RFP # FIRE STATION ALERTING SYSTEM FOR THE CITY OF BLOOMINGTON FIRE DEPARTMENT

Similar documents
PROJ. NO SECTION PAGING, SPEAKERS AND HARD-WIRED CLOCK SYSTEMS

City of La Puente REQUEST FOR PROPOSAL ADDENDUM NO. 1

Building Emergency Response Scenario

THIS ADDENDUM MUST BE ACKNOWLEDGED.

Applying Performance-based Fire Alarm System Design Part 4

Situational Awareness for Life & Fire Safety. October 10, 2013

School Paging. IP/SIP Intercom and Paging. Prepared by: John Vellone

AlertWave. visiplex. From a Public Address System to an Emergency Communication System... The AlertWave system advantages:

For additional information please contact the Chesapeake Fire Prevention Office at or at

DOD FIRE SERVICE CERTIFICATION SYSTEM LESSON PLAN 7. Fire Alarm and Communication

Dear Retirement Board Director:

TrueCom. Building Communications Systems 5115-Series , Area of Rescue Communications System. Description

RENO-TAHOE INTERNATIONAL AIRPORT RENO-TAHOE AIRPORT AUTHORITY PURCHASING AND MATERIALS MANAGEMENT

ERS-3600B. PERS-3600B Personal Emergency Reporting System

CITY OF MILTON INVITATION TO BID (THIS IS NOT AN ORDER)

SUWANNEE RIVER WATER MANAGEMENT DISTRICT REQUEST FOR BID NO. 15/16-003AO FIRE ALARM SYSTEM INSTALLATION AND MONITORING.

SECTION HEALTHCARE COMMUNICATION AND MONITORING SYSTEM (NURSE CALL)

Florida Department of Transportation 1000 NW 111 th Avenue, Room 6203 Miami, Florida

Frequently Asked Questions

A1UL PERS. Personal Emergency Response System. For Technical Support Please Contact Your Service Provider Or Distributor

MEDICAL ALERT SETUP GUIDE

WIRELESS SOLUTIONS FOR RESIDENCES. A Group brand

CCDC EXPANSION PROJECT

CITY OF PORTSMOUTH Department of Public Works MUNICIPAL COMPLEX FIRE ALARM. Bid # Addendum #1

BID SPECIFICATIONS FOR (NAME OF ENTITY) COMMUNITY OUTDOOR WARNING SIRENS

Addendum # 2 Wicomico County Circuit Court Second Floor Renovations Date of Addendum: 2/6/2017

FIREFIGHTER II: FIRE DEPARTMENT COMMUNICATIONS COMMUNICATIONS: SKILL SHEET #2 Define and Demonstrate Fire Department Radio Procedure

Auditorium Stage Curtains TSC RFP 17-29

Independent Living without Leaving Home. Personal Emergency Reporting Systems from Linear

RFP-FQ18063/KKB-Replace Three Roofs, DC, MD AND VA GREETINGS

SAPLING EDUCATION SOLUTIONS

CITY OF TUTTLE REQUEST FOR PROPOSALS FOR OUTDOOR WARNING SIRENS

ALERiTY. Mass notification. Integrated IP-based network solutions

The WAVE Plus Instant Notification System for Schools and Colleges

Fire Alarm System Fundamentals

AlertWave Smart Wireless Solutions for Today s Campus Whether you are a large university

LONE WORKER SAFETY HOW DO YOU PROTECT YOUR LONE WORKERS? EMPLOYEE CHECK-IN SYSTEMS DON T WORK! YOU NEED AN IMMEDIATE NOTIFICATION SYSTEM

1. Attachment A Section A Product Specifications, #5 is being amended as follows:

Standard of Practice - Fire Alarm Systems. NOTE: Significant revisions or additions to the previous standards are highlighted in italics.

DCN: COMMUNICATIONS MANUAL CHAPTER 1 January 1, 1997 ALARM TRANSMISSION SYSTEMS

IP-based Building Management Control

SP40S-D. Kingfisher Company, inc. Features: Description:

Unified Fire Authority - Fire Prevention Bureau

NON-MONITORED EMERGENCY CALL SYSTEMS

Radio Communications Guideline

TrueAlarm Fire Alarm Systems

Cisco Safety Solutions for Education

2 Courage, Tradition, Determination, Teamwork, Loyalty, Honor, Dedication and Service.

PERS-3600 PERSONAL EMERGENCY REPORTING SYSTEM INSTALLATION & OPERATION INSTRUCTIONS

Approval to Enter Into an Agreement with Everbridge, Inc. to Provide a Mass Notification System in Stanislaus County

Fire alarm provisions for alerting the Fire Service


Date of Start and downloading the tender 12 sep 2018

STATEMENT OF WORK ELECTRICAL REPAIR / MAINTENANCE BUILDING PROJECT FDC RACCOON CREEK STATE PARK (BEAVER COUNTY)

POPE FRANCIS HIGH SCHOOL SPRINGFIELD, MA BID SPECIFICATION PUBLIC ADDRESS AND INTERCOM SYSTEM

Round Rock Independent School District

ADVANCED TECHNOLOGY, FLEXIBILITY, AND BUILT-IN SURVIVABILITY

DIVISION 26 ELECTRICAL SECTION FIRE ALARM SYSTEM

NB/ 0695/MFFS/P 17A Feb 18 REQUEST FOR INFORMATION (RFI) FOR SUPPLY AND INSTALLATION OF MAGAZINE FIRE FIGHTING SYSTEM

ICC CODE CORNER 2015 International Fire Code

University Design Standard Fire Alarm Systems

Request for quotation (RFQ) for goods/services

ADDENDUM NO. 1. for. MARQUETTE HOUSING COMMISSION Pine Ridge Apartments Fire Alarm Replacement Project #A1140. Marquette, Michigan.

Type of Fire Alarm Control Panel: System is: Existing OR New If new, provide Electrical Permit Number:

Cold chain monitoring technologies. Facility monitoring

EMERGENCY COMMUNICATIONS SYSTEMS SUPPLEMENTARY RECORD OF INSPECTION AND TESTING

Surviving Survivability A User s Guide to Survivable Fire Alarm Circuits Larry D. Rietz, SET 23 May 2018

Update all extract references to NFPA documents (including NFPA 72) in Chapter 3 and related annex material to the latest editions.

Communications Committee SUBJECT: Dispatching System SUPERSEDES:

DIVA8MG2. Compact PAVA System Master Unit. DIVA8 System

FIXED PRICE BID (Open Response Date(s)) TERM CONTRACT EMERGENCY RESTORATION SERVICES Posting Date: April 18, 2017 :

REQUEST FOR PROPOSAL. Grounds Maintenance

We are heard everywhere. DSE electronic sirens

MAZAGON DOCK SHIPBUILDERS LIMITED

E911 Manual. Empowered by Innovation P/N E911. For additional resources, visit our Technical Support site on the web at

How to use the BTRM in Remote Enclosures

eight critical success 1. Reduce Response Time. 2. Minimize Firefighter Stress Levels 3. Improve communications.

SECTION NURSE CALL SYSTEM

Full Service Central Station Fire Alarm Listing Evaluation

PROGRAMMING PROCEDURES (Table 3)

A&E Specification Briefing. April 15, 2015

Low Rise Residential occupancies are required to perform one fire safety training and one evacuation drill annually

by Honeywell VOICE ALARM SOLUTIONS BROCHURE

SAPLING HEALTHCARE SOLUTIONS

Intelligent Security & Fire Ltd

E3 Series Broadband. Description. Features. Intelligent, Networked, Multi-Channel Fire Alarm Control and Emergency Voice Evacuation System

Print Specification. Publication. Instructions. Specific requirements. General requirements

1. The fire detection and alarm system (including the conduit) shall be a separate bid item and not part of the general electrical contract.

ADDENDUM NO. 1 BID-CONTRACT DOCUMENTS FOR. RFP No Professional Design Services for CCC Le-Jao Student Resource Center

Fire Service Communications

Connecting Emergency Alerting and Notifications with Federal Signal & Everbridge

Autonomous control unit

RFP Addendum 2 March 31, 2016

LEA COUNTY NEW MEXICO Page 1 of 8 JUDICIAL COMPLEX RFP NO.: 03-(16-17)

CALL FOR TENDER - MUNICIPALITY OF THE DISTRICT OF CLARE LITTLE BROOK, N.S.

1 Exam Prep Fire Alarm Signaling Systems Tabs and Highlights

REQUEST FOR PROPOSAL No Fire Extinguishers, Fire Suppression, Fire Alarms, Emergency Lighting & Sprinkler Systems Maintenance

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

DOWNLOAD OR READ : PANIC BUTTON PDF EBOOK EPUB MOBI

STREETSCAPE IMPROVEMENTS OF MARLBORO PIKE, COMMERCIAL BUSINESS DISTRICT (PART OF THE FAÇADE & INFRASTRUCTURE IMPROVEMENT PROGRAM PHASE II)

Transcription:

ADDENDUM NUMBER 1: January 23, 2014 RFP # 2014-36 FIRE STATION ALERTING SYSTEM FOR THE CITY OF BLOOMINGTON FIRE DEPARTMENT Unless explicitly noted below, all specifications will remain as originally prepared. Any variations or claims of equality or superiority must be demonstrated, proven and tested to the satisfaction of the City. A signed copy of this addendum must be submitted either: (a) With your completed proposal, OR (b) If you submitted your proposal prior to receiving this Addendum, you must return this addendum in a sealed envelope with the proposal identification clearly noted in lower left-hand corner of the envelope. The City will NOT return your submitted proposal; therefore, you MUST submit this addendum in a new envelope. 1) Exhibit A included in this addendum is the Drawings for Fire Station #2. You may email mshafer@cityblm.org to request a PDF of the Fire Station #2 drawings. You may request a CD be sent to you by USPS that includes drawings for all City of Bloomington Fire Stations by emailing mshafer@cityblm.org. 2) Exhibit B included in this addendum is copies of the Attendance Records for the Pre-Proposal Meeting held on January 15, 2014. 3) Where do you want the message boards located? Three boards will be needed, one each, in the hallways leading to the apparatus floor, and one in the living area. The exact locations will be decided with the selected vendor prior to installation. 4) Can interested bidders look at the dispatch area? Interested bidders may look at the Dispatch Center by appointment. Appoints must be made by contacting DC Les Siron. 5) What s the distance in between the equipment area and the dispatch area? The equipment room for the Dispatch center is directly below the center. I would estimate that it is no more than 50 feet to any console in the Dispatch center. 1

6) Do you have network connectivity between the stations and the call center? Yes there is network capability between the stations. 7) Is there wireless on site? Not at this time it is expected to be available in the next few months. 8) Are all phones and amplifiers connected? Yes in station #2 all of the Phones currently are connected to the amplifiers. 9) What lights come on with the current alarm system? Currently there are lights in the bedrooms, apparatus floor and throughout the station. 10) Do you want remote access? Please refer to System Monitoring on Page 41 of RFP 2014-36 11) What is the output for the CAD system? I have not had a response from New World at this time, so I do not have an answer for this question. According to their website, New World does have station toning and paging interfaces. 12) What outdoor speakers are there at each station? There are outdoor speakers at each station to alert members of the Department in smoking areas and parking lots. 13) Are you replacing any part(s) of the PA systems? The Fire Department is not replacing any part of the PA system unless it is required for installation of the Alerting system and part of the proposal. 14) Are you replacing any speakers? The Fire department has requested subdued lighting in the egress areas and the dormitory. If this requires replacement of current speakers then that should be part of the proposal. Any replacement of speakers to be compatible with the alerting system should be part of the proposal. 15) Are you looking for system timers? If so, what ones? On the doors? To monitor turn out times? Do these need to go back to the monitoring system? We are looking for Timers that the firefighters can observe as they turn out to reflect the time since the call was received at the station. These timers do not need to be monitored. 2

16) How are you currently responding to calls? Calls are currently being dispatched by Station for single company and ambulance response. Or by an all station alert when more than one company is dispatched or an apparatus is responding into another stations territory. Once the call is received the appropriate apparatus will respond and contact Dispatch via radio or electronically through the MDT 17) Do you want to be able to talk to dispatch or just use radios? All conversations with Dispatch will be over the radio. 18) Do you have workout rooms? Do you need notifications in those? Yes there is a workout room in the station. Audible and visual notification will need to be made in that room. 19) What kind of audio tones would you like? At this time the Department only requires the tones be ramped from a lower tone to a louder volume tone. The types available should be included in the RFP. 20) Is the current PA connection analog or digital? The Current PA system includes a PEAVEY 800T Pre Amp and an IPS 400 dual channel industrial Amplifier. These are analog units. 21) Can you provide details of the dedicated work station? I cannot answer this question because I am nt sure what is being asked. 22) Currently how are responses acknowledged? Currently the responses are acknowledged over the radio or electronically using the Mobile Data Terminal in all of the vehicles. 23) Do you want to be able to alert all stations? We need to have the capability to alert all stations 24) Do you want to bid just Fire Station #2 or all stations? At this time the bid is for Fire Station #2, an optional bid may be submitted including the other 4 stations. 3

EXHIBIT A 4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

EXHIBIT B 25

26

Firm Authorized Signature Date PLEASE NOTE: Failure to return the signed addendum with your sealed RFP will result in disqualification from this RFP. Misty Shafer, Procurement Specialist 01/23/2014 END OF DOCUMENT 27