CHAPTER 14 REFERENCED STANDARDS TABLE 14-1 REFERENCED STANDARDS. Floor-Affixed Supports for Off-the-Floor Plumbing Fixtures for Public Use

Similar documents
CHAPTER 14 REFERENCED STANDARDS TABLE REFERENCED STANDARDS PRE-PRINT. STANDARD NumBER STANDARD TiTLE APPLiCATioN

CHAPTER 14 REFERENCED STANDARDS TABLE REFERENCED STANDARDS STANDARD NUMBER STANDARD TITLE APPLICATION

2012 UPC STANDARDS TASK GROUP

STANDARDS TASK GROUP REPORT

Read Only Copy Not For Distribution. Chapter 19. Referenced Standards 19.1 REFERENCED STANDARDS 19.2 STANDARDS ORGANIZATIONS

CHAPTER 14 MANDATORY REFERENCED STANDARDS TABLE 14-1

MECHANICAL TESTING LABORATORY LIST OF APPROVED LISTING AND TESTING AGENCIES

MECHANICAL TESTING LABORATORY LIST OF APPROVED LISTING AND TESTING AGENCIES

ASME STANDARDS IN MODEL CODES

2016 Uniform Solar Energy & Hydronics Code Technical Committee Meeting IAPMO World Headquarters, Ontario, CA October 26, 2016 AGENDA

PLUMBING FIXTURES CHAPTER 27

CHAPTER 15 REFERENCED STANDARDS. Air-Conditioning, Heating and Refrigeration Institute 4100 North Fairfax Drive, Suite 200 Arlington, VA 22203

1 WATERMARK CERTIFICATION SCHEME SCHEDULE OF PRODUCTS This document was adopted 1 August 2017 and replaced the WaterMark Schedule of Specifications

Union County Vocational - Technical Schools Scotch Plains, New Jersey

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

Summary of BBS Proposed Ohio Plumbing Code Rule Changes October 2016

CHAPTER 15 REFERENCED STANDARDS. Air-Conditioning, Heating and Refrigeration Institute 4100 North Fairfax Drive, Suite 200 Arlington, VA 22203

(a) Flame shall not spread to the outer extremities of the sample on the 8 ft 12 ft (2440 mm 3660 mm) wall. Flashover shall not occur.

TABLE OF CONTENTS Limitations of Authority...6 Table Swimming Pool, Spa, and Hot Tub Permit Fees...7

A. This Section includes the following domestic water piping specialties:

Matrix of changes for the National Standard Plumbing Code July 2013

Building Utilities 1 Plumbing and Sanitary Systems

PERFORMANCE TECHNICAL SPECIFICATION *************************************************************************** SECTION D20 PLUMBING 02/18

SECTION DOMESTIC WATER PIPING SPECIALTIES

TABLE OF CONTENTS. CHAPTER 2 DEFINITIONS General Applicability Definition of Terms General...

TABLE OF CONTENTS. Tentative Agenda. Tentative Order of Discussion. A2L Task Group Report III. Uniform Mechanical Code Change Public Comments

SECTION (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS

2016 Plumbing Supplemental Plan Review List

ICP Plumbing Exam. Name: Carefully read each question and then circle the letter of the best answer.

PLUMBING FIXTURES Reserved

CHAPTER 15 REFERENCED STANDARDS SECTION MC 1502 STANDARDS. Number Title section number Manual D 95 Residential Duct Systems

PERFORMANCE TECHNICAL SPECIFICATION *************************************************************************** SECTION D20 PLUMBING 02/18

Read Only Document Not For Distribution

TABLE OF CONTENTS Limitations of Authority...6 Table Plumbing Permit Fees...7

Sanitary Drainage Systems

TABLE OF CONTENTS. CHAPTER 2 DEFINITIONS General Applicability Definition of Terms General...

CHAPTER 17 STANDARDS STANDARDS Broadway, New York, NY 10018,

CUSTOMIZED TEACHER ASSESSMENT BLUEPRINT PLUMBING. Test Code: 5924 Version: 01

Level I Chapter 1 Worksheet

Read Only Copy Not For Distribution. Chapter 10. Water Supply and Distribution 10.1 QUALITY OF WATER SUPPLY 10.2 RESERVED 10.

DESIGN STANDARDS SECTION PLUMBING FIXTURES AND EQUIPMENT. 1.3 Wall hung toilet room fixtures. Urinals for handicapped may be stall type.

PERFORMANCE TECHNICAL SPECIFICATION *************************************************************************** SECTION D20 PLUMBING 02/18

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 22 PLUMBING. A. This Section includes the following sanitary drainage piping specialties:

Internal Use Only INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS IAPMO GUIDE CRITERIA FOR

DESIGN STANDARDS SECTION Toilet rooms and utility rooms to have floor drains at lowest point.

BACKFLOW PREVENTION GUIDE FOR COMMERCIAL, INSTITUTIONAL AND INDUSTRIAL DEVELOPMENTS

Work Order Number PERFORMANCE TECHNICAL SPECIFICATION *************************************************************************** SECTION D20

Plumbing Technology/Plumber CIP Task Grid

Test Code: 8117 / Version 1

SECTION GENERAL-SERVICE COMPRESSED-AIR SYSTEMS

A. All fixtures shall meet the requirements of ANSI A117.1, ANSI Z124.2 and the State of Texas Accessibility Standards (TAS).

DOMESTIC WATER PACKAGED BOOSTER PUMPS

Committee Input No. 5-NFPA [ Chapter 14 ]

SECTION BASIC MATERIALS AND METHODS

Perkins Statewide Articulation Agreement. Documentation item: Secondary Competency Task List Coversheet

MATERIALS Traps TRAPS. No. IPC IRC Description

CHAPTER 15 REFERENCED STANDARDS

SECTION LABORATORY and DE-IONIZED WATER SYSTEMS STANDARD CONSTRUCTION STANDARD

TRUMAN STATE UNIVERSITY PRESIDENT S RESIDENCE RENOVATION

2015 UPC Chapter 8 Indirect Wastes RV

Read Only Document Not For Distribution

PLUMBING CURRICULA OUTLINE

1 Exam Prep Plumbing State Contractors Practice Exam 2

SECTION PLUMBING FIXTURES

B. Shop Drawings: Include diagrams for power, signal, and control wiring.

DESIGN AND CONSTRUCTION STANDARDS GENERAL DESIGN GUIDELINES

CHAPTER 10 TRAPS AND INTERCEPTORS

1 Exam Prep Plumber s Handbook Tabs and Highlights

UNIFIED FACILITIES GUIDE SPECIFICATIONS

A. Section Joint Sealants: Seal fixtures to walls and floors.

plumbing for greywater

SECTION HYDRONIC PIPING

WATERSTONE ASSISTED LIVING AND MEMORY CARE

2015 UPC CODE - CHAPTER 8 INDIRECT WASTES

DOCUMENT TABLE OF CONTENTS

PLUMBING REQUIREMENTS

SAFETY PLUMBING PACKAGES. Quality Products & Value Packages SUSTAINABILITY. Residential Solutions ANTI-SCALE SYSTEMS FIRE PROTECTION

Design and Construction Standards SECTION PLUMBING EQUIPMENT

1. Division 22 Section "Emergency Plumbing Fixtures." 2. Division 22 Section "Drinking Fountains and Water Coolers."

$0.98 $ KITCHEN SINK STRAINER, 3-1/2" x BATH TUB DRAIN, 1-15/16" x 2-3/4" x $ $1.89

AIRPORT PLUMBING DESIGN STANDARDS REV. 2 11/02/2015

DUKE UNIVERSITY CONSTRUCTION STANDARDS

Mechanical Inspection Plumbing

SPRINKLERS TABLE OF CONTENTS

NFPA 54 UPDATE. Paul Cabot American Gas Association

SCHOOL DISTRICT PALM BEACH COUNTY BUILDING DEPARTMENT PLAN REVIEW CHECK LIST -- PLUMBING

SECTION WET-PIPE SPRINKLER SYSTEMS

Flow Control for Fire Protection

FIXTURES, FAUCETS AND FIXTURE FITTINGS

APPENDIX J ILLUSTRATIONS

SECTION PLUMBING EQUIPMENT

SECTION PLUMBING

Flow Control for Fire Protection

CHAPTER 2 DEFINITIONS. Back-Siphonage The flowing back of used, Backwater Valve A device installed in a drainage. bathtub.

SCOPE OF ACCREDITATION TO ISO/IEC 17065:2012

THE JAMES RUSHTON EARLY LEARNING AND FAMILY SUCCESS CENTER #2616 ISSUE FOR CONSTRUCTION

8501 E. Pleasant Valley Rd. Cleveland, OH 44131

SECTION PLUMBING EQUIPMENT

Planting Irrigation

Transcription:

CHAPTER 14 STANDARDS 1401.0 General. 1401.1 Standards. The standards listed in Table 14-1 are intended for use in the design, testing, and installation of materials, devices, appliances, and equipment regulated by this code. AASHTO M36-1991 Corrugated Steel Pipe and, Zinc Coated or Piping, Ferrous 1101.3.2 Aluminum Coated AASHTO M196-1992 Corrugated Aluminum Alloy and Piping 1101.3.2 AASHTO M218-1987 Corrugated Steel Pipe and, Zinc Coated Piping, Ferrous 1101.3.2 AASHTO M252-2002 Corrugated CPE Tubing and Piping, Plastic 1101.3 AASHTO M274-1987 Corrugated Steel Pipe and, Aluminum Coated Piping, Ferrous 1101.3.2 AASHTO M294-2004 Corrugated CPE (Heavy Duty) Piping, Plastic 1101.3 AHAM DW-1-2010* Household Electric Dishwashers Appliances 301.1.3, 301.2 AHAM FWD-1-2009* Food Waste Disposers Appliances 301.1.3, 301.2 ASME A13.1-2007* Scheme for the Identification of Piping Piping 301.1.3, 301.2 ASME A112.1.2-2004* Air Gaps in Plumbing (For Plumbing Fixtures and Table 6-2 Water-Connected Receptors) ASME A112.1.3-2000 Air Gap for Use with Plumbing Fixtures, Appliances, Table 6-2 and Appurtenances ASME A112.3.1-2007* Stainless Steel Drainage for Sanitary DWV, Storm, Piping, Ferrous Table 7-1 and Vacuum Applications, Above- and Below Ground ASME A112.3.4-2000 Macerating Toilet and Related Components Fixtures 301.1.3, 301.2 (R2010)* (R2004)* ASME A112.4.1-2009* Water Heater Relief Valve Drain Tubes Appliances 301.1.3, 301.2 ASME A112.4.2-2009* Water Closet Personal Hygiene Devices Fixtures 301.1.3, 301.2 ASME A112.4.3-1999 Plastic for Connecting Water Closets to the Sanitary 301.1.3, 301.2 Drainage System ASME A112.4.7-2002* Point of Use and Branch Water Submetering Miscellaneous 301.1.3, 301.2 ASME A112.4.14-2004 Manually Operated, Quarter-Turn Shutoff Valves for Use in Valves 301.1.3, 301.2 (R2010) Plumbing (R2010)* ASME A112.6.1M-1997 (R2008) ASME A112.6.2-2000 (R2010)* ASME A112.6.3-2001 (R2007)* ASME A112.6.4-2003 Floor-Affixed Supports for Off-the-Floor Plumbing Fixtures for Public Use Fixtures 301.1.3, 301.2 Framing-Affixed Supports for Off-the-Floor Water Closets Fixtures 301.1.3, 301.2 with Concealed Tanks Floor and Trench Drains DWV Components 301.1.3, 301.2 Roof, Deck, and Balcony Drains DWV Components 301.1.3, 301.2 ASME A112.6.7-2010* Sanitary Floor Sinks Fixtures 301.1.3, 301.2 ASME A112.6.9-2005 Siphonic Roof Drains DWV Components 301.1.3, 301.2 (R2010)* ASME A112.14.1-2003 ASME A112.14.3-2000 (R2004)* TABLE 14-1 STANDARDS Backwater Valves Valves 301.1.3, 301.2 Grease Interceptors Fixtures 301.1.3, 301.2 111

STANDARDS ASME A112.14.4-2001 (R2007)* Grease Removal Devices Fixtures 301.1.3, 301.2 ASME A112.14.6-2010* FOG (Fats, Oils, and Greases) Disposal Fixtures 1015.3 ASME A112.18.1- Plumbing Supply 402.6, 603.4.20 2005/CSA B125.1-2005 ASME A112.18.2- Plumbing Waste 301.1.3, 301.2 2005/CSA B125.2-2005 ASME A112.18.6- Flexible Water Connectors Piping 301.1.3, 301.2 2009/CSA B125.6-2009* ASME A112.18.7-1999 Deck Mounted Bath/Shower Transfer Valves with Integral Valves 603.3.6, 603.4.16.1 Backflow Protection ASME A112.19.1- Enamelled Cast Iron and Enamelled Steel Plumbing Fixtures Fixtures 301.1.3, 301.2 2008/CSA B45.2-2008* (R2004)* ASME A112.19.2-2008/CSA B45.1-2008* ASME A112.19.4M-1994 (R2004)* Ceramic Plumbing Fixtures Fixtures 402.1, 402.2, 410.0, 410.4 Porcelain-Enameled Formed Steel Plumbing Fixtures (Supplement 1-1998) Fixtures 401.1, 411.4, 411.5, 411.6, 414.0 ASME A112.19.5-2005* Trim for Water-Closet Bowls, Tanks, and Urinals Fixtures 301.1.3, 301.2 ASME A112.19.7-2006* Hydromassage Bathtub Appliances Fixtures 401.1, 414.0 ASME A112.19.8-2007* Suction for Use in Swimming Pools, Wading Pools, Swimming Pools and 414.4 Spas and Hot Tubs Spas ASME A112.19.9M-1991 Non-Vitreous Ceramic Plumbing Fixtures Fixtures 401.1 (R2002)* ASME A112.19.10-2003 Dual Flush Devices for Water Closets Fixtures 301.1.3, 301.2 ASME A112.19.12-2006 (R2011)* ASME A112.19.13-2001 (R2007)* ASME A112.19.14-2006 (R2011)* ASME A112.19.15-2005 (R2010)* ASME A112.19.19-2006 (R2011)* ASME A112.21.3M-1985 (R2007)* ASME A112.36.2M-1991 ASME B1.20.1-1983 (R2006)* ASME B1.20.3-1976 Wall Mounted, Pedestal Mounted, Adjustable, Elevating, Tilting, and Pivoting Lavatory, Sink, and Shampoo Bowl Carrier and Drainage Waste Fixtures 301.1.3, 301.2 Electrohydraulic Water Closets Fixtures 401.1, 408.0 Six-Liter Water Closets Equipped with a Dual Flushing Fixtures 401.1, 410.0 Device Bathtubs/Whirlpool Bathtubs with Pressure Sealed Doors Fixtures 301.1.3, 301.2 Vitreous China Nonwater Urinals Fixtures 401.1, 402.2.1 Hydrants for Utility and Maintenance Use Valves 301.1.3, 301.2 Cleanouts DWV Components 301.1.3, 301.2 Pipe Threads, General Purpose, Inch Joints 1316.7.1(2) Dryseal Pipe Threads, Inch Joints 301.1.3, 301.2 ASME B16.1-2010* Gray Iron Pipe Flanges and Flanged : Classes 25, 604.1, 604.5, 606.1.2 125, and 250 ASME B16.3-2006* Malleable Iron Threaded : Classes 150 and 300 Table 6-4, Table 7-1 ASME B16.4-2006* Gray Iron Threaded (Classes 125 and 250) Table 6-4 ASME B16.5-2009* Pipe Flanges and Flanged : NPS 1/2 through NPS 24 301.1.3, 301.2 Metric/Inch ASME B16.12-2009* Cast Iron Threaded Drainage Table 7-1 112

STANDARDS ASME B16.15-2006* Cast Copper Alloy Threaded : Classes 125 and 250 Table 6-4 ASME B16.18-2001 Cast Copper Alloy Solder Joint Pressure Table 6-4 (R2005)* ASME B16.22-2001 (R2010)* ASME B16.23-2002 (R2006)* Wrought Copper and Copper Alloy Solder Joint Pressure 1316.5, Table 6-4 Cast Copper Alloy Solder Joint Drainage : DWV Table 7-1 ASME B16.24-2006* Cast Copper Alloy Pipe Flanges and Flanged : 301.1.3, 301.2 Classes 150, 300, 600, 900, 1500 and 2500 ASME B16.26-2006* Cast Copper Alloy for Flared Copper Tubes Table 6-4 ASME B16.29-2007* Wrought Copper and Wrought Copper Alloy Solder-Joint Table 7-1 Drainage DWV ASME B16.34-2009* Valves-Flanged, Threaded, and Welding End Valves 301.1.3, 301.2 ASME B16.39-2009* Malleable Iron Threaded Pipe Unions: Classes 150, 250 and 301.1.3, 301.2 300 (Includes Revision Services) ASME B16.47-2006* Large Diameter Steel Flanges: NPS 26 through NPS 60 301.1.3, 301.2 Metric/Inch ASME B16.50-2001 Wrought Copper and Copper Alloy Braze-Joint Pressure 1316.5 ASSE 1001-2008* Atmospheric Type Vacuum Breakers Backflow Protection Table 6-2 ASSE 1002-2008* Anti-Siphon Fill Valves for Water Closet Tanks Backflow Protection Table 6-2 ASSE 1003-2009* Water Pressure Reducing Valves for Domestic Water Distribution Valves 301.1.3, 301.2 ASSE 1004-2008* Backflow Prevention Requirements for Commercial Dishwashing Backflow Protection 301.1.3, 301.2 Machines ASSE 1006-1986* Residential Use Dishwashers Appliances 603.2.1, 603.3.7, 807.4 ASSE 1007-1986* Home Laundry Equipment Appliances 301.1.3, 301.2 ASSE 1008-2006* Plumbing Aspects of Residential Food Waste Disposer Units Appliances 301.1.3, 301.2 ASSE 1009-1990* Commercial Food Waste Grinder Units Appliances 603.2.1, 603.3.6 ASSE 1010-2004* Water Hammer Arresters Miscellaneous, Water 609.10, 609.10.1 Supply Component ASSE 1011-2004* Hose Connection Vacuum Breakers Backflow Protection 301.1.3, 301.2 ASSE 1012-2009* Backflow Preventers with an Intermediate Atmospheric Vent Backflow Protection 301.1.3, 301.2 ASSE 1013-2009* Reduced Pressure Principle Backflow Preventers and Reduced Backflow Protection Table 6-2 Pressure Principle Fire Protection Backflow Preventers ASSE 1014-2005* Backflow Prevention Devices for Hand-Held Shower Backflow Protection 301.1.3, 301.2 ASSE 1015-2009* Double Check Backflow Prevention Assemblies and Double Check Fire Protection Backflow Prevention Assemblies Backflow Protection Table 6-2 ASSE 1016-2005* Automatic Compensating Valves for Individual Showers and Valves 419.0 Tub/Shower Combinations ASSE 1017-2009* Temperature Actuated Mixing Valves for Hot Water Distribution Valves 301.1.3, 301.2 ASSE 1018-2001* Trap Seal Primer Valves-Potable Water Supplied Valves 301.1.3, 301.2 ASSE 1019-2004* Vacuum Breaker Wall Hydrants, Freeze Resistant, Automatic Backflow Protection Table 6-2 Draining Type ASSE 1020-2004* Pressure Vacuum Breaker Assembly Backflow Protection Table 6-2 ASSE 1021-2001 Drains Air Gaps for Domestic Dishwasher Applications Backflow Protection 301.1.3, 301.2 ASSE 1022-2003* Backflow Preventer for Beverage Dispensing Equipment Backflow Protection 603.4.11, Table 6-2 ASSE 1023-1979 Hot Water Dispensers Household Storage Type-Electrical Appliances 301.1.3, 301.2 ASSE 1024-2004* Dual Check Backflow Preventers Backflow Protection 301.1.3, 301.2 113

STANDARDS ASSE 1032-2004* Dual Check Valve Type Backflow Preventers for Carbonated Backflow Protection 301.1.3, 301.2 Beverage Dispensers, Post Mix Type ASSE 1035-2008* Laboratory Faucet Backflow Preventers Backflow Protection 301.1.3, 301.2 ASSE 1037-1990 Pressurized Flushing Devices (Flushometers) for Plumbing Backflow Protection 301.1.3, 301.2 Fixtures ASSE 1044-2001* Trap Seal Primer Devices-Drainage Types and Electronic DWV Components 301.1.3, 301.2 Design Types ASSE 1047-2009* Reduced Pressure Detector Fire Protection Backflow Prevention Backflow Protection Table 6-2 Assemblies ASSE 1048-2009* Double Check Detector Fire Protection Backflow Prevention Backflow Protection Table 6-2 Assemblies ASSE 1050-2009* Stack Air Admittance Valves for Sanitary Drainage ASSE 1051-2009 Individual and Branch Type Air Admittance Valves for Sanitary Drainage ASSE 1052-2004* Hose Connection Backflow Preventers Backflow Protection 301.1.3, 301.2 ASSE 1055-2009* Chemical Dispensing Backflow Protection 301.1.3, 301.2 ASSE 1056-2001* Spill Resistant Vacuum Breakers Backflow Protection Table 6-2 ASSE 1057-2001 Freeze Resistant Sanitary Yard Hydrant with Backflow Backflow Protection 301.1.3, 301.2 Protection ASSE 1060-2006* Outdoor Enclosures for Fluid Conveying Components Miscellaneous 301.1.3, 301.2 ASSE 1061-2006* Push-Fit Table 6-4 ASSE 1062-2006* Temperature Actuated Flow Reduction (TAFR) Valves for Individual Fixture Valves 301.1.3, 301.2 ASSE 1066-1997 Individual Pressure Balancing In-Line Valves for Individual Valves 301.1.3, 301.2 Fixture ASSE 1069-2005* Automatic Temperature Control Mixing Valves Valves 419.0 ASSE 1070-2004* Water Temperature Limiting Devices Valves 412.1, 414.5, 417.3 ASSE 1079-2005 Dielectric Pipe Unions Joints ASTM A 47-1999 Ferritic Malleable Iron Castings Piping, Ferrous 301.1.3, 301.2 (R2009) ASTM A 48-2003 Gray Iron Castings Piping, Ferrous 301.1.3, 301.2 (R2008) ASTM A 53/A 53M-2010 Pipe, Steel, Black and Hot-Dipped, Zinc-Coated, Welded, Piping, Ferrous Table 6-4, Table 7-1 and Seamless ASTM A 74-2009 Cast Iron Soil Pipe and Piping, Ferrous Table 7-1 ASTM A 126-2004 Gray Iron Castings for Valves, Flanges, and Pipe Piping, Ferrous 301.1.3, 301.2 (R2009) ASTM A 197-2000 Cupola Malleable Iron Piping, Ferrous 301.1.3, 301.2 (R2006) ASTM A 269-2010 Seamless and Welded Austenitic Stainless Steel Tubing for Piping, Ferrous Table 6-4 General Service ASTM A 312-2009 Seamless, Welded, and Heavily Cold Worked Austenitic Piping, Ferrous Table 6-4 Stainless Steel Pipes ASTM A 377-2003 Ductile-Iron Pressure Pipe Piping, Ferrous 301.1.3, 301.2 (R2008) e1 ASTM A 518-1999 Corrosion-Resistant High-Silicon Iron Castings Piping, Ferrous 301.1.3, 301.2 (R2008) ASTM A 536-1984 (R2009) Ductile Iron Castings Piping, Ferrous 301.1.3, 301.2 ASTM A 653/A 653M- 2010 Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy- Coated (Galvannealed) by the Hot-Dip Process Piping, Ferrous 301.1.3, 301.2 114

STANDARDS ASTM A 733-2003 Welded and Seamless Carbon Steel and Austenitic Stainless (R2009) e1 Steel Pipe Nipples Piping, Ferrous 301.1.3, 301.2 ASTM A 760-1993 Corrugared Steel Pipe Piping, Ferrous 1101.3 ASTM A 861-2004 High-Silicon Iron Pipe and Piping, Ferrous 301.1.3, 301.2 (R2008) ASTM A 888-2009 Hubless Cast Iron Soil Pipe and for Sanitary and Storm Drain, Waste, and Vent Piping Applications Piping, Ferrous Table 7-1 ASTM B 29-2003 (R2009) Refined Lead Joints 301.1.3, 301.2 ASTM B 32-2008 Solder Metal Joints 316.1.3, 1316.7 ASTM B 42-2010 Seamless Copper Pipe, Standard Sizes Piping, Copper Alloy Table 6-4 ASTM B 43-2009 Seamless Red Brass Pipe, Standard Sizes Piping, Copper Alloy Table 6-4, Table 7-1 ASTM B 75-2002 (R2010) Seamless Copper Tube Piping, Copper Alloy Table 6-4, Table 7-1 ASTM B 88-2009 Seamless Copper Water Tube Piping, Copper Alloy 604.3, 903.2.4, 1316.4(1), 1325.4(1), Table 6-4 ASTM B 135-2010 Seamless Brass Tube Piping, Copper Alloy Table 6-4 ASTM B 152-2009 Copper Sheet, Strip, Plate, and Rolled Bar Miscellaneous 301.1.3, 301.2 ASTM B 187-2006 Copper, Bus Bar, Rod, and Shapes and General Purpose Rod, Miscellaneous 301.1.3, 301.2 Bar, and Shapes ASTM B 209-1992 Corrugated Aluminum Pipe Piping 1101.3 ASTM B 251-2010 General Requirements for Wrought Seamless Copper and Piping, Copper Alloy Table 6-4, Table 7-1 Copper-Alloy Tube ASTM B 280-2008 Seamless Copper Tube for Air Conditioning and Refrigeration Piping, Copper Alloy 1316.4(1), 1325.4(2) Field Service ASTM B 302-2007 Threadless Copper Pipe, Standard Sizes Piping, Copper Alloy Table 6-4, Table 7-1 ASTM B 306-2009 Copper Drainage Tube (DWV) Piping, Copper Alloy 903.2.4, Table 7-1 ASTM B 370-2009 Copper Sheet and Strip for Building Construction Miscellaneous 301.1.3, 301.2 ASTM B 447-2007 Welded Copper Tube Piping, Copper Alloy Table 6-4 ASTM B 584-2009a Copper Alloy Sand Castings for General Applications Piping, Copper Alloy 301.1.3, 301.2 ASTM B 587-2008 Welded Brass Tube Piping, Copper Alloy 301.1.3, 301.2 ASTM B 687-1999 Brass, Copper, and Chromium-Plated Pipe Nipples Piping, Copper Alloy 301.1.3, 301.2 (R2005) e1 ASTM B 813-2010 Liquid and Paste Fluxes for Soldering of Copper and Copper Joints 316.1.3 Alloy Tube ASTM B 819-2000 Seamless Copper Tube for Medical Gas Piping, Copper Alloy 1316.4(1), 1325.4(3) (R2006) ASTM B 828-2002 Making Capillary Joints by Soldering of Copper and Copper Joints 1316.9 (R2010) Alloy Tube and ASTM C 14-2007 Nonreinforced Concrete Sewer, Storm Drain, and Culvert Piping, Non-Metallic Table 7-1 Pipe ASTM C 296-2000 Asbestos-Cement Pressure Pipe Piping, Non-Metallic Table 6-4 (R2009) e1 ASTM C 412-2005a Concrete Drain Tile Piping, Non-Metallic 301.1.3, 301.2 ASTM C 425-2004 Compression Joints for Vitrified Clay Pipe and Joints 705.2.1 (R2009) ASTM C 428-2005 Asbestos-Cement Nonpressure Sewer Pipe Piping, Non-Metallic Table 7-1 (R2006) ASTM C 443-2010 Joints for Concrete Pipe and Manholes, Using Rubber Joints 301.1.3, 301.2 Gaskets ASTM C 478-2009 Precast Reinforced Concrete Manhole Sections Miscellaneous 301.1.3, 301.2 ASTM C 564-2009a Rubber Gaskets for Cast Iron Soil Pipe and Joints 705.1.7 115

STANDARDS ASTM C 700-2011 Vitrified Clay Pipe, Extra Strength, Standard Strength, and Piping, Non-Metallic Table 7-1 Perforated ASTM C 1053-2000 Borosilicate Glass Pipe and for Drain, Waste, and Piping, Non-Metallic 301.1.3, 301.2 (R2010) Vent (DWV) Applications ASTM C 1173-2010 Flexible Transition Couplings for Underground Piping Joints 301.1.3, 301.2 ASTM C 1277-2009a Shielded Couplings Joining Hubless Cast Iron Soil Pipe and Joints 705.1.8, 705.1.9 ASTM C 1440-2008 Thermoplastic Elastomeric (TPE) Gasket Materials for Drain, Joints 301.1.3, 301.2 Waste, and Vent (DWV), Sewer, Sanitary and Storm Plumbing ASTM C 1460-2008 Shielded Transition Couplings for Use With Dissimilar DWV Joints 301.1.3, 301.2 Pipe and Above Ground ASTM C 1461-2008 Mechanical Couplings Using Thermoplastic Elastomeric Joints 301.1.3, 301.2 (TPE) Gaskets for Joining Drain, Waste, and Vent (DWV), Sewer, Sanitary, and Storm Plumbing for Above and Below Ground Use ASTM C 1540-2009a Heavy Duty Shielded Couplings Joining Hubless Cast Iron Joints 705.1.8, 705.1.9 Soil Pipe and ASTM D 1527-1999 Acrylonitrile-Butadiene-Styrene (ABS) Plastic Pipe, Schedules Piping, Plastic Table 7-1 40 and 80 (R2005)* ASTM D 1784-2008 Rigid Poly (Vinyl Chloride) (PVC) Compounds and Chlorinated Piping, Plastic 301.1.3, 301.2 Poly (Vinyl Chloride) (CPVC) Compounds ASTM D 1785-2006* Poly (Vinyl Chloride) (PVC) Plastic Pipe, Schedules 40, 80,, Table 7-1 and 120 ASTM D 1869-1995 Rubber Rings for Asbestos-Cement Pipe Joints 705.1.4 (R2010) ASTM D 2104-2003 Polyethylene (PE) Plastic Pipe, Schedule 40 Piping, Plastic 604.1 ASTM D 2235-2004 Solvent Cement for Acrylonitrile-Butadiene-Styrene (ABS) Joints 316.1.6 Plastic Pipe and ASTM D 2239-2003* Polyethylene (PE) Plastic Pipe, (SDR-PR) Based on Controlled Inside Diameter ASTM D 2241-2009* Poly (Vinyl Chloride) (PVC) Pressure-Rated Pipe (SDR Series) ASTM D 2321-2011* Underground Installation of Thermoplastic Pipe for Sewers Piping, Plastic 301.1.3, 301.2 and Other Gravity-Flow Applications ASTM D 2447-2003* Polyethylene (PE) Plastic Pipe, Schedule 40 and 80, Based Piping, Plastic 604.1 on Outside Diameter ASTM D 2464-2006* Threaded Poly (Vinyl Chloride) (PVC) Plastic Pipe, Table 6-4 Schedule 80 ASTM D 2466-2006* Poly (Vinyl Chloride) (PVC) Plastic Pipe, Schedule 40 Table 6-4 (R2011)* ASTM D 2467-2006* Poly (Vinyl Chloride) (PVC) Plastic Pipe, Schedule 80 Table 6-4 ASTM D 2564-2004 Solvent Cements for Poly (Vinyl Chloride) (PVC) Plastic Joints 316.1.6 (R2009) * Piping ASTM D 2609-2002 Plastic Insert for Polyethylene (PE) Plastic Pipe Table 6-4 ASTM D 2657-2007* Heat Fusion Joining of Polyolefin Pipe and Joints 301.1.3, 301.2 ASTM D 2661-2008* Acrylonitrile-Butadiene-Styrene (ABS) Schedule 40 Plastic Piping, Plastic Table 7-1 Drain, Waste, and Vent Pipe and ASTM D 2665-2010* Poly (Vinyl Chloride) (PVC) Plastic Drain, Waste, and Vent Piping, Plastic Table 7-1 Pipe and ASTM D 2672-1996a Joints for IPS PVC Pipe Using Solvent Cement Joints 301.1.3, 301.2 (R2009)* 116

STANDARDS ASTM D 2680-2001 (R2009)* Acrylonitrile-Butadiene-Styrene (ABS) and Poly (Vinyl Chloride) (PVC) Composite Sewer Piping Piping, Plastic Table 7-1 ASTM D 2683-2010* Socket-Type Polyethylene for Outside Diameter- Table 6-4, Table 7-1 Controlled Polyethylene Pipe and Tubing ASTM D 2737-2003* Polyethylene (PE) Plastic Tubing ASTM D 2751-2005* Acrylonitrile-Butadiene-Styrene (ABS) Sewer Pipe and Piping, Plastic 301.1.3, 301.2 ASTM D 2774-2010* Underground Installation of Thermoplastic Pressure Piping Piping, Plastic 301.1.3, 301.2 ASTM D 2846-2009b* Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Hot- and Cold-Water Distribution ASTM D 2855-1996 Making Solvent-Cemented Joints with Poly (Vinyl Chloride) (PVC) Pipe and (R2010)* ASTM D 2996-2001 (R2007) e1 * Filament-Wound Fiberglass (Glass-Fiber-Reinforced Thermosetting-Resin) Pipe Joints 301.1.3, 301.2 Piping, Plastic 301.1.3, 301.2 ASTM D 3034-2008* Type PSM Poly (Vinyl Chloride) (PVC) Sewer Pipe and Piping, Plastic 301.1.3, 301.2 ASTM D 3035-2010* Polyethylene (PE) Plastic Pipe (DR -PR) Based on Controlled Outside Diameter ASTM D 3122-1995 Solvent Cements for Styrene-Rubber (SR) Plastic Pipe and Joints 301.1.3, 301.2 ASTM D 3138-2004 Solvent Cements for Transition Joints Between Acrylonitrile- Joints 301.1.3, 301.2 Butadiene-Styrene (ABS) and Poly (Vinyl Chloride) (PVC) Non-Pressure Piping Components ASTM D 3139-1998 Joints for Plastic Pressure Pipes Using Flexible Elastomeric Joints 316.1.5 Seals ASTM D 3212-2007* Joints for Drain and Sewer Plastic Pipes Using Flexible Elastomeric Joints 705.1.7 Seals ASTM D 3261-2010a* Butt Heat Fusion Polyethylene (PE) Plastic for Polyethylene Table 6-4, Table 7-1 (PE) Plastic Pipe and Tubing ASTM D 3311-2009a* Drain, Waste, and Vent (DWV) Plastic Patterns 301.1.3, 301.2 ASTM D 3753-1990 Glass-Fiber Reinforced Polyester Manholes Miscellaneous 701.2 (R2009)* (R2011)* (R2011)* ASTM D 3965-2005* Rigid Acrylonitrile-Butadiene-Styrene (ABS) Materials for Piping, Plastic 301.1.3, 301.2 Pipe and ASTM D 4068-2009* Chlorinated Polyethylene (CPE) Sheeting for Concealed Miscellaneous 301.1.3, 301.2 Water-Containment Membrane ASTM D 4101-2010a Polypropylene Injection and Extrusion Materials Miscellaneous 301.1.3, 301.2 ASTM D 4551-1996 Poly (Vinyl Chloride) (PVC) Plastic Flexible Concealed Miscellaneous 301.1.3, 301.2 (R2008) e1 * Water-Containment Membrane ASTM D 6104-1997 Determining the Performance of Oil/Water Separators Miscellaneous 301.1.3, 301.2 (R2003) Subjected to Surface Run-Off ASTM E 84-2010b* Surface Burning Characteristics of Building Materials Miscellaneous 701.1(2), 903.1(2), 1101.3 ASTM E 119-2010b* Fire Tests of Building Construction and Materials Miscellaneous 1505.3, 1506.3 ASTM E 814-2011* Fire Tests of Penetration Firestop Miscellaneous 1505.3, 1506.3 ASTM F 402-2005* Safe Handling of Solvent Cements, Primers, and Cleaners Joints 301.1.3, 301.2 Used for Joining Thermoplastic Pipe and ASTM F 405-2005* Corrugated Polyethylene (PE) Pipe and Piping, Plastic 301.0 ASTM F 409-2002 Thermoplastic Accessible and Replaceable Plastic Tube and Piping, Plastic 301.1.3, 301.2 Tubular ASTM F 437-2009* Threaded Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Table 6-4 Pipe, Schedule 80 117

STANDARDS ASTM F 438-2009* Socket-Type Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe, Schedule 40 ASTM F 439-2009* Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe, Schedule 80 ASTM F 441-2009* Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe, Schedules 40 and 80 ASTM F 442-2009* Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe (SDR-PR) ASTM F 480-2006b e1 * Thermoplastic Well Casing Pipe and Couplings Made in Standard Dimension Ratios (SDR), Schedule 40 and Schedule 80 ASTM F 493-2010* Solvent Cements for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe and ASTM F 628-2008* Acrylonitrile-Butadiene-Styrene (ABS) Schedule 40 Plastic Drain, Waste, and Vent Pipe with a Cellular Core Table 6-4 Table 6-4 Piping, Plastic 301.1.3, 301.2 Joints 316.1.6 Piping, Plastic Table 7-1 ASTM F 656-2010* Primers for Use in Solvent Cement Joints of Poly (Vinyl Joints 316.1.6 Chloride) (PVC) Plastic Pipe and ASTM F 667-2006* Large Diameter Corrugated Polyethylene Pipe and Piping, Plastic 301.1.3, 301.2 ASTM F 714-2010* Polyethylene (PE) Plastic Pipe (SDR-PR) Based on Outside Diameter ASTM F 794-2003 Poly (Vinyl Chloride) (PVC) Profile Gravity Sewer Pipe and Based on Controlled Inside Diameter (R2009)* Piping, Plastic Table 7-1 Piping, Plastic Table 7-1 ASTM F 810-2007* Smoothwall Polyethylene (PE) Pipe for Use in Drainage and Piping, Plastic 301.1.3, 301.2 Waste Disposal Absorption Fields ASTM F 876-2010* Crosslinked Polyethylene (PEX) Tubing ASTM F 877-2007* Crosslinked Polyethylene (PEX) Plastic Hot- and Cold-Water Distribution ASTM F 891-2010* Coextruded Poly (Vinyl Chloride) (PVC) Plastic Pipe with a Cellular Core ASTM F 894-2007* Polyethylene (PE) Large Diameter Profile Wall Sewer and Drain Pipe ASTM F 949-2010* Poly (Vinyl Chloride) (PVC) Corrugated Sewer Pipe with a Smooth Interior and ASTM F 1055-1998 Electrofusion Type Polyethylene for Outside Diameter Controlled Polyethylene Pipe and Tubing (R2006)* ASTM F 1216-2009* Rehabilitation of Existing Pipelines and Conduits by the Inversion and Curing of a Resin-Impregnated Tube Piping, Plastic Table 7-1 Piping, Plastic 301.1.3, 301.2 Piping, Plastic 301.1.3, 301.2 Table 6-4, Table 7-1 Piping, Plastic 715.3 ASTM F 1281-2007* Crosslinked Polyethylene/Aluminum/ Crosslinked Polyethylene (PEX -AL -PEX) Pressure Pipe ASTM F 1282-2010* Polyethylene/Aluminum/Polyethylene (PE-AL-PE) Composite Pressure Pipe ASTM F 1335-2004* Pressure-Rated Composite Pipe and for Elevated Piping, Plastic 301.1.3, 301.2 Temperature Service ASTM F 1336-2007* Poly (Vinyl Chloride) (PVC) Gasketed Sewer 301.1.3, 301.2 ASTM F 1412-2009* Polyolefin Pipe and for Corrosive Waste Drainage Piping, Plastic 301.1.3, 301.2 ASTM F 1476-2007* Performance of Gasketed Mechanical Couplings for Use in Joints 301.1.3, 301.2 Piping Applications ASTM F 1488-2009 e1 * Coextruded Composite Pipe Piping, Plastic Table 7-1 ASTM F 1499-2001 Coextruded Composite Drain, Waste, and Vent Pipe (DWV) Piping, Plastic 301.1.3, 301.2 118

STANDARDS ASTM F 1673-2010* Polyvinylidene Fluoride (PVDF) Corrosive Waste Drainage ASTM F 1743-2008* Rehabilitation of Existing Pipelines and Conduits by Pulledin-Place Installation of Cured-in-Place Thermosetting Resin Pipe (CIPP) ASTM F 1807-2010 e1 * Metal Insert Utilizing a Copper Crimp Ring for SDR9 Cross-linked Polyethylene (PEX) Tubing and SDR9 Polyethylene of Raised Temperature (PE-RT) Tubing ASTM F 1866-2007* Poly (Vinyl Chloride) (PVC) Plastic Schedule 40 Drainage and DWV Fabricated ASTM F 1960-2010* Cold Expansion with PEX Reinforcing Rings for Use with Cross-linked Polyethylene (PEX) Tubing ASTM F 1961-2009* Metal Mechanical Cold Flare Compression with Disc Spring for Crosslinked Polyethylene (PEX) Tubing ASTM F 1970-2005* Special Engineered, Appurtenances or Valves for Use in Poly (Vinyl Chloride) (PVC) or Chlorinated Poly (Vinyl Chloride) (CPVC) ASTM F 1974-2009* Metal Insert for Polyethylene/ Aluminum/Polyethylene and Crosslinked Polyethylene/Aluminum/Crosslinked Polyethylene Composite Pressure Pipe ASTM F 1986-2001 Multilayer Pipe Type 2, Compression, and Compression Joints for Hot and Cold Drinking-Water (R2006)* Piping, Plastic 301.1.3, 301.2 Piping, Plastic 301.1.3, 301.2 Table 6-4 Table 7-1 Table 6-4 Table 6-4 Table 6-4 301.1.3, 301.2 ASTM F 2080-2009* Cold-Expansion with Metal Compression-Sleeves for Table 6-4 Crosslinked Polyethylene (PEX) Pipe ASTM F 2098-2008* Stainless Steel Clamps for Securing SDR9 Cross-linked Joints Table 6-4 Polyethylene (PEX) Tubing to Metal Insert and Plastic Insert ASTM F 2159-2010* Plastic Insert Utilizing a Copper Crimp Ring for Joints Table 6-4 SDR9 Cross-linked Polyethylene (PEX) Tubing and SDR9 Polyethylene of Raised Temperature (PE-RT) Tubing ASTM F 2165-2002 Flexible Pre-Insulated Piping Piping, Plastic 301.1.3, 301.2 ASTM F 2262-2009* Crosslinked Polyethylene/Aluminum/ Crosslinked Polyethylene Tubing OD Controlled SDR9 ASTM F 2306-2008 Specification for 12 to 60 in. [300 to 1500 mm] Annular Piping, Plastic 301.1.3, 301.2 Corrugated Profile-Wall Polyethylene (PE) Pipe and for Gravity-Flow Storm Sewer and Subsurface Drainage Applications ASTM F 2389-2010 Pressure-Rated Polypropylene (PP) Piping ASTM F 2434-2009* Metal Insert Utilizing a Copper Crimp Ring for Table 6-4 SDR9 Cross-linked Polyethylene (PEX) Tubing and SDR9 Cross-linked Polyethylene/Aluminum/Cross-linked Polyethylene (PEX-AL-PEX) Tubing ASTM F 2648-2007 CPE Storm Sewer Piping Piping, Plastic 1101.3 ASTM F 2649-2008 HDPE Grease Interceptor Fixtures 1014.1, 1014.3.1 ASTM F 2736-2010 Specification for 6 to 30 in. Polypropylene (PP) Corrugated Piping, Plastic 1101.3 Single Wall Pipe and Double Wall Pipe. ASTM F 2764-2010 Specification for 6 to 30 in. Polypropylene (PP) Triple Wall Piping and, 1106.3 Pipe and for Non-Pressure Sanitary Sewer Applications Plastic AWS A5.8-2004* Filler Metals for Brazing and Braze Welding Joints 1319.2 AWWA C110-2008* Ductile-Iron and Gray-Iron Table 6-4 AWWA C111-2007* Rubber-Gasket Joints for Ductile-Iron Pressure Pipe and Joints 604.1 119

STANDARDS AWWA C151-2009* Ductile-Iron Pipe, Centrifugally Cast Piping, Ferrous Table 6-4 AWWA C153-2006* Ductile-Iron Compact for Water Service Table 6-4 AWWA C203-2008* Coal-Tar Protective Coatings and Linings for Steel Water Miscellaneous 301.1.3, 301.2 Pipelines - Enamel and Tape Hot Applied AWWA C213-2007* Fusion-Bonded Epoxy Coating for the Interior and Exterior Miscellaneous 301.1.3, 301.2 of Steel Water Pipelines AWWA C215-2010* Extruded Polyolefin Coatings for the Exterior of Steel Water Miscellaneous 301.1.3, 301.2 Pipelines AWWA C400-2003* Asbestos-Cement Pressure Pipe, 4 in. through 16 in. (100 Piping, Non-Metallic 604.1 mm through 400 mm) for Water Distribution and Transmission AWWA C500-2009* Metal-Seated Gate Valves for Water Supply Service Valves 301.1.3, 301.2 AWWA C504-2010* Rubber Seated Butterfly Valves, 3 in. (75 mm) through 72 in. (1800 mm) Valves 301.1.3, 301.2 AWWA C507-2005* Ball Valves, 6 in. through 48 in. (150 mm through 1200 mm) Valves 301.1.3, 301.2 AWWA C510-2007* Double Check Valve Backflow Prevention Assembly Backflow Protection Table 6-2 AWWA C511-2007* Reduced-Pressure Principle Backflow Prevention Assembly Backflow Protection Table 6-2 AWWA C606-2006* Grooved and Shouldered Joints Joints 301.1.3, 301.2 AWWA C900-2007* Polyvinyl Chloride (PVC) Pressure Pipe and Fabricated, 4 in. through 12 in. (100 mm through 300 mm), for Water Transmission and Distribution AWWA C901-2008* Polyethylene (PE) Pressure Pipe and Tubing, 1/2 in. (13 mm) through 3 in. (76 mm), for Water Service AWWA C904-2006* Cross-Linked Polyethylene (PEX) Pressure Pipe, 1/2 in. (12 mm) through 3 in. (76 mm), for Water Service AWWA C907-2004* Injection-Molded Polyvinyl Chloride (PVC) Pressure, 4 in. through 12 in. (100 mm through 300 mm), for Water Distribution CISPI 310-2009 Couplings for Use in Connection with Hubless Cast Iron Soil Pipe and for Sanitary and Storm Drain, Waste, and Vent Piping Applications 301.1.3, 301.2 Joints 705.1.8, 705.1.9, 705.2.2 CSA A257-2009 Concrete Pipe and Manhole Sections Piping 301.1.3, 301.2 CSA B45.0-2002 (R2008) General Requirements for Plumbing Fixtures Fixtures 301.1.3, 301.2 CSA B45.3-2002 Porcelain-Enameled Steel Plumbing Fixtures Fixtures CSA B45.5-2002 (R2008) Plastic Plumbing Fixtures Fixtures 301.1.3, 301.2 CSA B45.9-2002 (R2008) Macerating and Related Components DWV Components 301.1.3, 301.2 CSA B45.10-2001 (R2006) Hydromassage Bathtubs Fixtures 301.1.3, 301.2 CSA B45.11-2004 Glass Lavatories Fixtures 301.1.3, 301.2 CSA B64-2007 Backflow Preventers and Vacuum Breakers Backflow Protection 301.1.3, 301.2 CSA B64.1.1-2007 Atmospheric Vacuum Breakers (AVB) Backflow Protection Table 6-2 CSA B64.1.2-2007 Pressure Vacuum Breakers (PVB) Backflow Protection Table 6-2 CSA B64.2-2007 Hose Connection Vacuum Breakers (HCVB) Backflow Protection 301.1.3, 301.2 CSA B64.2.1.1-2007 Hose Connection Dual Check Vacuum Breakers (HCDVB) Backflow Protection Table 6-2 CSA B64.4-2007 Reduced Pressure Principle (RP) Backflow Preventers Backflow Protection Table 6-2 CSA B64.4.1-2007 Reduced Pressure Principle Backflow Preventers for Fire Backflow Protection Table 6-2 Protection (RPF) CSA B64.5-2007 Double Check Valve (DVCA) Backflow Preventers Backflow Protection Table 6-2 CSA B64.5.1-2007 Double Check Valve Backflow Preventers for Fire Protection Backflow Protection Table 6-2 (DVCAF) CSA B64.7-2007 Laboratory Faucet Vacuum Breakers (LFVB) Backflow Protection 301.1.3, 301.2 CSA B79-2008 Commercial and Residential Drains and Cleanouts DWV Components 301.1.3, 301.2 CSA B125.3-2005 Plumbing 412.1, 414.5, 417.3, Table 6-2 120

STANDARDS CSA B128.1-2006/B128.2-2006 Design and Installation of Non-Potable Water /Maintenance and Field Testing of Non-Potable Water Miscellaneous 301.1.3, 301.2 CSA B137.1-2009 Polyethylene (PE) Pipe, Tubing, and for Cold-Water Pressure Services CSA B137.5-2009 Crosslinked Polyethylene (PEX) Tubing for Pressure Applications CSA B137.9-2009 Polyethylene/Aluminum/Polyethylene (PE-AL-PE) Composite Pressure-Pipe CSA B137.10-2009 Crosslinked Polyethylene/Aluminum/Crosslinked Polyethylene (PEX-AL-PEX) Composite Pressure-Pipe CSA B181.3-2006 Polyolefin and Polyvinylidene Fluoride (PVDF) Laboratory Piping, Plastic 301.1.3, 301.2 Drainage CSA B242-2005 Groove- and Shoulder-Type Mechanical Pipe Couplings 301.1.3, 301.2 CSA B356-2010 Water Pressure Reducing Valves for Domestic Water Supply Valves 301.1.3, 301.2 CSA G401-2007 Corrugated Steel Pipe Products Piping, Ferrous 301.1.3, 301.2 CSA LC-3-2000 Appliance Stands and Drain Pans Miscellaneous 301.1.3, 301.2 (R2005)* CSA Z21.10.1a-2009* Gas Water Heaters Volume I, Storage Water Heaters with Fuel Gas, Appliances 301.1.3, 301.2 Input Ratings of 75 000 Btu Per Hour or Less (same as CSA 4.1a) CSA Z21.10.3b-2008 Gas Water Heaters Volume III, Storage Water Heaters with Fuel Gas, Appliances 501.0 Input Ratings Above 75 000 Btu Per Hour, Circulating and Instantaneous (same as CSA 4.3b) CSA Z21.13a-2010* Gas-Fired Low Pressure Steam and Hot Water Boilers (same Fuel Gas, Appliances 301.1.3, 301.2 as CSA 4.9a) CSA Z21.22b-2001 Relief Valves for Hot Water Supply (same as CSA Valves 301.1.3, 301.2 4.4b) CSA Z21.56a-2008* Gas-Fired Pool Heaters (same as CSA 4.7a) Fuel Gas, Swimming USPSHTC Pools, Spas, and Hot Tubs FCI 74-1-1991 Spring Loaded Lift Disc Check Valve Valves 301.1.3 IAPMO IGC 67-2005 Specialized Miscellaneous Plastic DWV and Fitting 401.1 Assemblies IAPMO IGC 111-1999 Movable Sink Fixtures 401.1 IAPMO IGC 154-2009 Tub/Shower Enclosures and Shower Panel Assemblies Fixtures 301.1.3, 301.2 IAPMO IGC 157-2010 Ball Valves Valves 301.1.3, 301.2 IAPMO IGC 161-2002 Non-Flushing Urinals Fixtures 401.1 IAPMO IGC 172-2010 Glass Lavatories, Sinks and Counter Tops Fixtures 301.1.3, 301.2 IAPMO IGC 183-2008 Oil/Water Separators and Condensing Plate Separators Fixtures 1009.1, 1017.1 IAPMO IGC 187-2003 Roof Drains with Integral Overflow Fixtures 1101.3 IAPMO IGC 188-2004 Removable and Non-Removable Push Fit 604.1 IAPMO IGC 193-2010 Safety Plates, Plate Straps, Notched Plates and Safety Collars Miscellaneous 301.1.3, 301.2 IAPMO IGC 194-2004a Copper Alloy or Aluminum Alloy Sinks and Lavatories Fixtures 301.1.3, 301.2 IAPMO IGC 195-2004 Floor Drain with Integrated Bonding Flange Fixtures 401.1 IAPMO IGC 217-2007 Metallic Bathtubs, Shower Pans and Whirlpool Bathtubs Fixtures 301.1.3, 301.2 IAPMO IGC 224-2005 In-Flow Test Tees 701.1 IAPMO IGC 226-2006a Drinking Water Fountains With or Without Chiller or Heater Fixtures 301.1.3, 301.2 IAPMO IGC 237-2006 Coupling for Hubless Cast Iron Pipe Joints 705.1.9 IAPMO IGC 257-2009a Hinge Type Couplings Used For Joining Hubless Cast Iron Joints 705.1.9 Oil Pipe and IAPMO PS 16-2004 Sub Drains for Built-Up Shower Pans Fixtures (R2010)* 121

STANDARDS IAPMO PS 23-2006a Dishwasher Drain Airgaps Backflow Protection 301.1.3, 301.2 IAPMO PS 25-2002 Metallic for Joining Polyethylene Pipe for Water Joints 301.1.3, 301.2 Service and Yard Piping IAPMO PS 34-2003 Encasement Sleeve for Potable Water Pipe and Tubing Piping 301.1.3, 301.2 IAPMO PS 36-1990 Lead Free Sealing Compounds for Threaded Joints Joints 301.1.3, 301.2 IAPMO PS 37-1990 Black Plastic PVC or PE Pressure-Sensitive Corrosion Miscellaneous 301.1.3, 301.2 Preventive Tape IAPMO PS 42-1996 Pipe Alignment & Secondary Support Miscellaneous 301.1.3, 301.2 IAPMO PS 43-2007 Cushioned Bathtubs and Whirlpool Bathtub Appliances Fixtures 301.1.3, 301.2 IAPMO PS 46-2010 Field-Fabricated Tiling Kits Miscellaneous 301.1.3, 301.2 IAPMO PS 50-2010 Flush Valves with Dual Flush Device For Water Closets or Fixtures 301.1.3, 301.2 Water Closet Tank with an Integral Flush Valves with a Dual Flush Device IAPMO PS 51-1998 Plastic and Metallic Expansion Joints Joints 301.1.3, 301.2 IAPMO PS 52-2009 Pump/Dose, Sumps and Sewage Ejector Tanks with or DWV Components 301.1.3, 301.2 without a Pump IAPMO PS 53-2008 Grooved Mechanical Pipe Couplings and Grooved End Joints 301.1.3, 301.2 IAPMO PS 54-2010 Metallic and Plastic Utility Boxes Miscellaneous 301.1.3, 301.2 IAPMO PS 55-1992 Bathwaste Strainer Drains Fixtures 301.1.3, 301.2 IAPMO PS 57-2002 PVC Hydraulically Actuated Diaphragm Type Water Control Valves 301.1.3, 301.2 Valves IAPMO PS 60-1996 Sewage Holding Tank Containing Sewage Ejector Pump for DWV Components 301.1.3, 301.2 Direct Mounted Water Closet IAPMO PS 61-2006a Fabricated Stainless steel Water Closets or Urinals Fixtures 401.1, 402.1, 402.2, 410.0 IAPMO PS 63-2005 Plastic Leaching Chambers DWV Components 301.1.3, 301.2 IAPMO PS 64-2007a Pipe Flashings Miscellaneous 301.1.3, 301.2 IAPMO PS 65-2002 Airgap Units for Water Conditioning Equipment Installation Backflow Protection 611.2 IAPMO PS 66-2000 Dielectric Waterway 301.1.3, 301.2 IAPMO PS 67-2010 Early-Closure Replacement Flappers or Early-Closure Fixtures 301.1.3, 301.2 Replacement Flapper with Mechanical Assemblies IAPMO PS 69-2006 Bathwaste and Overflow Assemblies with Tub Filler Spout DWV Components 301.1.3, 301.2 IAPMO PS 72-2007 Valves with Atmospheric Vacuum Breakers Valves 301.1.3, 301.2 IAPMO PS 73-1993 Dental Vacuum Pumps Miscellaneous 301.1.3, 301.2 IAPMO PS 76-1995 Ballcock or Flushometer Valve Tailpiece Trap Primers and Trap Primer Receptors/Adapters DWV Components 301.1.3, 301.2 IAPMO PS 79-2005 Multiport Electronic Trap Primer DWV Components 301.1.3, 301.2 IAPMO PS 80-2008 Clarifiers DWV Components 301.1.3, 301.2 IAPMO PS 81-2006 Precast Concrete Seepage Pit Liners and Covers DWV Components 301.1.3, 301.2 IAPMO PS 82-1995 Fiberglass (Glass Fiber Reinforced Thermosetting Resin) 301.1.3, 301.2 IAPMO PS 85-1995 Tools for Mechanically Formed Tee Connections in Copper Miscellaneous 301.1.3, 301.2 Tubing IAPMO PS 86-1995 Rainwater Diverter Valve for Non-Roofed Area Slabs DWV Components 301.1.3, 301.2 IAPMO PS 87-1995 Diverter and Shutoff Valves for Pool/Spas Swimming Pools, USPSHTC Spas, and Hot Tubs IAPMO PS 88-2010 Pre-Pressurized Potable Water or Expansion Tanks Miscellaneous 301.1.3, 301.2 IAPMO PS 89-1995 Soaking and Hydrotherapy (Whirlpool) Bathtubs with Fixtures 301.1.3, 301.2 Hydraulic Seatlift IAPMO PS 90-2006 Elastomeric Test Caps/Cleanout Caps DWV Components 301.1.3, 301.2 IAPMO PS 91-2005a Plastic Stabilizers for Use with Plastic Closet Bends DWV Components 301.1.3, 301.2 IAPMO PS 92-2010 Heat Exchangers and Indirect Water Heaters Miscellaneous 301.1.3, 301.2 122

STANDARDS IAPMO PS 93-2004a Water Closets with Spray, Water Closet Seats with Spray and Fixtures 408.2 Other Devices with Spray for Water Closets Supplied with Hot and Cold Water IAPMO PS 94-2008 P-Trap, Supply Stop and Riser Insulated Protector Miscellaneous 301.1.3, 301.2 IAPMO PS 95-2001 Drain, Waste, and Vent Hangers and Plastic Pipe Support Hooks DWV Components 301.1.3, 301.2 IAPMO PS 96-2002 Passive Direct Solar Water Heaters Appliances USEC IAPMO PS 98-1996 Prefabricated Fiberglass Church Baptisteries Fixtures 301.1.3, 301.2 IAPMO PS 99-2007 Terrazzo, Marble, Concrete, Granite, and Slate Plumbing Fixtures 301.1.3, 301.2 Fixtures IAPMO PS 100-1996 Porous Filter Protector for Sub-Drain Weep Holes DWV Components 301.1.3, 301.2 IAPMO PS 101-1997 Suction Relief Valves Valves 301.1.3, 301.2 IAPMO PS 104-1997 Pressure Relief Connection for Dispensing Equipment Valves 301.1.3, 301.2 IAPMO PS 105-1997 Polyethylene Distribution Boxes DWV Components 301.1.3, 301.2 IAPMO PS 106-2010 Pre-Fabricated, Tileable Shower Receptors Fixtures 301.1.3, 301.2 IAPMO PS 110-2006a PVC Cold Water Compression 301.1.3, 301.2 IAPMO PS 111-1999 PVC Cold Water Gripper 301.1.3, 301.2 IAPMO PS 112-1999 PVC Plastic Valves for Cold Water Distribution Valves 301.1.3, 301.2 Outside a Building and CPVC Plastic Valves for Hot and Cold Water Distribution IAPMO PS 113-2010 Hydraulically Powered Household Food Waste Disposers Appliances 301.1.3, 301.2 IAPMO PS 114-1999 e1 Remote Floor Box Industrial Water Supply, Air Supply, Miscellaneous 301.1.3, 301.2 Drainage IAPMO PS 115-2007 Hot Water On-Demand or Automatic Activated Hot Water Miscellaneous 301.1.3, 301.2 Pumping IAPMO PS 116-1999 Hot Water Circulating Devices Which Do Not Use a Pump Miscellaneous 301.1.3, 301.2 IAPMO PS 117-2008 Copper and Copper Alloy Tubing System Incorporating Press-Type or Nail-Type Connections 301.1.3, 301.2 IAPMO PS 119-2006 Water Energized Sump Pump Miscellaneous 301.1.3, 301.2 IAPMO Z124.1.2-2005* Plastic Bathtub and Shower Units Fixtures 301.1.3, 301.2 IAPMO Z124.3-2005* Plastic Lavatories Fixtures 301.1.3, 301.2 IAPMO Z124.4-2006* Plastic Water Closet Bowls and Tanks Fixtures 301.1.3, 301.2 IAPMO Z124.5-2006* Plastic Toilet (Water Closet) Seats Fixtures 301.1.3, 301.2 IAPMO Z124.6-2007 Plastic Sinks Fixtures 301.1.3, 301.2 IAPMO Z124.7-1997* Prefabricated Plastic Spa Shells Fixtures, Swimming Pools, Spas, and Hot 301.1.3, 301.2, USPSHTC Tubs IAPMO Z124.8-1990* Plastic Bathtub Liners Fixtures 301.1.3, 301.2 IAPMO Z124.9-2004* Plastic Urinal Fixtures Fixtures 401.1 ISEA Z358.1-2009* Emergency Eyewash and Shower Equipment Miscellaneous 416.1, 416.2 ISO/IEC Guide 65-1996 General Requirements for Bodies Operating Product Certification Certification 301.1.3, 301.2 MSS SP-25-2008* Marking for Valves,, Flanges, and Unions Miscellaneous 301.1.3, 301.2 MSS SP-42-2009* Corrosion Resistant Gate, Globe, Angle and Check Valves Piping, Ferrous 301.1.3, 301.2 with Flanged and Butt Weld Ends (Classes 150, 300 & 600) MSS SP-44-2010* Steel Pipeline Flanges 301.1.3, 301.2 MSS SP-58-2009 Pipe Hangers and Supports Materials, Design, Manufacture, Fuel Gas 1318.7 Selection, Application, and Installation MSS SP-67-2002a* Butterfly Valves Valves 301.1.3, 301.2 MSS SP-69-2003* Pipe Hangers and Supports -Selection and Application Miscellaneous 1318.7 MSS SP-70-2006* Gray Iron Gate Valves Flanged and Threaded Ends Valves 301.1.3, 301.2 123

STANDARDS MSS SP-71-2011* Gray Iron Swing Check Valves, Flanged and Threaded Ends Valves 301.1.3, 301.2 MSS SP-72-2010* Ball Valves with Flanged or Butt-Welding Ends for General Valves 301.1.3, 301.2 Service MSS SP-78-2005a* Gray Iron Plug Valves Flanged and Threaded Ends Valves 301.1.3, 301.2 MSS SP-80-2008* Bronze Gate, Globe, Angle, and Check Valves Valves 301.1.3, 301.2 MSS SP-83-2006* Class 3000 Steel Pipe Unions Socket Welding and Threaded Joints 301.1.3, 301.2 MSS SP-89-2003* Pipe Hangers and Supports-Fabrication and Installation Practices Miscellaneous 301.1.3, 301.2 MSS SP-104-2003* Wrought Copper Solder Joint Pressure 301.1.3, 301.2 MSS SP-106-2003* Cast Copper Alloy Flanges and Flanged : Class 125, 301.1.3, 301.2 150 and 300 MSS SP-109-1997 Welded Fabricated Copper Solder Joint Pressure 301.1.3, 301.2 (R2006)* MSS SP-123-1998 (R2006)* Non-Ferrous Threaded and Solder Joint Unions for Use with Copper Water Tube Joints 301.1.3, 301.2 NFPA 99c-2012* Gas and Vacuum Piping 301.1.3, 301.2 NSF 2-2010* Food Equipment Appliances 301.1.3, 301.2 NSF 3-2009* Commercial Warewashing Equipment Appliances 301.1.3, 301.2 NSF 4-2009* Commercial Cooking, Rethermalization, and Powered Hot Appliances 301.1.3, 301.2 Food Holding and Transport Equipment NSF 5-2009* Water Heaters, Hot Water Supply Boilers, and Heat Recovery Appliances 301.1.3, 301.2 Equipment NSF 12-2009* Automatic Ice Making Equipment Appliances 301.1.3, 301.2 NSF 14-2010* Plastics Piping System Components and Related Materials Piping, Plastic 301.1, 611.3 NSF 18-2009* Manual Food and Beverage Dispensing Equipment Appliances 301.1.3, 301.2 NSF 29-2009* Detergent and Chemical Feeders for Commercial Spray-Type Appliances 301.1.3, 301.2 Dishwashing Machines NSF 40-2009* Residential Wastewater Treatment DWV Components 301.1.3, 301.2 NSF 41-2005* Non-Liquid Saturated Treatment DWV Components 301.1.3, 301.2 NSF 42-2009* Drinking Water Treatment Units Aesthetic Effects Appliances 611.3 NSF 44-2009* Residential Cation Exchange Water Softeners Appliances 611.3 NSF 46-2010* Evaluation of Components and Devices Used in Wastewater DWV Components 301.1.3, 301.2 Treatment NSF 53-2009e* Drinking Water Treatment Units Health Effects Appliances 611.3, L 504.2.1 NSF 55-2009* Ultraviolet Microbiological Water Treatment Appliances 611.3 NSF 58-2009* Reverse Osmosis Drinking Water Treatment Appliances 611.2, 611.3 NSF 61-2010a* Drinking Water System Components Health Effects Water Supply Components 604.1, 605.1, 608.2 NSF 61 G Drinking Water System Components Health Effects Water Supply Components 606.1, 608.2 604.1, 604.10, 605.1, NSF 62-2009* Drinking Water Distillation Appliances 611.3 NSF 169-2009* Special Purpose Food Equipment and Devices Appliances 301.1.3, 301.2 NSF 372 Drinking Water System Components Health Effects Water Supply Components 606.1, 608.2 604.1, 604.10, 605.1, PDI G-101-2010 Testing and Rating Procedure for Hydro Mechanical Grease DWV Components 301.1.3, 301.2 Interceptors with Appendix of Installation and Maintenance PDI-WH 201-2010 Water Hammer Arresters Water Supply Components 301.1.3, 301.2 SAE J512-1997 Automotive Tube 301.1.3, 301.2 SAE J1670-2008 Type F Clamps for Plumbing Applications Joints 301.1.3, 301.2 124

STANDARDS SRCC Standard OG100- Solar Domestic Hot Water System and Component Test Solar Panels 2006 Protocols SRCC Standard OG300-2008 Operating Guidelines and Minimum Standards for Certifying Solar Water Heating Solar Water Heating TCNA A118.10-2011* Load Bearing, Bonded, Waterproof Membranes for Thin-Set Miscellaneous 301.1.3, 301.2 Ceramic Tile and Dimension Stone Installation TCNA A137.1-2008* Specifications for Ceramic Tile Miscellaneous 301.1.3, 301.2 UL 174-2004* Household Electric Storage Tank Water Heaters (with revisions Appliances 301.1.3, 301.2 through April 22, 2009) UL 207-1993 Refrigerant Components and Accessories, Non-Electrical Fitting 604.1, 701.2 UL 399-2008* Drinking Water Coolers (with revisions through December Appliances 301.1.3, 301.2 15, 2009) UL 429-2009 Electrically Operated Valves (with revisions through January Valves 301.1.3, 301.2 6, 2010) UL 430-2009* Waste Disposers Appliances 301.1.3, 301.2 UL 499-2005* Electric Heating Appliances (with revisions through Appliances 301.1.3, 301.2 November 30, 2010) UL 563-2009* Ice Makers (with revisions through November 19, 2009) Appliances 301.1.3, 301.2 UL 723-2008* Test for Surface Burning Characteristics of Building Materials (with revisions through September 13, 2010) Miscellaneous 1101.3 701.1(2), 903.1(2), UL 726-1995 Oil-Fired Boiler Assemblies (with revisions through April 22, 2010) Fuel Gas, Appliances 301.1.3, 301.2 UL 732-1995* Oil-Fired Storage Tank Water Heaters (with revisions through Fuel Gas, Appliances 301.1.3, 301.2 April 22, 2010) UL 749-2008 Household Dishwashers Appliances 301.1.3, 301.2 UL 778-2010* Motor-Operated Water Pumps (with revisions through August Appliances 301.1.3, 301.2 25, 2011) UL 834-2004* Heating, Water Supply, and Power Boilers Electric (with Appliances 301.1.3, 301.2 revisions through December 4, 2009) UL 921-2006* Commercial Dishwashers (with revisions through June 23, Appliances 301.1.3, 301.2 2010) UL 1206-2003* Electric Commercial Clothes-Washing Equipment (with revisions through June 16, 2010) Appliances 301.1.3, 301.2 UL 1261-2001* Electric Water Heaters for Pools and Tubs (with revisions through June 16, 2010) UL 1331-2005 Station Inlets and Outlets (with revisions through August 18, 2010) UL 1453-2004* Electric Booster and Commercial Storage Tank Water Heaters (with revisions through December 4, 2009) UL 1469-2006 Strength of Body and Hydraulic Pressure Loss Testing of Backflow Special Check Valves (with revisions through March 19, 2010) UL 1479-2003* Fire Tests of Through-Penetration Firestops (with revisions through March 1, 2010) UL 1951-1994* Electric Plumbing Accessories (with revisions through June 25, 2010) UL 2157-1997* Electrical Clothes Washing Machines and Extractors (with revisions through February 16, 2010) WQA S-300-2000 Point-of-Use Low Pressure Reverse Osmosis Drinking Water *ANSI designated as an American National Standard. Appliances, Swimming Pools, Spas, and Hot Tubs 301.1.3, 301.2, USPSHTC Medical Gas 301.1.3, 301.2 Appliances 301.1.3, 301.2 Backflow Protection 301.1.3, 301.2 Miscellaneous 1505.3, 1506.3 Miscellaneous 301.1.3, 301.2 Appliances 301.1.3, 301.2 Appliances 301.1.3, 301.2 125

STANDARDS ABBREVIATIONS IN TABLE 14-1 AHAM Association of Home Appliance Manufacturers, 1111 19th Street, N.W., Suite 402, Washington DC 20036. ANSI American National Standards Institute, Inc., 25 W. 43rd Street, 4th Floor, New York, NY 10036. ASME American Society of Mechanical Engineers, Three Park Avenue, New York, NY 10016-5990. ASSE American Society of Sanitary Engineering, 901 Canterbury, Suite A, Westlake, Ohio 44145. ASTM American Society for Testing and Materials, 100 Barr Harbor Drive, West Conshohocken, PA 19428-2959. AWS American Welding Society, 550 NW LeJeune Road, Miami, FL 33126. AWWA American Water Works Association, 6666 W. Quincy Avenue, Denver, CO 80235. CISPI Cast-Iron Soil Pipe Institute, 5959 Shallowford Road, Suite 419, Chattanooga, TN 37421. CSA Canadian Standards Association, 5060 Spectrum Way, Suite 100, Mississauga, Ontario, Canada, L4W 5N6. e1 An editorial change since the last revision or reapproval. IAPMO International Association of Plumbing and Mechanical Officials, 5001 E. Philadelphia Street, Ontario, CA 91761. ISEA International Safety Equipment Association, 1901 N. Moore Street, Arlington, VA 22209-1762. ISO International Organization for Standardization, 1 ch. de la Voie-Creuse, Casa Postale 56, CH-1211 Geneva 20, Switzerland. MSS Manufacturers Standardization Society of the Valve and Industry, 127 Park Street, N.E., Vienna, VA 22180. NFPA National Fire Protection Association, 1 Batterymarch Park, P.O. Box 9101, Quincy, MA 02169-7471. NSF NSF International, 789 Dixboro Road, Ann Arbor, MI 48113-0140. PDI Plumbing and Drainage Institute, 800 Turnpike Street, Suite 300, North Andover, MA 01845. SAE Society of Automotive Engineers, 400 Commonwealth Drive, Warrendale, PA 15096. TCNA Tile Council of North America, Inc. 100 Clemson Research Blvd., Anderson, SC 29625. UMC Uniform Mechanical Code (published by IAPMO). USEC Uniform Solar Energy Code (published by IAPMO). USPSHTC Uniform Swimming Pool, Spa and Hot Tub Code (published by IAPMO). UL Underwriters Laboratories, Inc., 333 Pfingsten Road, Northbrook, IL 60062. WQA Water Quality Association, 4151 Naperville Road, Lisle, IL 60532-3696. 126