Condumax II Hydrocarbon Dew-Point Analyzer

Similar documents
Condumax II Hydrocarbon Dew-Point Analyzer

Condumax II Hydrocarbon Dew-Point Analyzer

Condumax II Hydrocarbon Dew-Point Analyzer

Condumax II. Condumax II. Hydrocarbon Dew-Point Analyser. Automatic, on-line measurement of hydrocarbon and water dew point in natural gas

Moisture and Hydrocarbon Dew-Point Measurement

Moisture and Hydrocarbon Dew Point Measurement

Dew-Point Transmitters and Instruments

All icon products are. Easy to use: with an intuitive glass touch-screen, wipe-clean graphic user interface with multi-language options.

On-line Side Stream Oil in Water Analyser - Model OIW-EX 100 or OIW-EX 1000

Promet I.S. Promet I.S. Process Moisture Analyser

In-line Oil in Water Analyser - Model OIW-EX100P and OIW-EX1000P

icount Oil Sampler (IOS) Portable Condition Monitoring for Hydraulic Oil and Fuel Systems

FLEXIBLE, AFFORDABLE, HIGH SPECIFICATION OXYGEN GAS ANALYSIS DESIGNED FOR DEMANDING HAZARDOUS AREA PROCESS CONTROL APPLICATIONS.

APPLIED. OMA-300 Hydrogen Sulfide Analyzer H 2. Ex p. Ex d. The world s safest continuous H 2. S analyzer. The OMA continuously measures H 2

THE STANDARD OF EXCELLENCE WDG-V SERIES COMBUSTION ANALYZERS

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Accurate, cost-saving and reliable Natural gas analyzer SITRANS CV SITRANS CV. Answers for industry.

APPLICATION DATA SHEET

OMA-300 Process Analyzer

Connected Industrial. EC 350 PTZ GAS VOLUME CORRECTORS ENABLING PRECISION GAS MEASUREMENT Proven Technology. Superior Performance.

MICHELL GROUP. Advanced Industrial Hygrometry and Process Instrumentation. Company Profile, 2011

Series 3300 TELEDYNE ANALYTICAL INSTRUMENTS. The 3300 series of low cost, microprocessorbased

EC 350 PTZ Gas Volume Correctors Enabling Precision Gas Measurement

Model D12-IR. Digital Gas Transmitter...

Dräger Polytron 8000 Stationary gas detector (EC)

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY

A New Standard of Excellence

APPLICATION DATA SHEET

Process Gas Chromatograph

SUPREMATouch. Modular Fire & Gas Detection System

CALIDUS tm the Modular micro Gas Chromatograph

Pre-engineered Sample Systems for TALYS ASP400 series with fiber optic interface

Parker icount Oil Sampler (IOS)

AS950 REFRIGERATED SAMPLERS

Industrial Grade Gas Detection Detecting The Difference

PUV, PIR and PFO Series BROCHURE

For Complete Fire and Gas Solutions

continuous emissions monitoring Combustion & Environmental Monitoring

Flexible Air-sampling Smoke Detection

Technical data sheet TDS0060

Dew Point Mirror 373. High Precision. Fast Response. Wide Measuring Range. Laboratory Reference. Touch Screen. Full Color High Resolution LCD

Eliminating False Alarms in Toxic Gas Detection. Jason Schexnayder Sales Manager - Americas

Datalogging as standard

for Drinking Water Systems

OLCT 700 & 710. Certifications FIXED GAS DETECTION. Better detection. Better protection.

Zareba Sensepoint Pro

WASTEWATER Online UV%Transmission Analyzer

APPLIED. OMA-406R Rackmount Process Analyzer

SOLUTION CATALOG Kytola Oval Flow Oil Lubrication Monitoring System

SENSE Instruments CO., LTD. Data sheet Gas detector Page 1 / 5. Gas detector

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

Process Gas Chromatograph

AS950 ALL-WEATHER REFRIGERATED SAMPLERS

SIL 2. Ultima X Series Gas Monitors CERTIFIED

SEC SIGNATURE ETO MONITOR TRAINING SENSOR ELECTRONICS CORPORATION

Enraf Servo Gauge 854 XTG

Controllers, Indicators & Set Point Programmers

EMS510 PS-1 COMPLIANT OPACITY/DUST MONITOR

MX43. Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. Cost savings on wiring installation

Danfoss gas detection unit Type GD Heavy Duty

Dräger Polytron 5700 IR Detection of flammable gases and vapours

CO 2 Laser. High Reliability and Performance

EasyLog Data Logger Series

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

COBRIX3 multibev. Online Beverage Analyzer. ::: Unique Density & Concentration Meters

APPLIED. OMA-206P Portable Process Analyzer. A window into your process since 1994.

Mass Sensors, Inc. Profile. Applications. Technology Baur Blvd, St. Louis, MO (314)

Wallace & Tiernan Controllers & Analysers ChemTrim Disinfection Controller

YOUR PARTNER IN FIRE & GAS DETECTION

HPLC Column Ovens and Temperature Controllers

Dependable Solutions for Gas Detection

Hydrazine Analyzer Series 2171 Specifications

Analyze IT Zirconia Oxygen Analyzer for Small Boiler Applications

SUPREMATouch Modular Fire & Gas Detection System

HART XL High Sensitivity Smoke Detection

Dräger Flame 2500 Flame Detection

Turbimax CUE21 / CUE22

GasGard 100 Control System

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

Industrial Grade Gas Detection

intrinsically safe detector for hydrocarbon gases

DET-TRONICS. SPECIFICATION DATA Eagle Quantum Premier Fire and Gas Detection / Releasing System APPLICATION FEATURES

Industrial Grade Gas Detection

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

Series 9000 Total Hydrocarbon Analyzer

Process Alarm Solutions

PANEL MOUNTED ELECTRONIC MULTI-CIRCUIT HEAT-TRACING CONTROL, MONITORING AND POWER DISTRIBUTION SYSTEM mm. 100 mm

High Pressure Conductivity Monitor

PRODUCT GUIDE. ionscience.com Unrivalled Gas Detection.

Integrated Process Solutions. Series 49. Thermal Management System

SUPREMATouch. Modular Fire & Gas Detection System

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

Dräger Flame 2100 Flame Detection

The SharpEye 40/40I (IR3) Flame Detection

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

EasyLog Data Logger Series

Improve Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor...

VM-3000 Mercury Vapor Monitor

973 Dew Point Mirror. Portable Industrial Chilled Mirror Hygrometer. Typical applications: REFLECTING YOUR STANDARDS

Transcription:

Condumax II Hydrocarbon Dew-Point Analyzer Automatic, on-line measurement of hydrocarbon and water dew point in natural gas. Process Instruments Highlights Fully automatic on-line analysis Objective, highly repeatable measurement 0.5 C (0.9 F) hydrocarbon dew-point accuracy Fundamental chilled mirror principle Patented detection technique Self-cleaning No purge or cooling gas needed Optional water dew-point analysis ModBus RTU IECEx, ATEX, CCSAUS and GOST Ex certifications Applications Natural gas processing Protection of turbo-expander plant Gas quality measurements at custody transfer Transmission pipeline monitoring Confirmation and control of fuel gas superheat to turbine power plant

Process Instruments Hydrocarbon Dew Point: A Critical Natural Gas Quality Parameter For natural gas producers, pipeline operators and direct contract buyers, hydrocarbon dew point is difficult to measure and control but it is vital to avoid custody transfer disputes frequently resulting in shut-ins due to today s tighter contractual limits. Accurate hydrocarbon dew-point measurement and control has emerged as THE issue at gas quality conferences, including the AGA. The need for harmonization of analysis methods to ensure consistent best practice is being promoted by research groups within independent organizations such as API in North America and GTE and GERG in Europe. These groups are evaluating the relationship between direct hydrocarbon dew-point measurement, the manual Bureau of Mines (BOM) method, potential hydrocarbon liquid content (PHLC) and analytical techniques such as gas chromatography (GC) with various Equations of State (EOS) software packages. The direct chilled mirror technique incorporated in the Michell Instruments Condumax II is the definitive method of measuring hydrocarbon dew point, and is preferred by most gas producers, pipeline operators and direct contract buyers around the world. Since 1986, the original Condumax enabled users to make direct fundamental measurements automatically, on-line, with minimal maintenance demands in service and with a level of objectivity previously impossible to achieve. Condumax II extends this capability, adding the latest features and specifications to a proven and patented measurement technique. Condumax II offers the user the opportunity to standardize on a hydrocarbon dew-point measurement technology that provides excellent correlation to PHLC, EOS calculations of extended composition analysis by laboratory GC and the BOM method in an instrument that is simple to install and virtually maintenance free. The Dark Spot Measurement Principle Condumax II uses a patented chilled mirror optical measurement technique that is radically different to that of any other instrument. Sensitivity of better than 1 ppm molar (1mg/ m 3 ) of condensed hydrocarbons enables the analyzer to detect the almost invisible films of condensate that are characteristic of hydrocarbon gases at dew point, due to their low surface tension and colorless appearance. The result is a breakthrough in accuracy and repeatability. The optical sensor comprises an acid etched, semi-matt stainless steel mirror surface with a central conical-shaped depression, which is chilled during a measurement cycle. Collimated visible red light is focused onto the central region of the optical surface. In the dry condition, the incident light beam is dispersed by the matt surface providing a base signal to the optical detector. During a measurement cycle, hydrocarbon condensate is formed on the optical surface and it becomes reflective due to the low surface tension of the condensate. An annular ring of light forms around the detector and there is a dramatic reduction in the scattered light intensity within the central Dark Spot region. This secondary effect is monitored and interpreted. The Dark Spot detection technique utilizes the physical characteristic of hydrocarbon condensate that makes it so difficult to detect in a manual visual dew-point meter (BOM). When a predetermined layer of condensate has been detected, the instrument records the temperature of the optical surface as the hydrocarbon dew point. In the subsequent recovery cycle, the optical surface is actively heated typically to +50 C (+122 F) to evaporate the condensates back into the flowing gas sample. This fully automatic process is complete in under ten minutes. Sensor Cell The design of the Condumax II sensor cell is critical to its dynamic performance. This cell combines the optical detection system, Dark Spot sensor, thermocouple and three-stage Peltier heat-pump in a stainless steel cell assembly. The cell carries an operating pressure rating of 100 barg and achieves a measurement depression range (ΔT) of up to -55K from the analyzer operating temperature. Flow De-coupling A flow de-coupling method is used in order to achieve maximum accuracy. Discrete measurement cycles, at user definable intervals, lock a fixed sample of the hydrocarbon gas mixture into the sensor cell. As the optical surface is chilled, sequential condensation of hydrocarbon components occurs with the heaviest hydrocarbons condensing first. Thus a flowing sample would lead to a falsely high indication of the hydrocarbon dew-point temperature of the gas. The fixed sample method used in the Condumax II ensures representative condensation of all hydrocarbon components and prevents preferential drop-out of heavy ends that occur with flowing samples often used by other measurement methods. Dark Spot Measurement Principle

Intelligent Control The Condumax II has a fully automatic, intuitive and intelligent control system that improves accuracy, sensitivity and reproducibility under any operating condition. A three-stage Peltier heat-pump under powerful digital command allows Condumax II to vary its chill rate to enable detection of the smallest amount of condensate on the optical surface. During start-up, Condumax II will perform a measurement cycle at a standard chill rate in order to range-find the hydrocarbon dew-point level. On subsequent cycles, the previous measured value is used to determine an optimized chill rate that will cause the sensor surface to cool quickly in the initial phase, but reduce its chill rate to 0.05 C/sec (0.09 F/sec) as it approaches the hydrocarbon dew point. This gives the user previously unattainable levels of precision and reproducibility and allows easy harmonization with other HCDP measurement techniques or measurement practices of individual users. Condumax II can also operate in Condensate Mode in order to give reliable PHLC measurement. In conventional dew-point measurement mode, analysis is performed at the cricondentherm condition or at user required pressure level. Sampling system features Microporous membrane filter Heated pressure regulator Heated enclosure Sample connections Optional combined water and hydrocarbon dew-point analysis 0.5 C (0.9 F) hydrocarbon dew-point accuracy Fully automatic on-line analysis ModBus RTU Condumax II also enables the user to determine the phase envelope of their gas through direct measurements at varying pressures. Condumax II is designed for easy operation, with innovative touch-screen control of all functions through the simple user menu that can be viewed in complete safety within the hazardous area environment on the high-resolution vacuum fluorescent alphanumeric display. Condumax II Sampling System (outdoor version) Condumax II Sampling System 2015 Michell Instruments

Process Instruments System Description Main Unit The Condumax II Main Unit contains all of the critical components in a single explosion proof/flameproof enclosure for installation in Zone 1 or 2 (Class 1, Div. 1 and 2 areas). The Dark Spot sensor cell and optional water dew-point sensor are mounted inside the unit in conjunction with the pressure transducers, flow switches, measurement electronics and display. Flame arrestors on the gas inlet and outlet ports provide safety protection. Electrical connections are made through cable glands at the base of the enclosure. The main unit is a fully functional hydrocarbon dew-point analyzer and requires only a clean, pre-conditioned gas sample and AC power for its operation. Simultaneous Water Dew-Point Analysis Water dew-point measurement is of equal importance to hydrocarbon dew point for all gas producers and pipeline operators. Optional second measurement channel utilizing the advanced Michell Ceramic Moisture Sensor, proven in over 1,000 petrochemical natural gas plant installations worldwide, to provide continuous on-line analysis to enable Condumax II to confirm conformance to both dew point gas quality specifications. Condumax II Main Unit Sampling System Indoor and outdoor sampling systems are available, providing comprehensive sample conditioning of natural gas at any pressure up to 138 barg for the standard design. The sampling system includes pressure regulation, flow control and most importantly micro-porous membrane filtration with by-pass arrangement and condensate drain to give fast response and protection from liquid hydrocarbon/glycol contamination. Dual channel sampling is available for the combined hydrocarbon/ water dew point analyzer package. The outdoor version is housed in an IP66 rated, insulated stainless steel enclosure. Thermostatically controlled heating ensures reliable operation with no condensate or water dropout prior to measurement. For both the indoor and outdoor sampling systems, the Condumax II Main Unit is mounted integral to the Sampling System. Human Interface The Condumax II is designed to be flexible in terms of measurement display and connectivity to other equipment. As standard, Condumax II provides a multi-function vacuum fluorescent display on the Main Unit that shows all measurement parameters and allows the user to adjust certain control parameters, view log data, max/min statistics etc. In addition, Condumax II provides two 4 20 ma outputs, configurable from the Main Unit user interface for any combination of measurement parameters. A digital output using ModBus RTU protocol is provided, for connection to an external computer, DCS or PLC system located in a safe area. Active X controls are an available option for integration in DCS systems. Optional Condumax II Remote Interface Remote Interface For users that wish to have a dedicated host within their Control or Instrument Room, the optional Remote Interface (RI) provides advanced graphical display of measurement and status information, data logging and all programme configuration functions for up to 31 analyzers. Each analyzer communicates with the RI through the ModBus RTU, so transferring all the functionality of the Main Unit through into the comfort and convenience of an indoor safe area environment. Additionally, global access to all functionality is provided through any web browser into the embedded unique IP address of the RI.

Process Instruments Technical Specifications Hydrocarbon Dew-Point Measurement Measuring technique Sensor cooling Maximum range Accuracy Sample flow Measurement frequency Dark Spot fixed sample analysis. Direct photo-detection of hydrocarbon condensate at hydrocarbon dew-point temperature Automatic via 3-stage Peltier effect electronic cooler under adaptive control Up to Δ -55K measurement depression from Main Unit operating temperature ±0.5 C hydrocarbon dew point (single and multiple condensable component analysis) 0.03 m 3 /hr (0.5 Nl/min) - alarm standard 6 cycles/hour (recommended) 12 cycles/hour (maximum) Water Dew-Point Measurement (optional) Measuring technique Units moisture content Resolution Range (dew point) Accuracy (dew point) Sample flow Michell Ceramic Moisture Sensor C and F water dew point; lbs/mmscf; mg/m 3, ppm V 0.1 C, 0.1 F Calibrated from -100 to +20 C (-148 to +68 F) ±1 C (1.8 F) from -59 to +20 C (-74 to +68 F) ±2 C (3.6 F) from -100 to -60 C (-148 to +154 F) 0.06 to 0.3 m 3 /hr (1 to 5 Nl/min) - alarm standard Pressure Measurement(s) Hydrocarbon dew-point analysis pressure Optional water dew-point process pressure Units Resolution Range Accuracy MPa, barg, psig 0.1 MPa and barg, 1 psig HC dew point: 0 to 100 barg (0 to 1450 psig) Water dew point: 0 to 200 barg (0 to 2900 psig) ±0.25% FS Hydrocarbon Dew-Point Analyzer Resolution Sample gas supply Enclosure Sample gas connections Operating environment Power supply Weight Integrated display/ keyboard Outputs Alarms Hydrocarbon and water dew point: 0.1 C (0.18 F) Natural gas up to 100 barg (1450 psig), pressure regulated in sampling system EExd cast enclosure with removable glass window viewing port. Internally heated for condensation protection 1/4 NPT female ports for both hydrocarbon and water dew-point channels; Sampling system: 6mm OD Std / 1/4 OD optional Indoors/Outdoors -20 to +50 C (-4 to +122 F) Max 95% RH 90 to 260 V AC 50/60 Hz, 125 W Main Unit; 300W c/w indoor sampling system; 400W c/w outdoor sampling system Main Unit 22.5kg (49.6lbs) ~42kg (92.6lbs) c/w Sampling system (indoor) ~57kg (125.7lbs) c/w Sampling system (outdoor) Touch screen with vacuum fluorescent display Modbus RTU, RS485 @ 9600 baud rate. Two 4-20 ma linear (non-isolated) outputs, user configurable for any combination of dew point or pressure parameters Process and analyzer status via software register and display annotation. Integrated low flow alarms for each sample flow. Analyzer status fault flag 23 ma on ma output 1 Certification Hazardous area certification ATEX: C CSA US Canada: USA: IECEx: *TC TR Ex (Russia, Kazakhstan & Belarus), Ukraine Ex certificate: Pattern approval II 2G Ex d IIB + H2 Gb Class I, Division 1, Group C, & D Class I, Division 1, Group B, C, & D Ex d IIB + H2 Gb Tamb -40 C to +45 C T4 Tamb -40 C to +60 C T3 1Ex d IIB+H2 T4, T3 Gb Tamb = -40 C to +60 C GOST-R, GOST-K, GOST-T, ukrsepro Remote Interface Optional for indoor safe area installation Host capacity Display User interface Function Ports Data download Remote access Power supply Plant control integration Up to 31 Michell EExd Process Instrumentation Range analyzers in any combination of models via Modbus Backlit color 15cm/6 LCD Integral mouse, on-screen keyboard View and modify analyzer operating settings; Record parameters to file and view virtual chart recorder analyzer diagnostics LAN, USB2, Modbus Retransmission CSV (comma separated variable) format for easy import to Excel OPC (OLE for Process Control) over a LAN Imbedded web page/unique IP address for PC access. Remote data reading via modbus RTU 100 to 280 V, 50/60 Hz ActiveX components to be used by software programmers for integration of Modbus protocol into a general plant software system *Available to customer specific order (consult Michell Instruments) For full details of configurations and options, please refer to the Condumax II Order Codes list. Available from the Michell Instruments website or from your local Michell Instruments office. Condumax II Transportable Hydrocarbon & Water Dew-Point Analyzer A complete transportable natural gas dew-point analysis system for field spot-check measurements. Periodic online operation when located in a temperature maintained analyzer house. Measurements and functionality are instantly accessible through integrated alphanumeric display and touch-glass HMI interface including log of dew point readings for operator review. For more information, please contact your local Michell Instruments office, or visit our website.

Main Unit Remote Interface 245mm 9.65 270mm 10.62 450mm 17.72 355mm 13.98 290mm 11.42 318mm 12.52 236mm 9.29 465mm 18.31 10mm 0.39 465mm 18.31 310mm 12.20 102mm 4.02 38mm 1.50 256mm 10.08 178mm 7.01 Install with minimum 120mm gap Sampling Systems Indoor Versions Galvanized Steel Panel Condumax II HC and water dew-point analyzer with sampling system for indoor installation. Outdoor Versions Stainless Steel Enclosure Condumax II HC and water dew-point analyzer within sampling system for outdoor installation. Options fitted in version shown: Enclosure cooling and adjustable heating thermostat. General Note: Outline dimensions for HC dew point only versions are also the same as shown. Michell Instruments, Inc 319 Newburyport Turnpike, Suite 207, Rowley, MA 01969 Tel: 978 484 0005, Fax: 978 843 7669, Email: us.info@michell.com, Web: /us Michell Instruments adopts a continuous development programme which sometimes necessitates specification changes without notice. Issue no: Condumax II_97149_V6_US_0215 2015 Michell Instruments