Silicon Pyranometer GSM xx

Similar documents
Silicon UVAB Sensor E xxx

Wind Alarm Instrument

Wind Alarm Instrument x.x0x

Aspirations-Psychrometer Assmann Model / 000

Flame detector. The QRA4.U is for use with the following types of burner control:

Flame detector. The QRA4.U is for use with the following types of burner control:

for relative humidity and temperature with calibration certificates

16S-Series 150W. In Vivo SPF Sunscreen Testing Solar Simulator

Laser Distance Sensor Type M Analog-Output

UV measurements for medical applications using SiC photodiodes

CMT MANUAL 6. NMC SENSORS

Flame detector. Building Technologies Division Infrastructure & Cities Sector

optris Outdoor protective housing

Dry Block Heater Operating Manual

SWARCO TRAFFIC SYSTEMS GMBH. TDD1-MW Traffic Detector User Manual TDD1-MW_BE_00

Room Temperature Sensors

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

Installation and operation manual DPC200 - DIFFERENTIAL PRESSURE CONTROLLER. Low pressure with PI-control-mode

UV Flame Supervision System

Digital Sensors Erythema Sensor PMA2101

Ex SOLENOID / ALARM DRIVER. PRepower 5203B. Table of contents. Applications Safety instructions Technical characteristics...

sglux UV-SENSOR PROBES Catalogue

QRA4.U. Flame Detector. Siemens Building Technologies HVAC Products

Operating Instructions!

1. Index. 1. Index 1 2. Important User Information Contact Information 2

Gas cylinder scale Model GCS-1

FEBL8511_REFBOARD_Manual-01 ML FC. REFERENCE BOARD Manual for UV Sensor (QFN)

Room Sensors. Building Technologies HVAC Products ... Symaro. for relative humidity (high accuracy) and temperature

Model 3300 Technical Support and Installation Manual

Infrared Single Light Barrier. Mounting Instructions DO560

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

PM100V PM80V PM15V. Ex works. Depending on the specific range of application a regular ecalibration of the sensor head (PMU-V) has to be effected.

TDS 20 R / TDS 30 R / TDS 50 R

Flameproof Manual Call Points

Dry Bath Heating Systems

safety & regulatory information

Duct Sensors. Siemens Building Technologies HVAC Products. Symaro. for relative humitidy (high accuracy) and temperature

optris TM Temperature Monitor for Infrared Sensors Operators manual

COMPACT FLAME CONTROLLER CFC 1000

Benefit from our experience and competence Application-focused solutions from UV to IR

HANDBUCH / MANUAL / MANUEL / MANUALE TopScan-S

QAF63.2 QAF63.6. Frost sensors for use on the air side. Building Technologies HVAC Products

Safety. Operating instructions UV sensor UVS 10 DANGER WARNING. Contents CAUTION Edition Please read and keep in a safe place

Regulated Ex-Heater HEX with internal controller, HEX with external controller II 3 G II 3 D

Flame Monitor for Multiple Burner Furnaces D-LE 603 D-UG 660

RS Pro Infrared Temperature Sensor

Instruction manual SPU II Hard alarm output contacts

Aquamax KF Oil Evaporator. User Manual

Control and Indicating Equipment

Four channel video link For low cost video transmission

A T L A S - SolarClimatic Test Cabinet SC 2000 MHG

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

Duct Temperature Sensors

UV Weather Resistance Test Chamber Technical Data

QRA10... QRA53... QRA55...

1. Index. 1. Index 1 2. Important User Information Contact Information 2

(1135/2016) Translation from Finnish Legally binding only in Finnish and Swedish Ministry of Economic Affairs and Employment, Finland

QFM21... Siemens Building Technologies HVAC Products. Symaro Duct Sensors. for relative humidity and temperature

QFM21... Duct sensors. Symaro. for relative humidity and temperature

Technical Information OUSAF44

SEC Signature Process Gas Analyzer

SIMRAD GD10L - IR GAS DETECTOR OPERATING MANUAL

RED1. Technical Support And Installation Manual. Models ST, E1, E2, E3, E4, and 420. Approved

AZSG10000/AZSG10005/AZSG10010 ABUS Wired Outdoor Siren

Operating Instructions

FTA-1 Aspirator with trap flask

ACTIV8 ONE OFF. 1 Tips USER S GUIDE COMBINED RADAR OPENING AND ACTIVE INFRARED SAFETY SENSOR. 1 Description. 2 Symbols.

Operational Instructions. Glue Applicator MS Translation from German to English

COMPACT FLAME CONTROLLER CFC 100

SCHMIDT Flow Sensor SS Ex - Supplementary instructions for use in explosive atmospheres ATEX

QFM41.. Duct sensors QFM41.. AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

Instructions for the fan motor control system, SILVER C

CHILLGARD M-100. Refrigerant Sensor. Operating Manual. Order No.: /02

Laser Safety Products. Edition 20

QRA2... QRA10... QRA53... QRA55... Flame Detectors. Siemens Building Technologies HVAC Products

2 Ensure that all personnel in the area are wearing the appropriate protective eyewear.

INSTALLATION GUIDE. AXIS A1001 Network Door Controller

Throughbeam photoelectric sensor for the detection of aqueous liquids. Dimensioned drawing

COMPACT FLAME CONTROLLER CFC 2000

TTK 70 S OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK70S-TC-001-EN

Operating instructions

PUV, PIR and PFO Series BROCHURE

TTK 75 E OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK75E-TC-002-EN

Architectural and Engineering Specification for a Fence-Mounted Perimeter Intrusion Detection System. FlexZone

QRA10... QRA53... QRA55...

(Publication of titles and references of harmonised standards under Union harmonisation legislation) (Text with EEA relevance) (2015/C 226/03)

IRIS IP65 IRIS UNISCAN APPLICATION MANUAL

MANUAL Oil Level Sensor

INTERNATIONAL STANDARD

For the user / for the installer. Instructions for Use and Installation. time SWITCH hour time clock

COMPACT FLAME CONTROLLER CFC 200 (Formerly 8.XX)

COMBY 4000 & 9000 STEAM CLEANER OPERATOR MANUAL

EC-Declaration of Conformity

GE Healthcare. Mixer M-925. Instructions

Operating Instructions

GigaCore 12. Gigabit Ethernet Switch for the entertainment industry. Quick Start Guide. V2.1.0 Rev5. English

(Publication of titles and references of harmonised standards under Union harmonisation legislation) (Text with EEA relevance) (2017/C 389/04)

Procedure for the Approval of New Fire Detection and Alarm Technologies

OFFICIAL JOURNAL OF IN VITRO DIAGNOSTIC MEDICAL DEVICES DIRECTIVE (98/79/EC)

Equipment specifications (D6)

Transcription:

THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA Instruction for Use 021045/11/09 Silicon Pyranometer GSM 3.3 7.1415.09.0xx ADOLF THIES GmbH & Co. KG Hauptstraße 76 37083 Göttingen Germany Box 3536 + 3541 37025 Göttingen Phone ++551 79001-0 Fax ++551 79001-65 www.thiesclima.com info@thiesclima.com

Safety Instructions Before operating with or at the device/product, read through the operating instructions. This manual contains instructions which should be followed on mounting, start-up, and operation. A non-observance might cause: - failure of important functions - Endangering of persons by electrical or mechanic effect - Damages at objects Mounting, electrical connection and wiring of the device/product must be carried out only by a qualified technician who is familiar with and observes the engineering regulations, provisions and standards applicable in each case. Repairs and maintenance may only be carried out by trained staff or Adolf Thies GmbH & Co. KG. Only components and spare parts supplied and/or recommended by Adolf Thies GmbH & Co. KG should be used for repairs. Electrical devices/products must be mounted and wired only in voltage-free state. Adolf Thies GmbH & Co KG guarantees proper functioning of the device/products provided that no modifications have been made to the mechanics, electronics or software, and that the following points are observed: All information, warnings and instructions for use included in these operating instructions must be taken into account and observed as this is essential to ensure trouble-free operation and a safe condition of the measuring system / device / product. The device / product is designed for a specific application as described in these operating instructions. The device / product should be operated with the accessories and consumables supplied and/or recommended by Adolf Thies GmbH & Co KG. Recommendation: As it is possible that each measuring system / device / product under certain conditions, and in rare cases, may also output erroneous measuring values, it is recommended to use redundant systems with plausibility checks with security-relevant applications. Environment As a longstanding manufacturer of sensors Adolf Thies GmbH & Co KG is committed to the objectives of environmental protection and is therefore willing to take back all supplied products governed by the provisions of "ElektroG" (German Electrical and Electronic Equipment Act) and to perform environmentally compatible disposal and recycling. We are prepared to take back all Thies products concerned free of charge if returned to Thies by our customers carriage-paid. Make sure you retain packaging for storage or transport of products. Should packaging however no longer be required, arrange for recycling as the packaging materials are designed to be recycled. Documentation Copyright Adolf Thies GmbH & Co KG, Göttingen / Germany Although this operating instruction has been drawn up with due care, Adolf Thies GmbH & Co KG can accept no liability whatsoever for any technical and typographical errors or omissions in this document that might remain. We can accept no liability whatsoever for any losses arising from the information contained in this document. Subject to modification in terms of content. The device / product should not be passed on without the/these operating instructions. 2-10 021045/11/09

Contents 1 Models... 3 2 Application... 3 3 Construction... 4 4 Installation... 4 5 Maintenance... 4 6 Connecting Diagram... 5 7 Technical Data... 6 8 Dimension diagram... 7 9 EC-Declaration of Conformity... 8 1 Models Order - No. Measuring range Electrical output Operating voltage 7.1415.09.040 0...1300 W/m² 0 20 ma 9 24 V DC 7.1415.09.041 0...1300 W/m² 4 20 ma 9 24 V DC (2-leads-circuit) 7.1415.09.051 0...1300 W/m² 0 5 V 9 24 V DC 7.1415.09.061 0...1300 W/m² 0 10 V 14 24 V DC 2 Application Global radiation is the sum of direct solar radiation and diffuse radiation reaching the surface of the earth. The spectral range extends from the short-wave-range at 300 nm (UV-B) to the long-waverange at 5000 nm (IR). The Pyranometer detects almost 90 % of the sunlight-spectra in the range from 400 nm to 1100 nm, and thus, comprises the uv-(ultraviolet radiation), vis-(visible radiation), and the part of the ir- (Infrared-radiation) light. The measuring results give information about medical and biological cohesions, compared with other spectral ranges. The Pyranometer can be used in the fields of medical and biological research, with weather information and prognosis systems, in the climatic research, in the field of agriculture, and for the general information of the population. 3-10 021045/11/09

3 Construction The Pyranometer is a fragile electronic-optical device. The housing is made of anodized aluminium with an uv-transparent plastics dome. The instrument is protected against jets of water and rain. A small package of silica-gel serves for drying the inner housing and protects the dome against steaming-up. The results are cosine-corrected. 4 Installation The mounting shall be effected with greatest care. The Pyranometer is fixed with two screws M4 onto a suited holder, and should be exactly in horizontal position. The mounting site should be selected in a way, that the sun radiation reaches the surface of the sensor all day. The Pyranometer must have a free horizon into all directions. The instrument marking must indicate to Northern direction. Instruments without north marking shall not be aligned. North Mark For the data transmission please use the cable available. For the connector pin assignment please refer to chapter 6. When connecting the cable coupling to the Pyranometer please take care that the mounting notches of coupling and plug coincide. The cap nut is to be screwed tightly. 5 Maintenance The electronic-optical part of the Pyranometer needs no service. A check of the calibration is possible acc. to the customer s request. The dome, and the housing are to be cleaned, if necessary, with a soft and wet cloth twice a year. Please use only liquid cleaning agents without abrasive additives or solvents. The outer cleaning should be done with clear water or possibly with washing-up liquid. 4-10 021045/11/09

6 Connecting Diagram Order No. 7.1415.09.041 Order Number : 7. 1415. 09. 041 5 pol. Plug 1 2 3 4 5 Main Power see Diagram Ground R L 4... 20 m A 0-1300 W / m² RL- Function of the Main Power Diagram for Output 4-20 ma 1000 Ohm R L (Load) 500 Ohm 12V 20V 0 Ohm 30V Order No. Order- Number* 7.1415.09.040 5 pol. Plug 7.1415.09.051 7.1415.09.061 1 2 3 4 5 Ground 0-1300 W / m² Power Output 9... 24 V DC 0... 20 ma 9... 24 V DC 0... 5 V 14 24 V DC 0... 1 0 V *Order Number 7. 1415. 09. 040 7. 1415. 09. 051 7. 1415. 09. 061 5-10 021045/11/09

7 Technical Data Global measuring range 0 1300 W/m 2 Spectral range 380 1100 nm Max. spectral sensitivity 780 nm Operating temperature -20 C +60 C Output Electrical Output: 7.1415.09.040 0 20 ma 7:1415:09:041 4 20 ma 7.1415.09.051 0 5 V 7.1415.09.061 0...10V Power supply 7.1415.09.040 7:1415:09.041 7.1415.09.051 7.1415.09.061 Sensor type Diffuser material Dome Operation voltage: 9...24 V DC 9 30 V DC, 2-leads-circuit 9 24 V DC 14...24 V DC Silicon- photodiode PTFE Plastics (PMMA) Cosine correction fault f2 < ±3% Linearity < ±5% Abs. fault < ±10% Installation 2 screws M4 in the ground of housing Kind of connection Plug with 5 m cable Weight approx. 0.3 kg Protection IP67 Load: see RL- Diagram see RL- Diagram >220KOhm >220KOhm Power consumption: typ. 3 ma + I out / max. 6 ma + I out I out (4-20 ma) typ. 3 ma / max. 6 ma typ. 3 ma / max. 6 ma 1.0 Spectr. Sensitivity 0.8 rel. sensibility 0.6 0.4 0.2 0.0 400 500 600 700 800 900 1000 wavelenght in nm 6-10 021045/11/09

8 Dimension diagram 83 mm 7-10 021045/11/09

9 EC-Declaration of Conformity Document-No.: 000319 Month: 06 Year: 08 Manufacturer: A D O L F T H I E S G m b H & C o. K G Hauptstr. 76 D-37083 Göttingen Tel.: (0551) 79001-0 Fax: (0551) 79001-65 email: Info@ThiesClima.com Description of Product: Pyranometer; Silicon Pyranometer; UVAB Sensor; UVB Sensor; Silicon-Sensor PAR; Sunshine Indicator Article No. 7.1415.05.040 7.1415.05.041 7.1415.05.051 7.1415.05.061 7.1415.09.040 7.1415.09.041 7.1415.09.051 7.1415.09.061 7.1416.10.040 7.1416.10.041 7.1416.10.051 7.1416.10.061 7.1416.20.040 7.1416.20.041 7.1416.20.051 7.1416.20.061 7.1418.00.040 7.1418.00.041 7.1418.00.051 7.1418.00.061 7.1420.00.000 specified technical data in the document: 021430/12/04; 021006/07/01; 021052/11/03; 021054/05/02; 021051/01/06; 021049/05/04 The indicated products correspond to the essential requirement of the following European Directives and Regulations: 2004/108/EC 2006/95/EC DIRECTIVE 2004/108/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 15 December 2004 on the approximation of the laws of the Member States relating to electromagnetic compatibility and repealing Directive 89/336/EEC DIRECTIVE 2006/95/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 12 December 2006 on the harmonisation of the laws of Member States relating to electrical equipment designed for use within certain voltage limits 552/2004/EC Regulation (EC) No 552/2004 of the European Parliament and the Council of 10 March 2004 on the interoperability of the European Air Traffic Management network (the interoperability Regulation) The indicated products comply with the regulations of the directives. This is proved by the compliance with the following standards: Reference number IEC 61000-6-2: 2005 IEC 61000-6-3: 2006 IEC 61010-1: 2001 Specification Electromagnetic compatibility Immunity for industrial environment Electromagnetic compatibility Emission standard for residential, commercial and light industrial environments Safety requirements for electrical equipment for measurement, control and laboratory use. Part 1: General requirements Place: Göttingen Date: 26.06.2008 This declaration certificates the compliance with the mentioned directives, however does not include any warranty of characteristics. Please pay attention to the security advises of the provided instructions for use. 8-10 021045/11/09

9-10 021045/11/09

ADOLF THIES GmbH & Co. KG Hauptstraße 76 37083 Göttingen Germany P.O. Box 3536 + 3541 37025 Göttingen Phone ++551 79001-0 Fax ++551 79001-65 www.thiesclima.com info@thiesclima.com - Alterations reserved- 10-10 021045/11/09