Differential relays 4.01

Similar documents
PRODUCT GUIDE. Relays. Differential Relays 46 Delta D2. Delta D4. Delta 48. Delta 72. Delta 96. Del. Del A

RM2S 2 module housing (sequence and phase-failure/asymmetry voltages)

DEB71. Earth Leakage Monitoring Relay. Benefits. Description

WD-CS. Water leak detection cable. Technical Overview. Features. Page 1. Data Sheet Ref: Issue: 5.1.

03.03.mmm REV.2 09/01

Water Detection Controllers

RD3 and RCQ020 Electronic low-voltage residual current devices for miniature and moulded-case circuit-breakers

OPERATING INSTRUCTIONS COP-IE, COP-I, COP-E (ANSI 50,51,50N,51N)

Temperature Controllers

CR Series Command Relays

Reyrolle Protection Devices. 7PG26 DAD High Impedance Current Relay. Answers for energy

02/11/2015

59T, 66T Series Electric Water Heater Controls

Serie Rugghölzli 2 CH Busslingen. Tel. +41 (0) Fax +41 (0)

Power Supply Display Module PSDM. Installation and Operation Manual

TECHNICAL DATA SHEET CONVENTIONAL FIRE ALARM SYSTEMS Conventional Fire Alarm Control Panel

Control and Annunciator Panels. Compact systems of signalling and control

INPUT / OUTPUT MINI MODULES

FDMM01S - FDMM02 - FDMM10- FDMM11S FDMM12 - Input / output mini modules

Table of Contents. Protective Relays

02/11/2015

MPU-32 MANUAL MOTOR PROTECTION UNIT

Instructions for the fan motor control system with integrated wiring terminals SILVER C

Reshaping Duct Smoke Detection

Ionisation single-tube smoke detector for duct mounting

59T, 66T Series Electric Water Heater Controls

ProRadiant Controls, Valves and Actuators

EBC20. Instructions for fitting, installation and operation. Read and save these instructions!

Tower & Obstruction Lighting

Modus Model DA General Eastern Low Differential Pressure Alarm Controller

La Marche Manufacturing Company Option 16 Series. Digital Combined Accessory Package. Installation and Operation Manual

ST Series. SELECTRONIC TATTLETALE Remote Alarm Annunciators

Tower & Obstruction Lighting Controls

EARTH LEAKAGE RELAY. User Manual - Issue 1.0

OPERATION & MAINTENANCE MANUAL GUARDIAN SPACE PRESSURE MONITOR WITH REMOTE AUXILLARY ALARM

ENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE

Safety Control Modules for Emergency Stop Circuits FF-SRS5988 FF-SRS5935 FF-SRS5925 FF-SRS5934 FF-SRS5924 TYPICAL APPLICATIONS APPROVALS DIMENSIONS

eed quality electronic design USER s MANUAL

1. Instruction. 1.5 Warranty Comar Condensatori S.p.A. guarantees its own products for twelve months from purchase

Model A1600 Series Annunciator

EC3-X33 Stand-alone Superheat Controller Technical Data

3.2 E1 Outdoor Unit PCB Abnormality E4 Actuation of Low Pressure Sensor E5 Compressor Motor Lock 3 52

Digital Heater Element Burnout Detector K8AC-H

Operation and use. Functions and characteristics

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

Communications None RS-232C RS-422* RS-485* BCD Transmission output*/** (4 to 20 ma) E5AX- E5AX- L(M)A02 L(M)A03

Process Alarm Module RTA 421

Electronic control unit for gas leak detection with 4 detection zones

Model A1700 Series Annunciator

AutomationDirect PM24. Microprocessor - Based Process/Temperature Limit Controller. Operator s Manual. Technical Support.

La Marche Manufacturing Company Option 46 Series. Digital Combined Accessory Package. Installation and Operation Manual

RTA421. Technical Information. Limit alarm switch Alarm switch and power supply for monitoring current or voltage signals

VAMP 120 & 121. Arc flash detection units. Product picture

Operating Instructions. For. Alarm Control Module. Model SSR 500

PSC-BL-I-FM-DC0(-BLE) Bi-level Dimming PIR Sensor

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content

DTA. Motor thermistor relay. Benefits. Description

Current monitoring relay, overcurrent, undercurrent and current window. MCU024R2, MCU230R2

SINGLE CHANNEL SYSTEM TWO CHANNEL SYSTEM

Selectronic Tattletale Remote Alarm Annunciators

7XG3120 ReyArc20 Arc Fault Monitor Relay Energy Management

DATASHEET. Burner control unit FDA 601x

GAS COMPONENTS ELECTRIC COMPONENTS WATER TECHNOLOGY MECHANICAL COMPONENTS TOOLS. Spare parts suitable for MIWE

ELECTROPROJECT GTV-A POWER SUPPLY FOR DOOR MAGNETS

CII FCAC-150 Series Relay

Multi-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC.

MD12-2 Vehicle Loop Detector

Capillary & Bulb Thermostatic Control & Fail-Safe Limit

USER MANUAL. SAFERA Connection Hub for SAFERA Siro IN-line and Siro R

UDC 700 Universal Digital Controllers and Indicator Specifications

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

BC3250. Blowdown Controller

INDEX APPLIANCE GAS WATER HEATER CONTROLS 150 ELECTRIC WATER HEATER THERMOSTATS 151 SNAP DISC CONTROLS/LIMITS/SWITCHES 152 GAS DRYER VALVES 153

Reshaping Duct Smoke Detection

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

IRIS IP65 IRIS UNISCAN APPLICATION MANUAL

DTA04. Motor thermistor relay. Benefits. Description

Series Digital Controller Instruction Sheet

Pump Logic User Manual CB-1000 P/N ILK-CB1000-1

RTD-10 Installation Instructions

B-40/B-41 Modulating Temperature Controller

GL-CO-RFG Channel Gas Leak Alarm System

Two-Channel Gas Controller

SERVICE INSTRUCTIONS FOR. Fire Alarm System MINI-2000

MD12-1 Vehicle Loop Detector

Model Number Structure

RE-PR3-E-27 3-Phase Panel Mount 27kW

Ordering Key. Dielectric strength

LED Driver Module. These instructions contain procedures to follow in order to avoid personal injury and damage to equipment.

SERVICE MANUAL MUZ-DM25VA - E1, ER1, ET1 MUZ-DM35VA - E1, ER1, ET1 OUTDOOR UNIT. No. OBH751. Models HFC R410A

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

Gate Operator. Modfications

PROTECT SRB 200EXi-1A

V. DIFFERENTIAL THERMOSTAT

AIS750 Series Alarm Annunciator User Manual (Ver. 2.3 / JUNE. 2014)

FireNET Plus Wiring Instructions

Intelligent addressable fire alarm control panel

Multi-Output Access Control Power Supply Chargers VDC or 24VDC VDC or 4 24VDC.

# amp # amp 12/24 VDC POWER SUPPLY INSTALLATION MANUAL. 4202/4MA, Rev. E 0804

SERVICE MANUAL OUTDOOR UNIT MUZ-FH06NAH MUZ-FH09NAH MUZ-FH06NA MUZ-FH09NA MUZ-FH09NA - 1 MUZ-FH09NAH - 1 MUZ-FH12NA MUZ-FH12NAH

Transcription:

Differential relays 4.01

Toroids for differential relays Model Del Del Codes TDGA2 TDGB2 TDGH2 TDGC2 TDGD2 TDGE2 TDGF2 Ordering codes see page: 07 07 07 07 07 07 07 Close-core toroids Ø 28mm 35mm 60mm 80mm 110mm 140mm 210mm Lowest current I n 0,03A 0,03A 0,03A 0,03A 0,1A 0,3A 0,3A Technical note NT641 Model Del A Del A Del Codes TDAA2 TDAB2 TDAC2 TDS5... Ordering codes see page: 08 08 08 08 Open-core toroids Ø 110mm 150mm 300mm - Lowest current I n 0,5A 0,5A 1A - Technical note NT641 NT641 NT641 NT642 In the event that problems with cable or bar sizes for the line to be protected do not allow to use above mentioned toroids (Ø hole max. 300mm), it is possible to use measuring current transformers with 5A (class 0.5 or 1) secondary winding together with a summation toroid TD55 manufactured according to the used C.T. ratios. For connection with toroids with ratio higher than 400/5A, the I n intervention current values which can be selected on the earth leakage relay are multiplied by 10. Model Delta TCS Codes ARD003 ARD00H Ordering codes see page: 07 07 Controlled circuits 1-2 selectable Controlled circuits voltage 20...440Va.c./d.c. Output relay 2 SPDT contacts Test manual Reset automatic A.C. auxiliary supply 230V 48V D.C. auxiliary supply - 20...150V Dimensions 4 module DIN Technical note NT817 Reliability of differential protection depends also on the switch opening circuit. Delta TCS monitors the release circuit working order for one or two switches with current launching coil. It reports the opening circuit breakdown by displaying the alarm (front LED s) and intervention of output relay. 4.02 overall dimensions page 09-10

Differential relays Model Delta D2-L Delta D2-s Delta D4-s Delta D4-I Codes RD1A RD3A RD1B. RD2B. Ordering codes see page: 06 06 06 06 Waveform I n type AC-A according to IEC/EN 60947-2 (annex B and M) ed. VIII (2007) 1 alarm 2 or 1 alarm + 1 pre-alarm 50% 2 alarms 19 ranges 0,03...30A Intervention time (t) 0/0,15/0,25/0,5/1/2,5/5s Intervention time R2(t) R1 + 0,4s Electrical block t=0 a 30mA Display I n on LED bar Filter for harmonics Enhaced filter for industrial uses 1 relay SPDT output 2 relay SPDT output field-selectable field-selectable field-selectable field-selectable positive/negative Relay status positive/negative positive/negative positive/negative (R2 allways negative) Test manual / automatic manual / automatic manual / automatic manual / automatic permanent permanent permanent permanent Reset manual or automatic manual or automatic manual or automatic manual (3 restart, 1 every 60s) (3 restart, 1 every 60s) (3 restart, 1 every 60s) A.C. auxiliary supply 24-48-115-230-240-400V 24-48-115-230-240-400V 24-48-115-230-240-400V 230V D.C. auxiliary supply 20 150V 20 150V 20 150-10...36V 2 wire Del - DelA connections Dimensions 2 module DIN 2 module DIN 4 module DIN 4 module DIN Technical note NT544 NT597 NT647 NT748 d.c. auxiliary supply and 48Va.c. auxiliary supply 24Va.c. overall dimensions page 09 4.03

Model Delta 48-s Delta 72-s Codes RD1DF RD1D2 RD1EP. RD1E2. Ordering codes see page: 06 06 07 07 Waveform I n type AC-A according to IEC/EN 60947-2 (annex B and M) ed. VIII (2007) 1 alarm 1 alarm + 1 pre-alarm 50% 2 or 1 alarm + 1 pre-alarm 50% 19 ranges 0,03...30A 18 ranges 0,05...30A Intervention time (t) 0/0,15/0,25/0,5/1/2,5/5s Electrical block t=0 a 30mA Display I n on LED bar Display I n on LED display Filter for harmonics 1 relay SPDT output 2 relay SPDT + SPST output 2 relay SPDT output Relay status field-selectable positive / negative field-selectable positive / negative Test manual / automatic permanent manual / automatic permanent manual or automatic manual or automatic Reset (3 restart, 1 every 60s) (3 restart, 1 every 60s) manual A.C. auxiliary supply 24-48-115-230-240-400V 48-115-230-240-400V 24-48-115-230-240-400V D.C. auxiliary supply 20 150V 20 150 2 wire Del - DelA connections Dimensions 48x48x102mm 72x72x75mm Technical note NT556 NT711 NT552 NT692 d.c. auxiliary supply and 48Va.c. auxiliary supply 24Va.c. 4.04 overall dimensions page 09

Differential relays Model Delta 72-h Delta 72-F Delta 96-s Delta 96-F Codes RD3E RD2E RD1G. RD2G. Ordering codes see page: 06 07 07 07 Waveform I n type AC-A according to IEC/EN 60947-2 (annex B and M) ed. VIII (2007) 1 alarm 1 alarm + 1 pre-alarm 50% 2 or 1 alarm + 1 pre-alarm 50% 19 ranges 0,03...30A 18 ranges 0,05...30A Intervention time (t) 0/0,15/0,25/0,5/1/2,5/5s Electrical block t=0 a 30mA Display I n on LED bar Display I n on LED display Filter for harmonics 1 relay SPDT output 2 relay SPDT + SPST output 2 relay SPDT output Relay status field-selectable field-selectable field-selectable field-selectable positive / negative positive / negative positive / negative positive / negative Test manual / automatic manual / automatic manual / automatic manual / automatic permanent permanent permanent permanent Reset manual manual manual manual A.C. auxiliary supply 24-48-115-230-240-400V 24-48-115-230-240-400V 24-48-115-230-240-400V 24-48-115-230-240-400V D.C. auxiliary supply 20 150V 20 150 20 150 20 150 2 wire Del - DelA connections Dimensions 72x72x75mm 72x72x75mm 96x96x92mm 96x96x92mm Technical note NT649 NT745 NT691 NT746 d.c. auxiliary supply and 48Va.c. auxiliary supply 24Va.c. overall dimensions page 09 4.05

Delta D2-L 1 threshold differential relay 2 module RD1AF11B 24Va.c. 1 alarm manual or automatic RD1AF12B 115Va.c. 1 alarm manual or automatic RD1AF13B 230Va.c. 1 alarm manual or automatic RD1AF14B 240Va.c. 1 alarm manual or automatic RD1AF15B 400Va.c. 1 alarm manual or automatic RD1AF1HB 20...150Vd.c. + 48Va.c. 1 alarm manual or automatic Delta D2-s 1 threshold differential relay 2 module RD3AF11B 24Va.c. 1 alarm manual or automatic RD3AF12B 115Va.c. 1 alarm manual or automatic RD3AF13B 230Va.c. 1 alarm manual or automatic RD3AF14B 240Va.c. 1 alarm manual or automatic RD3AF15B 400Va.c. 1 alarm manual or automatic RD3AF1HB 20...150Vd.c. + 48Va.c. 1 alarm manual or automatic Delta D4-s 2 threshold differential relay 4 module RD1B211B 24Va.c. 1 alarm + 1 pre-alarm or 2 alarms manual RD1B212B 115Va.c. 1 alarm + 1 pre-alarm or 2 alarms manual RD1B213B 230Va.c. 1 alarm + 1 pre-alarm or 2 alarms manual RD1B214B 240Va.c. 1 alarm + 1 pre-alarm or 2 alarms manual RD1B215B 400Va.c. 1 alarm + 1 pre-alarm or 2 alarms manual RD1B21DB 10...36Vd.c. 1 alarm + 1 pre-alarm or 2 alarms manual RD1B21HB 20...150Vd.c. + 48Va.c. 1 alarm + 1 pre-alarm or 2 alarms manual Delta D4-I 1 threshold differential relay 4 module RD2B213B 230Va.c. 2 alarms manual or automatic Delta 48-s 1 threshold differential relay 48x48mm RD1DF11B 24Va.c. 1 alarm manual or automatic RD1DF12B 115Va.c. 1 alarm manual or automatic RD1DF13B 230Va.c. 1 alarm manual or automatic RD1DF14B 240Va.c. 1 alarm manual or automatic RD1DF15B 400Va.c. 1 alarm manual or automatic RD1DF1HB 20...150Vd.c. + 48Va.c. 1 alarm manual or automatic Delta 48-s 1 threshold differential relay 48x48mm RD1D212B 115Va.c. 2 alarms manual or automatic RD1D213B 230Va.c. 2 alarms manual or automatic RD1D214B 240Va.c. 2 alarms manual or automatic RD1D215B 400Va.c. 2 alarms manual or automatic RD1D21HB 20...150Vd.c. + 48Va.c. 2 alarms manual or automatic Delta 72-h 2 threshold differential relay 72x72mm RD3E211B 24Va.c. 1 alarm + 1 pre-alarm or 2 alarms manual RD3E212B 115Va.c. 1 alarm + 1 pre-alarm or 2 alarms manual RD3E217B 230-240Va.c. 1 alarm + 1 pre-alarm or 2 alarms manual RD3E218B 400-415Va.c. 1 alarm + 1 pre-alarm or 2 alarms manual RD3E21HB 20...150Vd.c. + 48Va.c. 1 alarm + 1 pre-alarm or 2 alarms manual 4.06

Delta 72-s 2 threshold differential relay 72x72mm RD1EP11B 24Va.c. 1 alarm + 1 pre-alarm manual and automatic RD1EP12B 115Va.c. 1 alarm + 1 pre-alarm manual and automatic RD1EP13B 230Va.c. 1 alarm + 1 pre-alarm manual and automatic RD1EP14B 240Va.c. 1 alarm + 1 pre-alarm manual and automatic RD1EP15B 400Va.c. 1 alarm + 1 pre-alarm manual and automatic RD1EP1HB 20...150Vd.c. + 48Va.c. 1 alarm + 1 pre-alarm manual and automatic RD1E211B 24Va.c. 1 alarm + 1 pre-alarm or 2 alarms manual RD1E212B 115Va.c. 1 alarm + 1 pre-alarm or 2 alarms manual RD1E213B 230Va.c. 1 alarm + 1 pre-alarm or 2 alarms manual RD1E214B 240Va.c. 1 alarm + 1 pre-alarm or 2 alarms manual RD1E215B 400Va.c. 1 alarm + 1 pre-alarm or 2 alarms manual RD1E21HB 20...150Vd.c. + 48Va.c. 1 alarm + 1 pre-alarm or 2 alarms manual Delta 72-F 2 threshold differential relay 72x72mm RD2E211B 24Va.c. 1 alarm + 1 pre-alarm or 2 alarms manual RD2E212B 115Va.c. 1 alarm + 1 pre-alarm or 2 alarms manual RD2E213B 230Va.c. 1 alarm + 1 pre-alarm or 2 alarms manual RD2E214B 240Va.c. 1 alarm + 1 pre-alarm or 2 alarms manual RD2E215B 400Va.c. 1 alarm + 1 pre-alarm or 2 alarms manual RD2E21HB 20...150Vd.c. + 48Va.c. 1 alarm + 1 pre-alarm or 2 alarms manual Delta 96-s 2 threshold differential relay 96x96mm RD1G211B 24Va.c. 1 alarm + 1 pre-alarm or 2 alarms manual RD1G212B 115Va.c. 1 alarm + 1 pre-alarm or 2 alarms manual RD1G213B 230Va.c. 1 alarm + 1 pre-alarm or 2 alarms manual RD1G214B 240Va.c. 1 alarm + 1 pre-alarm or 2 alarms manual RD1G215B 400Va.c. 1 alarm + 1 pre-alarm or 2 alarms manual RD1G21HB 20...150Vd.c. + 48Va.c. 1 alarm + 1 pre-alarm or 2 alarms manual Delta 96-F 2 threshold differential relay 96x96mm RD2G211B 24Va.c. 1 alarm + 1 pre-alarm or 2 alarms manual RD2G212B 115Va.c. 1 alarm + 1 pre-alarm or 2 alarms manual RD2G213B 230Va.c. 1 alarm + 1 pre-alarm or 2 alarms manual RD2G214B 240Va.c. 1 alarm + 1 pre-alarm or 2 alarms manual RD2G215B 400Va.c. 1 alarm + 1 pre-alarm or 2 alarms manual RD2G21HB 20...150Vd.c. + 48Va.c. 1 alarm + 1 pre-alarm or 2 alarms manual Delta TCS Relay to check the switch opening circuit 4 module ARD003 230Va.c. 2 alarms automatic ARD00H 20..150Vd.c. + 48Va.c. 2 alarms automatic Del Closed-core toroid for differential relay Ordering code Inside diameter Stock TDGA2 28mm TDGB2 35mm TDGH2 60mm TDGC2 80mm TDGD2 110mm TDGE2 140mm TDGF2 210mm 4.07

Del A Open-core toroid for differential relay Ordering code Inside diameter Stock TDAA2 110mm TDAB2 150mm TDAC2 300mm Del Summation toroid for differential protection with measuring current transformer Ordering code Description Stock TDS5C100 Measuring current transformer 100/5A TDS5C150 Measuring current transformer 150/5A TDS5C250 Measuring current transformer 250/5A TDS5C400 Measuring current transformer 400/5A TDS5C500 Measuring current transformer 500/5A TDS5C600 Measuring current transformer 600/5A TDS5C800 Measuring current transformer 800/5A TDS5D100 Measuring current transformer 1000/5A TDS5D120 Measuring current transformer 1200/5A TDS5D125 Measuring current transformer 1250/5A TDS5D150 Measuring current transformer 1500/5A TDS5D160 Measuring current transformer 1600/5A TDS5D200 Measuring current transformer 2000/5A TDS5D250 Measuring current transformer 2500/5A TDS5D300 Measuring current transformer 3000/5A TDS5D320 Measuring current transformer 3200/5A TDS5D400 Measuring current transformer 4000/5A TDS5D500 Measuring current transformer 5000/5A 4.08

OVERALL DIMENSIONS RD1A... / RD3A... RD1B... / RD2B... / ARD... 65,6 89,5 45 70 44 2 Module 4 Module RD1D... 52 45 48 52 45 48 102 48x48 flush mounting RD1E... / RD2E... / RD3E... 75 68 72 75 68 72 A 72x72 flush mounting A = 75 RD1E.../ RD2E... A = 78,2 RD3E... RD1G... / RD2G... 92 96 92 96 92 12 96x96 flush mounting 4.09

Del TDGA2 TDG.2 / TDS5... B 28 100 6 10 C A E D 59 47 Weight 200g Model A B C D E Weight TDGB2 35 92 113 36 56 250g TDGH2 60 105 138 36 56 300g TDGC2 80 125 160 36 56 350g TDGD2 110 165 198 36 56 500g TDGE2 140 200 234 36 56 700g TDGF2 210 290 323 44 64 1200g TDS5... 80 125 160 36 56 400g Del A TDAC2 TDAA2 / TDAB2 S1 S2 S3 S4 C A 310 400 30 B 79 Weight 3,8kg Model A B C Weight TDAA2 110 235 219 2,35Kg TDAB2 150 275 259 2,5Kg 4.10