 115V 60Hz also available 1 depth doesn t include 50 mm of power cable 2 on uniformly loaded surface 3 reinforced shelf 4 reinforced version All data on temperature stability and uniformity available on www.poleko.eu. 24 months POLEKOAPARATURA Options and accessories (icon description see pages 8081) INOX IN 3.2 KG RS 422 RS 485 RS 232 RS 422 KAFKA IQ OQ PQ RS 485 USBK Professional 32

Laboratory freezers ZL ZLN 85 A C B F F H E G ZLW 200/300 A C B F F H E ZLNT/125/200/300 A C F F E B 33

Laboratory freezers ZL ZLW 200 ZLN 200 Freezers with forced air convection are no frost freezers. The basic principle of such system is to manage humidity inside the unit and prevent frost formation on the walls. The fan in the chamber mechanically forces the air circulation and ensures continuous air exchange. It blows continuously over the cooling element, the air is cooled down and gets into the chamber through special channels. Humid air converts into frost, but is directed to a special evaporator compartment and settles on the coldest element. The compressor periodically turns off, the frost layer melts down by a heating element and is drained outside as a condensate. Advantages Uniform distribution of cool air through the chamber No need to defrost the unit Faster achieving of set temperature even with a large filling of the chamber Stable operation of the unit (in case of natural air convection freezers the bigger ice layer on the evaporator, the less efficient operation of the unit) isadvantages in comparison to natural air convection unit ue to continuous operation of fan and dehumidification of the chamber air stored samples may be subject to drying up. This can be easily prevented by proper packing of material Louder operation unit (due to fan noise operation) Higher power consumption (due to fan operation) 34