Reyrolle Protection Devices. 7PG26 DAD High Impedance Current Relay. Answers for energy

Similar documents
7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for Infrastructure & Cities.

7XG3120 ReyArc20 Arc Fault Monitor Relay Energy Management

7XG3130 ReyArc30 Optical Arc Fault Sensor Energy Management

1S25. Arc Fault Monitor 4 Zones, 8 Sensors. Features. Introduction. ARC Fault Protection

EARTH LEAKAGE RELAY. User Manual - Issue 1.0

i-con Switchgear Condition Monitoring HV Switchgear Integrated Substation Condition Monitoring ISCM Answers for Infrastructure & Cities.

BE1-50/51B with S1 Case or FT-11 sized Case and Cover For non-retrofit applications, see Product Bulletin UHD.

Instruction Manual August sitrans CU 02

03.03.mmm REV.2 09/01

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger

Installation Guide for AL400ULM. Multi-Output Access Control Power Supply Charger

CIRCUIT BREAKER FAIL PROTECTION

PART 4 ELECTRICAL STANDARDS

REA 105 Arc Protection Module. Operator s Manual

FireNET Plus Wiring Instructions

AL800ULADA. NAC Power Extender. Installation Guide

Instruction Manual December 2001 ENACOCU02

VAMP 120 & 121. Arc flash detection units. Product picture

AL600ULADA. NAC Power Extender. Installation Guide

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

DGC-1000 DIGITAL GENSET CONTROLLER

Multi-Output Access Control Power Supply Chargers VDC or 24VDC VDC or 4 24VDC.

SEL Arc-Flash Solutions

Installation, Operating and Maintenance Manual

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option

SEL Arc-Flash Solutions

Multi-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC.

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

Motogard. Over Temperature Protection System. Installation Instructions

631RF Amp Power Supply

Numerical Relay MELPRO TM -S Series

1.7 A-ISOMETER IRDH575. RoHS. Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

Thermo Scientific Ramsey TM Series Sensing Speed Conditions on Rotating Shafts and Machinery

CU-02 with Senaco Plus

VAMP 120 & 121. Arc Flash Protection Units. Arc Protection. Customer benefits

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

Wallace & Tiernan Controllers & Analysers ChemTrim Disinfection Controller

PDD-8PCI. Power Distribution Board With Supervised Interface. Installation and Specifications Manual

Temperature Controllers

M2500 Engine Controller Installation Manual

Plug-in Base, Long Range Sensor E3B2

Current Matters. The latest News from SPDL.

DGC-500 DIGITAL GENSET CONTROLLER

1S26 User Guide. Arc Fault Monitor + Integrated Current Check Relay. Advanced Protection Devices. relay monitoring systems pty ltd.

Ordering Key. Dielectric strength

Table of Contents. Protective Relays

DE20 INSTRUCTION MANUAL

Ç Consilium Consilium US, Inc. 59 Porter Rd Littleton, MA USA

1 Description. 2 Specifications. HP600ULM Access Control Power Supply/Charger with Power Distribution Controller PN 52393:A 1/05/06 ECN

Revision: None DCN No. First Issue Date: November 30, 1998 Product: Standard DCT, 120-volts

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

Carbon Monoxide Transmitter

Ramsey Series Motion Monitoring Systems Accurate Sensing of Speed Conditions on Rotating Shafts and Machinery

Specification/ Data Sheet

7SG17-Rho 3 Multifunction Protection Relays Answers for energy

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

BSR Addressable Fire Detection control panel. Installation operation manual

Instruction Manual Model A

RE-PR3-E-27 3-Phase Panel Mount 27kW

Monitoring Devices 11/1

OPERATION AND INSTALLATION MANUAL

BT1 SINGLE ZONE FIRE ALARM SYSTEM OPERATORS MANUAL

1. Instruction. 1.5 Warranty Comar Condensatori S.p.A. guarantees its own products for twelve months from purchase

VAmP 120. Arc Flash Protection Units. Arc Protection. Customer benefits

VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER

Intelligent Security & Fire Ltd

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

INSTRUCTION MANUAL and DETAILED PRODUCT SPECIFICATION TRIPLEX PUMP CONTROL SYSTEM MODEL NUMBER CPC-3. M336 Rev F. November 21, 2000.

Modus Model DA General Eastern Low Differential Pressure Alarm Controller

Installation Guide for models:

CMD420 / CMD421 Series

Figure 30: Sample Case 8

ZIOU/230 - MAINS IO INSTRUCTION MANUAL

Dissolved Oxygen Analyzers

La Marche Manufacturing Company Option 16 Series. Digital Combined Accessory Package. Installation and Operation Manual

Alan Wells Technical and Standards Director Certsure LLP trading as NICEIC

Fire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

Residual current monitor RCM470LY/RCM475LY. for TN and TT systems (AC and pulsating DC currents)

DS9400 Series. Release Notes for Firmware V2.07. Fire Alarm Control Panel

Operation and use. Functions and characteristics

C-Bus Four Channel General Input Unit Installation Instructions

1X30 Trip Circuit Supervision Relay

PH / ORP Analyzers MODEL OPM223/253. Wedgewood Analytical Inc. Liquid Analytical Measurement & Control Specialists DESCRIPTION FEATURES APPLICATIONS

The new detector from Rafiki

BX444-Mc Gas Detector

RD3 and RCQ020 Electronic low-voltage residual current devices for miniature and moulded-case circuit-breakers

Construction Electrical

FCR 05, FCR 07. Power factor correction controller. User and service manual

LINETRAXX VME420. Multi-functional relay for overvoltage, undervoltage and frequency monitoring in AC/DC systems with external supply voltage

ECO N DATE DESCRIPTION OF CHANGE CHG

/ sicam SICAM Safety Full functionality for safety-critical applications Answers for infrastructure and cities.

Gas Safety Products. Installation, operating and maintenance. Merlin CO2 Monitor 4500PPM. Merlin CO2 Monitor. Rev: 11 Date:

elite Model ELN Centralized Emergency Lighting Inverter Systems 550 W to 1.5 KW Systems

FDMM01S - FDMM02 - FDMM10- FDMM11S FDMM12 - Input / output mini modules

isopv425 and AGH420 Ground Fault Detector for Ungrounded Solar Arrays < 100 kw And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

Connection. e. g. Pt100. reference limit. yellow Output I. Composition

AQ 100 Series. Arc Flash Protection System

Door Release Power Supply

Transcription:

Reyrolle Protection Devices 7PG26 DAD High Impedance Current Relay Answers for energy

Siemens Protection Devices Limited 2

7PG26 DAD High Impedance Circulating Current Relay Description The type DAD relay provides high-speed, high impedance, current differential protection with individual open-circuit monitoring of the CT secondary circuits. An advanced design input filter with a harmonic rejection circuit improves overall protection stability by rejecting the harmonics generated by the onset of CT saturation. The relay is provided with four output relays each with two contacts. Three of the relays, those normally associated with the alarm function, can be selected for latched/nonlatched contact operation Functional Overview High speed of operation. Input filter characteristic rejects d.c. offset transients and provides excellent harmonic rejection Integrated open circuit current transformer supervision alarm Low a.c. and d.c. burdens Application High impedance busbar zone protection and circulating current protection of auto transformers, motors and generators. Transient stability under through fault conditions is a problem with many forms of differential protection due to variations in CT magnetizing characteristics. As saturation is approached, the CT output current waveforms become increasingly distorted with a high percentage of 3rd and other higher odd harmonics. These problems can be overcome by either using biased differential protection, or more elegantly by the use of high impedance schemes. In the latter case the relay settings are calculated assuming one CT is completely saturated. Using this worst case condition the voltage and current settings for type DAD high impedance protection can be precisely calculated with known stability margins. Intermediate conditions, where a CT is only partially saturated, increases the stability margin. This approach enables schemes to be engineered using CTs with relatively low knee-point voltages. High impedance busbar protection is recommended for all switchgear applications where faults must be cleared in the shortest possible time. High impedance schemes can provide lower fault settings and a better throughfault stability than possible with most other schemes. The stability of a current balance scheme using a high impedance relay circuit depends upon the relay voltage setting being greater than the maximum voltage which can appear across the relay under a given through fault condition. Stabilizing resistors and metrosils complete the scheme. Current transformers Experience has shown that only Class.X. CTs to BS3938 meet all the basic requirements for this type of protection. For most applications it will be found that the overall size of the CT will be smaller than that required for alternative current balance protections. Technical information Ratings, In Auxiliary supply Nominal voltage Vd.c 24V to 58V 110V to 220V* 1A and 5A 50/60Hz Voltage range Vd.c 18V to 60V 88V to 280V * will also operate from 110/120Va.c (range 88V to 132Vac) Auxiliary Supply to IEC 255-11: Allowable superimposed a.c. component, maximum of 12% of rated d.c. voltage. Allowable breaks or dips (including collapse to zero from minimum voltage) in supply, up to 20ms. The DAD relay also incorporates supervision of the CT secondary circuits. This supervision is traditionally provided by a sensitive alarm relay, but this integration of protection, CT supervision and associated timers in the DAD considerably simplifies system design and secondary wiring. Zone switch out relays are recommended to switch out an affected zone. Siemens Protection Devices Limited 3

Settings Protection: 0.5% to 96% of In in steps of 0.5% i.e. In = 1A - 5mA to 960mA in steps of 5mA Alarm: or In = 5A - 25mA to 4.8A in steps of 25mA. 50Hz -10% to 40% in steps of 10% of Is 60Hz - 9.5% to 38% in steps of 9.5% of Is Where Is is the relay current setting. Time delay: 0.25s to 63.75s in steps of 0.25s. A.C. burden: Burdens expressed in Volts. 1A rating, voltage at setting = 0.120 + 0.78 x Is volts 5A rating, voltage at setting = 0.025 + 0.08 x Is volts. D.C. burden: Indication Two red LED s per phase are provided, (TRIP and ALARM). The alarm LED is illuminated when the alarm setting is exceeded, and it will reset if the input falls below the alarm setting. If the input remains above setting it is latched on completion of the set time delay. Indications are retained in memory during breaks in the auxiliary supply and re-established when the supply is restored. Latched output contacts and indications are reset from the case reset push button which also tests all the LED s. Harmonic rejection The relay will not operate on third or higher harmonics. 2nd harmonic rejection 2:1 min. 3rd harmonic rejection 50Hz 40:1min. 60Hz 20:1 min. Range 18V to 60V 88V to 280V Quiescent short term Output contacts 0.25W 5W max. 0.65W 8W max. Output relay RL1 RL2 RL3 RL4 Function Trip Alarm Alarm Alarm Contacts 2 NO 2 NO 2 NO 2 NO Operation Inst DTL DTL DTL Latched No Select Select Select Contact ratings Make and carry within limits of L/R = 50ms, and 300V max: for 0.5s 20Aa.c. or d.c for 0.2s 30Aa.c. or d.c Carry continuously: 5Aa.c. rms or d.c. Break within limits of 5A and 300V maximum: a.c. resistive 1250VA, a.c. inductive 250VA PF 0.4 min, d.c. resistive 50W d.c. inductive 30W L/R = 40ms, 50W L/R = 10ms. Minimum recommended load 500mW (Lower limits of 10mA and 5V) Minimum number of operations 1000 at maximum load Normally open contacts are wired via case trip-isolation contacts and normally closed contacts are wired via case shorting-contacts. Siemens Protection Devices Limited 4

Fig 1. Diagram of DAD relay. Siemens Protection Devices Limited 5

Ordering Information 7PG26 DAD Product description Variants Order No. DAD 7 P G 2 6 - A A 0-0 A 0 High impedance circulating current protection. Relay type DAD - 3 phase unit with integral current 1 transformer supervision and time delay Voltage range 18V to 60V DC 1 88V to 280V DC 2 Nominal current 1A 1 5A 2 Frequency 50Hz 1 60Hz 2 Housing size Case size E6 (4U high) D 1) Schemes require external stabilising resistors and metrosils, see 7XG series ancillary equipment list Siemens Protection Devices Limited 6

Siemens Protection Devices Limited 7

Published by and copyright 2010: Siemens AG Energy Sector Freyeslebenstrasse 1 91058 Erlangen, Germany Siemens Protection Devices Limited P.O. Box 8 North Farm Road Hebburn Tyne & Wear NE31 1TZ United Kingdom Phone: +44 (0)191 401 7901 Fax: +44 (0)191 401 5575 www.siemens.com/energy For more information, please contact our Customer Support Center. Phone: +49 180/524 70 00 Fax: +49 180/524 24 71(Charges depending on provider) E-mail: support.energy@siemens.com Power Distribution Division Order No. E53000-K7076-C17-1 Printed in Fürth Printed on elementary chlorine-free bleached paper. All rights reserved. Trademarks mentioned in this document are the property of Siemens AG, its affiliates, or their respective owners. Subject to change without prior notice. The information in this document contains general descriptions of the technical options available, which may not apply in all cases. The required technical options should therefore be specified in the contract. www. siemens.com/energy Siemens Protection Devices Limited 8