Analysis of a Heat Pump System Driven by Gas Engine for Domestic Use

Similar documents
System Using Exhaust Heat from Residential GHPs

The Innovative Green Technology for Refrigerators Development of Innovative Linear Compressor

Design and Research of the Digital VRV Multi- Connected Units With Three Pipes Type Heat Recovery System

Noise Reduction Technology With Porous Metal for Refrigerant Two-Phase Flow Through the Expansion Valve

Experimental Study on the Performance and Oil Return Characteristics of Multi-Split Air- Conditioning System for Medium Size Building

Performance of R-22, R-407C and R-410A at Constant Cooling Capacity in a 10

Experimental Research On Gas Injection High Temperature Heat Pump With An Economizer

Improving Heating Performance of a MPS Heat Pump System With Consideration of Compressor Heating Effects in Heat Exchanger Design

Design and Research of the Commercial Digital VRV Multi-Connected Units With Sub-Cooled Ice Storage System

The Effect of the Ventilation and the Control Mode on the Performance of a VRV System in Cooling and Heating Modes

Experimental Study About An Amount Of Oil Charge On Electric Driven Scroll Compressor For Electric Vehicle

Development of a Transient Simulation Model of a Freezer Part II: Comparison of Experimental Data with Model

Feasibility of Controlling Heat and Enthalpy Wheel Effectiveness to Achieve Optimal Closed DOAS Operation

The Development Of High Efficiency Air Conditioner With Two Compressors Of Different Capacities

Energy Savings Potential of Passive Chilled Beam System as a Retrofit Option for Commercial Buildings in Different Climates

Conceptual Design of a Better Heat Pump Compressor for Northern Climates

A study of high efficiency CO2 refrigerant VRF air conditioning system adopting multi-stage compression cycle

Purdue e-pubs. Purdue University

A SOPHISTICATED, LOW-COST, ENERGY-EFFICIENT, SMALL-CAPACITY LNG VAPORIZER AND ITS PRACTICAL USE

Performance Characteristics and Optimization of a Dual-Loop Cycle for a Domestic Refrigerator- Freezer

Experimental Investigation on Condensation Performance of Fin-and-Flat-Tube Heat Exchanger

Development Of 2-Cylinder Rotary Compressor Series For Light Commercial Use With R410A

Experimental Investigation of Closed Loop Oscillating Heat Pipe as the Condenser for Vapor Compression Refrigeration

Development of R744 Two Stage Compressor for Commercial Heat Pump Water Heater

High Efficiency R-134a Compressor for Domestic Refrigerator

System Modeling of Gas Engine Driven Heat Pump

Development of a Novel Structure Rotary Compressor for Separate Sensible and Latent Cooling Air-Conditioning System

Introduction of Transcritical Refrigeration Cycle Utilizing CO2 as Working Fluid

Experimental Study on Match for Indoor and Outdoor Heat Exchanger of Residential Airconditioner

Effects of Flash and Vapor Injection on the Air-to- Air Heat Pump System

Fifteen Years of Dehumidification Results from Heat Pump Water Heaters

Sub-Critical Operation of the CO2 Expander/ Compressor

Performance Comparison of R32, R410A and R290 Refrigerant in Inverter Heat Pumps Application

Lower GWP Refrigerants Compared to R404A for Economizer Style Compressors

High Efficiency Heat Pump for Domestic Hot Water Generation

Efficiency of Non-Azeotropic Refrigerant Cycle

Control Method Of Circulating Refrigerant Amount For Heat Pump System

Performance Characteristics of Air-Conditioner Under Tropical Ambient Condition

Visualization of Evaporatively Cooled Heat Exchanger Wetted Fin Area

Effect of Modification in Refrigerant Passage of an Automotive Air Conditioning Compressor

Comparison of Energy Efficiencies of Commercial Refrigeration Direct and Indirect Systems

Performance Evaluation and Design Optimization of Refrigerated Display Cabinets Through Fluid Dynamic Analysis

Performance Investigation of Refrigerant Vapor- Injection Technique for Residential Heat Pump Systems

Drop-in Testing of Next-Generation R134a Alternates in a Commercial Bottle Cooler/Freezer

Development of an Open Drive Scroll Compressor for Transportation Refrigeration

Performance Evaluation of the Energy Efficiency of Crank-Driven Compressor and Linear Compressor for a Household Refrigerator

Heat Exchanger Shelves For Better Temperature Control Of Food In Open-Type Display Cases

Hunting Phenomena Of Automotive Air Conditioning Systems With Variable Displacement Compressor

Research on Waste Heat Recovery System for Residential Gas Engine-Driven Heat Pump

The Design Of A New Generation Of Twin Screw Refrigeration Compressors

Hot Water Making Potential Using of a Conventional Air- Conditioner as an Air-Water Heat Pump

HSPF Calculation of a System Allowing Switching Between a Single-Stage to a Two-Stage Compression System

Higher Efficiency, Lower Sound, and Lower Cost Air Conditioning Compressors: Part 1 Efficiency

Autonomic Distributed Coordinative Control "F- VPM" for Multiple Air Conditioners with Concurrent Cooling and Heating Operation

Air-Cooled Heat Exchanger Performance for R410A

R32 Compressor for Air conditioning and Refrigeration applications in China

Diagnosing Troubles in Refrigeration Units with Screw Compressors

Low GWP Refrigerants for Air Conditioning Applications

Purdue e-pubs. Purdue University. T. Hamada Mitsubishi Heavy Industries Ltd. N. Nishiura Mitsubishi Heavy Industries Ltd.

Some Modeling Improvements for Unitary Air Conditioners and Heat Pumps at Off-Design Conditions

Optimization Study of Absorption/Compression Cooling Cycles

Refrigeration Cycle And Compressor Performance For Various Low GWP Refrigerants

Effect of Height Difference on The Performance of Two-phase Thermosyphon Loop Used in Airconditioning

Selection of a refrigeration oil for the R32 refrigerant and evaluation of the compressor reliability

Low Global Warming Refrigerants For Commercial Refrigeration Systems

AHRI Low Global Warming Potential Alternative Refrigerants Evaluation Program (Low-GWP AREP) â Summary of Phase II Testing Results

Design of Compressors to Meet the Performance Ranges Required for Residential Air Conditioning

Tribology Characteristics of HFO and HC Refrigerants with Immiscible Oils - Effect of Refrigerant with Unsaturated Bond -

Systematic Study of the Solution Properties of Low Global Warming Potential R-404A Replacement Refrigerant Blends with Various Polyol Ester Lubricants

An Investigation Into The Influence Of Improved Refrigeration Cycle And Refrigerants On An Energy Efficient Domestic Refrigerator

Analysis of Oil Pumping in the Hermetic Reciprocating Compressor for Household Refrigerators

Investigation, Analysis and Solution of Higher Noise of Heat Pump Water Heater

An Analysis of a New Type Refrigeration Cycle (MICLOSS)

Performance Characteristics of a Refrigerator- Freezer with Parallel Evaporators using a Linear Compressor

Development of Performance Test Facility of Positive Displacement CO2 Refrigerant Compressor

AHRI Low Global Warming Potential Alternative Refrigerants Evaluation Program (Low-GWP AREP) Summary of Phase I Testing Results

Comparison Of Hermetic Scroll And Reciprocating Compressors Operating Under Varying Refrigerant Charge And Load

Design of Divided Condensers for Desiccant Wheel-Assisted Separate Sensible and Latent Cooling AC Systems

Development of HFC-134a Compressor for Domestic Refrigerator

Experimental Analysis of a Stirling Refrigerator Employing Jet-Impingement Heat Exchanger and Nanofluids

Two-Step Capacity Modulation of a Single Cylinder Compressor

An Experimental Investigation Of Oil Retention Characteristics In CO2 Air-Conditioning Systems

Development and Performance Measurements of a Small Compressor for Transcritical CO2 Applications

The Development of the Energy-Saving Technology by the Composition Control of R407C

Evaluation and Optimization of System Performance using HFO-mix Refrigerants for VRF and Mini-split Air-Conditioner

DEVELOPMENT OF A KILN DRIED WOOD SYSTEM USING HEAT PUMP TECHNOLOGY

Performance of an Improved Household Refrigerator/Freezer

Modelling of an Integrated Supermarket Refrigeration and Heating System Using Natural Refrigerants

Energy Consequences of Non-optimal Heat Pump Parameterization

Geothermal ORC Systems Using Large Screw Expanders

Experimental Study of Fouling Performance of Air Conditioning System with Microchannel Heat Exchanger

Load Sharing Strategies in Multiple Compressor Refrigeration Systems

Development of Large Refrigerant Compressors

Energy Transfer Based Test Method Development and Evaluation of Horizontal Air Flow Re- Circulatory Air Curtain Efficiencies

Energy Efficiency of Air-to-Air Mini Heat Pump

for family composition, time allocation of people, ownership and specification of home appliances. This paper first presents the simulation procedure

Effects of Frost Formation on the External Heat Transfer Coefficient of a Counter-Crossflow Display Case Air Coil

Numerical Study on the Design of Microchannel Evaporators for Ejector Refrigeration Cycles

Multiple split-system air-conditioners and air-to-air heat pumps Testing and rating for performance

Leakage of Mildly Flammable Refrigerants into a Room

Transcription:

Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 1986 Analysis of a Heat Pump System Driven by Gas Engine for Domestic Use M. Otsubo K. Okuma K. Yamazaki H. Yuyama Follow this and additional works at: http://docs.lib.purdue.edu/iracc Otsubo, M.; Okuma, K.; Yamazaki, K.; and Yuyama, H., "Analysis of a Heat Pump System Driven by Gas Engine for Domestic Use" (1986). International Refrigeration and Air Conditioning Conference. Paper 15. http://docs.lib.purdue.edu/iracc/15 This document has been made available through Purdue e-pubs, a service of the Purdue University Libraries. Please contact epubs@purdue.edu for additional information. Complete proceedings may be acquired in print and on CD-ROM directly from the Ray W. Herrick Laboratories at https://engineering.purdue.edu/ Herrick/Events/orderlit.html

ANALYSIS OF A HEAT PUMP SYSTEM DRIVEN BY A GAS ENGINE FOR DOMESTIC USE Michio Otsubo Keiko Okuma Kisuke Yamazaki MitAubishi Electric Corp. Consumer Products Research Lab. 2-14-40 Ofuna, Kamakura 247 Japan Telex. Tel. 3862-126 0467-44-6111 Hiroshi Yuyama Mitsubishi Electric Corp. Shizuoka Works 3-18-1 Oshika, Shizuoka 422 Japan Telex. Tel. 3962--321 0542-85-1111 1. ABSTRACT A heat pump system driven by a gas engine (i.e., a GIIP system) is described, which is used for 3-room air-conditioning and the hot water supply in a resj.dential house. This GHP system was developed in cooperation with GAS Utilities The system construction, test conditions, operating characteristics and economic estimations are described in this paper. Heat recovered from the engine is used for water heating and space heating. The system is a high-energy recovery type with a hot water storage tank. This GHP system is compared with a conventional gas furnace, gas fired water heater and room ''""]f'r'" sysl '''" using a simulation program to estimate the energy consumption of each system. 2. INTRODUCTION Although the energy situation has recently eased in Japan with the reduction of oil prices, saving energy is still nationally important and much energy-saving equipment has be~n developed since the energy crisis of increased oil prices in 1973. Electric power demand during the summer increases rapidly in Japan, and it has become difficult to provide power plant to meet this seasonal demand. Consequently, cooling other than by electricity is very important. A beat pump system driven by a gas engine is now attracting great interest. This system has high energy-conversion efficiency, because it uses heat recovered from the gas engine. This paper gives an outline of this GHP system and the results of an economic analysis. 3. SYSTEM SPECIFICATIONS The basic specifications and schematic diagram of the system are shown in Figure 1. This GHP system has a refrigerant heating cycle to recover exhaust heat from the engine for heating using a refrigerant pump, and a 200 ~ hot water storage tank was provided. Figure 2 shows a picture of the GHP system outdoor unit, hot water storage tank and one of the indoor units. An alternative system was compared with the GHP system; namely a conventional gas furnace, gas-fired water heater and room cooler combination system. The cooling capacity of the GHP system was 6.28 kw (5400 kcal/h), its space heating-capacity was 9.30 kw (8000 kcal/h) and its water heating capacity was 9.88 kw (8500 kcal/h). The speed of the engine was varied from 1100 rpm to 2200 rpm corresponding to the heat load. The efficiency of heat recovery from the engine exhaust gas was about 70%. The efficiency of the comparative gas furnace and gas-fired water heater was assumed to be 80%, and the EER of the room coolers was 2.6. I. I.R. - Commissions E2 Indiana (U.S.A.) - 1986-8 112

Indoor: heat: exchanger: (x3) Expansion valve Figure l. Schematic diagram of the GHP system with a hot water: storage tank (a) Outdoor unit (b) Hot water: storage tank (c) Indoor unit 113 Figure 2. GHP system components

,,_,: ~ --=-~ J~"~.:;e '(J,~.::~r --- :;:::;;.r J~ ~ 4. INPUT CONDITIONS For the computer simulation, a wooden two-storied residential house (cf. Figure 3) was selected, three rooms (living room, children's room and bedroom) being air-conditioned and any two of them being air-conditioned simultaneously. The original air-conditioner operating pattern was set, and the air-conditioning heat load was calculated by the currently used method(l)(2). The results of calculation are shown in Figure 4. In Tokyo, the normal heating season is from December to March, and the cooling season, from June to September. The hot water usage pattern was set and the load was calculated from this pattern. The results are shown in Figure 4. The other input conditions were the temperature of inlet city water, ~eather probability and outdoor temperature. The unit price of gas was 154.72 yen/m, the electric 3 power price was 31 yen/kwh, and the calorific value of the gas energy was 13 kwh/m. ~llljll~~~~~l!~!~~~i a :;::: ------i::: : ;:;12.96 m ;: """"~~~!~~:.:.:.:.@~~""""~@~~~~"""l~..,.~i~ll~~~"'---10:=~----j _j_ t------- 9. 9 m 9, 9 m ------11 lst floor area: 57.51 m 2 2nd floor area: 46.17 m 2 Total floor area: 103,68 m 2 Figure 3. Model residential house plan 2 1000,------------------... ~ ""..:l 800 "" "... :;; 600 " "' 400 Hot water Cooling Heating 200 8 9 10 11 12 1 2 3 Month Figure 4. Monthly air-conditioning load and hot water supply (in Tokyo) 114

5. SYSTEM OPERATING CHARACTERISTICS This GRP system can use exhaust heat from the gas engine to heat the water supply for do.estic use. The quantity of hot water and its temperature for each season are shown in Table 1 with and without bath usage. During the winter, 5o i of hot water was maintained for uses other than taking baths in the GHP system. Table 1. Hot water storage temperature and amount GHP with HWST bath non-bath temp. amt. temp. amt. Season c Jl. c i Winter 85 200 85 50 Intermediat:e 65 200 65 so seasons Summer 65 200 65 200 6. RESULTS OF COMPUTATION The computer simulation calculation was run at 20-minute intervals, and the results of storage temperature transition and hot: water quantity iri the storage tank are shown in Figure 5. In this case, water in the hot water storage tank was heated from 14:00 to 16:00, to provide a high temperature zone of 200 1 at 16:00. In the case of bath usage, about 100 ll. of hot water at 8s c was used at around 20:00, and it was desirable that the water heating time should be close to that time for reduction due to heat loss, this heat loss from the hot water storage tarik being about 10% during the winter (7% during summer). '""'... 200 >.......... c::: ;l "' "'... <U... ;. "'... 0 ;t: 100 Low temp.,zone High temp. zone 0 3 9 15 21 24 Time Variation of hot water quantity (January, weekday, fine weather, bath usage) Figure 5. Results of simulation for the GRP system with a hot water storage tank 115

The monthly energy consumption of each system is shown in Figure 6. During the summer, the electric power consumption of the GHP system was less than one-third that of the comparative system. During the winter, the comparative system used about 1.5 times as much energy as the GHP system. GHP with HWST Gas furnace and room coolers... 2000... ""' 2 2000..::: " = g ~ -.. ;: s 1500 Electric (sub)... Gas (main) ~ 1500 Electric (main + sub) Gas (main) = = I'-...... ~ 1000 ~hl~ 0 "' "'., Ei Ei " ",:;... 1000 500 = 500 0 0 <J <I >. n >.., 0.. 0...... 00 00 " 8 9 10 ll 12 1 2 3 = 1>:1 '" "" lrlfml \ r-~ F 1-4 5 6 7 8 9 lo u 12 1 2 3 Month Month Figure 6. Comparison of monthly energy consumption - Figure 7 shows the monthly running costs of each system. The average annual cooling load for domestic use in this case was 1.25 MWh, the space heating load was 2.94 MWh and the water heating load was 4.04 MWh, giving an annual total load of 8.33 MWh. Using these figures produced the following results: the annual running cost for the GHP system with a storage tank was about 450 dollars (1 dollar converted at 200 yen). This system offers more economy than the comparative system, which gave annual running costs of about 600 dollars. ~ GHP with HWST " 100 " ""'... -" 100 Gas furnace and room coolers ~ 0 Electric (main + "j:;... Gas (main) "' '".............,., 0 0 e so 2 50 "' "'.......,., 0 0 <J <J " " " 0 " 0 Oil........ g "' "' 9 10 11 12 1 ~ = 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 2 3 l Month Month Figure_!. ~omparison of monthly running cos_r:_ --- -------------- 116

7. CONCLUSION _ When the GHP system and the conventional system were compared according to thej.r energy performance and running cost, it became clear that t he GHP sys'tein offers advantages over its alternative. A more det:ailed economic study will follow later. REFERENCES (l) ASHRAE, Handbook 1985, Fundamentals Section IV. (2) The Society of Heating, Air-conditioning and Sanitation Engineers of Japan, Handbook II, 16-59, 1975. ANALYSE D'UN SYSTEME DE POMPE A CHALEUR ENTRAINE PAR MOTEUR A GAZ POUR USAGE DOMESTIQUE RESUME: Ce rapport decrit un systeme de pompe a chaleur, entrainee par un moteur a gaz (c'est-a-dire un systeme GHP), qui est utilisee pour le conditionnement d'air et!'alimentation en eau chaude de deux pieces d'une maison d'habitation. Ce systeme GHP a ete mis au point en cooperation avec les services publis de distribution du ga~ (Gaz de Tokyo, Gaz d'osaka et Gaz de Toho). Le principe de construction du systeme, les conditions d'essai, les caracteristiques de fonctionnement et les evaluations economiques sont decrits dans de rapport. La chaleur recuperee du moteur est utilisee pour le chauffage de l'eau et le chauffage des pieces. Ce systeme est de type a haute recuperation d'energie, avec reservoir de stockage de la chaleur. Nous avons compare le systeme avec un systeme classique de chauffage d'eau et de conditionnement de pieces d'habitation par fourneau a gaz, a l'aide d'un programme de simulation en vue d'evaluer la consommation energetique de chacun des systemes. ANALYSIS OF A HEAT PUMP POWERED BY A GAS MOTOR FOR HOME-USE ABSTRACT The paper describes a heat pump system powered by a gas motor (a GHP system) that is used for air-conditioning and warm water supply of two rooms in a house. This GHP system was designed in cooperation with the gas-supply public services (Tokyo Gas, Osaka Gas and Toho Gas). The build-up principles of the system, as well as its testing conditions, characteristics of use and economic evaluation are described in the study. Heat recuperated from the motor is used to warm water and rooms. This system has a high energy performance, with a storage tank for heat. Thanks to a model and computer simulating program to evaluate their energy costs, we have compared this system with a conventional water warming and air-conditioning gas system. 117

Figure 2. GHP system components (a) Outdoor unit 118

Figure 2. GHP system components (b) Hot water storage tank 119

Figure 2. GHP system components (c) Indoor unit 120