OPERATING AND SETTING MANUAL

Similar documents
Product instruction manual Easymount Wide Format Laminators

SuperKlean Washdown Products

OPERATING MANUAL Gfp 255C Please read this manual carefully before operating!

VARIABLE SPEED GRINDER OWNER S MANUAL R MANUAL VERSION SERIAL #

HEDMAN The HEDMAN Company 189 Gordon St. Elk Grove Village, IL

BOILING UNIT REDITAP. Installation and User Guide. IMPORTANT: This booklet should be left with the user after installation and demonstration

FD 430 Envelope Sealer

OPERATING INSTRUCTIONS MIGHTYLAM 2700 ROLL LAMINATOR

Product instruction manual Easymount Wide Format Laminators

Ceiling Sweep Fan Assembly Instructions

Lifetime Limited Warranty

52 SAN LUCAS CEILING FAN

HEDMAN DI-50. Endorser Instructions. Hedman DI-50 Operators Guide

ASTRO ENVELOPE FEEDER AMC FOR HEIDELBERG PRINTMASTER INSTALLATION AND OPERATING INSTRUCTIONS

Product instruction manual Easymount Wide Format Laminators

Torrena 42 Ceiling Fan

3800 North Mill Road Vineland, NJ USA Tel: Fax: Web: Rev. A

Closomat Lima Vita installation & user guide

Camarillo 52 Ceiling Fan

TA-12. Tabbing System USER'S GUIDE

CEILING FAN OWNER S MANUAL

Technical Data. Name: ERIKA Automat fully automatic machine to divide and to round dough pieces of the same size

OPERATING MANUAL. BAK Thermoplastic Welding Technology AG 1

Part Nos.: Laminators

WAILEA OWNER S MANUAL

OPERATING & SERVICE PARTS MANUAL 700ES ENERGY SMART WRAPPER SERIES C

CEILING FAN OWNER'S MANUAL

Bentley II 13 in Ceiling Fan Owner s Manual. Bentley II Ventilador de Techo de 33 cm Manual del Propietario

3 in 1 Garden Vacuum 9255 Instructions for Use

Roanoke 48 in Ceiling Fan Owner s Manual. Roanoke Ventilador de Techo de 1,22 m Manual del Propietario

H uline.com 80" AUTOMATIC STRETCH WRAP DISPENSER FILM DELIVERY SYSTEM MACHINE DIMENSIONS ELECTRICAL SPECIFICATIONS

CEILING FAN OWNER S MANUAL

Hawkins 44 in Ceiling Fan Owner s Manual. Hawkins Ventilador de Techo de 1,12 m Manual del Propietario

52 BARSTOW CEILING FAN

CEILING FAN OWNER'S MANUAL

STEAM WALLPAPER STRIPPER MODEL HTW5

52 STRATHMERE CEILING FAN

EASY FEED LITE FRICTION FEEDER OPERATOR MANUAL. Rev

Easy-Lam School Budget Roll Laminator

Tower Fan NSTF-06MI IMPORTANT! KEEP FOR FUTURE REFERENCE. Instruction Manual. Please register your product on-line at

User Instruction Manual

45 Wide Format Hot and Cold Laminator

Florentine IV 56 in Ceiling Fan Owner s Manual Florentine IV Ventilador de Techo de 1,42 m Manual del Propietario

OPERATING INSTRUCTIONS. Automatic welding machine LARON Version 2.1

Operating Instructions Pigeon - Clay target launcher

MAYFIELD CEILING FAN LISTED E ITEM # MODEL #BTH44ABZC5C BTH44BNK5C Español p. 20 ATTACH YOUR RECEIPT HERE.

PRESSURE WASHER MODEL NO: JETSTAR 1750 OPERATION & MAINTENANCE INSTRUCTIONS. WARNING Read the instructions before using the machine PART NO:

OWNER S MANUAL VERSION 4.4 SERIAL # X-1 SINGLE LAYER PRESS. With EG-260 Variable Speed Grinder

Product instruction manual Easymount Wide Format Laminators

(3 plastic wire connectors,blade balancing kit, 2 extra mounting screws #10-32 for outlet box.)

18 INCHES, OSCILLATING STAND FAN

OWNERS INSTRUCTION MANUAL

XPS-ProDry User s Guide Dryer Base

getting the best from your new cleaner...

TA-12/HT12 Tabber. OPERATING GUIDE Revised:

The Extraordinaire OWNER S MANUAL. Orbital Ceiling Fan. Model No. OF110** READ AND SAVE THESE INSTRUCTIONS. Net Weight 14.5 lbs. or 6.59 kg.

TACH-IT MODEL #3568 SEMI-AUTOMATIC TWIST TIE MACHINE OPERATION MANUAL AND PARTS LIST

CEILING FAN OWNER'S MANUAL

C-IV 60 CEILING FAN READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 120V. 60Hz

Technical data. Bathroom/shower room installations. Water services (WRAS approved)

52 BERKSHIRE CEILING FAN

FD Heavy Duty Feeder for FD 280 Tabbing System

DELUXE OPERATIONAL MANUAL

Product Information. Brushes. Drum brace cable

Installation Instructions

THE QUALITY BRAND IN FANS

CEILING FAN OWNER'S MANUAL

Operating Manual. Combination Table Sealing Press. Series: Classic. CiMa-Pak Corporation Montreal Toronto New York. Telephone:

User s Manual and Operating Instructions

Multifunctional Food Processor User guide

PARTS LIST. CoverPro 900CP & 1000CP

LED ILLUMINATED MAGNIFIER

SHRIMP CUTTER AND DEVEINER

MALIBU STAR OWNER S MANUAL

2 Installation Instructions For Vari-Fan Ceiling Fans Installation Instructions For Vari-Fan Ceiling Fans 11

THE QUALITY BRAND IN FANS

Disposal Unit (BKSDU) Burger King Shortening. Operation, Service & Parts Manual BURGER KING BKSDU

Fig. 1. Bottle Height---Top of bottle MUST be at this height or slightly higher.

Glendale 52 in Ceiling Fan Owner's Manual. Glendale Ventilador de Techo de 1.32 m Manual del Propietario

Parts and Service Manual BURNISHER MODEL: MR , MR , MR , MR

BQ-260/260L. Important Information BOOK BINDER

Panel Fan Series Operators Manual (Galvanized and Polymer)

MAINTENANCE MANUAL TAIYO SEIKI CO., LTD.

Tempest TP420/180 Electric Pressure Washer

EHA Hoffmann International GmbH

THE BARCLAY HUGGER CEILING FAN INSTALLATION INSTRUCTIONS

Food Slicer Visit our website at:

Los Angeles Abrasion Machine HM-70A & HM-70AF

20 High velocity Air

662 Step-Saver User s Guide

52 CEILING FAN. Owner s Manual Models #50336, 50337

RSH2455G OPERATOR S MANUAL ELECTRIC QUIET CHIPPER SHREDDER

Manual / Handbuch Spare parts list / Ersatzteilliste

52 BAYTOWNE CEILING FAN

OPERATING & SERVICE PARTS MANUAL HDS-215 COMBINATION SHRINK SYSTEM

Laminator ZJY Series User Manual

WIDE AREA VACUUM MODEL PF2030 WARNING: OPERATOR MUST READ AND UNDERSTAND THIS MANUAL COMPLETELY BEFORE OPERATING THIS EQUIPMENT.

TB-390 Conveyor Stacker

BQ-260/260L. Important Information BOOK BINDER

WYND DC 54 CEILING FAN Installation Manual

Transcription:

COMPLETE SOLUTIONS FOR ON-DEMAND CD AND DVD PRODUCTION Speed Wrap Case Wrapper for CD or DVD Cases OPERATING AND SETTING MANUAL TP 000 156-1 -

Thank you for purchasing a JMV Robotique Speed Wrap OPERATING AND MAINTENANCE MANUAL Document Reference No. TP 000 156 (Rev 1.07) Production Standard T.ZZ 004 020 DVD Speed Wrap T.ZZ 004 021 CD Speed Wrap JMV Robotique ZI du Clos Aux Pois 6/8 Rue de la Closerie LISSES 91048 EVRY Cedex France Tel: 33 (0) 1 60 86 15 25 Fax: 33 (0) 1 60 86 10 74 Email: contact@jmvrobotique.com www.jmvrobotique.com TP 000 156-2 -

WARNING To avoid electrical shock hazards, unit covers should only be removed by authorised personnel. COPYRIGHT This document is the property of JMV Robotique and it may not be reproduced, copied or exhibited to a third party without the written permission of JMV Robotique. ENVIRONMENTAL PROTECTION Waste electrical products should not be thrown away with household waste. Please recycle where facilities exist. Check with your local authority or retailer for recycling advice. JMV Robotique reserves the right to amend or modify the specifications and design criteria applying to these products. TP 000 156-3 -

WARRANTY TERMS The DVD Speed Wrap is covered by the JMV Robotique standard warranty. WARRANTY EXCLUSIONS We will not provide warranty repairs if, in our opinion, the problem resulted from externally caused damage, use outside the product s specification, faults caused by inexperienced or non-approved repairers. The warranty does not cover the replacement of used consumables (or of parts which need periodic replacement during the life of the product as a result of the use made of them) unless the consumable itself is defective. Note: Heater blocks are not covered by the warranty. IF YOUR PRODUCT FAILS WITHIN THE WARRANTY PERIOD Prepare a description of the problem you have had Make sure you have your proof of purchase document (invoice or receipt) Contact your supplier Note: Throughout this manual reference is made to the DVD Speed Wrap. The procedure for the CD Speed Wrap is identical except where stated. TP 000 156-4 -

TABLE OF CONTENTS Section 1 SPECIFICATION 6 Section 2 INTRODUCTION AND INSTALLATION 7 2.1 Introduction 7 2.2 Installation 7 Section 3 OPERATION 8-16 3.1 Power 8 3.1.1 Powering Up 8 3.1.2 Emergency Stop 8 3.2 Heater Seal Temperature Control 9 3.3 Installing the Cello Roll 9-10 3.4 Threading the Cello Wrapping 10-12 3.5 Making Adjustments 13-16 3.5.1 Adjusting the Cello tension 13 3.5.2 Adjusting the Cello Position 13-15 3.5.3 Adjusting the Heater Temperature 15 3.5.4 Adjusting the wrapper for different DVD case widths 16 3.5.5 Adjusting the case width 16 3.5.5.1 Removal of the wrap tunnel cover 16 3.5.5.2 Adjusting the width 16-17 Section 4 Operating the Speed Wrap 18 Section 5 Long edge seal adjustment 19 Section 6 Spare Parts List 20-21 Diagram 1: Cello Cutter Assembly 22 Diagram 2: Cello Roll Support Assembly 23 Diagram 3: First Heater and Folding Finger Assembly 24 Diagram 4:Pusher Assembly 25 Diagram 5: Side Heater Assembly 26 Diagram 6: Electrical Components 27 TP 000 156-5 -

SECTION 1: SPECIFICATION Power supply: Fuse: Capacity: Duty Cycle: Dimensions: Gross Weight: Net Weight: Polypropylene required: 200/220Vac 50/60Hz 1000 VA 5 Amp 1200 per hour Continuous Height: 27 (685mm) Width: 44.5 (1130mm) Depth: 22.6 (575 mm) 320lbs (145Kg) 187.4lbs (85kg) Bi-Oriented Polypropylene (OPP) DVD Speed Wrap CD Speed Wrap Hopper capacity: 25 DVD Amaray cases 35 CD jewel cases Polypropylene size: Hub: 76.2mm (3 ) 76.2mm (3 ) Roll Length: 1500m / 4291ft 1500m / 4291ft Roll Width: 213mm(min) 215mm(max) 141mm(min) -142mm(max) 8.385 (min) - 8.46"(max) 5.55 (min) 5.59 (max) Roll Diameter: 240mm / 9.4" 240mm / 9.4" The Speed Wrap will only accept rolls up to a maximum diameter of 240mm (9.448 ). Polypropylene thickness recommended: 25 Micron 25 microns No. of cases per roll: 4800 approx. 4800 approx. Polypropylene wrapping material is available from JMV Robotique. TP 000 156-6 -

SECTION 2: INTRODUCTION AND INSTALLATION 2.1 Introduction The DVD Speed Wrap has been specially designed to provide a professional wrapping facility for DVD and Amaray type cases. The automatic operation is simple and effective using rolls of polypropylene wrapping material. The DVD Speed Wrap is a tabletop mounted unit, which can easily be transported if required. In order to achieve the very best result, ensure you are using polypropylene material to the exact size specified above. This can be ordered from JMV Robotique. 2.2 Installation Your DVD Speed Wrap has been fully tested at the factory and our Quality Control Department has ensured, before dispatch that it performs satisfactorily to the full specification. Carefully remove your DVD Speed Wrap from its shipping carton and verify that all parts are present. If there are missing or damaged parts contact JMV Robotique or an authorised partner immediately. You should find the following: DVD SPEED WRAP Manual Roll of polypropylene wrapping material Note: If your DVD SPEED WRAP is damaged during shipment, please contact the freight carrier first, then, contact your JMV Robotique partner/reseller or JMV Robotique. You should save your shipping materials so that if the need arises, you can return your DVD SPEED WRAP for service. This packaging was designed specifically for shipping your DVD SPEED WRAP. Other packaging may not be suitable. After unpacking, place your DVD SPEED WRAP on a flat and clear surface. The DVD SPEED WRAP will accept power from either 200/220v 50/60Hz. The power connection is made to the DVD SPEED WRAP via the power cable supplied. The power circuit should be rated in accordance with the national and local electrical codes. CAUTION: The machine may be damaged if an incorrect voltage is used. A good electrical ground must be connected to the DVD SPEED WRAP. TP 000 156-7 -

SECTION 3: OPERATION 3.1 Power 3.1.1 Powering Up After connecting to the power supply, power up the DVD SPEED WRAP using the switch situated on the side of the machine. Turn to On position The commands on the front panel of the machine are as follows: Left Heat Block Control Right Heat Block Control Front Heat Block Control Emergency Stop Button 3.1.2 Emergency Stop Start Button Heater On/Off switch Pressing the Emergency Stop at any time stops the unit mechanism. Note: It does not turn off the heater. To release the Emergency Stop, rotate the switch approximately 10 degrees clockwise. The Emergency Stop switch must be depressed and the main power disconnected before any adjustments are made to the unit. TP 000 156-8 -

3.2 Heater Seal Temperature Control Switch the Heater On/Off switch to the On position by turning the switch to the right. This allows the heaters to heat up. Each heater has been pre-set in the factory with temperatures suitable for a typical DVD case. It will take approximately 15 minutes for the heaters to reach and stabilize at this temperature. The top figure on the heater control indicates the actual temperature of the heaters. The bottom figure indicates the setting temperature. To change the temperature of a heater simply press the up and down arrow keys to change the setting temperature to that desired. Use up and down arrow keys to change setting temperature 3.3 Installing the Cello Roll Actual temperature Setting temperature Note: Ensure the unit is switched off before attempting to install a new Cello Roll. Loosen the screw and remove the stopper from the end of the Cello feeder shaft. Cello feeder shaft Loosen the stopper screw Stopper TP 000 156-9 -

Slide the roll of Cello onto the shaft. Ensure that the cello is pushed fully onto the shaft and that the cello sits on the stopper lip. Stopper Lip Slide cello onto shaft Secure in the cello in place by replacing and tightening the stopper the screw. Tighten the stopper screw 3.4 Threading the Cello Wrapping The roll of Cellophane needs to be threaded through the machine before powering up the wrapper. The diagram below shows how the Cellophane should be threaded through the machine. As per the line diagram, thread the Cello through the machine. If the unit is at the start of the cycle the Cello will feed easily vertically into the cutting area. TP 000 156-10 -

Note: When the unit is at the start of the cycle the DVD case pusher is fully retracted to the left and cannot be seen in the hopper. If the unit is not at the start of the cycle, thread the Cello into the wrapping tower/cutting station, hold the lever shown below to the right to allow the Cello access. Push this lever to the right Note: This lever will need to be operated if you wish to remove the Cello at any time from the tower/cutting station and the DVD Speed Wrap is not at the start of the cycle. The Cello needs to hang half way down the wrapping tower/cutting station. Use your fingers to pull the Cello down. Pull the Cello down The final stage of threading the Cello is to ensure that the Cello is in the correct area so it can be clamped by the wrapping mechanism. Note: Do NOT place any DVD cases into the hopper at this stage. The hopper should be empty. TP 000 156-11 -

To check the Cello is in the correct position, you can operate the unit in simulate mode. With the wrapper turned on hold down the green start button with your left hand and press the silver Cello setting button with your right hand. Green start button Silver Cello setting button The wrapper goes through the process of a single wrap, leaving the Cello at the correct position to begin a full wrapping cycle. Using these buttons you can index the wrapping mechanism slowly through the cycle. To ensure the unit is in the start position, wait until the pusher is fully retracted to the left i.e. it cannot be seen in the hopper. TP 000 156-12 -

3.5 Making Adjustments 3.5.1 Adjusting the Cello tension The tension of the Cello can be adjusted to achieve the wrap type you require. The tension is achieved by 2 bars which run on top of the DVD case the length of the wrapping chute. Note: Ensure the wrapper is switched OFF at this stage. To check this, place a case under the guides and run it along the length of them to feel whether the pressure is even. Cello tension bars If the guides on either side are not even, you can adjust their height by turning the screws shown below. To increase the Cello tension turn the screw anticlockwise to increase the weight on top of the DVD case. Turn screws to adjust height of guides 3.5.2 Adjusting the Cello Position Ensure the wrapper has been switched ON for at least 15 minutes to allow the heaters to have reached their pre-set temperatures. TP 000 156-13 -

Place a few DVD cases into the hopper. DVD cases in hopper Ensure you have enough cases in the hopper to cover the hopper sensor otherwise the wrapper will not operate. Hopper sensor Press the green start/stop button on the control panel and the cases in the hopper will be pushed forward one at a time through the wrapping mechanism. The first process sees the case mechanism wrap the polypropylene material around the case and seal it on the long edge. In the second process, the cases are pushed forward one at a time between the side folders and heaters and ejected at the right hand side of the unit in a fully wrapped condition. Note: The unit will require to wrap between 5 and 10 cases before it settles down. This is because the Cello needs time to run consistently in the guides. Once you have a wrapped 5-10 cases, look to see if the case end wraps (the short edges) need adjusting. If it appears that there is too much Cello on one side of the case and not enough Cello on the other, this indicates that the Cello is not positioned centrally on the feeder shaft. To move the Cello more towards the back of the wrapper, tighten the screw situated on the stopper. To TP 000 156-14 -

move the Cello more towards the front of the wrapper, loosen the screw and pull the roll towards you. Tighten screw moves Cello slightly to the right Loosening the screw and pulling the roll towards you moves the Cello slightly to the front. The long edge wrap is factory set and should never normally require adjusting, however, if the cello wrap does not align properly on the front overlap edge of the case, the operator can adjust the cello by moving the brush, as shown below, left or right. 3.5.3 Adjusting the Heater Temperature Under normal circumstances the temperature settings should not require adjustment. The correct temperature is around 130 C. However, should difficulty in obtaining a reliable weld be experienced, the settings may be adjusted via controls on the front panel. In other instances, the heaters might be too hot and may damage the case, in which case the heater temperatures should be lowered. Note: Care should be exercised not to set an excessively high temperature, which may result in damaged cases. The heater is locked to a maximum setting of 160 C. To increase or lower the temperature hold down the or button respectively for more than 3 seconds. The current value will be displayed and will start to change. When the desired value is reached, release the button and do not push any buttons for a further 3 seconds. TP 000 156-15 -

3.5.4 Adjusting the wrapper for different DVD case widths Note: This section does not apply to CD jewel cases as their dimensions do not vary. The DVD Speed Wrapper is set in the factory to work with a standard 192 mm wide DVD case. There are many different case widths and the unit may have to be adjusted to accommodate the case you wish to use. Note: Before commencing this adjustment switch off the unit and disconnect it from the mains supply. To check the adjustment, place a DVD case in between the Cello folders. The front to back movement should be between 0.5mm and 0.75mm. If it is too tight the Cello will be loose at the ends and pushed up away from the seal. If it is too loose, the wrap will be loose at the ends. 3.5.5 Adjusting the case width 3.5.5.1 Removal of the wrap tunnel cover To adjust the case width you first have to remove the plastic tunnel cover. Remove the 6 allen head screws and carefully remove the cover. Remove the 6 allen head screws 3.5.5.2 Adjusting the case width Place the case in between the Cello folders and again check the clearance. To adjust the Cello folder, loosen the 2 screws in each folder and move them in the required direction. TP 000 156-16 -

Loosen the screws to adjust case width ensuring you adjust both Cello folders equally and squarely NOTE: They must be adjusted squarely and both must be moved an equal amount. NEVER only move one guide. When you have completed adjustment, tighten the 4 screws holding the Cello folders and replace the tunnel cover. TP 000 156-17 -

4.0 Operating the DVD Speed Wrap Fill the hopper with up to 25 DVD cases. Press the green Start button. Wrapped cases come out here TP 000 156-18 -

5.0 Long edge seal adjustment Because DVD cases can vary in thickness, it may be necessary to adjust the wrapping film overlap as follows: Loosen the knob as shown below. Turn adjustment knob: Anti-clockwise overlap Clockwise to overlap Adjustment knob to increase the decrease the TP 000 156-19 -

6.0 Spare Parts List Rep. Quantity Description 151 12 Bearing 152 6 Foot 162 1 Bearing 164 8 Bearing 168 4 Bearing 169 4 Bearing 170 2 Rubber stopper 171 4 Bearing 200 18 Roll 604ZZ 201 8 Roll 262ZZ 202 1 Roll 608ZZ 203 28 Roll 6000ZZ 204 12 Ball slide 210A 5 Pinion 210B 3 Pinion 210C 1 Pinion 210D 1 Pinion 215A 1 Pinion 257 1 Button 301 1 security microswitch 305 1 24V Power supply 310 1 DC Motor 21 rpm 311 1 DC Motor 42 rpm 315 1 E Stop Button 318 1 Start pushbutton with light 321 4 Relay 322 1 2 position switch 323 1 Fuse socket 323 1 Front pushbutton 325 1 Main switch 331 3 Heater controller 333 3 Temperature Probe 334 3 Heater 220V 315W 400 2 Shaft 408 1 Belt 411 2 Rail for grip 412 1 Articulation shaft for grip 417 2 Bearing 418 1 Tube 419 4 Bearing 420 4 roll shaft for cutter arm 421 1 Rail to fix cutter 422 1 Fix cutter 426 2 Moving cutter 431+432 1 Right grip assmebly 431S+432S 1 Left grip assembly 437 2 Chain 446 1 Chain 447 1 Chain TP 000 156-20 -

449 1 Cover protection 453 1 Cover protection 455 1 Cover protection 500 1 Heater block right 500S 1 Heater block Left 503 1 Folder finger 503S 1 Folder finger 504 2 Nut for roll 505 2 shaft for upper folding 508 2 Cam 510 1 Front Heater bolck 512 2 Cam 520 14 Bearing 520A 2 Bearing 521 2 Shaft for front heater roll 522 1 Cam 523 2 Cam 526 1 Pusher 534 2 Shaft 540 4 Shaft 560 2 568 2 Cello hub 571 1 Shaft for tension roll 572 1 573 1 Shaft for cello roll 576 4 Cutter cam 585 2 Grip Cam 589 2 Spring Shaft 594 2 Spring shaft 595 4 Washer 596 2 Pusher Rail 597 1 Pusher Articulation 599 2 Rail for roller 602+603+604 1 Right Conformer assembly 602S+603S+604S 1 Left Conformer assembly 1032 3 Spring 1033 2 Spring 1034 2 Spring 1035 5 Spring TP 000 156-21 -

Diagram 1: Cello Cutter Assembly TP 000 156-22 -

Diagram 2: Cello Roll Support Assembly TP 000 156-23 -

Diagram 3: First Heater and Folding Fingers Assembly TP 000 156-24 -

Diagram 4: Pusher Assembly TP 000 156-25 -

Diagram 5: Side Heater Assembly TP 000 156-26 -

Diagram 6: Electrical Components TP 000 156-27 -

Supplied by: JMV ROBOTIQUE ZI du Clos Aux Pois 6/8 Rue de la Closerie LISSES 91048 EVRY Cedex France Tel: 33 (0) 1 60 86 15 25 Fax: 33 (0) 1 60 86 10 74 Email: contact@jmvrobotique.com TP 000 156-28 - Website: www.jmvrobotique.com