Electric Radiator. A cost effective approach to save fuel and reduce noise for generators from 2 to 10 kw

Similar documents
GETZ MANUFACTURING PART # CYLINDER DRYER

CD6102 / CD6102 OC / CD6102-2

Clean Steam Generators

Horizontal Bottle Cooler Installation and Operation Manual

Installation Instructions PP-AS20 Anti-Scale System

INSTRUCTION MANUAL HS-229G

Carbon Monoxide (CO) Detecting Ventilation Fan Controller Model 120VC Single Relay (100/25 PPM) (200/35 PPM)

INDOOR, SUSPENDED, STEAM OR HOT WATER HYDRONIC UNIT HEATER FOR VERTICAL OR HORIZONTAL CONFIGURATION

REFRIGERATED DROP-INS (2-6)FT-DI Installation and Operating Manual

Corrosion Resistant Fluid and Air Handling Systems.

User's Manual H-VC5. Chore-Logic. H-VC5 User manual. Version HPS 11/11/2006 User manual 1.02 ST50737MA 3/07. Page 1

MAN AUTO IMPORTANT INSTRUCTIONS PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING APPLIANCE

M-11 Series. Installation and Service Manual

Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K Upright, and Pendent Extended Coverage Light and Ordinary Hazard General Description

MaxLite LED MICRO-T PANEL

MaxLite LED VAPOR TIGHT LINEAR FIXTURES

Installation, Operation, and Maintenance Manual

Installation and Testing of Inverted Bucket Steam Traps Manual

Model/Sprinkler Identification Number JULY, 2011 WARNINGS

Design Criteria. Installation

Duct Mount. Installation Instructions

Service Parts, Kits and Accessories

DRY-PAK INDUSTRIAL AIR DRYER Installation and Instruction Manual

IN020 Rev F Page 1 of 8

COMMERCIAL REFRIGERATOR INSTRUCTION MANUAL

THARRINGTON OIL FIRED ROOM HEATERS MODELS 5135, 5160, R35, 10R60, 13R75 FEATURES SAFETY NOTICE

WMWLB / WMWFM / WTWLB / WTWFM Series Hydronic Heating Unit

Installation & Maintenance Instructions

INSTALLATION INSTRUCTIONS for PULSAR NS-Series Nav/Position or Nav/Position/Strobe Lights

Installation and Maintenance Instructions

CLIMAGUARD Air-to-Air Outdoor Heat Exchangers INSTRUCTION MANUAL. Rev. H 2015 Pentair Equipment Protection P/N

MCD. Corona Discharge Ozone Generators MANUFACTURED BY Bullock Lane San Luis Obispo, CA

HTLS. Heat Tracing Line Sensing Control Panel

Appearance and sensing characteristic Specification (temperature range) Model 10 to 70 C ES1B. 2 mm 20 mm 40 mm 60 mm. 40 dia. 60 dia.

ProTalk. Expander. Operating Manual Model B1292. July 28, 2009 Rev. 1.01

M Series Fan Filter Units

Series LFII Residential Flush Pendent Sprinklers 4.2 K-factor General Description

Installation, Operation and. Maintenance Instructions

14+ SEER R-410a AIR CONDITIONERS. Aluminum Coil Series. Efficiencies up to 14+ SEER/12 EER. Nominal Sizes Ton. Capacities 16.

Seaward Products OWNER S MANUAL WATER HEATERS. Serial Number:

MS-600 DESICCANT DEHUMIDIFIER

FOR EASY, FAST INSTALLATION AND FOR RESULTS

READ AND SAVE THESE INSTRUCTIONS. Air Boss Model T5200 Custom Packaged Electronic Air Cleaner. TRION

PLL Pump-Lead-Lag. Provides Pump Rotation, Auxiliary Pump Activation, and Pump Failure Alarm Control. Installation and Operation Manual

PLL. Pump-Lead-Lag. Provides Pump Rotation, Auxiliary Pump Activation, and Pump Failure Alarm Control. Installation and Operation Manual

Blade Series Heat Exchanger Operation and Installation

INSTALLATION AND OPERATING MANUAL

Silicone Rubber Heating Tape with Adjustable Thermostat Control (HSTAT Series) Instruction Manual

TrueClean ToteCleaner

TrueClean ToteCleaner

e Heater/Exhaust Fan/Light User s Guide

E C O L O G I C A L C O O L E R S INTELLIGENT

AV17 Series Switch-Tek Manual Direct and Remote Drum Mount Float Alarm 17 SEPT 08 Rev A

MaxLite LED Vapor Tight Linear Fixture

Series TY-B & TY-FRB, 10 mm Orifice, ISO 7/1-R3/8 Upright, Pendent, and Recessed Pendent Sprinklers Standard and Quick Response General Description

Glass Door Merchandiser Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment!

WKS 4000 SERIES (USA only) --INSTALLATION INSTRUCTIONS--

GASGUARD O 2. Oxygen Sensor OPERATING & INSTALLATION MANUAL

Republic Blowers. Ring Blower Side Channel Blower Regenerative Owner s Manual

IMPORTANT SAFETY INSTRUCTIONS EC-AG1-25 EC-AG1, EC-AG2 SAVE THESE INSTRUCTIONS.

Model CHEC 8.0 K-factor Concealed Horizontal Extended Coverage Quick Response Light Hazard, Sidewall Sprinklers General Description

Series ELO-231B 11.2 K-factor Upright and Pendent Sprinklers. Standard Response, Standard Coverage, General Description

1/24/01 SYLVANIA Process Heat THREADED INLINE HEATERS , , , , , ,

HotPoly Tote Tank / IBC Heaters (TTH Series)

FW-RA-LED Remote Multiplex Annunciator Panels

AA-480-XX OUTDOOR THERMOELECTRIC COOLER ASSEMBLY USER S MANUAL

Installation & Maintenance Instructions

ILLUSION 11.2 K-factor Extra Large Orifice Concealed Pendent Sprinklers Quick Response, Standard Coverage General Description

IMPORTANT. World-wide Patents. VIGIA is a trademark of Col-Ven S.A.

OPERATING INSTRUCTIONS

DESIGNED BY FIRE FIGHTERS FOR FIRE FIGHTERS.

GASGUARD H 2-1% Hydrogen Sensor OPERATING & INSTALLATION MANUAL

Please Read And Save These Instructions.

Rev. A AUGUST 2012 RNP SERIES REFRIGERATED COMPRESSED AIR DRYERS OPERATOR MANUAL RNP25 RNP35 RNP50

Protocol Station Remote Alarm

Operator s Manual. IP-100 Immersion Probe Cooler

Macurco HD-11 Hydrogen Gas Detector

SONANCE GARDEN SERIES SGS SYSTEM INSTRUCTION MANUAL

AIC Brazed Plate Heat Exchanger Operating and Instruction Manual

No Touch Door Release Exit Sensor ACA-NTEB

Single Station Remote Alarm

Instruction Manual Hydraulic Crimping Tool

Macurco HD-11 Hydrogen Gas Detector User Instructions. Important: Keep these User Instructions for reference

Serpentine II & Serpentine VI Air Heaters

Turbo Air Speed up the Pace of Innovation TBB-4SB CAUTION! PLEASE KEEP POWER SWITCH ON BEFORE OPERATING THIS EQUIPMENT

Laing Thermotech. Autocirc The Instant Hot Water Pump Models E1-BCANCT1W-06 and E1-BCANRT1W. Installation & Operating Manual

INSTALLATION AND OPERATING MANUAL

Series ELO-231 Upright and Pendent Sprinklers. Standard Response, Standard Coverage, General Description

FTC-350A. ual. Instruction and Operation Manual. Thermo NESLAB Manual P/N Rev. 11/08/00

Next Generation Corona Discharge Auto Voltage Sensing Installation Manual

Series LFII Residential Pendent Sprinklers 4.9 K-factor General Description

Air Pump Up to 800 gallons

Please Read and Save These Instructions.

5-Gallon Pail Mixer OWNERS MANUAL M-2000 SERIES MIXERS. Contents: Page: Safety, General & Receiving... 2 Operation... 3 Parts List...

CL & CLG Clamp Mount Mixers

WARNING. Pro Pack Portable Spray Pack 3A1292C. Operation. Model 24F893 Maximum Working Pressure 12 psi (0.83 bar, MPa)

Refrigerator Freezer Installation and Operation Manual

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Ice Cream Freezers

ES2-HB. Ordering Information. Dimensions. Specifications. Humidity Sensor Temperature/Humidity Sensor

BX Series. Installation, Operation, Maintenance Instructions & Spare Parts

Transcription:

Exceeding Military Standards without the Cost Electric Radiator A cost effective approach to save fuel and reduce noise for generators from 2 to 10 kw Description An engine s belt driven or direct driven fan and water pump present a considerable parasitic loss in the generators fuel efficiency. Engine manufactures typically size their fans (and water pumps) for the worst conditions: full load, hot weather, lowest engine speed, and this causes higher air velocities and pressure drops through the radiator. The belt driven fan supplied with a 15 HP engine can consume as between 1.5 to 3 HP of the engines gross HP (equivalent to between 1.1 to 2.2 kw of power). Small increases in engine RPM can double the fan HP requirement, and this hurts the fuel efficiency of variable speed generators. Polar s Electric Radiator starts with a large radiator core popular in 500+ HP racing cars. We need this large radiator because our design performance will be stationary as opposed to moving 200+ kilometers per hour in a racing car. Using a large radiator minimizes the air pressure drops through the radiator, allowing the use of more efficient fans. Also with the low air velocities and low volumes of air, we need a larger radiator to compensate for lower heat exchange efficiencies. Low air velocities and air flow rates allow fans of very small power. So instead of using 1.1 to 2.2 kw we use only 100 to 120 watts. This is a considerable fuel savings and noise reduction.

Description Multiple fans are used for more efficient air flow distribution over the surface of the radiator and provide reliability through redundancy. The vacuum dip, brazed, all aluminum, radiator core is more durable than the traditional soldered brass / copper radiators. This is one reason why most car companies have moved to this technology. To save cost most aluminum radiators use plastic header tanks as opposed to welded aluminum tanks. Plastic header tanks often crack or lose their seals after 3 years of service. For durability and reliability Polar has chosen the more expensive design of all welded aluminum tanks. Application Notes The aluminum radiator has to have the correct antifreeze; using improper fluids will cause electrolyses that can destroy the radiator in a short time. It is very important to connect a grounding cable from the radiator to the engine block. With improper grounding your radiator can develop leaks in very short time. For requirements exceeding 10 kw we have the option of using a fan tray assembly with stronger fans. The electric radiator can be mounted external to the generator shelter to reduce the air flow requirement through the shelter. This will require a suitable outdoor enclosure to protect the assembly. There are wind conditions that can stall the air flow through the radiator, so a cowl or shroud is recommended to protect the air exiting the radiator from being neutralized by the opposing natural wind. We recommend a 50/50 mix of water and coolant that is formulated for aluminum radiators and meets ASTM standards D336 and D4985. Extended life coolants can also be used if they meet the GM 6277 M DEX-COOL specification. Premix formulations are the safest to use due to eliminating the need to add water, which varies depending on the location. If water is added, care needs to be taken to ensure it doesn t have a high solids content. Water can only maintain a certain percentage of dissolved solids, so if the water has too many solids already, then the corrosion inhibitors in the coolant may drop out which will reduce the corrosion protection. Also, any water added needs to be between an 8 to 9 PH level. The coolant will shift to the low (acid) side as it is heated, so it s best to have the water slightly alkaline at an ambient temperature. This range should be confirmed with the coolant supplier.

Dimensions Specifications Fans use brushless DC motors with ball bearings and provide an estimated life exceeding 20,000 hours. Noise Level at 1 meter is approximatley 60 db(a). Part Number Voltage Current CFM M 3 /hr 84-19-001-12 12 Vdc 12 Amps 1300 2200 84-19-001-24 24 Vdc 6.6 Amps 1500 2550 84-19-001-48 48 Vdc 2.4 Amps 1050 1800

MUFFLER WITH COWL FEED THRU FOR RADIATOR AIR AND ENGINE EXHAUST FEED THRU HOLES FOR RADIATOR SUCTION / RETURN AND MUFFLER ELECTRIC RADIATOR WITH MUFFLER VENT VENT 16 BASE 16 BASE This installation configuration has the electric radiator mounted within the open frame assembly. Air is drawn into the shelter through louver in the shelter wall by the electric fans on the radiator. The electric fan pushes the cooling air through the radiator and exits the shelter directly. The volume of air moving through the air intake louver on the shelter wall has to satisfy both requirements of combustion air and radiator cooling. To simplify thermal insulation of the silencer /muffler and improve space inside the shelter the silencer is mounted external to the shelter. This is the most popular installation configuration as it keeps the generator and its fluids as one assembly within a frame. Vent air requirements for cooling and combustion is a nominal: 1200 cfm - 6 kw and smaller 1500 cfm - 10 kw and smaller 1800 cfm - 17 kw and smaller This installation configuration has the electric radiator and silencer / muffler assembly external to the shelter. This installation has popularity in very cold climates where there is the need to reduce the amount of low temperature air moving through the shelter. In this configuration only the combustion air and a very small amount cooling air is required from the vent on the wall. Vent air requirements for cooling and combustion is a nominal: 300 cfm - 6 kw and smaller 450 cfm - 10 kw and smaller 600 cfm - 17 kw and smaller

Limited Warranty Inc. (hereinafter Polar ), hereby warrants goods manufactured and sold by it to be free from defects in material and workmanship for 24 months after the date of shipment. The warranty is limited to repair or replacement at 249 E. Gardena Blvd., Carson, CA 90748 or other point designated by Polar of such parts as they appear to Polar, upon inspection, to be defective in material or workmanship. This warranty is extended to the first user only and no warranty is made or authorized to be made assignable on resale by the first end user. The above warranty includes a pass-through warranty from the engine and controller manufacturers for whatever period and warranty is in effect by the manufacturer at that time. The above warranty only extends to applications and installations which are approved by mutual agreement between Polar and the first end users. To obtain performance of any obligation under this warranty, contact must be made with Polar in writing at 249 E. Gardena Blvd., Carson, CA 90748. Submission of a claim does not obligate Polar to accept such claim in full or in part. No bills for service, labor or other expenses that have not been previously approved and authorized by Polar will be allowed. No goods or materials may be returned until authorized in writing by Polar and, where the return of the material is authorized, it shall be F.O.B. to whatever point Polar designated within the U.S.A. Repairs or alterations made to the goods without Polar written concurrence or the operation of the goods in excess of rated capacity will invalidate this warranty. There is no implied warranty or condition of merchantability. There is no other warranty or condition expressed or implied, statutory or otherwise, except such as is expressly set forth herein. Neither Polar nor manufacturers will be liable for any general, consequential or incidental damages, including without limitation any damages for loss of use or loss of profits, for any breach of warranty or condition or for negligence; Polar s and manufacturer s liability and the buyer s exclusive remedy being expressly limited to the repair or replacement of the goods sold by polar as provided herein.