17.25 (438 mm) 37.5 (953 mm) 3.5 (89 mm) 3.0 (76 mm) 28 (711 mm) or 36 (915 mm)

SU5000. Optical Turnstiles. alvaradomfg.com

OptiStile 220. Swinging Barrier Arm Optical Turnstile

Custom options such as housing finishes and design, lid have their presence felt. A combination of sleek, sophisticated

ES860 OPTICAL TURNSTILE INSTALLATION AND OPERATION MANUAL PRESENT CARD

OptiStile 400. Non-Barrier Optical Turnstile

Bi-Directional Barrier Arm Turnstile

SpeedStile FP. Full-Panel Speed Gate with Sliding Glass Barrier

ARCHITECTURAL SPECIFICATIONS

OPTICAL TURNSTILE SYSTEM

The following modes can be set when the units are installed, and/or can be changed later through use of a push button on the desktop controller:

Users Manual. LAURUS Systems, Inc. - Ph: Fax:

Tripod Turnstiles. Tripod Turnstile for Public Transport Application

TD flex is an award-winning tailgate detection solution that prevents unauthorized access at: Doors Turnstiles Transfer gates Mantraps Airlocks

SlimStile BA. Tripod Turnstile for Internal Installation (*)

TD flex is an award-winning tailgate detection solution that prevents unauthorized access at: Doors Mantraps Airlocks E-gates Turnstiles

LUMA-NET 804CP / 808CP REMOTE CONTROL PANEL

Gunnebo SpeedStile BP. BA/EV Series. Bi-parting Speed Gate for Internal Installation

OPTICAL TURNSTILE SYSTEMS

TD flex is an award-winning tailgate detection solution that prevents unauthorized access at: Doors Turnstiles Transfer gates Mantraps Airlocks

SpeedStile FP/FPW. Full-Panel Speed Gate for Internal Installation

MODEL RLY-DIM-D INSTALLATION INSTRUCTIONS

ProTalk. Expander. Operating Manual Model B1292. July 28, 2009 Rev. 1.01

4040 FM 535 F :

Gunnebo SpeedStile BP. DS Series. Bi-parting Speed Gate for Internal Installation

RAM3 Remote Alarm Module

Crypto-Lock. Model CC-8521B Updated 7/17. Access Control System. MONITEQ, Inc. INSTRUCTION MANUAL

Safety & Installation Instructions

AIM TECHNICAL MANUAL PATENT PENDING STOP REMEMBER TO ACTIVATE UNIT BEFORE TESTING. See page 9 for Activation Instructions

VT SERIES VERTICAL TOASTER OPERATOR S MANUAL TABLE OF CONTENTS

CABINET INFRARED HEATER

Installation & Operation Manual for WarmlyYours Towel Warmers

SCD. SMALL CYLINDER DRYER with Touchscreen Controller INSTRUCTION MANUAL MANUAL NUMBER Issued March 2015

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

Product Specifications Warning Light Control Cabinet

Access Control. Total Perimeter Protection Solutions from one Source

LMA LINE MONITOR ALERT USER S MANUAL

Model AD C AD RS-422 Distributor

UNC100 Integra Manual

Tailgate > Entry Sentry > ES5200

Installation & Operation Manual for WarmlyYours Towel Warmers

Section PERIMETER SECURITY SYSTEMS

Long Range Radio Alarm Transmitter

Safety & Installation Instructions

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

PLL Pump-Lead-Lag. Provides Pump Rotation, Auxiliary Pump Activation, and Pump Failure Alarm Control. Installation and Operation Manual

STATUS ALARM HISTORY ALARM RESET

Model: EF34. Owner's Guide & Installation Manual

Instruction Manual WARNING

Controllers. Instruction Manual WARNING

Inline Heater for Solvent or Gas. Installation and Operation Manual

TTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required.

HOUSING DEVICES, INC.

Protégé Eclipse LED Keypad User Manual PRT-KLES

AUTOMATION. Operator s Manual RST Series Web Enabled Input Module. Rev. A2, 1/12

Touchpad Exit Controller User Guide

Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL.

Model: 1001T/LCD-A INSTALLATION AND OPERATING INSTRUCTIONS

User s Manual and Warranty Information for Counterweighted Chain Drive ThyssenKrupp Access

Networked Access Control Panel. Installation Guide

Mark 25 Ultrapure Water Conductivity Analyzer

Voice Module Installation Guide. For use with ProSYS 16, ProSYS 40, ProSYS 128

Custom Control Systems Inc. Ellis Dryer Control Configuration and Operation Manual

ACCURATE ELECTRONICS INC PO BOX SW HALL BLVD BEAVERTON OR USA FAX

SUNCOURT INSTALLATION INSTRUCTIONS RADON FAN MODEL: RDKO4, RDK04-3, RDN04 & RDN04-3

AUTOMATIC SWINGING DOOR

Full Height Security Turnstiles

Outline Specification: EDSUKMT1 MAN TRAP CYLI NDER GATE

Alarm Tone Generator Model AG17

1500W STOVE HEATER INSTRUCTION MANUAL. Item No: 050-HA-50090

TMC Temperature Monitoring Control Temperature Range -30 to 250 F (-35 to 120 C)

Notice... 1 Trademarks... 1 US Patent Numbers... 1 Technical Services Contact Information... 2 Document Conventions... 2 Warranty...

INSTRUCTIONS FOR OPERATION AND CARE OF

NDC-F16. Access Control Panel. Installation Manual

Remote Sensor Module: EB-RSM-01

2-Port alarmcharge Hub - Manual

GAS MONITOR Model Model

OPERATION AND INSTALLATION MANUAL

Instruction Manual. Carmel Apple-Dip Warmer

In N/C the SpeedStile provides a closed walkway and will only open on acceptance of an authorised signal.

FW-RA-LED Remote Multiplex Annunciator Panels

SYSTEM CONTROL KIT READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION.

Why Should You Invest In An Access Management System?

Installation Manual COPYRIGHT NOTICE

636 and 646 Keypads. User s Manual

RMS/RPX Reader. User Manual

Effective Human Detection and Tracking Security Using Machine Vision

The Icon Series. User Guide. CDV25 Version 1.0. Iconopm1.pm

OPERATING MANUAL. The Guardian Hand Held Security Metal Detector

3800 North Mill Road Vineland, NJ USA Tel: Fax: Web: Rev. A

Underwood Heater Installation Manual

Product Specifications Warning Light Control Cabinet

Instruction Manual for the Globe Electric Countertop Griddles Model GEG16, GEG24, GEG36 & GEG48

Hardwired Model Shown. Installation & Operation Manual for WarmlyYours Infinity Towel Warmers

Owner s Manual.

THL2. Temperature/Humidity USB Datalogger INSTRUCTION MANUAL

Type 750HT Flux Rebaking Ovens

Noran Tel. FUSE PANEL Technical Practice N NCY 2/2 KLM and 4/4 GMT NEBS Level 3 Certified

Figure 1. These Installation Instructions -1- K4866 4/00 OmniProx Reader Model Series OP-10/20/30/40

3820, 3820i, 4820, 4820i

Transcription:

model The Supervisor 2000-SM is our thinnest barrier-free turnstile. Its compact form is well suited for applications where space is at a premium. COMMON APPLICATIONS Employee and Visitor Access Control Time & Attendance Integration People Counting TYPICAL INSTALLATION SITES Government Facilities Corporate Lobbies Entertainment Venues For more information or to order, call 909.591.8431 or visit us online at www.alvaradomfg.com 1

FUNCTION The Supervisor 2000-SM is a barrier-free, optical turnstile that provides bi-directional access control and other passage modes (described below). In access control mode, upon receipt of a valid card signal from an access control system, or GateKeeper turnstile control software (see Options), the integrated sensors allow a single user to pass through the turnstile in the requested direction. If an unauthorized user attempts to tailgate on the entry, the unit will recognize the illegal passage, a violation alarm will sound and red notification lights will flash. The utilizes integrated optical sensors to control access. The optical sensors detect patrons, determine the direction of patron movement and (in conjunction with the facility access system) detect unauthorized users as well as piggybacking or tailgating on allowed entries. While access control throughput will depend on the access control system and readers used, the supports extremely rapid entry and throughput. It will stack valid scans and process patrons as fast as they can walk through the turnstile. AVAILABLE CONFIGURATIONS The consists of a pair of end cabinets that create a single lane with a 28-36 wide passageway. Center cabinets (that are the same dimensions as end cabinets) may be added to create multi-lane configurations; i.e. two end cabinets and two center cabinets create three lanes. AVAILABLE FINISHES STAINLESS STEEL External cabinet materials are fabricated from #304 stainless steel polished to a #4 satin finish. See Options for details on powder coating or cabinet construction using alternate materials. MATERIALS CABINET The cabinet is fabricated from formed and welded #304 stainless steel. See Options for details on cabinet construction using alternate materials. The cabinet base is fabricated from formed and welded carbon steel and powder coated black. INTERNAL FRAME A powder coated steel internal frame houses electronics, motors and other internal components. CABINET LIDS Cabinet lids are fabricated from 14-gauge aluminum in a clear anodized #4 satin finish. 2

OPERATIONAL MODES & FUNCTIONALITY PASSAGE MODES The offers the following user-configurable passage modes: Controlled Passage - Upon receipt of an authorization signal from an access control system, a single passage in the authorized direction is allowed. Controlled Passage can be either single direction or bi-directional. Free Passage - An authorization signal is not required for a user to pass through the lane. Free Passage can be either single direction or bi-directional. No Passage (Lane Closed) - No passage is allowed. Valid electronic credentials are ignored. Any passage will set off violation alarms. No Passage can be either single direction or bi-directional. STATUS LED DISPLAY* An illuminated status LED array is flush mounted within the cabinet lid. It is configured to function in the following manner: Yellow LED - An illuminated yellow LED means the turnstile is ready for card presentation. Green LED - An illuminated green LED indicates passage is allowed in the direction indicated and/or valid credentials have been presented. Red LED - An illuminated red LED indicates passage is prohibited in the direction indicated and/or invalid credentials have been presented. Green LED Flashing - A flashing green LED indicates the turnstile is in free passage mode in the direction indicated. AUDIBLE ALERTS & VIOLATION ALARMS The features audible alerts for the following conditions: Unauthorized Passage Blocked Sensor Tailgating/Piggybacking TAILGATE SENSITIVITY Tailgate sensitivity can be adjusted via dip switches or with GateKeeper turnstile control software (see Options). EMERGENCY OVERRIDE / FIRE ALARM Activation in conjunction with a fire alarm or other life safety system is achieved by supplying a sustained dry contact to the. During emergencies the will not emit alarm signals and status LEDs will turn off. *Photos depicting Status LEDs may be found at www.alvaradomfg.com 3

INTERFACE INTERFACE TO TURNSTILE There are three types of interfaces available for the : DRY CONTACT - Single passage activation for either direction of operation is achieved by supplying an isolated, voltage free, momentary dry contact. The length of contact is user definable through the turnstile control software. The type of input (open or closed) is also definable. RS485 - Many turnstile settings, including passage activation, can be controlled and monitored using optional GateKeeper turnstile control software. Refer to the GateKeeper specification for additional information. CUSTOM - Custom methods of integration with the facility access system can be provided. Contact Alvarado to discuss requirements. INPUTS & OUTPUTS The has a number of available inputs and outputs. The length and type of input/output (normally open or normally closed) is user definable. Terminal strip connections are provided for the following signals: Input Signal # of Terminals Direction Closed 2 Direction Open 2 Override Passage 2 Passage Allowed 4 Passage Denied 2 Alarm Reset 1 Emergency Override 1 Output Signal # of Terminals Authorized Passage 2 Unauthorized Passage 2 Violation Alarm 2 Aborted Entry (Time Out) 2 Blocked Sensor 2 Total Passage Counter 2 OPTIONS ALTERNATE CABINET MATERIALS Cabinets may be fabricated from wood, laminates or other materials. Contact Alvarado to discuss requirements. POWDER COATED CABINETS External cabinet materials may be powder coated in a variety of colors. LANE KEY CONTROLS A pair of 3-position key switches are provided to control each direction of travel per lane. Turning the key to one of three positions overrides all settings and can place the turnstile in Controlled Passage Mode, Free Passage Mode or No Passage Mode. Setting is user-configurable for each direction of travel. AUTHORIZATION CHIME A chime indicates that an activation signal has been provided to the turnstile and the user is allowed passage. BASEPLATE A baseplate for either single or multi-lane configuration is available. The baseplate is treated with a non-slip coating in the passageway area. 4

GATEKEEPER TURNSTILE CONTROL AND MONITORING SOFTWARE GateKeeper is a PC-based application that allows installed turnstiles to be monitored and administrated from a single PC. GateKeeper software allows users to configure and control multiple s or a combination of s and other Alvarado optical turnstiles. Please contact Alvarado s Customer Service Department about requirements involving the and other Alvarado turnstiles. The program runs on Windows XP, Vista and Windows 7 operating systems and communicates with units via an RS485 serial interface. ALTERNATE POWER SUPPLY & 240 VAC ON/OFF SWITCH A 110/240 VAC, 50/60 Hz power supply and appropriately rated key switch are utilized. CONDUIT REQUIREMENTS PRIMARY POWER CONDUIT 1 power conduit for primary power must be run to each master controller cabinet. Note: The product standard is 110 VAC (see Options for alternate power supply availability). LOW-VOLTAGE & COMMUNICATION CONDUIT 2 conduit must be run to interconnect the cabinet sets that form each passage lane. 20 cables to interconnect cabinets are provided to control lane operation and functionality. Conduit that interconnects a cabinet set should generally not exceed 10 in length. EXTERNAL DATA CONDUIT Alvarado recommends a 1 conduit for external data sources (i.e. access control systems). Alvarado does not provide cables for access control systems. Consult with access control system provider for power and communication conduit specifications for integrating card readers or other access control devices with turnstiles. GATEKEEPER Optional GateKeeper software is Windows based and communicates with the via RS485. Four wire communication cable must be daisy-chained from the COM port on the host computer to each turnstile to provide communication. No more than 16 turnstiles may be daisy-chained to each COM port. Total cable length from the COM port to the last turnstile in the daisy-chain may not exceed 3,000 feet (914m). RS485 communication cable must not be run in the same conduit as AC Power. 5

SHIPPING & SITE PREPARATION SHIPPING cabinets are shipped fully assembled for easy installation. Each cabinet includes mounting hardware (anchors, bolts, washers, etc.) to mount the unit to a standard, level concrete floor. SITE PREPARATION Turnstiles must be installed on a firm foundation in a manner that allows the required power and access control cabling to be pulled into the turnstile cabinet. The recommended slab platform should be a minimum of 4 deep, level concrete. Installation should be performed by a skilled installer following Alvarado s instructions. Detailed drawings and installation manuals are available online. TECHNICAL DIMENSIONS TopView 17 (432) Note: Oval area shown houses display LED s. 4 (102) Front View 39 (991) 28 or 36 (711 or 914) Dimensions shown in inches (mm). 6

THROUGHPUT RATES CARD READER TYPE* PROXIMITY MAGNETIC SWIPE MAGNETIC SWIPE WITH NUMERIC KEYPAD OMNI-DIRECTIONAL BARCODE SCANNER *Access control system response is assumed to be instantaneous ELECTRICAL POWER SUPPLY POWER REQUIREMENTS OPERATIONAL VOLTAGE WARRANTY DESCRIPTION 120VAC, 60 Hz. Maximum power consumption is 60W per lane with all options installed. Primary power is stepped down and rectified for low voltage 12 VDC, and 5 VDC operation. ON/OFF KEY SWITCH An on/off key switch is located on each master cabinet. WEIGHT, DIMENSIONS, ENVIRONMENT STANDARD METRIC PRODUCT WEIGHT* 50 lbs. 23 kg SHIPPING WEIGHT** HEIGHT WIDTH DEPTH OPERATING TEMP. RANGE 100 lbs. 39 4 17 32 to 104 F For a period of 18 months from the date of purchase, Alvarado will replace or repair, at Alvarado s option, any products or parts which are defective in materials or workmanship, provided recommended installation and maintenance procedures are followed. This warranty is void if damage is due to improper installation, maintenance or use. This warranty is limited to parts only, and does not cover labor or shipping charges incurred in connection with the removal or replacement of warranted products or parts. 45 kg 991mm 102mm 432mm 0 to 40 C STORAGE TEMP. RANGE 0 to 104 F -4 to 40 C RH 5-90% (non condensing) -- USERS PER MINUTE** *Per cabinet weight **Includes weight of shipping crate(s) This warranty is expressly made in lieu of any and all other warranties, expressed or implied, including, but not limited to implied warranties of merchantability and fitness for a particular purpose. Alvarado shall not be liable for any loss or damage, directly or indirectly, arising from the use of purchased products. In no event shall Alvarado be liable to buyer for consequential damages, special damages, incidental damages, loss of use, business interruption, loss of profits, or damages of any kind arising out of the use or inability to use a purchased product. In no event shall Alvarado be liable for damages which exceed the purchase price of a covered product. 40 25 20 40 **Approximate. Rates may increase with user familiarity. 7