PROJECT: CUSTOMER: ENGINEER: PUMP MANUFACTURER: MODEL: APD REMOTE PANEL FOR DIESEL ENGINE DRIVEN FIRE PUMP DRAWING SUBMITTAL PACKAGE CONTENTS: BROCHURE DIMENSIONAL DATA WIRING SCHEMATICS FIELD CONNECTIONS NOTE: The drawings included in this package are for controllers covered under our standard offering. Actual AS BUILT drawings may differ from what is shown in this package.
APx SERIES Remote Alarm Panels For Fire Pump Applications
Built-in wall mounting lugs for ease of installation SERIES Remote Alarm Panels For Fire Pump Applications 4 alarm bell SERIES APx The Tornatech APx Series remote alarm panels are installed to provide annunciation of alarm conditions monitored at the fire pump controller. The NFPA20 standard requires that the annunciation of these alarm conditions be monitored at a point of constant attendance if the pump room is not constantly attended. Alarm Inputs from Fire Pump Controller (1 N.O) STANDARD FEATURES: NEMA 1 enclosure Bottom entry gland plate LED type visual indication Quantity 12 N.O inputs (Max. 8A - 240V.AC) Quantity 12 N.O or N.C outputs (SPST - Max. 8A - 240V.AC) 4 Alarm bell Silence pushbutton Lamp test pushbutton Gland plate Model APE For monitoring of a single electric fire pump controller Model APEE For monitoring of two electric fire pump controllers ELECTRIC FIRE PUMP PANEL ELECTRIC FIRE PUMP DUAL PANEL Alarm Outputs for remote annunciation (1 N.O - 1 N.C) Model APD For monitoring of a single diesel fire pump controller Model APDD For monitoring of two diesel fire pump controllers Model APED For monitoring of an electric and a diesel fire pump controller DIESEL FIRE PUMP PANEL DIESEL FIRE PUMP DUAL PANEL ELECTRIC & DIESEL FIRE PUMP PANEL POWER / PHASE FAILURE POWER / PHASE FAILURE POWER / PHASE FAILURE HAND OR OFF HAND/OFF - HAND/OFF - POWER / PHASE FAILURE HAND OR OFF - - - - - - RUNNING RUNNING RUNNING ENGINE RUNNING ENGINE RUNNING ENGINE RUN RUNNING ENGINE RUNNING AND AUDIBLE - Power / Phase Failure - Phase Reversal - Pump Room Alarm - Motor Trouble - Motor Running AND AUDIBLE - Power / Phase Failure - Pump 1 and 2 - Phase Reversal - Pump 1 and 2 - Pump Room Alarm - Pump 1 and 2 - Motor Trouble - Pump 1 and 2 - Motor Running - Pump 1 and 2 AND AUDIBLE - Main Switch in Hand or Off - Controller Trouble - Pump Room Alarm - Engine Trouble - Engine Running AND AUDIBLE - Main Switch in Hand or Off - Pump 1 and 2 - Controller Trouble - Pump 1 and 2 - Pump Room Alarm - Pump 1 and 2 - Engine Trouble - Pump 1 and 2 - Engine Running - Pump 1 and 2 AND AUDIBLE - Power / Phase Failure - Phase Reversal - Pump Room Alarm - Motor Trouble - Motor Running - Main Switch in Hand or Off Controller Trouble Pump Room Alarm Engine Trouble Engine Running
APx SERIES Remote Alarm Panels For Fire Pump Applications AVAILABLE OPTIONS: Additional visual indication (LED) and dry alarm contact (SPST- Max 8A 240V.AC) Visual indication (LED) and dry alarm contact (SPST- Max 8A 240V.AC) for controller with transfer switch. Fire pump start pushbutton 220V.AC supervisory power NEMA 2 enclosure NEMA 4 enclosure NEMA 4X enclosure CE Listing Labelling and drawing in other languages * For other options please contact factory. HOW TO ORDER: APD - Supervisory Voltage - options Ex.: APD - 120 - options The Americas Tornatech Inc. Head Office 7075, Pl. Robert-Joncas Suite # 132 Montreal, Canada H4M 2Z2 Tel.: + 1 514 334 0523 + 1 800 363 8448 Fax: + 1 514 334 5448 APx-BRO-001/E Rev.6 USA Sales Representative Tel.: + 1 513 307 6766 Fax: + 1 513 759 0509 Latin America Sales Representative Tel.: + 1 514 334 0523 Cell: + 1 514 945 4067 Fax: + 1 514 334 5448 July 2013 Printed in Canada Europe Tornatech S.P.R.L. Avenue Sabin 3 1300 Wavre Belgium Tel.: + 32 (0) 10 84 40 01 Fax: + 32 (0) 10 24 75 05 Middle East Tornatech Fz-Llc. P.O. Box 502221 Dubai, UAE Tel.: + 971 50 8574639 tornatech.com tornatech.com Tornatech Pte Ltd. 49B Tuas South Ave 1 Tuas Cove Asia Industrial Centre Singapore 637252 Tel.: + 65 6795 8114 + 65 6795 7823 Fax: + 65 6795 3201 info@tornatech.com