Radiometric Level Measurement in DCU Challenges, Solutions and Interpretation Author: Dr. Jan Sielk Process Control

Similar documents
Technologies, Solutions, and Applications. Continuous Level Coke Drum Measurement System

Density, Concentration and Solids Content. Non-contacting measurement

Ronan Model X96S Series Weighing System

Efficiency & Savings through On-Line Chemical Cleaning

Nuclear Associates

Fixed-Point Interface Profiling. Multi-Point Density Array (MDA) Solution for Separation Applications

PRODUCT INFORMATION HISIC450 OVERHEIGHT DETECTORS RELIABLE OVERHEIGHT DETECTION OF VEHICLES. Traffic sensors

Personal Radiation Alarm Dosimeter LK Operating Instruction Manual. Contents

Ronan Model X96S Series Density System

dewar or an electrically powered cooler. The sensitive detector surfaces are thus protected from moisture and condensable contaminants.

Thermo Scientific Round Top Hotplate Stirrers. Make safety and accuracy part of your routine

VISION. Introduction. Dear readers and friends,

Return loss measurement of fiber optic components

MaxiCoking Technology Breakthrough Technology for Improved Existing Delayed Coker Performance

WILDLIFE AND ASSET PROTECTION PRODUCTS

RC4000 Radiation Detection System

PRODUCT INFORMATION. GM901 Carbon Monoxide Gas Analyzers CO MEASUREMENT FOR EMISSION MONITORING AND PROCESS CONTROL. In-situ Gas Analyzers

Ronan Model X90 Series Point Level Monitor

Identify the following features and specifications for the ESP1

AND NATURAL GAS DRILLING AND PRODUCTION

BUILD the clinic you ve always imagined.

Expansion vessel in a solar installation. White paper

Continuous and Point Level Measurement. Radiometric Sensors for Liquid and Solid Level Measurement

Protecting Critical Facilities Against Explosions

SEC SIGNATURE ETO MONITOR TRAINING SENSOR ELECTRONICS CORPORATION

Feed Interruption Three separate incidents within Marathon petroleum. p Garyville 2005, 05 Coker Unit - Feed interruption/furnace tripped caused by wa

M E A S U R E M E N T S D I V I S I O N

VICOTEC450 EXTRACTIVE VISIBILITY MEASURING DEVICES EXTRACTIVE VISIBILITY MEASUREMENT FOR INCREASED SAFETY IN TUNNELS

Jet ejectors for the oil industries. Vacuum solutions for refineries and the petrochemical industries

Fired Heaters Key to Efficient Operation of Refineries and Petrochemicals

DELAYED COKER UNIT (DCU)

A new fully digital system for RT inspection of metal tube to tube sheet joints of heat exchangers

Temperature Rises as Products Compete in the Heat. Market. Contact: Tim Page Press Release No: 20. Release date: Immediate Date: 11/11/09

DSGH. Radiation-Based Detector with GEN2000 Electronics for Density Measurement QUICK REFERENCE GUIDE

LOW MINIMUM DETECTABLE ACTIVITY (MDA)

Remote Gamma Imaging of High Dose Environments

Small Controlled Area Radiography Fundamentals and Technology Advancements. J. R. Lapinskas, PhD and R. L. Kelly

Chapter 1. Introduction

MULTI-POINT DENSITY ARRAY FIXED-POINT INTERFACE PROFILING MEASUREMENT

An FT-NIR Primer. NR800-A-006

2007 KBC Advanced Technologies plc. All Rights Reserved.

Optimizing Strategy for Boiler Drum Level Control

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

SSC Series Standard Accuracy Plastic Silicon Pressure Sensors ±2 % Total Error Band, Digital Output, SMT and DIP, 1 psi to 150 psi

VOCs in soil remediation

PRODUCT INFORMATION. SureSense THE SURE WAY TO DETECT ANY OBJECT. Photoelectric Sensors

Laser Analyzers for NH3 Safety Monitoring and Leak Detection

Kata products Kata DGM-1500 Turva

MP 601A Humidity Probe INSTRUCTION MANUAL

Products and performance

Protecting Ethylene Process Facilities: A Review of Gas Detection Methods

Welcome to Micro-Epsilon

Energy and Angular Responses of the Criticality Accident Alarm System Using Current-mode-operated Scintillation Detector

AM-806. Waste/Door Radiation Monitor OPERATIONS MANUAL

CONTROL AND MONITORIN

natural refrigerants - global trends & developments

AutoM Click to go to the page. AutoM Auto Shaker Filter

Radiation Safety and Equipment Considerations. Bonnie Meilner Regional Sales Manager LAURUS Systems Inc.

SIL 2. Ultima X Series Gas Monitors CERTIFIED

Shale Oils Designing for Improved Crude Preheat Train Reliability and Performance

KBC Petro-SIM Design Tools Integrated Equipment Operations. Al Shelton - KBC

86BSD Digital Output

THEORY OR OPERATION 2 SENSOR UNIT - MECHANICAL 6 SENSOR UNIT - ELECTRICAL 8 CONTROL UNIT - MECHANICAL 9 CONTROL UNIT - ELECTRICAL 9 OPTIONS 11

North American Technical Services

A FIRST RESPONDERS GUIDE TO PURCHASING RADIATION PAGERS

FILL LEVEL INSPECTION

QUALITY ASSURANCE AND SAFETY AT A TID RADIATION TEST LABORATORY

MODEL 1925-PR TRITIUM HEAVY WATER LEAK DETECTOR

TAKING CHEMICAL MANAGEMENT GLOBAL CMS FORUM SAN FRANCISCO, CA OCTOBER 2006

GMS800 FIDOR TOTAL HYDROCARBON ANALYZER CONTINUOUS MONITORING OF HYDROCARBON EMISSIONS

PORTABLE ISOTOPE IDENTIFIER Search Tool / Sample Counting System

Application Note. Comparison of optical detection systems for Infrared (IR) Hydrocarbon gas detection

NONWOVEN INDUSTRIES. Advanced Web Gauging Solutions. The Measure of Quality

New Features TDLS 200. The Process TDLS Solution. Tunable Diode Laser Spectroscopy (TDLS) Analyzer.

CAST-X Circulation Heater. With optional built-in controls, CAST-X 1000 is a straightforward solution, perfect for OEMs and end users.

The advantages of closed heating systems. White paper

Open-area Smoke Imaging Detector. Engineering Specification

Heat Exchanger Solutions For the oil and gas industry

Setting the new standard for personal radiation detection.

Rota-Sonde DC4000-L. Laser pointer for easy alignment. Remote control of the sensitivity

Key Features. General Description

PROCESS & MECHANICAL DESIGN FOR DISTILLATION COLUMN RELIABILITY

Troubleshooting Thermo Scientific LevelPRO Gauges

Oliver Spaltmann, Senior Market Analyst SMR. Household Appliances

APPLICATION REPORT Isomerisation This diagram is intended to be a representation and should not be viewed as an actual process flow diagram.

Agilent 81663A DFB Laser 8165xA Fabry-Perot Lasers

RAYCHEM SCREENED SEPARABLE CONNECTORS RSTI FOR SWITCHGEARS AND TRANSFORMERS IN MEDIUM VOLTAGE DISTRIBUTION NETWORKS

Low-Cost, Non-Invasive, Microwave-Based Bulk Solids Flow Detector

LEARNING FROM TEXAS CITY REFINERY ( BP )

Sensors and Systems for the Steel Industry

The Growing Viability of UV LED for Wide Web Coating Applications. Tuesday, October 11, 2016

Rain Forest Quick Guide

A WMIA Partner of the Year Winner S-Series Enclosureless Dust Collector

Application of Radioactive Particle Tracking (RPT) and Densitometry for Measuring Liquid Velocity Fields and Void Fraction in Convective Boiling Flows

Live plants and products of floriculture sector in the EU

Learning. Radiation Protection Compliance Safety Assessment

MS1471 SPECIFICATIONS. PC Board Mountable Pressure Sensor 0-60 mv Output Gage and Absolute Low Cost

New emerging technologies for smart textile application

TE S RAYCHEM PLUG-IN TERMINATIONS (RPIT) INNER CONE SYSTEMS FOR SWITCHGEARS AND TRANSFORMERS UP TO 52 kv

Alfa Laval spiral heat exchangers. Problem solvers for tough applications

Transcription:

Radiometric Level Measurement in DCU Challenges, Solutions and Interpretation Author: Dr. Jan Sielk 2017-10

Agenda Company introduction Introduction to radiometric measurements Level measurements in coke drums Requirements Arrangements Challenges and Solutions Uneven coke distribution Scalings Gas properties changes Interference radiation

Who we are Located in Bad Wildbad, South West Germany Family owned company 350 employees worldwide Sales ~70 Million Euro per year Specialized in radiometric process measurements since 1949 >20,000 nuclear gauges in operation Own source production

Who we are Subsidaries in all major markets (e.g. USA, China, UK, France, Italy, Austria, India ) Partner companies all over the world (e.g. South East Europe, Latin America, South East Asia, Russia, Australia, Africa )

Nuclear Measurements Why Gamma? Non-contacting, non intrusive measurement Extreme measurement conditions! High temperatures High pressures Excessive foaming Acid, caustic media Wall build-ups, scaling Long-term solution Virtually maintenance-free Typically no re-calibrations

Typical Fields of Applications Some Nuclear Applications in Refineries Desalter multiphase level measurements Distillation Columns level measurement Coke Drum level measurement Fluid Catalytic Cracking (FCC) level and density measurements Hydrocracker multiphase level measurements Catalytic Reforming (CCR) level measurements Sulfur Removal Technology level measurements

Basic Principle Nuclear Measurements source I 0 object detector I r D source: emits gamma radiation I 0 object: radiation is attenuated detector:measures transmitted intensity I constant density distance I = I 0 exp(-m r D)

Nuclear Level Measurements Level Switch / Point Level For Min / Max alarm detection Narrow radiation beam Point detector Point beam Typically only relay output Very sharp transition

Nuclear Level Measurements Continuous Level Continuous signal (0 100%) Wide radiation beam Rod shaped detector + fan beam or

Nuclear Level Measurements Different Ways of Forming a Radiation Field Detector Source Multiple Combinations Point detector Rod detector Cs-137 or Co-60 Point Source Rod Source

Why to measure level in a coke drum? Timing is essential A typical coking cycle takes several (e.g. 16) hours While one of the two cokers is in filling process, the second must be steamed, quenched, drained, preheated,. There issmall safety reservoir only! Anti-foam is not only costly, overdosing reduces coke quality and can polute the subsequent products and processes Foam spillover will cause coking and tremendous problems and costs in the overhead vapor lines

Arrangements Individual Level Measurements combined in DCS Advantages: Best linearity / accuracy Spatial resolution to detect wall build-ups Detector failure affects only part of the span Disadvantages: Highest cost for devices Most cabling needed (adds cost) Programming of DCS required to calculate overall level Responsibility in customer s hand Customer DCS

Arrangements Cascaded Detectors interconnected and combined level calculated Advantages: Best linearity / accuracy One combined level to DCS Less cabling effort than individual detectors Disadvantages: Highest cost of devices Important aspects: Instruments must be able to deal with high count rates Instruments should detect failures in each detector and report it to the master Self-diagnosis of all detectors should be accessible through the master detector Customer DCS

Arrangement TowerSENS One detector does it all Advantages: Up to 8m with one electronics Lowest cost (device and cabling effort) Covers up to 32m in master/slave arrangement Disadvantages: Reduced linearity (accuracy) of measurement Important aspects: Temperature stability of devices of greater importance

Installation Example at CNOOC Huizhou, China

The Filling Process

Effects during the filling process Sensitive region for level measurement is a 2D-triangle Uneven distribution of coke during the filling process will be indicated differently To avoid: Optimize arrangement, e.g. perpendicular to filling valve

Level indication before filling? How that can happen! Instrumentation faulty? Temperature affects detector reading if not stablilized Internal stabilization failed or faulty Self-diagnostics feature should report this Process related? Chunks / Build-up after emptying of coke drum No spatial resolution! Drum pressurized and calibration without pressure? If it happens repeatedly Recalibrate ( empty adjust ) Improve process or check instrumentation

Calibration Easiest calibration procedure Usually simple two-point calibration is performed at atmospheric pressure First step Empty vessel Source shields open Second step Empty vessel Source shields closed To measure outage compare with measurement after quench!

During operation Effects of pressurized drum Coke rises Also gas pressure hence gas density rises Level indication before filling starts Level indication is higher than actual coke level Can be observed when measuring outage (Coke level measured after draining compared to indication during process) Effect more severe for Cs-137 than for Co-60

Improved Calibration Calibrate under process conditions Pressurize drum! Operating conditions First step Empty vessel Source shields open Second step Empty vessel Source shields closed To measure outage compare with measurement before quench!

Gas Properties Compensation GPC Compensate the gas pressure Gas properties change during the process High gas pressure / density results in absorption Displayed level is higher than real The solution: Measuring the gas phase by using the high level switch Input gas phase to the level detector Correction takes place in the level detector Level is recalculated according to gas conditions during measurement

count rate [cps] Coke Drum Level Measurement Co-60 versus Cs-137 Make your guess first Co-60 has a higher energy (1200 kev) compared to Cs-137 (660 kev). The higher energy of Co-60 is less attenuated so Co-60 0 0,05 0,1 0,15 0,2 density [g/cm³] But anyway none is capable of a foam density measurement Cs-137 0 0,05 0,1 0,15 0,2

Comparison Cs-137 vs. Co-60 Co-60 Cs-137 Energy 1.2 MeV 660 kev Half-life time 5.3 years 30 years Recommended working life 15 years 15 years Effect of scalings Lower Higher Effect of gas properties changes Lower Higher Required activitiy Lower (typically 100-500 mci) Higher (typically 500-2000 mci)

How to avoid problems with nuclear measurements Interfering radiation? Non-destructive testing (NDT) may cause unwanted effects Use of high activity sources (3-80 Ci) mostly Ir-192 Wrong measurement due to excess count rate Too low level will be displayed But: Berthold will recover from interference automatically

Radiation Interference Coke Drum Level Measurement How to avoid problems with nuclear measurements Interfering radiation? X-ray Interference Protection (XIP)! Berthold detectors do not get destroyed from excessive radiation! Freeze the process value, when rapid and large changes are detected: I > 1.5 * I 0 I > I m + n * (I), (n > 8) Standard feature that can (and must) be activated No additional detector required! CPS CPS Limit distance = n * I m = Averaged CPS I = Live CPS Limit time Do not confuse it with our LB 440-RID! Here the measurement is continued with a lower sensitivity during NDT. Only available for LB 440 with Co-60. time

References India, Indian Oil Corporation Limited Brazil, Petrobras Belgium, Exxon Mobil Antwerp India, Essar Oil Barauni refinery Germany, BP Gelsenkirchen many more Coke Drum level / Fractionator level Coke Drum level Coke Drum level / Fractionator level Coke Drum level

Thanks for your attention!