Instruction Manual heater SH for SD dry cabinets

Similar documents
OPERATION MANUAL SDB Drying Cabinets

INSTRUCTION MANUAL SD and SDB Cabinets

INSTRUCTION MANUAL ESDA Cabinets with display

SD Storage Cabinet. Outstanding performance

SD Storage Cabinet. Outstanding performance

SDB Storage Cabinet

SD Storage Cabinet

HSD Dry Cabinet

HSD Dry Cabinet. Outstanding performance

HSD Dry Cabinet. Outstanding performance

Operation Manual for Drying Storage Cabinet with Drying Unit U-5002

Drying Cabinets and Vacuum Machines for Moisture Sensitive Components

MSD Cabinets. Modular Dry Cabinet. Outstanding performance

Drying Cabinets and Vacuum Machines for Moisture Sensitive Components

XSD Dry Cabinet. Outstanding performance. The XSD series has an outstanding performance for drying moisture sensitive components and pcb s.

Long Term Storage Cabinet

XSD Dry Cabinet

HEA USER MANUAL. 1 Version: 22. June 2010

XSD Dry Cabinet

OPERATIONS MANUAL. Hotplate Stirrer/Hotplate/Magnetic Stirrer Model HTS-1003/HTP-1002/MGS Certified

EUROSTER 11Z CENTRAL HEATING / UTILITY HOT WATER PUMP CONTROLLER

Instruction Manual Refrigerator-freezer

FE1 Explosion-Proof Electric Air Heaters

Inspection Light LED 6149/2. Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

Finned Tube Air Heaters Type WD/GG (RVS)

Tornado Operations & Maintenance Manual

General safety precautions English

General safety precautions English

MANUAL BOOK Sensor faucet

FX5 Series Explosion-Proof Electric Air Heaters

PC87 American Style Double Door Fridge Freezer Manual for Installation, Use and Maintenance

REFRIGERATED PREP TABLES Installation, Operation and Maintenance Instructions

Universal Fire Tube Boiler Wall Mount Models

EUROSTER 11E CENTRAL HEATING/UTILITY HOT WATER SYSTEM PUMP CONTROLLER

LARDER Instruction booklet

smeg LARDER Instruction booklet

Installation and operation manual

Zip Econoboil. On wall boiling water. Installation instructions & user manual. Model number: ,

Inverter Wall Mounted

Instruction Manual. Mini Hotplate Mini Stirrer Mini Hotplate Stirrer

Mobile Air Conditioner Instruction Manual Model TC-N9KM

1.0 INTRODUCTION 3 TABLE OF CONTENTS 2.0 FOR YOUR SAFETY Warnings and Safety Advice Coolants WARRANTY AND 3 CUSTOMER SERVICE 4.0 INS

User manual INFRARED REMOTE CONTROLLER SIR-15

Vinobox C 50 1T Vinobox C 50 2T

General safety precautions English

EUROSTER 11B UTILITY HOT WATER TANK PUMP CONTROLLER

Installation and Operating instructions for. C9900-U battery pack. Version: 2.0 Date:

D r ying printed circuit boards

PHOS 20 / LAP 20 LED PROJECTOR INSTRUCTION MANUAL

DETAIL SPECIFICATION SHEET

ULTRA LOW TEMPERATURE FREEZER. User Manual

User manual. Explosion-safe window air conditioning system Type series AR-054. II 3 G Ex ic nac h IIC T3 Gc

manual addendum DELPHI Ex

IMPORTANT INSTRUCTIONS READ & SAVE

U 5003 Drying Unit. Operation manual for cabinets with the U 5003 Drying Unit

THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE.

USER-MANUAL Tamson Cool Cube Immersion Cooler


ANTUS COLLECTION ADDITIONAL COMPONENTS. Instructions for Use & Installation. SKU Width HEIGHT Power Amps BTU.

FF820 freestanding full height larder fridge Manual for Installation, Use and Maintenance

Installation Manual. Instrucciones de instalación y manual de usuario 1

THERMASREG TR 040 THERMASREG TR 060

EUROSTER 11W CENTRAL HEATING SYSTEM CONTROLLER

Installation and operating instruction. Aircirculation Heater. Phoenix 2.8

IT-09 DATA PANEL. Operating manual ВІСТ НЕ

SDR Dry Room. Outstanding performance

Residential Gas Hybrid Water Heater

UNDERCOUNTER REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

Tissue-Tek TEC Plus Cryo Console OPERATING MANUAL

INLINE CENTRIFUGAL FAN. Centro-M OPERATION MANUAL

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

Gas Fired Residential Combi Boiler Floor and Wall Mount Models

LED Panel Light Specification List

User Manual. GPD 3000 e. gas detector

MENU. Steamist Digital Sauna Control Models: S170-1 and S Steamist Digital Sauna Control. Contents. 1. Steamist Digital Sauna Control

EUROSTER 1100E USER MANUAL 1 EUROSTER 1100E

USERS MANUAL. Desiccant Dehumidifier. Model: ECO DD322FW CLASSIC

Operating instructions

TIH 300 S / TIH 400 S / TIH 500 S / TIH 700 S / TIH 900 S / TIH 1100 S

Installation Instructions Remote Blowers

QUADRO COLLECTION COMPONENTS. Instructions for Use & Installation Plastic Anchor Threaded Wall Support Anchor Screw Threaded Long Tube

Solatube Daylight Dimmer Installation Instructions

9.9 CU.FT. TOP MOUNT REFRIGERATOR INSTRUCTION MANUAL. Model No.: HVDR1040W HVDR1040B HVDR1040S

Instructions manual DEHUMID HP50

IMPORTANT SAFETY INSTRUCTIONS

Elite. User s Information Manual. Elite and Elite VWH* All Models

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL

QXA2100. Condensation monitor QXA2101. Monitor to prevent damage caused by condensation on chilled ceilings and HVAC plants with AC/DC 24 V power.

Operating instructions for the radio heat detector GS412

Instruction Manual Mini Hotplate Mini Stirrer Mini Hotplate-Stirrer Mini Auto Stirrer Mini Fixed Temperature Hotplate

Instructions for installation

Tankless Water Heater

Instruction manual for slot-in wine cabinet

MENU. Steamist Xenio Sauna Control, Product: 0941 and 0942 Model: S170-1 and S Steamist Xenio Sauna Control. Contents

IMPORTANT INSTRUCTIONS READ & SAVE

OPERATION AND INSTALLATION

ULTRA-LOW HUMIDITY SEIKA. ERC Co., Ltd. ULTRA-LOW HUMIDITY STORAGE CABINETS 1%RH. Conforms to IPC/JEDEC J-STD-033D and IPC-1601 Guidelines.

Magnetic Stirring Systems with Heat

Installation and Operating Instructions

FF820 Freestanding Full Height Larder Fridge Manual for Installation, Use and Maintenance

Transcription:

Instruction Manual heater SH-230-4 for SD dry cabinets

Content: 1. Safety instructions 2. Application 3. Installation instructions 4. Temperature settings 5. Technical data 6. CE-Statement 1. Safety Instructions Please read the safety instructions carefully to prevent dangerous situations and damages on the dry cabinet as a result of inappropiated use.. switch of the power on the heater in case of burning smell or smoke. Don t try to repear the heater yourself, this will risk your garantue to void sh If a fluid leaked in the cabinet you have to disconnect the unit immediatly to avoid electric shocks. Switch off the power of the heater in case you have to make repairs or adjustments. Do not store inflammable or explosive materials or liquids in the cabinet. Do not use the heater in a moist or wet surrounding. Beware that the power supply cable doesn t get damaged as a result of been run over or otherwise is damaged. The heater can only be used in an upright position. Otherwise it can lead to damages or fire. Switching the main switch has to be executed with dry hands to prevent electrical shock. It is not allowed to put heavy materials on the heater otherwise the heater may tild. Hydrochloric acids, sulphuric acids or other acids cant be stocked in the cabinet because it can lead to corrosion. Should you have any questions about use of the heater please contact us.

2. Application The circulating hot air is specially adjusted on the configuration of the dry cabinet. As a result of the equable air distribution a uniform temperature is established in the dry cabinet. The heated air accelerates the drying proces of the stocked components because the moist air is removed faster from the cabinet as a result of the higher temperature. The proces is in accordance whith the IPC-JEDEC J-STD-033A standard and exceeds in the market all known processes. The danger of stronger oxidation of the components is prevented as a result of the relatively low temperature of 40 C. Therefore a Nitrogen System is not required and additional costs can be saved. Important notice: Heating the cabinet s atmosphere will affect the performance of the dry unit, which may temporarily result in higher humidity values inside the cabinet. Before putting the heater into operation the dry unit must be recycled once. This is done by switching the cabinet off and on again, to manually start the recycling procedure that will run about half an hour. 3. Assembly instructions Seen from the front the heater is mounted in the SD 1104/6 on the left backside of the cabinet 1. Remove all shelves. 2. Cover the dry unit before drilling holes to prevent a shortcircuit as a result of falling metal chips 3. Drill a hole of Ø 16,5mm on the outside of the backwall of the cabinet for the pass through of the power supply cable (Refer to drawing with recommended positioning oft he hole) 4. Mount the strain relief cable gland into the hole 5. Put the heater upright into the back left corner with the air outlets to the right. It will be held in position by 6 magnets that are fastened on the heater. 6. Pass the power supply cable through the cable gland and the power plug must be mounted by an authorized electrician according to the country s regulationsand specifications for electrical equipment.. 7. Replace the shelves 8. Acitivate the heater by turning the powerswitch

4. Temperature settings Factory preset maximum temperature of the heater is 40 C. Preset value: In running mode the display shows the ambient temperature within the cabinet. Press and hold the down button (2) for a short periode; the display will show SP1. It will blink for a couple of seconds. Factory set is 40ºC. To change the value one digit at a time, shortly press button (3) to increase or (2) for decrease. Holding the button longer than a second accelerates the speed to change the value more rapidly. 5. Technical Data When the new value is set as above, you don t have to enter. Just leave the unit for 15 seconds and the new temperature settings will be locked. The screen will return to show the ambient temperature within the cabinet. Voltage: 230V AC +/- 10% Frequency AC: 50/60 Hz Power: 780 W Temperature sensor: PTC 100 Thermal protection: 90 ºC Temperature range: 30 40 ºC Air Flow: 86 M³/H Display tolerance: 1 digit at 25 ºC

6. CE-conformation With this document we confirm: Totech Europe BV Linge 28 8252 PJ Dronten The heater unit is in accordance with the safety- and health regulations by EG-directives as mentioned below: EN55011: 1998+A1:1999+A2:2002 EN61000-6-2:2001 2006/95/EG 2004/108/EG Totech Europe B.V. Gerhard Kurpiela, Technical Manager