OPTICAL TIME-DOMAIN REFLECTOMETER

Similar documents
Certified Fibre Optic Specialist - Testing

FACULTY OF ENGINEERING LAB SHEET OPTICAL COMMUNICATION SYSTEMS EOP4066 TRIMESTER 1 (2013/2014)

Benefits of Enhanced Event Analysis in. Mark Miller

Fiber Optics for Todays Industry Applications

Optical Fibres ELEC8350

Ensuring the Health of Tomorrow s Fiber LANs Part II OTDR Trace Analysis Become an Expert Troubleshooter with Advanced OTDR Trace Analysis

Hands-On Fiber Optics ISP/OSP - Advanced Combo- Tech

The Optical Time Domain Reflectometry and the Fusion Splicer Laboratory exercise

Field Test Procedure for Optical Fibre Link Measurements

LAB REPORT SUBMISSION COVER PAGE ETN4106 OPTOELECTRONICS AND OPTICAL COMMUNICATIONS

A. General: Horizontal and backbone cabling shall be verified in accordance with ANSI/TIA/EIA-568-C and the addendum for fiber optic testing.

OFS IV Optical Fibre System

The Rise of Tier 2 Testing

Fiber Optic and CAT 5, 6, 7 and 8 Installer Premise Cabling

MTTplus Modular Test Platform

OTDR II. Tier-2 Optical Time Domain Reflectometer for Multimode and Single-mode Fiber Cabling

FLX380-30x FlexTester OTDR

Optical Time Domain Reflectometry (OTDR)

Hands-On Fiber Optic ISP / OSP Combo-Tech Splicing, Termination & Testing

OTDR - FHO5000-xxx. Optical Time Domain Reflectometer

PC474 Lab Manual 1. Terry Sturtevanta and Hasan Shodiev 2. Winter 2012

Hands-On CAT 5/6 & Fiber Optic Installer

VTI Services Technical Bulletin (TB) OTDR Measurement of Installed Optical Fibre Cabling Permanent Links and Links

VIEW500 FASTEST STANDARD OTDR

OPTICAL TIME DOMAIN REFELECTOMETER (OTDR): PRINCIPLES

PC474 Lab Manual Wilfrid Laurier University 1

MINI2 MOST ACCURATE COMPACT OTDR

Fibre Optic Basics FIA Summer Seminar 2014

ECP OPTICAL FIBRE SPLICING, TESTING AND COMMISSIONING REQUIREMENTS

RLH Industries, Inc. Cleaning and Testing Fiber Optic Cable. Reference Guide MD A 0507

M700-Series Multifunction OTDR

High cost performance choice

FTB-7400E Metro/CWDM OTDR METRO/CORE AND CWDM NETWORK FIBER CHARACTERIZATION

Link loss measurement uncertainties: OTDR vs. light source power meter By EXFO s Systems Engineering and Research Team

ASSMANN ELECTRONIC GmbH ASSMANN SYSTEM GUARANTEE. DIGITUS Professional Fiber Optic Cabling System. Appendix B - Provisions for acceptance

Reflectance, The Hidden Danger That Increases Bit Error Rates in Your Fiber Networks Denver, May 22nd, 2010

Fibre Specification Standards

STANDARD TEST PROCEDURE PRE-TEST QUALITY OF OPTIC FIBRE CABLE ON DRUMS TYPE OF CABLE :

OPTICAL TIME DOMAIN REFLECTOMETRY (OTDR) Dr. BC Choudhary Professor, NITTTR, Chandigarh

Noyes OFL 250B Specs Provided by

FTBx-740C-DWC TUNABLE OTDR C-BAND DWDM METRO ETHERNET LINK CHARACTERIZATION

EXECUTING HIGHLY ACCURATE FIBER MEASUREMENTS IN A FRACTION OF THE TIME

SECTION TESTING OF FIBER OPTIC CABLES

High cost performance choice

Acceptance Requirements. Fibre Optic Systems. Revised 12/2017. December 5th, Alexander Kölbel

VIEW500 USER-FRIENDLY STANDARD OTDR

STATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY SPECIFICATIONS FOR FUSION SPLICE AND SPLICE ENCLOSURE FIBER OPTIC CABLE

AV6416 OTDR. Product Overview: Main Features:

OPX-BOX. Platform Highlights. Software Support. Key Features

iotdr Series Portable OTDR Test Set iotdr Series OTDR Tester is entirely new portable product released by OPWILL.

Long-Range Displacement Sensor Based on SMS Fiber Structure and OTDR

MINI2. Inno Mini 2 Specs Provided by MOST ACCURATE COMPACT OTDR

OPX-BOXe Rugged, Pocket-sized Mini OTDR

FTTH NETWORK TESTING: REAL APPLICATIONS USING THE OLTS METHOD

Optical Time-Domain Reflectometry for the Transport Spatial Filter on the OMEGA Extended Performance Laser

FTS500 Series. Handheld OTDR Test Set.

SECTION TESTING OF FIBER OPTIC CABLES

M210 Multifunction Micro OTDR

Optical Return Loss Measurement by Gregory Lietaert, Product Manager

M210 Multifunction Micro OTDR

Intelligent Optical Link Mapper (iolm)

palmotdr Series Handheld OTDR

FlexScan OTDR With SmartAuto and LinkMap

INTERNATIONAL STANDARD

FLX380-30x FlexTester3 OTDR

Fibre Characterisation and FTTx New challenges

TECHNICAL - *All Pricing are Exclusive of VAT. Introduction to Fibre Optics for non-fibre Technicians (can also be done on-site) TARGET AUDIENCE:

SERIES G: TRANSMISSION SYSTEMS AND MEDIA, DIGITAL SYSTEMS AND NETWORKS Transmission media and optical systems characteristics Optical fibre cables

Fibre (TIA) Field Test Specification

A Quick Start Guide to Fiber-to-the-Antenna (FTTA) Installation and Maintenance Testing. Vol. 2 Tier 2 Certification

Flexibility, scalability andsecurity

May 28th, Réseau Fibré Métrologique à Vocation Européenne

Ensuring Cabling Performance in the Customer-Owned Outside Plant

HELKAMA. Optical Fibre Cables

palmotdr Series Handheld OTDR

A Quick Start Guide to Fiber-to-theAntenna (FTTA) Installation and Maintenance Testing. Vol. 2 Tier 2 Certification

OTP6123 Series. Handheld OTDR Test Set.

Basic Professional Fiber Optic Installation

Field Testing and Troubleshooting of PON LAN Networks per IEC Jim Davis Regional Marketing Engineer Fluke Networks

FHO5000 Series Triple-Proof OTDR

ACCESS Master MT9085 Series. Product Introduction

FTS510 Series. Handheld OTDR Test Set.

AQ7275 OTDR Optical Time Domain Reflectometer

Terahertz Technologies Inc.

Exercise 1. Introduction to Sensors EXERCISE OBJECTIVE

Fiber optic system for monitoring large earth structures

M700-Series OTDRs. or (800) , (603)

Datasheet Palm OTDR. Product Summaries

M310 Data Center OTDR

Detection of Solvents using a Distributed Fibre Optic Sensor

M310 Enterprise OTDR. Designed for Enterprise Network Testing, Troubleshooting and Documentation. or (800) , (603)

OptiFiber Pro OTDR Built for the enterprise

Correlation-based OTDR for in-service monitoring of 64-split TDM PON

Ensuring Cabling Performance in the Customer-Owned Outside Plant. Keith Foord Product Manager Greenlee Communications

OptiFiber Pro OTDR Built for the enterprise

FG-750 Client API SDN-READY INTELLIGENT OTDR

AV6419 BOTDR. Product Overview. Main Features

Sterlite Tech Academy Creating Smarter Network Professionals

VePAL FX300 Portable OTDR, Optical Power Meter, Visual Fault Locator, and Laser Source Test Set

FX150 OTDR. Platform Highlights. Key Features

Transcription:

Tallinn University of Technology Laboratory exercise 1 of Fiber Optical Communication course OPTICAL TIME-DOMAIN REFLECTOMETER Tallinn 2016

Aim of the laboratory exercise: The aim of this laboratory exercise is to introduce the Optical Time Domain Reflectometer (OTDR) measurement tool and parameters influencing the measurement accuracy. After the exercise, students should have a clear overview about the possibilities provided by the OTDR equipment for fault localization. The list of equipment is provided in the last section of this document. Preparation for the laboratory exercise Please note that sufficient preparation for this laboratory exercise is needed! The student is asked to study and prepare answers for preparation questions (see below) before coming to the lab exercise. The lab exercises are meant for practical introductory matter with real fiber optic devices and either lab report or defence of lab report is not necessary. Participation in the laboratory exercise is compulsory. In the beginning of each lab, these preparation questions are discussed through. If student fails completely without knowing any matter of correct answers, then student is asked to file a lab report with conclusions. Sufficient understanding of covered topics by these preparation questions is the basis of the successful completion of the lab exercise. Questions are following: 1. What kind of loss mechanisms can be present in the fiber optic communication link? 2. What device is OTDR (Optical Time-Domain Reflectometer) and why is it used by fiber optic network engineers? 3. What is the working principle of OTDR? 4. What happens with the propagating light in the fiber medium if we bend fiber too much? You can write your answers here: 2

IMPORTANT DISCLAIMER: Please note that before starting work with the laboratory equipment you are asked to confirm that you have read carefully the safety instructions for working in the lab and working with fiber optic communication equipment! A. The Optical Time-Domain Reflectometer (OTDR) Figure 1 Example of the OTDR trace interpretation 1. Loss events of the fiber optical communication link The test link consisting of multiple fiber spools and fiber patches is already set up in the laboratory exercise room. The link with connected OTDR should have the following configuration depicted in the figure 2. Spool 1 Spool 2 Spool 3 OTDR Optical patchcord with UPC connectors Figure 2 Test schema for the OTDR measurement a. Locate the link and connect the OTDR to it. b. the OTDR test. Analyse the test results by changing the pulse length parameters from 5ns, 300ns and 20ms. What about the measurement accuracy? Can you identify all events at all pulse lengths? c. Pick the optimum value for the pulse and span length and run the trace. Inspect the results very carefully. Note that there is some extra complexity in the fiber link that is not shown in the figure 2. What can you see on the screen and what can you do with that information? Sketch up a rough drawing in figure 3 of OTDR trace result and mark also the events on your drawing. Can you identify any negative attenuation events with OTDR? What are these? 3

Figure 3 The OTDR trace result d. After identifying the broken fiber patchcord, remove it from the setup and make new OTDR measurement. Have you removed the correct from the setup? e. Now remove the launch s and connect OTDR directly to the fibre. Do you see any differences compared to the previous measurements? Sketch up a rough drawing in figure 4 of OTDR trace result. Figure 4 The OTDR trace result 2. Reflectance a. Recover the schema used at exercise 1 and pick the optimum pulse and span length for the measurements. Inspect the reflectance on the event table and the trace view. Where does the reflectance occur? Where are they mostly reflected from? b. Remove all the spools and leave only one launch connected to the OTDR module as it is seen in the figure 5. Find the optimum parameters and run the trace. Inspect carefully the end of the trace. Could you explain the ghost reflectance? 4

OTDR Figure 5 Test schema for the ghost reflectance Optical patchcord with UPC connectors 3. Fibre bends a. Recover the setup used at exercise 1 and add a short patchcord between and the first fibre spool as it is shown in the figure 6. Pick the optimum pulse and span length for the measurements. OTDR Patchcord Spool 1 Spool 2 Spool 3 Optical patchcord with UPC connectors Figure 6 Test schematic for the micro- and macro-bend measurements b. Bend the small added patchcord in a multiple rings with diameters of 10cm, 5cm, and 1,5cm. Run the trace after every ring. What can you conclude? What would a micro-bend mean? 4. Inspection of the live fibres Televõrgu infrastructure a. Connect OTDR and box to Televõrgu Metro fiber as it is shown in the figure 7, run test and inspect the readings. Figure 7 OTDR test schematic for the Televõrgu metro fibre infrastructure b. Write down the readings and explain, what these events might mean in the real life. How long are the fibres? Do you see any imperfections on the infrastructure? 5

List of equipment: Optical fibres and handling tools: One to three fibre spools in Lab environment (ITU-T G652 standard based fibre, ITU-T G.655 compliant Corning LEAF (Non-Zero Dispersion Shifted Fiber) and Corning Metrocore optical fibers) One to four optical routes with variable lengths on Televõrgu Metro fibre in Tallinn area (all ITU-T G.652 compliant optical fibres) Fiberscope and necessary adapters Fibre cleaning equipment (cleaning cassette and cleaning sticks) Attenuators and patch cords/optical jumpers Optical identification and measurement equipment: Optical Time-Domain Reflectometer (OTDR) Dead Zone Eliminator or OTDR box 6