Performance of the Monitoring Light Source for the CMS Lead Tungstate Crystal Calorimeter

Similar documents
Maintenance and Operation for ECAL Monitoring (WBS4.3)

2008 JINST 3 S The CMS experiment at the CERN LHC THE CERN LARGE HADRON COLLIDER: ACCELERATOR AND EXPERIMENTS.

Recent Advances in Solid State Lasers and Nonlinear Optics for Remote Sensing

AIDA Advanced European Infrastructures for Detectors at Accelerators. Presentation. LumiCal alignment system, status report

A Beam radiation monitor for the SVT based on CVD diamond sensors!

Information for Proper Posting & Laser Area Sign Templates

Compact Muon Solenoid Detector (CMS) & The Token Bit Manager (TBM) Alex Armstrong & Wyatt Behn Mentor: Dr. Andrew Ivanov

The Compact Muon Solenoid Experiment. Conference Report. Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland. Status of CMS Commissioning

Aging Analysis of Micromegas Detectors for ATLAS New Small Wheel

The LHCb Outer Tracker: Production & Ageing studies

Laser Safety Program ELI-NP

UC INSTRUMENTS GM8036 LASER SWEEP OPTICAL SPECTRUM ANALYZER (1525 ~ 1610 nm) Technical Specifications v1.01 March, 2011

Beam Loss Position Monitoring with Optical Fibres at DELTA

The Compact Muon Solenoid Experiment. Conference Report. Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland

ATLAS Diamond Beam Conditions Monitor

Quality Assurance and Quality Control of Optical Fibres for CERN

arxiv: v1 [physics.ins-det] 2 Oct 2013

The FEL Facility Optical Diagnostics and FEL Characterization

Copyright 2017 by Lasermate Group, Inc.. All rights reserved.

CALIBRATION HOW IT WORKS

PoS(ICHEP2012)516. The status of the CMS pixel upgrade detector

EEM 451 Industrial Control Systems Sensors and Actuators-II. Dept. of Electrical-Electronics Eng. Anadolu University, Turkey

arxiv: v1 [physics.ins-det] 20 Mar 2017

Diamond as potential CryoBLM for the LHC All results are preliminary

Tracking Detectors 2 silicon for HEP

Identify the key elements of the laser source, regardless of the type of measurement or sensor required;

R&D Fast and lightweight EIC integrated tracking system Barrel MicroMegas & Forward Triple-GEM

760nm Single mode VCSEL with Peltier Element and Thermistor in TO510

ATLAS Beam Abort System Using CVD Diamond Sensors

US CMS Trigger. DOE-NSF Review Wesley H. Smith, U. Wisconsin CMS Trigger Project Manager April 9, 2003

clear & preserve vision OptoYag&SLT

Link loss measurement uncertainties: OTDR vs. light source power meter By EXFO s Systems Engineering and Research Team

GEM detectors activity at the Laboratori Nazionali di Frascati of INFN

TRULY HAND-HELD gamma-ray detectors with excellent

February 12, PHY357 Lecture 11. Experimental Methods. Accelerators. Particle Interactions. Particle Detectors. Full experiment (eg.

STATUS OF THE LHC EXPERIMENTS.

CALICE: status of a data acquisition system for the ILC calorimeters. Valeria Bartsch, on behalf of CALICE-UK Collaboration

Detectors Plans for LS1

Micromegas detectors for the upgrade of the ATLAS Muon Spectrometer

Data acquisition for the ILC

FS-200. Model. Instruction Manual. Infrared Food Thermometer. reedinstruments. www. com

Hazard Analysis, Mitigation, and Operating Procedures for (Laser name) Laser

RECENT DEVELOPMENTS ON MICRO-PATTERN GASEOUS DETECTORS TECHNOLOGY

WHAT IS LASER ULTRASONIC TESTING?

Recent Advances in Large Area Micro-channel Plates and LAPPD TM

The Optical Scattering Calibration System at SNO+ IOP 2015

Chemistry Instrumental Analysis Lecture 4. Chem 4631

MD456: Monitoring of abort gap population with diamond particle detectors at the BGI in IP 4

Laser Damage Measurements

Measurement of light scattering in deep sea

Omnisens DITEST TM FIBER OPTIC DISTRIBUTED TEMPERATURE & STRAIN SENSING TECHNIQUE

CALIBRATION HOW IT WORKS

OptoYag M. clear vision

Temperature dependent Components within the Pyroelectric Detector

SPECTRAL INSTRUMENTATION

ND280 Construction Status Report

A. Administrative. B. Labeling and Posting. C. Control Measures. Laser Safety Self-Audit Checklist. Building Room Principal Investigator Date

OptoSLT M. preserve vision

High-Power Q-Switched Diode-Pumped UV Laser Q-Series, Q305

LM-80V , h V LM-30V h V

Performance of a New Type of Electrical Cooler for HPGe Detector Systems

Development of a variable output LED-365 irradiance standard

THE NEXT GENERATION IN VISIBILITY SENSORS OUTPERFORM BOTH TRADITIONAL TRANSMISSOMETERS AND FORWARD SCATTER SENSORS

UC IRVINE LASER SAFETY NEWSLETTER

Date: Wednesday, January 31, 2018 Time: 8:30 am 5:00 pm Location: Moscone West (Room 2018, Level 2)

Commissioning of the ASTA Photoinjector Laser System

Laser Specifications and Characteristics:

DWDM OTDR with Tunable Laser MTP-200-D100. Hand-held High Performance OTDR. Series

CALIFORNIA INSTITUTE OF TECHNOLOGY LASER SAFETY MANUAL. January, 1998

CMS, In Brief. Bill Gabella Vanderbilt Quarknet session, July 20, 2015 (disgracefully borrowing from Will Johns)

Health Monitoring System Using FBG-Based Sensors for a 12-Story Building with Column Dampers.

Performance Requirements for Monitoring Pulsed, Mixed Radiation Fields Around High-Energy Accelerators

2 Ensure that all personnel in the area are wearing the appropriate protective eyewear.

CALIBRATION HOW IT WORKS

Development of a new X-ray source system using ultraviolet laser for medical treatment

16S-Series 150W. In Vivo SPF Sunscreen Testing Solar Simulator

Drift Chamber construction for ATLAS*

Aging measurements on triple-gem detectors operated with CF 4 based gas mixtures

An FT-NIR Primer. NR800-A-006

Status Report about the TPC Detector and Module at CEPC

Laser Safety Self-Audit Checklist

CCD-Precision. Intelligent Laser-Optical Displacement Measurement. CCD System. SENSORS & SYSTEMS Authority in Displacement Measurement ILD 1800

Status of the LHCb Detector. LHCC Open Session CERN, 27 November 2002 Werner Witzeling on behalf of the LHCb Collaboration

Establishing a Center of Excellence for. Security Science and Engineering

Commissioning of the Silicon Drift Detector of the ALICE experiment at the LHC

Aging Tests of of Full Scale CMS Cathode Strip Muon Chambers

Stato di LHCb. P. Campana CSN1 14 maggio Il Trigger L0 dei Calorimetri Il sistema dei RICH Il sistema a Muoni

The distributed particle detectors and data acquisition modules for Extensive Air Shower measurements at "HT-KZ" experiment

mach 5 100kHz Digital Joulemeter: M5-SJ, M5-IJ and M5-PJ Joulemeter Probes

The ATLAS detector: status of the construction and installation a year before the first p-p collisions at the LHC Collider

Laser Scan Micrometer Page 418. Laser Scan Micrometer Page 423

System Test of the ATLAS Muon Spectrometer in the H8 Beam at the CERN SPS

Customized MCPs for Analytical Instruments. An MCP for every application

CCD-Precision. Intelligent Laser-Optical Displacement Measurement. CCD System SENSORS & SYSTEMS. Authority in Displacement Measurement ILD 1800

Gaseous detectors. 1

Humidity sensors. Behavior in different environments. Supervisor: Vaclav Vacek Collaborators: Martin Doubek, Martin Janda and Michal Vitek 28.9.

HiRadMat facility at the CERN SPS

Publication American Institute of Physics. Reprinted with permission.

Interferometric optical time-domain reflectometry for distributed optical-fiber sensing

University of California Santa Barbara Department of Chemistry and Biochemistry Optical Characterization Facility. Safe operations manual

Transcription:

Performance of the Monitoring Light Source for the CMS Lead Tungstate Crystal Calorimeter L. Zhang, D. Bailleux, A. Bornheim, K. Zhu, R.-Y. Zhu California Institute of Technology 1

Introduction A high resolution PWO crystal calorimeter is under construction by the CMS collaboration for LHC. The mass produced PWO crystals are radiation hard to high integrated dosage, but still suffer from a dose rate dependent damage as shown in induced absorption. Measuring variations of crystal transmittance and providing corrections of crystal light output, a light monitoring system plays a crucial role in maintaining PWO calorimeter energy resolution. A laser based light source and high level distribution system was designed and constructed at Caltech, and was installed and commissioned at CERN in the last three years. Performance and stability of this system in beam test is reported. 2

Expected PWO ECAL Resolution See also talk N6-1, W. Funk Beam Test Radiation Damage? Crystal Calorimetry at very High Energies Designed Resolution 3

PWO Radiation Damage Damage and recovery: color center formation Dose rate dependent: cc creation and annihilation 4

Monitoring Wavelength Determination IEEE Tran. Nucl. Sci. V 48 (2001) 372 (T) versus (LY) Sensitivity and Linearity 440 nm is chosen for the best linearity 5

Continuous Monitoring in situ Using 1% beam gaps in thelhc beam structure Rate limited by DAQ at 100 Hz 6

ECAL Light Monitoring System APD/PD monitors the PWO crystals. LSDS 4 The ECAL light monitoring system consists of laser source, optical switch based high-level distribution system and two level fanout system. 7

Laser Source Requirements Pulse width: FWHM <40ns to match PWO readout. Pulse jitter: <4ns/<2ns for long/short term. Pulse energy: 0.4 mj/pulse to provide more than 100 GeV equivalent energy deposition in each crystal. Pulse energy instability: <10%. Pulse rate: 100Hz, the maximum rate allowed by DAQ. 8

Lasers and High-level Distribution System 2003 2001 2004 The 1 st laser system was Installed in 2001, and used in 2002 beam test. 2001 The 2 nd and 3 rd laser systems installed at CERN in August, 2003. 9

Ti:Sapphire Laser with Two Wavelengths Nd:YLF Pump Tunable Ti:S 10

Laser Monitors, DAQ and Distribution System 11

Lasers Ready for 2004 Test Beam DSO based slow monitor An Acqiris DP210 card of 2 GS/s was installed in 2004 to provide pulse energy and FWHM information for each laser pulse. 440 nm Time (hours) 12

Laser Performance in 2003 Beam Test Typical stable operation during 2003 beam test at CERN : External Trigger (=Laser Runs) For blue laser (runs at higher pump current) : Mean degradation : 0.41%/day - 12.4%/month Energy Scan Laser Source Internal Trigger For red laser : Mean degradation : 0.057%/day - 1.72%/month 440 nm 495 nm air conditioning unstable 800 nm 700 nm Time [hours] In total more than 1200 hours of operation in 2003 beam test 13

Pulse Energy Stability t ref : 330-355 h 2.6 % 7.6 % Stability over 25 h 440 nm 495 nm Very good performance exceeds requirements! 3.2 % 800 nm 8.2 % 700 nm Typical Laser Run in test beam mode takes 10-30 minutes. 1.5 % t ref : 200-200.5 h 2.8 % 440 nm 800 nm 14

Pulse Width and Timing Jitter Stability Stability over 25 h 2.7 % 25.7 ns t ref : 330-355 h 6.8 % 440 nm 65.8 ns 495 nm Very good performance. In general 440nm/800nm better than 495nm/700nm. 2.6 % 5.7 % 23.9 ns 800 nm 36.3 ns 700 nm pulse width [ns] Pulse timing jitter is anticorrelated to the pulse energy variations! 2.8 ns 1.5 ns 440 nm 800 nm pulse time [ns] 15

Laser Monitoring Application Tracking damage and recovery with laser light 16

Summary A laser based monitoring light source for CMS PWO crystal calorimeter was designed and constructed at Caltech, and installed and commissioned at CERN. An Acqiris DP210 card of 2 GS/s was added in 2004 to provide pulse energy and FWHM information for each pulse. The system performance at 440 and 800 nm reached or exceeded the original design specifications. Detailed studies are underway to understand the ultimate performance of the CMS ECAL monitoring and systematic effects. 17

PWO Resolution With Light Monitoring Nucl.Instr.Meth. A 412 (1998) 223 Before/after beam irradiation: 10% variation in light output 18