COOLING / HEATING COILS

Similar documents
Daikin Water Cooling, Heating, and High Capacity Booster Coils

Daikin Direct Expansion (DX) Cooling Coils

Installation, Operation and Maintenance Guide. Steam Coil Installation, Operation and Maintenance. steam coils

1.1 This section applies to air handling units for HVAC Systems.

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD

INSTALLATION INSTRUCTIONS TXV Horizontal Slab Coils WLSH

Air-Cooling Evaporators

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

Air-Handling System Cooling Options

COMMERCIAL HVAC EQUIPMENT Coils: Direct Expansion, Chilled Water, and Heating

INSTALLATION INSTRUCTIONS

Technical Development Program

G Series. G Series Air Coils Installation ti Manual ENCASED/UNCASED AIR COILS. Geothermal/Water Source Heat Pumps R-410A Refrigerant 2-5 Ton

VENTS. Main Steam Vents. How to Select Steam Vents. For Steam Vent selection information, please refer to Selection Guidelines on page 133.

A. Section includes Factory Packaged, Modular units, providing cooling and heating for air distribution systems.

When You Need a Replacement Coil, Precision Matters.

Service Step by Step Trouble-Shooting Check-List

Indholdsfortegnelse. Danvent Air Handling Units SERVICE MANUAL

FLUID COIL INSTALLATION OPERATION AND MAINTENANCE

CROWN. Boiler Co. Santa-Fe Series. Hydronic Air Handlers INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

Cased Aluminum Coils "Dedicated Upflow / Downflow" Convertible to horizontal with separately purchased kit

RCM Refrigerant Module

Commercial Refrigeration

R Series Cooling Modules

AIR CONDITIONING. Carrier Corporation 2002 Cat. No

Energy-Saving Industrial Water Chillers

User and Installation Instructions C6R/75, C6R/100, C6R/105, C6R/125, C6R/130, D6R/100, D6R/125, D5R/100, D5R/125, D3R/100

Greenheck Coils A Complete Line of Custom Coils to Meet Your Needs. 3/8, 1/2 and 5/8 inch OD Tubing

Greenheck Coils A Complete Line of Custom Coils to Meet Your Needs. 5/16, 3/8, 1/2, 5/8 and 1 inch OD Tubing

Main Steam Vents. Hoffman Specialty Regulators. How to Select Steam Vents

R Series Cooling Modules

Greenheck Coils. A Complete Line of Custom Coils to Meet Your Needs. 3/8, 1/2 and 5/8 inch OD Tubing

Air-Handling System Cooling Options

PAC, NQAC, HQAC, SQAC, EQAC AIR-COOLED CONDENSERS OPERATING AND INSTALLATION INSTRUCTIONS

COMMON WATERSIDE ECONOMIZER APPLICATIONS:

Installation and Testing of Inverted Bucket Steam Traps Manual

INSTALLATION, OPERATION AND MAINTENANCE MANUAL FOR MODEL RH REMOTE HORIZONTAL AIR COOLED HEAT EXCHANGERS

A hydronic system controls comfort by delivering heated or cooled fluid to the conditioned space through pipes.

SECTION AIR COILS

Copyright 2003 and 2005 by The American Institute of Architects (AIA) Modified by MSU Physical Plant / Engineering and Architectural Services

KR Series Air Defrost Unit Coolers Operating and Installation Manual

Installation, Operation, and Maintenance Information

Technical Guide DESCRIPTION CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) FEATURES XTG-A-0307

CS 2. Central Station Air Handlers Double Wall & Single Wall Installation, Operation & Maintenance Manual. Form No. 6120A

INSTALLATION INSTRUCTIONS

HRV-IP. Ceiling Type Heat Pump Heat Recovery Unit

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

SECTION REFRIGERATION EQUIPMENT. A. Section Includes: Refrigeration equipment for insulated cold storage rooms including necessary accessories.

Installation Manual for. Series HWM and Non-ETI HYDRONIC WATER MODULE with SC and SD COMPRESSOR UNITS and R-410 REFRIGERANT

Installation, Operation, and Maintenance Information

RCTA Horizontal Evaporator Coil Installation Instructions

Installation Instructions

Installation Manual for CCS Cased Coils with SC, SD, SW Compressor Units and R-410A Refrigerant

KR Electrical Defrost Unit Coolers (PN E108318_E)

Steam System Best Practices Document No. 11

Installation Instructions

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ)

2/4TXCC037BC3HCA 2/4TXCB042BC3HCA 4TXCC044BC3HCA 2/4TXCC043BC3HCA 2/4TXCB048BC3HCA

CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L2EU NOMINAL TONS

INSTALLATION INSTRUCTIONS

COMMERCIAL REFRIGERATOR AND FREEZER USER S MANUAL

INSTALLATION INSTRUCTIONS TXV Coils for Manufactured Housing EMA

Installation Manual for ETI AVS Series and NON-ETI Air Handlers with SC or SD Compressor Units and R-410A Refrigerant

Installation, Operation, and Maintenance

INSTALLATION INSTRUCTIONS TXV Coils EDM, EDD, EDA

Series 1140 and 1141 Temperature Regulators

HVAC Service Technicians Training Center

The Evolution of the Brewery Chiller System. A 20 year retrospective

40 RM/RMS Packaged Air-Handling Units

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

EL SERIES INSTALLATION INSTRUCTIONS

EarthLinked SC Series Compressor Unit R-407C Quik-Start Instructions

EQUIPMENT CARE AND CLEANING


STC Series Twin Unit Coolers (E329630_A)

CoIL HEAT EXCHAngERS FOR AIR HEATING AND COOLING EnERgy EFFICIEnT SoLUTIonS

Pump & Trap Combinations

INSTALLATION MANUAL G*FD SERIES FULL-CASED A COILS UPFLOW/COUNTERFLOW/HORIZONTAL COOLING/HEAT PUMP

WMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

EarthLinked SW Series Compressor Unit R-410A Quik-Start Instructions

SCE170 SERVICE PARTS

HEAT PIPES DEHUMIDIFICATION &

LONGONI ENGINEERING SRL

Mortex INSTALLATION INSTRUCTIONS AIR CONDITIONING & HEAT PUMP INDOOR COILS

WineZone Ceiling Mount Ductless Split 15

HEATING & COOLING COIL PRODUCTS

Ratio Architects, Inc. Section Refrigerant Piping

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED

Technical Bulletin TB-009

ORTEC HIGH CAPACITY REFRIGERATED AIR/GAS DRYERS

The. Steam ONE-PIPE STEAM SYSTEMS

Installation Instructions

Application of a hybrid control of expansion valves to a 3-ton large room cooling system

DESIGN STANDARDS SECTION 15600

FEATURES AND BENEFITS

user s information manual

R Series Cooling Manual

Transcription:

COOLING / HEATING COILS GENERAL INSTALLATION OPERATION AND MAINTENANCE COIL TYPES CHILLED WATER / GLYCOL HOT WATER / GLYCOL DIRECT EXPANSION (EVAPORATIVE COOLING) STEAM DISTRIBUTING STANDARD STEAM

Type WC - CHILLED WATER / GLYCOL Type WC - HOT WATER / GLYCOL Type Z, A - HOT WATER / GLYCOL 1) Water coils should be mounted level to insure complete drain ability. The headers should be in the vertical position with the tubes in the horizontal position for a horizontal airflow application. a. Vertical airflow applications are available. The circuit arrangement of the coil must be altered from the standard horizontal airflow coil. This must be specified when the coil is ordered. 3) Water coils should be installed with counter flow air and water for maximum heat transfer. This means the entering water will enter the coil on the leaving airside of the coil, then traveling through the coil opposite of the airflow. 4) Water supply connection at the bottom on the leaving airside. The drain will be located at the bottom of this header (lowest point of circuit for draining). 5) Water return connection at the top on the entering airside. The vent will be located at the top of this header (highest point of circuit for venting). 6) All field piping must be self-supporting. System piping should be flexible enough to 7) Once the coil is installed and piped, pressurize with dry nitrogen or other suitable gas

Type DX - DIRECT EXPANSION (EVAPORATIVE COOLING) 1) DX coils should be mounted level to insure proper oil return. The headers should be in the vertical position with the tubes in the horizontal position for a horizontal airflow application. a. Vertical airflow applications are available. The circuit arrangement of the coil must be altered from the standard horizontal airflow coil. This must be specified when the coil is ordered. 3) DX coils should be installed with counter flow air and refrigerant for maximum heat transfer. This means the entering liquid refrigerant will enter the coil on the leaving airside of the coil, then traveling through the coil opposite of the airflow. 4) DX coils are supplied with refrigerant distributors on the leaving airside. The Thermal Expansion Valve (TXV) mounts to the distributor. The liquid refrigerant is then supplied to the TXV. 5) The refrigerant return (suction line) will be the header on the entering airside. 6) If you have a multi circuit coil (more than one distributor and suction). They will be numbered for piping inlet and outlet. 7) All field piping must be self-supporting. System piping should be flexible enough to 8) Once the coil is installed and piped, pressurize with dry nitrogen or other suitable gas

Type NS, NO, NOD - STEAM DISTRIBUTING 1) Steam distributing coils should always be mounted with tubes pitched toward the return end to insure proper condensate removal. The headers should be in the vertical position with the tubes in the horizontal position for a horizontal airflow application. These coils can be built with the tubes pitched in the casing or not pitched in the casing. Check the casing on the coil for pitched tubes. If the coil has the tubes pitched in the case, mount the coil level. a. Vertical airflow applications are available. The tube pitch and return connection location must be altered from the standard horizontal airflow coil. This must be specified when the coil is ordered. b. Vertical tube applications are available. The tubes are not pitched and steam will be supplied at the top and condensate out the bottom. This must be specified when the coil is ordered. 3) This type coil can be used for all air temperatures. It has the tube within a tube design to provide the most uniform leaving air temperatures. 4) If the air temperature is below freezing maintain a minimum 5-psig steam and do not modulate the steam. Normal usage of this coil is in low-pressure steam systems 5 to 15 psig. 100-psig-steam pressure max. 5) Never operate any steam coil below 2-psig-steam. 6) The supply connection is normally in the center of the coil. It is recommended that each supply have it s own supply valve. 7) The return connection is always at the bottom of the coil. It is recommended that each return have it s own trap. 8) All field piping must be self-supporting. System piping should be flexible enough to 9) Once the coil is installed and piped, pressurize with dry nitrogen or other suitable gas

Type SS STANDARD STEAM SAME END CONNECTIONS 1) Same end connection Standard Steam coils should always be mounted level to insure that no condensate is trapped causing water hammer. The headers should be in the vertical position with the tubes in the horizontal position for a horizontal airflow application. a. Vertical airflow applications are available. The coil is the same as the horizontal airflow and must be mounted level. b. Vertical tube applications are not available. 3) Normally used on indoor return air systems with temperatures above freezing. 4) Normal usage of this coil is in low-pressure steam systems 5 to 15 psig. 50-psig-steam pressure max. 5) This coil is not designed for use with a modulating steam valve to fluctuate capacities. 6) Never operate any steam coil below 2-psig-steam. 7) The supply connection is normally in the center of the coil. It is recommended that each supply have it s own supply valve. 8) The return connection is always at the bottom of the coil. It is recommended that each return have it s own trap. 9) All field piping must be self-supporting. System piping should be flexible enough to 10) Once the coil is installed and piped, pressurize with dry nitrogen or other suitable gas

Type SS STANDARD STEAM OPPOSITE END CONNECTIONS 1) Opposite end connection Standard Steam coils should always be mounted with tubes pitched toward the return end to insure proper condensate removal. The headers should be in the vertical position with the tubes in the horizontal position for a horizontal airflow application. These coils can be built with the tubes pitched in the casing or not pitched in the casing. Check the casing on the coil for pitched tubes. If the coil has the tubes pitched in the case, mount the coil level. a. Vertical airflow applications are available. The tube pitch and return connection location must be altered from the standard horizontal airflow coil. This must be specified when the coil is ordered. b. Vertical tube applications are available. The tubes are not pitched and steam will be supplied at the top and condensate out the bottom. 3) Normally used on indoor return air systems with temperatures above freezing. 4) Normal usage of this coil is in low-pressure steam systems 5 to 15 psig. 100-psig-steam pressure max. 5) This coil is not designed for use with a modulating steam valve to fluctuate capacities. 6) Never operate any steam coil below 2-psig-steam. 7) The supply connection is normally in the center of the coil. It is recommended that each supply have it s own supply valve. 8) The return connection is always at the bottom of the coil. It is recommended that each return have it s own trap. 9) All field piping must be self-supporting. System piping should be flexible enough to 10) Once the coil is installed and piped, pressurize with dry nitrogen or other suitable gas

MAINTENANCE If the coil is to deliver its full capacity, both its internal and its external surfaces must be clean. The tubes generally stay clean in pressurized water systems. Should large amounts of scale from when untreated water is used as coolant, chemical or mechanical cleaning of the internal surfaces at frequent intervals is necessary. Water coils should be completely drained if freezing conditions are possible. When coils use evaporating refrigerants, oil accumulation is possible, and occasional checking and oil drainage is desirable. While outer tube surfaces can be cleaned in a number of ways, they are often washed with low-pressure water and mild detergent. The surfaces can also be brushed and cleaned with a vacuum cleaner. In cases of marked neglect especially in restaurants, where grease and dirt have accumulated it is sometimes necessary to remove the coils and wash off the accumulation with steam, compressed air and water, or hot water. The best practice, however is to inspect and service the filters frequently.