The effects of green spaces (Palme trees) on the microclimate in arides zones, case study: Ghardaia, Algeria

Similar documents
The Effects of Green Spaces (Palme Trees) on the Microclimate in Arid Zones, Case Study: Ghardaia, Algeria

The Effects of Green Spaces (Palme Trees) on the Microclimate in Arid Zones, Case Study: Ghardaia, Algeria

Study on architecture and microclimate effect of combined container roof garden Dongtao Luan and Zhiguo Zhang

A study of Transient Performance of A Cascade Heat Pump System

KEYWORDS: air temperatures, urban climate map, building Density, vegetation

Smart Green Roofs: Cooling with variable insulation

Available online at ScienceDirect. Energy Procedia 91 (2016 ) 35 41

SOLAR WATER DISTILLATION BY USING WATER IN THE INNER GLASS EVACUATED TUBES

Available online at Energy Procedia 6 (2011) MEDGREEN 2011-LB

Urban Greenery Worldwide Researches on Urban Greenery and Urban Climate

Full-scale Experiment of Longitudinal Ventilation Smoke Control System and Central Smoke Exhaust System in City Underwater Tunnel

The thermal performance of green roofs in a hot, humid microclimate

The Thermal Effects of Green Roofs and Green Façades on an Urban Canyon

Analysis and Evaluation of a Passive Evaporative Cool Tower in conjunction with a Solar Chimney

INDOOR HUMAN THERMAL COMFORT OPTIMAL CONTROL WITH DESICCANT WHEEL COOLING SYSTEM

PhD Candidate, Université Paris-Est (France) and Institut d Urbanisme de l ALBA - Univerité de Balamand (Lebanon) 2

Landscape Representation and the Rural - Urban Divide in Urban Heat Island Literature Iain Stewart and Tim Oke

VENTILATIVE COOLING CONTROL STRATEGIES APPLIED TO PASSIVE HOUSE IN ORDER TO AVOID INDOOR OVERHEATING

Applying Numerical Simulation for Wind Availability Studies of Urban Morphology for Urban Planning in Hong Kong

Simulation of Full-scale Smoke Control in Atrium

Feasibility study of the passive solar room dehumidifying system using the sorption property of a wooden attic space through field measurement

A Numerical study of the Fire-extinguishing Performance of Water Mist in an Opening Machinery Space

Hygrothermal evaluation of a museum storage building based on actual measurements and simulations

COOL BUILT FORMS The Design/Planning Dilemma of Courtyards

How Sensitive We Build to Climate? Design for Comfortable Urban Environment

DOWNTOWN PHOENIX URBAN FORM PROJECT

AR/IA 241 LN 231 Lecture 7: Site Planning

On the Influence of Shade in Improving Thermal Comfort in Courtyards

INSTRUMENTATION AND EVALUATION OF COMMERCIAL AND HOMEMADE PASSIVE SOLAR PANELS

Available online at ScienceDirect. Physics Procedia 67 (2015 )

20 July 2015 A REVIEW OF STUDIES ON THE RELATIONSHIP BETWEEN URBAN MORPHOLOGY AND URBAN CLIMATE TOWARDS BETTER URBAN PLANNING AND DESIGN

GROUND COOLING OF VENTILATION AIR FOR ENERGY EFFICIENT HOUSE IN MALAYSIA: A CASE STUDY OF THE COOLTEK HOUSE

ScienceDirect. The Undrained Shear Strength of Overconsolidated Clays

Hot Water Making Potential Using of a Conventional Air- Conditioner as an Air-Water Heat Pump

Design of Humidity Monitoring System Based on Virtual Instrument

THE INNOVATION OF GREEN ROOF TO DADICATE THE BUILDING ENVIRONMENT IN HONG KONG

Indoor Climate Control Effect of AAC Panel Heat Capacity Experimental rooms and simulations with three structural materials

Effect of Relative Humidity on Oven Temperature of Locally Design Solar Carbinet Dryer

COOLING GUIDE TARGETS THE LONG, HOT SUMMER

Two-Pipe Fiber Bragg grating Temperature Sensor Applied in Cable Trench and Cable Pit

Evaporative cooling process adaptive for Baghdad city climate

Analysis of Pullout Resistance of Soil-Nailing in Lateritic Soil

EFFECTS OF COMBINING SMART SHADING AND VENTILATION ON THERMAL COMFORT

The Effect of Quantity of Salt on the Drying Characteristics of Fresh Noodles

A Study into the Standardization of Using Fire Detectors in Rail Vehicles for China

Experimental Research on Monomial Cooling Measure of Greenhouse in Summer

Ecological Landscape Planning and Design of an Urban Landscape Fringe Area: A Case Study of Yang an District of Jiande City

Procedia - Social and Behavioral Sciences 51 ( 2012 ) ARTSEDU 2012

Investigation of an evaporative air cooler using solar energy under Algerian climate

Daniel Hii Jun Chung

Thermodynamic analysis of air cycle refrigeration system for Chinese train air conditioning

Thermal Performance of Green Roofs: A Parametric Study through Energy Modelling in Different Climates

SMART GREEN ROOFS: Cooling with Variable Insulation

Available online at ScienceDirect. Procedia Engineering 89 (2014 )

AR/IA 241 LN 231 Lecture 6: Passive Cooling

663: Towards urban design guidelines from urban morphology description and climate adaptability

Available online at ScienceDirect. Energy Procedia 70 (2015 ) Yanjun Dai*, Xian Li, Ruzhu Wang

Landscaping for Energy Conservation

Pakis-Stem Blocks as Natural Heat Insulation Diminished Room Thermal in Surabaya

Urban Shape and Energy Performance: Evaluation of The Typical Urban Structures of Prague

EFFECT OF CENTRAL PILE IN INCREASING THE BEARING CAPACITY OF BORED PILE GROUPS

Study of Soil Cement with Admixture Stabilization for Road Sub-Grade

1. COOL ROOFS. What is a Cool Roof

Thermal Performance of a Loop Thermosyphon

EFFECT OF COMPACTION ON THE UNSATURATED SHEAR STRENGTH OF A COMPACTED TILL

Available online at ScienceDirect. Energy Procedia 78 (2015 ) th International Building Physics Conference, IBPC 2015

Performance Study of Solar Heat Pipe with Different Working Fluids and Fill Ratios

Feasibility Study of Condensation Heat Exchanger with Helical Tubes for a Passive Auxiliary Feedwater System

Falling Film Heat Exchangers for Solar Water Heaters

Corn drying experiments by pilot dryer

THE ROLE OF SUCTION IN THE PERFORMANCE OF CLAY FILL RONALD F. REED, P.E. 1 KUNDAN K. PANDEY, P.E. 2

Available online at ScienceDirect. Procedia Engineering 135 (2016 )

Performance evaluation of a liquid desiccant solar air conditioning system

Available online at ScienceDirect. Energy Procedia 78 (2015 )

Experimental Analysis of Open, Simple and Modified Greenhouse Dryers for Drying Potato Flakes under Forced Convection

Calculating crop evapotranspiration using a dual crop coefficient Part 3

The Development of Fire Risk Assessment Method for Heritage Building

Performance Analysis of Water-Water Heat Pump System of 100 kw Scale for Cooling Agricultural Facilities

ACHEIVING COMFORT IN SUBTROPICAL CLIMATES: BUILDING A MICROCLIMATE IN THE GUANGZHOU SCIENCE MUSEUM

The Use Of Attic Space For Cooling and Dehumidification

Design with nature: integrating green façades into sustainable buildings with reference to Abu Dhabi

Effect of domestic storage and cooking conditions on the risk distribution in ready to cook meat products

Available online at ScienceDirect. Energy Procedia 109 (2017 ) 56 63

Simulation of Evacuation Process in a Supermarket with Cellular Automata

Management, 2nd Edition

Procedia - Social and Behavioral Sciences 195 ( 2015 ) World Conference on Technology, Innovation and Entrepreneurship

PERFORMANCE MONITORING OF A HIGH-TEMPERATURE AIR-TO-WATER HEAT PUMP WITH INJECTION CYCLE INSTALLED IN A LOW-INSULATED SINGLE-FAMILY HOUSE IN BELGIUM

Green Cities: An A-to-Z Guide

DESIGN AND FABRICATION OF A PORTABLE REFRIGERATOR BASED ON PELTIER EFFECT

EFFECT OF RELICT JOINTS IN RAIN INDUCED SLOPE FAILURES IN RESIDUAL SOIL

Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress Heiselberg, Per Kvols. Publication date: 2016

CLASSIFICATION AND EXPERIMENTATION FOR THE DEVELOPMENT OF DAYLIGHTING SYSTEMS IN COLD AND SNOWY REGIONS

PERFORMANCE OF EARTH TUBE HEAT EXCHANGER COOLING OF AIR A REVIEW

ISSN: [Agcaoili S. O., 7(3): March, 2018] Impact Factor: 5.164

Urban Microclimate Design in Hong Kong

Available online at ScienceDirect. Energy Procedia 52 (2014 ) Vishal Vadabhat, Rangan Banerjee

PERFORMANCE-BASED SIMULATION FOR THE PLANNING AND DESIGN OF HYPER DENSE URBAN HABITATION

Swelling Treatment By Using Sand for Tamia Swelling Soil

Advanced Foundation Engineering. Introduction

Chapter 1 Introduction

Transcription:

Available online at www.sciencedirect.com Energy Procedia 18 (2012 ) 10 20 The effects of green spaces (Palme trees) on the microclimate in arides zones, case study: Ghardaia, Algeria Hamida bencheikh¹, Ameur Rchid² Abstract ¹Genie civil laboratory Amar Telidji University Laghouat Algeria ²Depatement of architecture Amar Telidji University Laghouat Algeria The microclimate and air quality in urban spaces are of a great interest for the well-being of citizens. Mitigating urban heat island is a major concern for human health by improving comfort especially in desert regions. While the thermal comfort is relatively easy to obtain in indoor spaces, it is more difficult to provide in outdoor ones. It is often sought by passive means. Vegetation could play an important role in ameliorating urban microclimates. It should be used judiciously in urban planning and designing outdoor spaces. The objective of this work is to explore the influence of green cover during summer on microclimate in the region of Ben-Isguen, a city of a hot- Ghardaïa (Algeria). Many studies have proved that vegetation can produce a cooling effect of 2 to 3 C on average. Gardens and urban parks in particular, in and around cities contribute to alleviating heat stress by creating the so-called "oasis effect" through public spaces. They improve thermal comfort and reduce cooling energy consumption. The microclimate of different locations, in both green and built-up areas (old town, palm grove, etc.) was characterized with the help of field measurements carried out during summer days. The results confirmed the presence of an important cooling effect of vegetation (PCI). It was shown that it is essentially a nocturnal phenomenon by displaying a maximum value of 10 C. This result is very important regarding the results of similar studies. The research demonstrated that the oasis effect is best developed around dawn in calm and clear sky conditions. Maximum daytime cooling effect of the green cover was 4.5 C in reference to old town. Nevertheless this effect showed fluctuation so that it displayed negative values by moments. The cooling effect of the palm grove is due to shade foliage, evapotranspiration, low heat capacity of vegetation and high aerodynamic roughness. In fact the oasis acts as a "heat sink". The old town of Ben-Isguen presented a diurnal heat island and a nocturnal cool island with maximum intensity of 3.5 C and 4 C respectively. The investigation of the oasis microclimate revealed that densely vegetated areas display higher cooling effect. The latter varied among different areas due to shade conditions, density of vegetation, sky view factor (SVF), soil characteristics and water surface availability. Key words: microclimate, urban space, heat island, green space, arid zone. 1876-6102 2012 Published by Elsevier Ltd. Selection and/or peer review under responsibility of The TerraGreen Society. Open access under CC BY-NC-ND license. doi:10.1016/j.egypro.2012.05.013

Hamida bencheikh and Ameur Rchid / Energy Procedia 18 ( 2012 ) 10 20 11 1. Introduction In the past, Mzab settlements (the ksurs and their cities gardens) were developed in response to both cultural and climatic needs of their inhabitants [1], the inhabitants of Mzab site use detached houses in Palme trees gardens for day living and the ksurs for night living (due to security problems) and now they use garden houses for day and night living during summer period. Our study investigates the effects of vegetations on the outdoor temperatures in hot arid zones, and Ghardaia in the south of Algeria was taken as a case study. Vegetation cover has positive effects on the microclimate [2], it can lower the outdoor temperature [3-4-5]. Many studies on urban tree cover like green CTTC (cluster thermal time constant) model have indicated a very high correlation between daily outdoor temperature and consumption of space conditioning energy [6-7-8]. It is assumed that a tree has a projection area of shading and a reduction of sky view factor, in the air surrounding a tree always has a high humidity due to tree irrigations system. The surrounding space between detached houses in Palme trees are well protected from solar radiations and the surrounding air is usually saturated with humidity, which can affect directly the outdoor temperature. M. Santumouris [9] shows that trees with a crown of 8m could reduce the peak cooling load by 2 to 10%. Akbari [7], found that trees reduce the cooling load by 21-53% in California. This paper studies the effect of Palme trees on microclimate in arid zones, and Ghardaia in the south of Algeria (32.3 N 3.49 E) was taken as a study case. 2. Study area Ghardaia is located in the south of Algeria, which is well known by its hot arid climate, its ksurs (dense old buildings), its river, and its detached houses surrounded by Palme trees as shown in figure (1). The climate of Ghardaia is characterized by a very hot dry summer, the mean summer temperature in July is 36.8 C and the maximum absolute temperature is 46 C. The outdoor temperatures were recorded in four different sites in addition to the reference point; Figure (2) shows the different sites where field measurements were recorded. The reference point is situated at the frontier of Palme trees site on the top of the local radio building and the first site, detached houses in Palme trees (Oasis) is situated at the bottom of the valley as shown in figure (3). The second site called Beni Ezgen ksur, the old part of the city (high density buildings and partially covered narrow streets as shown in figures (4, 5). The third site the new city extension called Tafilalt and the forth site is the new detached houses in open area without vegetations.

12 Hamida bencheikh and Ameur Rchid / Energy Procedia 18 ( 2012 ) 10 20 Figure. 1 Houses surrounded by Palme trees North Tafilelt zone3 Palme trees zone 1 zone Refrence point The ksur zone 2 New extension zone 4 Figure 2 The different zones where field measurements were recorded.

Hamida bencheikh and Ameur Rchid / Energy Procedia 18 ( 2012 ) 10 20 13 Figure. 3 Weather station in Palme trees zone at low level Figure. 4 Weather station in the street of the old ksur Beni Ezgen

14 Hamida bencheikh and Ameur Rchid / Energy Procedia 18 ( 2012 ) 10 20 Figure. 5 Weather station on the top of houses roof in the old ksur Beni Ezgen 3. Measurement instrumentations. Ten weather stations type HOBO where planted in five different points; A reference weather station was planted on the top the local radio station in open area. In point one, the old ksur of Beni Ezgen, two weather stations were planted, one on the top of houses and the other one in 1.3m wide street. In point two, Tafailelt, two weather stations were planted, one on the top of houses and the other in 6 m Wide Street. In point three, Palme trees houses, two weather stations were planted, one at human height above the soil, the second at canopies level on the top of houses. In Point four, new detached houses in open area, one weather station was planted on the top and the second in 4.7m wide street. In point five, at the bottom of the valley one station was planted on the top of one level building. The streets weather stations were 4m height from the ground for security raisons and the period of measurements was from the 16 th until 20 th of august. Figures (3 to 5) show the station at each site. In addition to the weather stations, three same model testometers were used to measure the outdoor temperatures, relative humidity and wind speed in Palme trees zone. Two of them were placed in the Palme trees center (high density and continues canopies), the first one at 1.2m of height and the second one at 5.5m just below canopies, these measurement help in studying the temperature stratifications above the ground and at canopies level. The Palme trees were irrigated once a day at 18h 30. The third testometer was placed in the outer Palme trees site (less density and discontinues canopies). The testometers measurements were taken from 20 th until 22 nd August.

Hamida bencheikh and Ameur Rchid / Energy Procedia 18 ( 2012 ) 10 20 15 4. Results and discussion. Ghardaia a hot arid city situated in the south of Algeria, the outdoor temperatures were recorded by fixed weather stations at two level points, street level and canopies level (roof of building and bottom of building) for the four mentioned sites and the reference weather station site. Figure (6) presents the outdoor temperature variation at building roof level in the four sites in comparison with the out door reference site. Figure (7) presents the outdoor temperature variation for the same sites at street level. Figures (6, 7) show that the high diference in outdoor temperatures between sites were recorded during night time at canopies level in palm trees site. At canopies of Palme trees the outdoor temperatures were higher by 0.5 C than the reference site in two times, early in morning and at midday due to solar radiation. Under the canopies, in the Palm trees site and in the open site, the lower outdoor temperatures were recorded during night, which also cited by, Shashua-Bar and Hoffman[10], Bacci and al. [11] and S. Spronken and Oke [12]. The Oasis presents the lower outdoor temperature due to the intense evaporation and the low thermal capacity of the vegetations. The night outdoor temperatures recoded were lower by 4 C than the ones recorded in the open site, which was similar to the results in many bibliographical references such as; Correa & al. [13] and Upmanis & al. [14]. 47.5 T air Palm (niv haut) T air toit Ksar T air toit Tafilelt T air toit Extens T air Réf 45 42.5 40 37.5 T air ( ) 35 32.5 30 27.5 25 22.5 Time Temps in hours Figure 6. Out door temperature recorded in different zones at canopies level

16 Hamida bencheikh and Ameur Rchid / Energy Procedia 18 ( 2012 ) 10 20 47.5 T air Palm (niv haut) T air toit Ksar T air toit Tafilelt T air toit Extens T air Réf 45 42.5 40 37.5 T air ( ) 35 32.5 30 27.5 25 22.5 Time Temps in hours Figure 7. Out door temperature recorded in different zones at street level Figure (8) presents the heat-island and the cool island (the negative values present the heat island and the positive one present the cool-island) at the top of buildings and in the street of Beni Ezgen ksur compared to the reference point. The maximum cool-island was 4 C recorded at 4. 10 Am and the maximum heat-island was 3.5 c recorded at 13.00 pm. Figure (9) presents the heat-island and the cool island at the top and the bottom of buildings of Tafilelt ksur compared to the reference point. The maximum cool-island was 3.8 C recorded at 4. 10 Am and the maximum heat-island was 3 c recorded at 13.00 pm. Figure (10) presents the heat-island and the cool island at the top and the bottom of buildings of Palme trees site compared to reference point and the maximum cool-island was 10 C recorded twice and minimum value was 2 C. Figures (11, 12) present the cool-island in Palme trees site at the top and the bottom of buildings compared to the other three sites, Beni Ezgen ksur, Tafilelt ksur and open site houses. The maximum cool-island at the bottom of buildings level recorded during night time were 7.2 C, 9.2 C and 7.1 C compared to Beni Ezgen ksur, Tafilelt ksur and open site houses respectively. The maximum cool-island at the top of buildings level were recorded during night time, 5.1 C, 7.8 C and 4.5 C compared to Beni Ezgen ksur, Tafilelt ksur and open sit houses respectively. The outdoor air temperatures during day Time in Palme trees site were lower by, 2 C than the reference weather station, 3 to 4 C than the ones in Beni Ezgen site, and by 5 to 8 C, lower than Tafilelt, and the open site houses as shown in figure (11). During night time the

Hamida bencheikh and Ameur Rchid / Energy Procedia 18 ( 2012 ) 10 20 17 outdoor temperatures in Palme trees site were lower by 5 to 8 C than the Beni Ezgen site, and by 10 C lower than Tafilelt, and the open site houses as shown in figure (12). Two other measurements were taken at street level in two different points in Palme trees site, the fist one at the center of the vegetations and the other at the outer limit of the vegetations. From figure (13), at the outer limit of the vegetation, the outdoor air temperature is higher by 2 to 4 C than the temperature in the center of the vegetation, due to the density of Palme trees which gives well shaded area. 4 3 2 1 T 0-1 -2-3 -4-5 Time in Temps hours Figure 8 Temperature difference at roof and street level between reference weather station and old ksur 4 3 2 1 0-1 -2-3 -4-5 T Time Temps in hours Figure 9 Temperature difference at roof l level between reference weather station and Tafilelt, and open site

18 Hamida bencheikh and Ameur Rchid / Energy Procedia 18 ( 2012 ) 10 20 12 10 8 6 T 4 2 0-2 -4 Time Temps in hours Figure 10 Temperature difference at roof and street level between reference weather station and Palme trees site 10 9 8 7 6 5 T 4 3 2 1 0-1 -2 Temps Time in hours Figure 11. Temperature difference at street level between Palme trees site and old ksur, tafilelt, open site

Hamida bencheikh and Ameur Rchid / Energy Procedia 18 ( 2012 ) 10 20 19 8 7 6 5 4 T 3 2 1 0-1 -2 Time Temps in hours Figure 12. Temperature difference at roof level between Palme trees site and old ksur, tafilelt, open site 46 T air Pt périph T air Pt central-sup T air Pt central-inf 44 42 40 38 T ( C) 36 34 32 30 28 26 24 19:53 20:53 21:53 22:53 23:53 0:53: 1:53: 2:53: 3:53: 4:53: 5:53: 6:53: 7:53: 8:53: 9:53: 10:53 11:53 12:53 13:53 14:53 15:53 16:53 17:53 18:53 19:53 20:53 21:53 22:53 23:53 0:53: 1:53: 2:53: 3:53: 4:53: 5:53: 6:53: 7:53: 8:53: 9:53: 10:53 11:53 12:53 13:53 14:53 15:53 Temps Time in hours Figure 13. The out door air temperature at soil level in the middle and extremities of the Palme trees site

20 Hamida bencheikh and Ameur Rchid / Energy Procedia 18 ( 2012 ) 10 20 5. Conclusion The study shows that the outdoor temperatures in center of Palme trees site were lower by 5 to10 C in comparison to the other studied sites. The old ksur characterized by its compact buildings with narrow streets and its surrounding ramparts was designed to offer a good thermal comfort and security from enemies, however in our days the security problems does not exist. A second ksur called tafilelt was designed in 1990 in the same shape as the old one but with larger streets, for cars and technique equipments to get inside, but our study shows that the outdoor temperatures in the ksur of tafilelet were greater than the outdoor temperatures in Palme trees site. Therfore we suggest a new urbanization method, which gives the vegetations (Palme trees) great space in all buildings design. For further studies it is recommended to find the optimum vegetation surface percentage in the new extension of Ghardaia city. The existence of Palme trees surrounding houses offer a better microclimate, protection for hot wind, sand and also Palme trees fruits (dates) for the inhabitants. References [1] A. Bouchair, A. Dupagne, Buildin g traditions of Mzab facing the challenges of re-shaping of its built form and society, Building & Environment 2003, 38 1345-1364. [2] R. Giridhagan & al, Lowering the outdoor temperature in high-rise-density residential developments of costal Hong Kong: The vegetation influence, Building & Environment, 2008, 43 1583-1595. [3] B. Givoni, Climate considerations in building and urban design. USA Wiley, 1998 [4] R. Emmanuel, Summertime heat island effects of urban design parameters, PhD thesis, The University of Michigan, 1997. [5] L. Shashua-Bar & al, Integrated thermal effects of generic built forms and vegetation on the UCL microclimate, Building & Environment, 2006, 41 343-354. [6] YJ. Huang & al, The potential of vegetation in reducing the cooling loads in residential buildings, Climate and Applied Meteorology, 1987, 26 1103-16. [7] H. Akbari & al, Peak power and cooling energy savings of shade trees, Energy and Buildings, 1997, 26 139-148. [8] L. Shashua-Bar, ME. Hoffman, Geometry and orientations aspects in passive cooling of canyon streets with trees, Energy and Buildings, 2003, 35 61-68. [9] M. Santamouris, editer, Energy and Climate in the urban built environment, UK, James & James, 2001 (chapters 1, 3-7,10,11). [10] L. Shashua-Bar, ME. Hoffman, Vegetation as climatic component in the design of an urban street, Energy and Buildings, 2000, 31 221-235. [11] L. Bacci and all, Thermo-hygrometric conditions of some urban parks of Florence, Italy and their effects on human well-being, Proceedings 5 th international conference on urban climate, 2003 1-5 September, Lodz, Poland. [12] R. A. Spronken-Smith and T. R. Oke, The thermal regime of urban parks in two cities with different summer climates, International Journal of Remote Sensing, 1998, 19 2085-104. [13] E. Correa and al, Impact of 23th conference on passive and low energy architecture, PLEA Geneva Switzerland, 2006 b. [14] H. Upmanis and al. The influence of green areas on nocturnal temperatures in high city (Goteborg, Sweden), International Journal of climatology, 1198, 18 681-700.