White Paper Fiber optic connections: check and clean first, then connect!

Similar documents
The True Value of Connector Inspection: New Challenges and Best Practices

Best Practice Briefing

White Paper: Fiber Contamination, Cleaning and Inspection. Introduction.

MOST EFFECTIVE METHOD FOR WIPING A FIBRE

White Paper: Standard-Compliant Certification & Best Practices Ensure Fiber End-face Cleanliness to Eliminate the #1 Cause of Fiber Failure

RLH Industries, Inc. Cleaning and Testing Fiber Optic Cable. Reference Guide MD A 0507

INTERNATIONAL STANDARD

This is a preview - click here to buy the full publication

Fibre Optic Connector and Component Standards Developments & Key Issues in IEC & CENELEC. Philip C Longhurst Corporate Fibre Optic R & D Manager

AS/NZS ISO/IEC :2012

Accelerating NBN fiber testing. Tom Ronan Marketing Lead Fiber Optics Melbourne

A Quick Start Guide to Fiber-to-the-Antenna (FTTA) Installation and Maintenance Testing. Vol. 2 Tier 2 Certification

Ensuring Cabling Performance in the Customer-Owned Outside Plant

Ensuring Cabling Performance in the Customer-Owned Outside Plant. Keith Foord Product Manager Greenlee Communications

Connector Maintenance

Reflectance, The Hidden Danger That Increases Bit Error Rates in Your Fiber Networks Denver, May 22nd, 2010

A Quick Start Guide to Fiber-to-theAntenna (FTTA) Installation and Maintenance Testing. Vol. 2 Tier 2 Certification

Sources of End Face Contamination on Fiber Optical Interconnects and Recommended Best Practices for Removing the Contaminates

Multi fiber connector: Visual inspection and cleaning guide

Figure 1 - Parts of a Fiber Optic Connector

Applications Engineering Notes

2.5mm CLEANCLICKER 750 Fiber Optic Cleaner Performance Verification Report OptiTap-Style Connectors

Fibre Specification Standards

Applications Engineering Notes

OWL. Laser OWL Series. Operations Guide. Singlemode Light Sources. Optical Wavelength Laboratories. Date: October 1, 2015

Connections You Can Count On.

Cleaning of fiber optic connectors

Wilcom. Model FR2 Fiber Ranger Optical Fault Locator OPERATING INSTRUCTIONS

INTERNATIONAL STANDARD

INTERNATIONAL TELECOMMUNICATION UNION SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT

Keysight Cleaning Procedures for Lightwave Test and Measurement Equipment

VTI Services Technical Bulletin (TB) OTDR Measurement of Installed Optical Fibre Cabling Permanent Links and Links

INDUSTRY STATS SNAPSHOT

SECTION TESTING OF FIBER OPTIC CABLES

INTERNATIONAL STANDARD

Development of a dry fabric cleaner for miniature parallel optical interface PRIZM LightTurn connector

Field Test Procedure for Optical Fibre Link Measurements

INTERNATIONAL STANDARD

Fiber Optic Connector Cleaning and Inspection Kit Instructions

Fiber Optic Connector Cleaning Solutions

GR-326-CORE Singlemode Optical Connectors and Jumper Assemblies


Cleaning Instructions for Symbol IP54 Devices

HIGH POWER FIBER OPTIC PATCHCORDS

STANDARD CONFORMANCE

The Rise of Tier 2 Testing

Ensuring the Health of Tomorrow s Fiber LANs Part II OTDR Trace Analysis Become an Expert Troubleshooter with Advanced OTDR Trace Analysis

ITU-T L.404. Field mountable single-mode optical fibre connectors

Contents. Introduction... A Note About Heatsinks... Precautions...

EOTec 2000 ControlNet Fiber Optic SHR/DSHR Communications Modules* With Support for Single and Dual Channel Self-Healing Rings

INTERNATIONAL STANDARD

Advancing Fiber Optic Connectivity

WHITE PAPER FIBER OPTIC SENSING. Summary. Index. Introduction. About Fischer Connectors

Keysight 81663A DFB Laser Source Module

The Optical Time Domain Reflectometry and the Fusion Splicer Laboratory exercise

HELKAMA. Optical Fibre Cables

FTTH NETWORK TESTING: REAL APPLICATIONS USING THE OLTS METHOD

The Importance of Properly Cleaning Fiber During Splicing

Socket Heat Fusion Techniques. A Guide for Instruction and Training in Vanguard Socket Heat Fusion

Draft ES V1.1.1 ( )

ISO Acceptance tests for Nd:YAG laser beam welding machines Machines with optical fibre delivery Laser assembly

Fibre (TIA) Field Test Specification

INTERNATIONAL STANDARD

MicrOTDR. Optical Fault Locator. User Manual

Fiber Optic Patch Cord and Pigtails

FIA-TSD OPTICAL FIBRE - DISPOSAL OF WASTE

INTERNATIONAL STANDARD

Cleaning a Fibre Optic Solution

Static Eliminators. Overhead Ionizing Blower Model IN5130. Instruction Manual

Titel (auf Masterfolie editierbar) Cleaning of Fiber Connectors

USERS MANUAL EasySplicer

User Guide. T-25S-L (Coating Clamp) T-25U-L (Coating Clamp)

SELF-ADHESIVE FILM INSTALLATION GUIDE

Basic Professional Fiber Optic Installation

INTERNATIONAL STANDARD

Simply perfect garden watering. With these step-by-step instructions, you can quickly and easily plan your customised Kärcher Rain System.

UNSIGNED HARDCOPY NOT CONTROLLED

4120 Fire Alarm Network Reference

EXECUTING HIGHLY ACCURATE FIBER MEASUREMENTS IN A FRACTION OF THE TIME

RaySense. Fiber Optic Distributed Vibration Sensing (DVS) for Pipeline Security and Leak Detection

USERS MANUAL EasySplicer

Following this guideline enables proper treatment of the relays during the critical phase in the relay life.

HW-17 Record Cleaning Machine Setup and Instruction Manual

OF-500 OptiFiber. Advanced Test Equipment Rentals ATEC (2832) Users Manual. Certifying OTDR

RaySense. Fiber Optic Distributed Acoustic Sensing for Pipeline Security and Leak Detection

SERVICING INFORMATION

MANUAL Oil Level Sensor

Requests for Daily Care and Maintenance

INTERNATIONAL STANDARD

THROUGH-WALL AIR-TO-AIR HEAT PUMP AND AIR CONDITIONER. Instruction Manual. Model AMB-12H

H-16.5 Record Cleaning Machine Setup and Instruction Manual

Special Provision No. 683S28 December 2017

Data sheet OpDAT breakout cable 12x1 OM4 - bend insensitive, class Dca s1 d1 a1

M700-Series Multifunction OTDR

3M Crimplok + Connector 8700-UPC & APC SM SC 900 µm

Decon Scrubber Owner s Manual

Routine Cleaning of the icolor 700 Continuous Digital Label Press

Paper 1-IS-35 / A NEW UV SENSOR METHOD FOR SEWER RENOVATION Page 1

Agilent 81662A and 81663A DFB Laser Source Modules User s Guide

FagronLab NP-1 UV. Negative pressure workbench. User Manual

Transcription:

White Paper Fiber optic connections: check and clean first, then connect! How installers ensure the quality of their work

Fiber optic connections: check and clean first, then connect! How installers ensure the quality of their work CONTENTS 1. When to clean?... 3 2. Checking surfaces... 4 Scratches through zone B... 5 Scratches through zone A... 5 Alcohol... 5 Grease... 6 Oil... 6 Dirt particles... 6 Water... 7 Water (after plugging in once)... 7 PASS... 7 3. How to clean?... 8 4. Standards and dependencies... 9 4.1. IEC 62627-01/TR... 9 4.2. Surface geometry... 9 4.3. Return loss... 10 4.4. Insertion loss... 10 5. Additional information... 10 Copyright 2016 Reichle & De-Massari AG (R&M). All rights reserved. It is not permitted to pass on and replicate this publication or parts of it for whatever reason and in whatever form without express written permission from Reichle & De Massari AG. Information contained in this publication may be altered without prior notice. This document was produced with the greatest possible care; it presents the state of the art at the time of preparation. White Paper Cleaning fiber optic connections v1 en Daniel Eigenmann 2

Only a clean connector delivers full performance With the latest advances in optical high-performance networks, connectors are becoming ever more crucial components in the passive fiber optic infrastructure. High-quality connectors ensure optimum transmission rates and constant network availability in all areas, from WAN to metropolitan area and campus networks, as well as backbone networks and subscriber connections. However, only clean connections achieve the values guaranteed by standards and manufacturers. It is therefore vital that installers possess sound knowledge of the correct way to install and clean these components. This white paper contains information on the currently applicable standards and discusses the relevance of properly cleaned fiber optic connectors. Application: Technology: Format: Subjects: Objective: Target group: Fiber optic cabling Fiber optic connectors White Paper Cleaning optical connectors when and how? Provide information on surface properties and set out a practical approach. Ensure the quality of installations. Installers, network managers, users of fiber optic cabling Author: Daniel Eigenmann Published: September 2016 1. When to clean? The performance of a fiber optic system depends heavily on how clean the interfaces are. Small particles of dirt, grease, dust etc. can negatively impact transmission characteristics and even destroy a fiber optic connection depending on the circumstances. The perpetual increase of data rates in particular is making transmission quality more sensitive to dirty connections. This is why it is becoming increasingly important to test all connectors and adapters, and, if necessary, to clean them before they are mated. In this case, both sides of a connection including the guide sleeve should be cleaned, as recommended in IEC 62627-01/TR for example. This applies to devices and test cables, as well as for network components. New connectors should also be tested and, if necessary, cleaned. This is the best guarantee for a reliable optical network. In fact, various studies have shown that up to 85% of local faults are caused by connectors that either have not been cleaned carefully or have not been cleaned at all. White Paper Cleaning fiber optic connections v1 en Daniel Eigenmann 3

However, it is a popular misconception that every connector should always be cleaned before being plugged in. Most connectors actually arrive at their place of deployment in the pristine state in which they left the production facility. In such cases, the installer can actually only make the quality worse by cleaning the connector. The rule should be not always clean before you plug in but in fact always check before you clean. Figure 1 shows the procedure in full. Figure 1: Procedure for checking a connector 2. Checking surfaces Although the manufacturer will conduct a test using an interferometer, it is still necessary to perform a visual inspection on site using a microscope or another suitable tool. Here, the surfaces of the fiber ends are checked for scratches, cavities, adhesive residue and dirt. In order to achieve the defined optical properties of the connector, all four zones of the end surface of the fiber (as shown in Figure 2) must be completely free of dirt. Otherwise, the following criteria apply: Zone A: No scratches or pits permitted. 25 µm is three times the core diameter. Therefore, the zone must be checked especially carefully. Zone B to C: Small scratches and cavities may be permitted. Here, too, absolutely no dirt must be present. Zone D: Although this is already the ferrule region, this zone must still be checked as it is also part of the transmission area due to the contact stress on the connector. The interferometry test also registers a diameter of 250 µm. Figure 2: Surface zones on the end of the fiber (SM) The detailed pass/fail criteria are standardized in IEC 61300-3-35. However, the primary focus of this white paper is the topic of cleaning. A minimum 200-fold enlargement is required for the visual surface test. Use a lower resolution for a simple dirt check in the field. However, at least 100-fold enlargement is recommended here too. White Paper Cleaning fiber optic connections v1 en Daniel Eigenmann 4

Scratches through zone B Manufacturing defect A dirt particle on the cleaning device has scratched the ferrules As the scratches are clearly < 3µm, the connector can be used (IEC 61300-3-35) If the problem reoccurs, use a new cleaning cloth Scratches through zone A Figure 3 Manufacturing defect A dirt particle on the cleaning device has scratched the ferrules Replace the connector (IEC 61300-3-35) or regrind it if possible Alcohol Figure4 Connector was cleaned but too much alcohol was used or the connector was not wiped on a dry cloth It is also possible that there is alcohol in the adapter (or microscope!) or on the opposing connector Clean the endface of the connector If necessary, clean the adapter/microscope Figure5 White Paper Cleaning fiber optic connections v1 en Daniel Eigenmann 5

Grease Connector endface has come into contact with skin Dirty dust caps Dirty microscope Clean the connector endface AND the ferrule mantle If the connector is not plugged in immediately, use new dust caps Clean the microscope if necessary Oil Figure 6 Unsuitable cleaning agent Dirty dust caps Dirty microscope Clean the connector endface AND the ferrule mantle If the connector is not plugged in immediately, use new dust caps Clean the microscope if necessary Dirt particles Figure7 Connector has no dust cap Dirty dust caps Dirty microscope Clean the connector endface AND the ferrule mantle If the connector is not plugged in immediately, use new dust caps Figure8 White Paper Cleaning fiber optic connections v1 en Daniel Eigenmann 6

Water Unsuitable cleaning agent Dirty dust caps Dirty microscope Clean the connector endface AND the ferrule cladding If the connector is not plugged in immediately, use new dust caps Water (after plugging in once) Figure9 Dirty connector plugged in Dirty adapter Dirty mating connector Clean the connector endface and ferrule mantle on both connectors and the adapter PASS Figure10 Figure11 White Paper Cleaning fiber optic connections v1 en Daniel Eigenmann 7

3. How to clean? The following tools are recommended for cleaning: lint-free cloths isopropyl alcohol lint-free cotton buds dry cleaning tape Instructions: - Wet a lint-free cloth with a few drops of isopropyl alcohol. - Clean the ferrule cladding with the wet part of the cloth. The first 3 to 5 mm are the most important here, as this part is fed into the guide sleeve depending on the connector type. - Lay the cloth out on a table or flat surface. The surface should not be too hard. Several cloths placed on top of one another can be used here. This makes a small cushion. - Pull the connector in a straight line across the wet part of the cloth. Do this very gently. Pull the connector from the wet part of the cloth over to the dry part. The alcohol dissolves dirt and oil residues and is removed when the connector is pulled across the dry part of the cloth. Various cleaning devices are available on the market. With most of these, the connector does not move across the cloth, but instead the cloth moves under the connector. However, in principle, the procedure is the same as described above. White Paper Cleaning fiber optic connections v1 en Daniel Eigenmann 8

4. Standards and dependencies 4.1. IEC 62627-01/TR The procedure for inspecting and cleaning optical connections is described precisely in Annex B of IEC 62627-01/TR/Ed2 Fibre optic interconnecting devices and passive components Technical Report Fibre optic connector cleaning methods. This technical report stresses how important it is to use the correct procedure. It states that: With increased data rates, it has become increasingly important to ensure that all plugs and adaptors are inspected and if necessary cleaned before mating. This means that both sides of a connection and the inside of adaptor sleeve should be inspected and if necessary cleaned before making the connection. This applies to test equipment and test cords as well as network components. New plugs shall be inspected and if necessary cleaned. Inspecting and cleaning every connection every time is the best assurance of a reliable optical network. In short, never connect without first inspecting and cleaning if necessary. And this must happen on site. Although providers of optical components and systems such as R&M guarantee that their products leave their premises in perfect condition, they have no influence over the human and environmental factors that arise during transport and storage. Therefore, in order to guarantee the performance of an optical network, all connections must be checked including the test cables, the outer patch cords and, above all, the permanent connections inside the patch panels and cabinets. IEC 62627-01/TR comprehensively describes the cleaning methods for fiber endfaces. Furthermore, all suppliers of optical components and systems provide cleaning instructions for their products that are specifically tailored to the material properties, design features etc. The instructions from R&M, which are delivered with every product, reflect the recommendations of IEC 62627-01/TR so that all installers can apply these methods. They also comply with the inspection criteria of IEC 61300-3-35 Interconnecting devices and passive components Basic test and measurement procedures Examinations and measurements Visual inspection of fiber optic connectors and fiber-stub transceivers. The criteria of IEC 61300-3-35 can be used to make clear decisions on whether the condition of a connector is good or bad. Users can avoid faults in the optical network, signal problems, excessive insertion loss, poor return loss or even permanent fiber damage simply by following R&M s instructions. 4.2. Surface geometry The surface quality of the fiber end plays a crucial role in determining the transmission properties and service life of a connector. Dirt can and will permanently damage the surface and often causes changes in the connector geometry. If one considers that connectors in the region of 250 µm are elastically deformed by the contact stress (see also Hertzian contact stress), it is clear that a dirt particle will generate enormous forces at specific points and is capable of permanently damaging the optical fiber and/or the bonding gap. White Paper Cleaning fiber optic connections v1 en Daniel Eigenmann 9

4.3. Return loss Dirt, along with damage such as scratches and cavities, is one of the main causes of problems with the return loss. Dirt causes - a change in the refractive index - a pathway to the air - and thus backscattering of the modes or photons. Any kind of impurity leads to significant impairment of the return loss 4.4. Insertion loss The effects of dirt on the insertion loss are slightly less serious. Water residue, dust or other residues are typically pushed to the outside by the convex shape of the connector endface. It is therefore unlikely that larger particles will remain in the core area. At the edges, they can only deflect a small portion of the light. Even slightly deflected modes can still be coupled into the next fiber. Dirty surfaces have an impact on the insertion loss, but there needs to be a high level of contamination before measurable changes in the loss can occur. 5. Additional information In addition to this white paper, we recommend: - White paper Modal noise in fiber links - White paper Manufacturer-Neutral Quality Grades for Fibre-Optic Connectors Download from www.rdm.com You will also find further information about R&M s products and solutions here. White Paper Cleaning fiber optic connections v1 en Daniel Eigenmann 10