INSTALLATION & MAINTENANCE

Similar documents
SLT-Series Installation and maintenance instructions

S-Series. Protect your water from pathogens and disease with the UV-Guard S-Series. Protect:

S-Series Installation and maintenance instructions

Installation & operating manual. Swimming pool water. UV disinfection device UV10+

INSTALLATION AND OPERATING INSTRUCTIONS FOR RW519 RAIN WATER FILTRATION SYSTEM

UV I UNIT030W / UV I UNIT055W

A measured step forward

VMS-3. Part Number: Ultraviolet Systems VMS-3. Installation, Operation & Maintenance

1020 Industrial Drive, Orlinda, TN fax

Instruction Sheet DANGER

Ultraviolet (UV) Water Treatment System

SUPER NOVA SERIES UV STERILIZER HIGH INTENSITY ULTRAVIOLET STERILIZATION

UV Lamp and Quartz Sleeve Replacement/Maintenance

WATER STERILIZERS TYPE: AM1; AM2; AM3; AM4; AM5; AM6; AM8; AM10; AM12; AM15

Instruction Sheet DANGER

Pro-MAX Ultraviolet Sterilizer

Ultraviolet Water Sterilizer Installation and Maintenance Manual

Owner s Manual. DO NOT REMOVE FROM UNIT See back cover for vital records

BWT ECO. Fitting and operating instructions. Ultra Violet Water Disinfection System. ECO Range: LC 8 UV LC19 UV LC36 UV LC51 UV

BALLAST REPLACEMENT. Contents WARNING INSTALLATION MANUAL

375 Marcus Boulevard Hauppauge, NY USA Fax: Extensive Product Information Available at:

Instructions for Emperor Aquatics, Inc. s 16, 25, & 57 Watt Retro-Fit UV Sterilizer (for Savio s Skimmers)

I N S T A L L A T I O N, O P E R A T I O N, M A I N T E N A N C E M A N U A L UVR SERIES ULTRAVIOLET WATER TREATMENT SYSTEM

Instruction Sheet. VIQUA UVMAX Lamp and Quartz Sleeve Replacement

Getting Started Quick Reference Guide

PRE INSTALLATION PROCEDURES

Model CWA200 Owner s Manual

254 Nanometer Germicidal UV Disinfection Systems

AEM EASY DRUM M A N U A L

Professional Amalgam Non-regulated

ALL IN ONE SERIES HOTLINE 1300 AQUATEC INSTRUCTION MANUAL MODEL 03AS310 03AS311. DATE JULY 2017 v2.0. AQP All in One 1000 Instructions.

Bio-Logic. Owner s Manual. Installation, Operation & Maintenance ULTRAVIOLET WATER PURIFIERS. Ballast 120v 50/60 Hz

HydroRite UVO 3. Troubleshooting Guide Residential. TSG-UVO158a. Copyright 2015 Hayward Industries Inc.

PRE INSTALLATION PROCEDURES

WEDECO DLR A SERIES ULTRAVIOLET WATER DISINFECTION UNIT INSTALLATION OPERATION AND MAINTENANCE MANUAL MODELS DLR-A SERIES NO'S

Ultraviolet Systems UV-C 50 INSTALLATION INSTRUCTIONS & PRODUCT MANUAL

Safety Warnings. Work area safety. Electrical Safety. Personal Safety

Ultraviolet Disinfection Unit Installation and Owners Manual

PJ130S High Pressure Cleaner

Design and manufacture process of DUV units comply with international standards for UV disinfection of potable water such as CE certificate.

Installation, Operating and Maintenance Guide

Models 120v 50/60 Hz 230v 50/60Hz MIN B A MIN B A MIN B A

METIS. Installation instructions. Riser rail kit INSTALLERS PLEASE NOTE THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER.

ADVANCE Ultraviolet (UV) Water Treatment System

SERVICE REQUIREMENTS

Conduit ~15" Inlet. UV Sterilizer - Connection to Forcemain

Autofill counter top water boiler

HF Series R_RevB

READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

NANO TECH UV-C DISINFECTION SYSTEM

ENGLISH (Original instructions) INSTRUCTION MANUAL. Demolition Hammer HM0810TA DOUBLE INSULATION. IMPORTANT: Read Before Using.

Ballast MIN A

2 BURNER LP GAS STOVE OPERATING INSTRUCTIONS

Ozone + UV Sanitation

PRECISION PRECISION. Installation and Operating Instructions FLOW. AUTOMATIC REGULATOR

- Do not Discard these instructions; please save them for later use/reference.

INSTALLATION MANUAL & OWNER S GUIDE. Stainless Steel Ultraviolet Water Purification System

Vorton 11/18/36/55 2YEAR. GUARANTEE. Hozelock Ltd. Midpoint Park, Birmingham, B76 1AB. England Tel: +44 (0)

Operating instructions Page 12

Owner s Manual. Model: Powered by. D4 Validated Models: D4-V _RevAC

Autofill wall mounted water. boiler. Getting the best from your water. boiler. Please read and keep these instructions

WEDECO Quadron UV System

VIQUA is an ISO9001:2008 registered company specializing in the design, manufacture and sale of ultraviolet systems for:

Ballast 230v 50/60Hz MIN B B MIN B B MIN B B

WL380 QUICK START GUIDE

Table of Contents. English

Mechanical seals external, single or double, to DIN EN 12756

SimplyClear Pressurized Filter Product Manual

Ultraviolet (UV) Disinfection System Model RC8

VADA - Rain2Main Automatic Rainwater Controller

Section 3: Ultraviolet - UV

Moisture inside the drum is due to final testing.

INFRARED IP55 HEATER INSTRUCTIONS FOR: MODEL:- QZWP45N 1. SAFETY INSTRUCTIONS

User s Guide REO-MECH. Industrial Rebar Benders & Cutters

SHORT WAVE INFRARED PANEL DRYER

1. CONDITIONS FOR USE 2. SAFETY

INSTALLATION & USER INSTRUCTIONS

PRE-INSTALLATION PROCEDURE

BIOSHIELD COMMERCIAL VERTICAL UV STERILIZER

BUILT-IN 60CM WHITE UNDERCOUNTER LARDER KIL60W14. installation / instructions manual

Heater Upgrade Instructions

OPERATING AND MAINTENANCE MANUAL

APW-VAP-150P High Pressure Cleaner Operator Manual

Refrigerator Freezer HD-368RWEW

MK 8706 / MB 8706 CONCEALED THERMOSTATIC SHOWER VALVE INSTALLATION GUIDE

* If the infiniti UV Water Treatment System has an S2 Starter, it is fully interchangeable with the UV Lamp with Glow Starter.

Operating instructions

1. SAFETY WARNINGS INSTALLTION Location Reversing the Door Swing Levelling the Unit... 3

Power Wash 2000W Car. User Guide. HPW2C-ZA hoover.za.com. Version 1.0

Owner s Manual. Healthy, clean and safe. Installation, Operation and Maintenance

Lo-Carbon T-series Window & Roof Models

CINCINNATI, OH USA

Contents. 1. Instructions for safety and use 20

Sema thermostatic bar mixer Installation and operating instructions

AllClear G2 Series Pressurized Filters Product Manual

NENE. Installation and Operating Instructions. Thermostatic bar mixer shower PLEASE NOTE THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER

READ THIS MANUAL PLEASE KEEP FOR PERMANENT REFERENCE. Part No , Revised

Prizmatix UV Torch. User Manual

Qualcast 430W Grass Trimmer (Model: GT2826)

OPERATING & MAINTENANCE MANUAL DC10 DC15 DC25 DC40 DC45

Transcription:

INSTALLATION & MAINTENANCE MODELS: UVG SLT 2 (GT7-2UVG) UVG SLT 30 (GT7-4UVG) UVG SLT 40 (GT7-8UVG) UVG SLT 75 (GT7-13UVG) UVG SLT80 UVG SLT125 (GT7-15UVG) and UVG SLT 172 Stainless Steel Water Disinfection Units NOTE: Please read this manual carefully and follow the instructions. Installation shall be carried out only by authorised technicians. Power Supply should always be plugged into a surge protector. CONTENTS 1. INTRODUCTION 1.1 General Safety Instructions 2. ASSEMBLY AND INSTALLATION 2.1 Reactor 2.1.1 Installing the Reactor 2.2 Installing the Power Box 2.3 Installing the Quartz Thimble and UV Lamp 3. SERVICING 3.1 Servicing the Quartz Thimble 3.2 Servicing the UV Lamp 4. WARRANTY

INTRODUCTION UV disinfection is an efficient, low cost and environmentally friendly process. UV light kills pathogenic micro-organisms quickly without leaving any residues, harmful by-products or affecting the smell or taste of the water. These units use UV lamps which emit UVC radiation at 254nm which disrupts the DNA in the micro-organisms, so they are either killed or their ability to replicate is destroyed. The kill rate depends on the UV dose received by the micro-organisms, i.e. the time that a micro-organism is exposed to a certain intensity of UV radiation (Wm 2 ). A UV dose of 400 J/m 2 is recognized internationally as a suitable dose to ensure safe disinfection of drinking water. The disinfection performance of a UV system is determined by the intensity of the UV light, water flow rate, the optical transmission of the water at 254nm and the geometry of the reactor. The sizing of the UV system should be based on these parameters. Please contact your UV- Guard representative if you have any queries regarding correct sizing. As there are no disinfection substances added to water by UV radiation, there are no residual effects once the water has passed through the UV Reactor. Only genuine spare parts should be used to ensure proper operation and performance. 1.1 General Safety Instructions ELECTRIC SHOCK! Attention: Dangerous electric voltage is present inside the power supply box and chamber. These instructions must be followed closely to prevent serious personal injuries. ENSURE EYE PROTECTION IS WORN WHEN SERVICING AND INSTALLING THIS UNIT! UV-C radiation is harmful to the eyes and skin! UV lamps should be used only when properly installed in the irradiation chamber. The UV lamp must never be operated outside the disinfection chamber. Make sure this disinfection unit is only used for the intended purpose as described in the operating instructions. This disinfection unit is to be installed properly, according to these operating instructions, before use. Do not use a unit with a damaged electrical lead or plug, a unit with any faulty functions, or a unit which has been dropped or has been damaged in some way. Make sure that the unit is unplugged when it is not being used, before fitting, or removing any parts, or before cleaning the unit. Ensure the disinfection unit is electrically isolated before: A. Carrying out repairs. B. Cleaning. C. Replacement of the UV lamp

The unit must be depressurized before maintenance. Do not use the UV lamp outside of the UV disinfection reactor. UV lamps are designed for permanent operation to reach their best disinfection capacity. Frequent switching on and off reduces the life of the UV lamp! 1. ASSEMBLY AND INSTALLATION Installation should be carried out only by qualified technicians. The Following MUST be checked Prior to Installation: A maximum operating pressure of 800KPa (8 bar or 125 psi) must not be exceeded. The maximum ambient temperature is 45 o C The maximum water temperature should be 40ºC The maximum flow rate should not exceed specified rate The Reactor must be plumbed so it remains full of water at all times while the lamp is operating. The SLT series units should not be installed so there are long periods with no flow. Recommended maximum period with no flow is 60 minutes. Longer periods for the UVG SLT 125, may damage the UV lamp due to overheating. If there are going to be long periods with no flow for these units, it is recommended a thermostat controlled valve is installed downstream of the UV unit so that if the temperature of the UV reactor gets too hot, the valve will open to return a small amount of water to the source, or dump to waste. The water flow from this action will cool the reactor. 2.1 Reactor 1. The following reactor types are available in the SLT series. Series Length No. Lamps in unit Diameter mm SLT 2 400mm 1 62 SLT 30 505mm 1 62 SLT 40 895mm 1 62 SLT 75 895mm 1 62 SLT 80 895mm 1 88 SLT 125 895mm 1 88 SLT 172 895mm 1 88 Table 1.

Series Inlet/outlet Ø Min. space to service reactor at power end of chamber mm * Max. flow rate l/h - Drinking water SLT 2 ¼ BSP Nipples 300 500 250 SLT 30 ¾ BSP Nipples 600 2000 500 SLT 40 1 BSP Nipples 1000 2,700 2000 SLT 75 1 BSP Nipples 1000 5,400 4000 SLT 80 2 BSP Nipples 1000 * 8,200 NA SLT 125 2 BSP Nipples 1000 * 13,000 NA SLT 172 2 BSP Nipples 1000 * 16,900 NA Max. flow rate l/h - Treated effluent Table 2. * Space is also required at the blank end of the chamber for servicing the quartz thimble for the SLT80, SLT 125 and SLT 172 units. A 100 mm space will be sufficient. 2.1.1 Installing the Reactor Before installation ensure you know which reactor type you are using. Make sure that there is enough free space to service the glassware with the reactor (see Table 2.). Otherwise it will not be possible to install the UV lamp and maintain the UV system. The reactor is to be fixed by means of the mounting legs, either on the wall or on a mounting frame. The disinfection chamber comes complete with it's own wall mounting brackets The preferred orientation for the reactor is horizontal, however vertical orientation is acceptable. The in-outlet ports should be pointing up for horizontal installations, or the outlet should be the top port in vertical installations, to prevent airlocks. Refer to Table 1 for the distance from the sealing nut, required for servicing the unit. When mounting the chamber, consideration must be made for the weight of the system due to the stresses associated with pipe work etc. The stainless steel chamber and surrounding pipe-work must be properly earthed to prevent electrolysis/corrosion.

2.2 Installing the Power Box The power supply box must be mounted clear of the floor as a precaution against the ingress of water. The power supply box is not designed for remote mounting. Recommended maximum distance of chamber to power supply box is two (2) metres. Depending on which version of the power supply box is ordered, there may be an audible lamp fail alarm included. This will sound in the event of a lamp failure to notify the operator to replace the UV lamp. The power supply box should be mounted so it is not exposed to rain or direct sunlight. Power supply 40048 (40088) Power supply 50162 Power supply 50044 (50081) Power supply 40044 For UVG SLT30, 40 (75 and 80) For UVG SLT125 For UVG SLT30, 40 (75 & For UVG SLT30 and 40 Must be installed under cover Can be installed in 80). Can be installed in Must be installed under cover weather away from weather away from direct sunlight direct sunlight 2.3 Installing the Quartz Thimble and UV Lamp DUE TO THE FRAGILE NATURE OF THE QUARTZ, CARE MUST BE TAKEN WHEN HANDLING AND INSTALLING THE QUARTZ THIMBLE and UV LAMP. Remove the sealing nut(s) from the reactor and ensure the O ring seal is removed as well. For the UVG SLT 80 and 125 units remove the blind sealing nut from the blind end of the chamber as well

Take the quartz thimble and wipe it down with a soft cloth soaked in methylated spirits to remove any grease and finger marks, then dry it. Insert the domed end of the quartz thimble into the chamber and locate the thimble in its support at the far end of the chamber. For the double ended SLT80 and SLT125 position the quartz thimble so there is equal amounts of quartz sticking out of each end of the chamber. Reactor Sealing Nipple Quartz Thimble For SLT 80 and SLT 125 double ended chambers, the quartz needs to be centred so there is an equal amount at each end For single ended chambers the quartz needs to be located so there is a maximum of 14mm protruding from the end of the chamber when the support spring is fully compressed. Place an O ring over the quartz so the O ring is positioned against the chamfer on the sealing nipple. For the double ended SLT80 and SLT125 there is an O ring at each end of the chamber. O Ring seal For SLT 80 and SLT 125 double ended chambers, an O ring needs to be placed over each end of the quartz For single/double ended chambers an O ring needs to be placed around the quartz so it is against the chamfer on the sealing nipple. For double ended chambers the blind sealing nut needs to be screwed on the chamber over the domed end of the thimble. The open sealing nut needs to be screwed on to the chamber over the open end of the quartz thimble. The sealing nuts should be tightened to firm hand tightness. They should not be tightened with a mechanical aid such as multi-grips. Look through the sealing nut to check the O ring is compressed on to the quartz thimble. At this stage the quartz is sealed and the unit should be checked for leaks against the operating pressure. Blind Sealing Nut Check compression on O Ring Open Sealing Nut For SLT 80 and SLT 125 double ended chambers, blind sealing nut needs to be screwed on over the domed end of the quartz For single/double ended chambers the open sealing nut needs to be screwed on over the open end of the quartz thimble. Double ended chamber with quartz installed Single ended chamber with quartz installed

Remove the UV lamp from its protective wrapping and wipe down with a soft cloth/tissue soaked in methylated spirits. Do not touch it without protective gloves, care should be taken not to leave markings of any nature on the UV lamp, as this could have a detrimental effect on the performance of the UV lamp. Insert the UV lamp into the quartz thimble through the hole through the centre of the sealing nut. If the chamber is installed vertically, NEVER drop the lamp into the quartz thimble, as this may break the quartz thimble. Place the sealing nut gasket over the UV lamp while always keep a firm hold of the UV lamp until it is secured to its four pin connector. Using a soft cloth, or wearing gloves to hold the UV lamp, push the female 4 pin connector firmly on to the lamp pins. Four pins on lamp UV Lamp Four pin plug, lead & end cap UV Lamp Sealing nut gasket Locate the three holes in the end cap with the three holes on the end of the sealing nut. Screw all three screws (M3) through the holes in the end cap, into the sealing nut. Sealing Nut complete with UV lamp installed and cable secured Return full water pressure to the UV reactor. Insert the power lead into the outlet then turn power on. The UV lamp will ignite and come on, however it will take between 2 and 5 minutes for the lamp to reach full output. 3 SERVICING Servicing should only be carried out by a qualified service technician. The mains power to the UV unit must be switched off and the reactor must be hydraulically isolated and de-pressurised before carrying out any service work. 3.1 Servicing the Quartz Thimble Switch off main power supply to the UV disinfection reactor. Isolate the water supply to the UV reactor. Release pressure and drain water within the reactor. Remove the three screws that secure the electrical cap to the sealing nut. Slide the lamp out enough to be able to remove the four pin plug. Disconnect the four pin plug from the end of the UV lamp. Remove the UV lamp from the reactor and place in a safe place. Unscrew the sealing nut in an anti-clockwise direction and carefully remove it from reactor. Take care with single ended chambers with spring quartz support, as the spring will

suddenly push the quartz out of the chamber when the sealing nut becomes disengaged from the thread on the chamber. Take care to hold on to the quartz thimble as it may come out of the reactor at the same time. Remove the sealing nut from the quartz thimble and store in a safe place. You can then remove the quartz thimble from the reactor. If the thimble is due for a clean, wipe it down with a cleansing cream or similar and then wash down with water. It may be necessary to scrape off the remnants of the old O ring with a sharp knife. Repeat this step until the quartz thimble is clean, then wipe down the quartz thimble with a soft cloth/ tissue that has been soaked in methylated spirits, then dry it. (Take care not to leave any marks on the quartz). Re-assemble the chamber as described in the assembly section. 3.2 Servicing the UV Lamp Switch off the mains power to the UV disinfection unit. The lamp may be hot so allow 10 minutes for the lamp to cool down before handling it. Remove the three screws that hold the end cap in place on the end of the sealing nut. The UV lamp will be attached to the lead that goes through the end cap. Slide the UV lamp out just enough so that you are able to get a firm hold on it, you will then be able to remove the four pin plug that is connected to the end of the UV lamp. After the four pin plug has been removed, you can then remove the UV lamp from the reactor. Reinstall UV lamp as described in the assembly section. 4 GUARANTEE ONE YEAR GUARANTEE FOR THE REACTOR A one (1) year guarantee is issued from the date of purchase for this Stainless Steel Reactor, provided that it is installed and maintained in accordance with our instructions. Faults regarding the material and workmanship of this reactor will be rectified free of charge within the warranty period. This warranty does not cover installations where salt water passes through the reactor. ONE YEAR GUARANTEE FOR POWER SUPPLY A one (1) year guarantee from the date of purchase for the Power Supply, provided that it is installed and maintained in accordance with our instructions. A surge protector should always be used in conjunction with the power supply and to protect device against surges, and validate warranty. ONE YEAR PRO-RATA GUARANTEE FOR ULTRA-VIOLET LAMP The UV lamps are warranted for 12 months of continuous operation. In the case of a technical failure the following replacement/discount applies. * up to one month: full replacement * Over one month, pro rata discount to 12 months This guarantee is based on a maximum of 4 ON/OFF switches per 24 hour period