Eclipse MC240. Double & Single Gate Controller with Eclipse Operating System (EOS) 3rd Edition. MC240 for Double and Single Gates.

Similar documents
ELSEMA MD2010. Application Controls automatic doors or gates when a vehicle is present. Description

MD12-1 Vehicle Loop Detector

MD12-2 Vehicle Loop Detector

PRODUCT INSTRUCTIONS. Fire Door Control Panel (FDCP) Stock Code Description Doc No: PI-115. Ellard Fire Door Control Panel Ellard Slave Repeater Unit

Version 1.03 January-2002 USER S MANUAL

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160

Watts Under Floor Multi-zone Controller User Manual

PRODUCT CATALOGUE. Cape Town 18 Darter Road Blue Water Estate Kommetjie. Gauteng 245 Louis Botha Avenue Orchards Johannesburg

RPSMLR2 RPSMLR2BB. Panic Device Power Controller Installation Guide LISTED. Rev

DIGITAL ALARM UNIT Model ALU-AP

Peak Partners Web-Programmable Thermostat Homeowner s Manual. Look inside for a complete guide to the setup and operation of your new thermostat.

WVD100. EZ Loop. Product Manual. Wireless Vehicle Detector. Installation Instructions Program Instructions. AP100 Relay Board S200 Sensor

SP-1000X. Panic Device Power Controller Installation Guide. Rev

The Icon Series. User Guide. CDV25 Version 1.0. Iconopm1.pm

DOLKPL1KB DOLKPS1KB DOLKSF1KB

Protégé Eclipse LED Keypad User Manual PRT-KLES

Solution 880 Operators Manual. Issue 1.00

REPEATER FS5200R INSTRUCTION MANUAL

Revision November 2013 JVA Technologies. Ethernet General Purpose IO Technical Manual

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL. FT-EPB Series. Single Motor

Door Release Power Supply

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

Smart Temp. ApolloP/n Installation Manual. Version 1.0

DTS SECURITY P.O.BOX 3399 Base plate-mounting EDENVALE instructions 1610 TELEPHONE

Remote Vacuum Sensor and Variable Speed Vacuum Pump Control Manual. Version Date - June Part Number

Conventional Fire Alarm System 2014 V1.2

Interactive Fire Control Panel IFS7002 one signal loop Instruction Manual

Installation, Operating and Maintenance Manual

IDS816 User Manual H Issued January 2009

Odyssey. issue 01c. system manual

AXI LED USER MANUAL (REV. 1.0)

Programmable Room Thermostat Installation Instructions

ORP (mv) Controller Model: ORP-XP2. UP DOWN ENTER Time & Date Main Menu Alarm Reset

Security Alarm System Owner's Guide 8 sector CDS Dialler 8-24 sector Control Dialler 8-24 sector Control Securitel Version 1.0 lcopm.

CommStat 4. Controller for Redundant Telecom HVAC Systems PRODUCT DATA SHEET. Features and Benefits

SMART SWITCH TECHNOLOGIES. SmartSwitch Yacht-Guard Model SMS-8 Vessel System Monitor Installation Manual

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6535D, 6537C, 6538 A&B SERIES TWO TON PACKAGED HIGH EFFICIENCY HEAT PUMPS

EXPERT TRI-STAR. Temperature controller. User s Manual

SPECTRA 1727 USER S GUIDE

Ocean Breeze Model QU700 Programmable Digital Touchscreen Climate Control

IT801 Thermostat. User s Manual. The complete guide to the set up and operation of your new smart Wi-Fi thermostat.

WARNING FIRE DOOR CLOSING

Sentry 4 Zone Alarm Panel User Manual

AVANT DGi. Thermal Electric Radiator. Operating and Installation Instructions. (Read these instructions carefully and retain for future reference)

User s Information Guide R2A

Walk-Through Metal Detectors Technical Comparison Chart

Contents. Glossary

RF Programmable Room Thermostat Installation Instructions

NESS 5000 SERIES DIALLER

NESS D8 CONTROL PANEL AND DIALLER

HRX Technical Manual. Version 1.2

CONTROL DEVICE SLIDETRONIC HD

IDS S E C U R I T Y IDS816. User Manual. MANUAL NO A ISSUED November 2004 VERSION 1.00

MOBILE CALL GSM Alarm System User s Manual

Watchguard WGAP864 User Manual

BS-316. Gas detection control panel up to 16 inputs. Installation operation manual

1 measurement signal input 4-20 ma for connection to an external gas sensor 5 freely programmable alarm switching points per measuring point

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL. FST-EPB Series. Single Motor

Digital Control Unit- Installation, Operation & Maintenance IMPORTANT INFORMATION

MC200. Users Instructions. HEATING DIVISION Hort Bridge Ilminster, Somerset TA19 9PS Tel: Fax:

Satchwell. DC1100 Energy Controller SELF CONFIGURING OPTIMISER/COMPENSATOR WITH BOILER SEQUENCE AND HWS CONTROL FEATURES

Controllers. Centralization of Access Control Devices Made Easy. Installer Guide

VAV Thermostat Controller Specification and Installation Instructions. Model TRO24T4XYZ1

STERLING 10 Control Panel with Remote Keypads ICON and LCD INSTALLATION MANUAL

5000 SERIES 8 ZONE INSTRUCTION MANUAL

Feature Summary. I. System

Openers ROLLING AND OVERHEAD SECTIONAL GARAGE DOORS

WARNING Important Safety Information

Memcom Emergency Telephone

Flopurge TS. Operation Manual

Control Panel User Guide

Flostop TS D7E and A8E. Operation Manual

CSP-204 CSP-208 CSP-104 CSP-108

VA301C CONTROLLER WITH BACnet OPTION

WARNING Important Safety Information

WARNING Important Safety Information

Challenger Series Users Manual


MG Partition 64-Zone Wireless Console with GPRS/GSM Version 1.6. Section Programming Guide

Accenta/Optima. User Guide. UK Security Panels. Servicing Organisation (Installer) name: Telephone Number: Date of Installation: Account Number:

TOTAL SOLUTIONS. Liquid Level Control Product Guide. MATELEC AUSTRALIA innovative by design

INPUT / OUTPUT MINI MODULES

Challenger Version 8 Programming Relays.

Auto Dialer. Manual E-921APQ E-921GPQ

Across-the-Line SERIES MP300 Combined Manual and Automatic

SECURIT 700L PLUS ENGINEERING MANUAL

MADE IN THE U.S.A. ADVANCE FIRE CONTROL MODEL LM21-AFC MANUAL RELEASE DEVICES TEST WEEKLY TO ASSURE PROPER OPERATION OF RELEASE DEVICE/CONTROL PANEL

ID50series. intelligent fire alarm panels

D3000. Installation & Setup Guide

TCONT402AN32DA. Owner s Manual. Comfort Control XR402. Pub. No Fan Mode. Filter/OD

HRX3000. Technical Manual

MC4000 Series Advanced Solid State Dual Unit Lead/Lag Controller with Ethernet Remote Communication Option

Fire-Cryer. Plus Application Guide APPLICATION GUIDE FIRE EXIT VIMPEX. Shaping Alarm Technology

THE FUTURE OF RETRACTABLE BOLLARDS BULLYBOY PRODUCT INFORMATION

Mini. Level Control systems For Manual Sump Pumps up to 750W 1 or 2 Pump Systems

D-TECT 3 IP. GJD260 IP Motion Detector

MPT Electric Fire Pump Controller

Ethernet General Purpose

Power Wave LCD Keypads. Users Operating and Programming Guide Version 2.00

TO ARM/DISARM ALARM The alarm is activated by pressing BUTTON 1 on the remote control transmitter once. The blinkers will flash once, and the

Transcription:

3rd Edition Double & Single Gate Controller with Eclipse Operating System (EOS) Eclipse MC240 www.elsema.com MC240 for Double and Single Gates Setup and Technical Information Includes latest Intelligent Technology

Important warning and safety instructions All installations and testing must be done only after reading and understanding all instructions carefully. All wiring should be done only by trained technical personnel. Failing to follow instructions and the safety warnings may result in serious injury and/or damage to property. Elsema Pty Ltd shall not be liable for any injury, damage, cost, expense or any claim whatsoever to any person or property which may result from improper use or installation of this product. Risk in the goods purchased shall unless otherwise agreed in written pass to the buyer upon delivery of the goods. Any figures or estimates given for performance of goods are based upon the company s experience and is what the company obtains on tests. The company will not accept liability for failure to comply with the figures or estimates due to the nature of variable conditions affecting for example Radio Remote Controls. Please keep this setup instruction for future reference. Installed by: Service date: 2 Double Gate & Door Controller with Eclipse Operating System (EOS)

Index Features...4 Description...4 Part Number...5 Menu Structure... 6-7 Connection Diagram...8 Operations Control...9 Supply and Motor Inputs...10 Inverter Connection...11 Limit Switches...12 Setup i-learning Steps...13 Menu 1 Auto Close...14 - Normal Auto Close...14 - Auto Close with Photoelectric Trigger...14 - Auto Close after Power Failure is Removed... 14 - Auto Close Only when Fully Opened...14 - Auto Close Only at Night...14 Menu 2 Pedestrian Access Features... 15-16 Menu 3 Input Functions...16 Menu 4 Photoelectric Beam...17 Menu 5 Output Functions...18 - Lock/Brake Output...18 - Courtesy Light...18 - Service Call Output...19 - Strobe or Warning Light...19 Menu 6.1 Lock/Brake Output Modes...20 - Open Lock/Brake Activation...20 - Close Lock/Brake Activation...20 - Open Pre-Lock/Brake Activation...20 - Close Pre-Lock/Brake Activation...20 Menu 6.2 Courtesy Light Output Mode...21 Menu 6.3 Strobe (Warning) Light Output Mode...21 - Pre-Open Strobe Light Activation...21 - Pre-Close Strobe Light Activation...21 Menu 6.4 Service Call Output Mode...22 Menu 6.5 Locking Actuator Mode...22 Menu 7 Special Features...23 - Remote Control Open Only...23 - Holiday Mode...23 - Energy Saving Mode...23 - Automatic Stop / Open on Closing...24 - Receiver Channel 2 Options...24 - Press and Hold on Open & Close Inputs...24 Menu 8 Leaf Delay...24 - Open Leaf Delay...24 - Close Leaf Delay...24 Menu 9 Motor 1 Force & Overrun Time Open & Close Force...25 Overrun Time...25 Menu 10 Motor 2 Force & Overrun Time Open & Close Force...25 Overrun Time...25 Menu 11 Slow Speed Area and Reverse Time...26 - Open and Close Speed...26 - Slow Speed Area...26 - Stop Reverse Delay Time...26 Menu 12 Anti-Jam, Electronic Braking and Hydraulic Lock...27 Menu 13 i-learning...27 Menu 14 Password...27 Menu 15 Operational Records...28 - Event History...28 - Displays Gates/Doors Operations... 28 Menu 16 Tools...29 - Number of Motors...29 - Resets Controller...29 - Test Inputs...29 - Travel Timer...29 - Day and Night Sensitivity Adjustment...29 Accessories...30 - Keyring Remotes...30 - Strobe Lights...30 - Photoelectric Beams...30 PentaFOB Programming Instructions...31 www.elsema.com 3

Features Suitable for swing and sliding gates Double or single motor operation Eclipse Operating System (EOS) Day and night sensor (DNS) Motor soft start and soft stop Slow speed and force adjustment Large 4-line LCD to indicate controllers status and setup instructions 1-Touch control for easy setup Various inputs, push button, open only, close only, stop, pedestrian and photoelectric beam Supports limit switch inputs or mechanical stops Adjustable auto close and pedestrian access Adjustable lock and courtesy light outputs Variable photoelectric safety beam functions 12 Volt DC Output to power accessories Auxiliary input for fire alarms. Service counters, password protection, holiday mode and many more features Description The 240 Volt AC Motor Controller (MC240) is not just the next generation but the industry game changer. We wanted to create a controller that is simple to use and does just about any feature required in the gate and door industry. The MC240 is not just the next generation but the Next Transformation in the gate and door industry creating an Eclipse over previously developed motor controllers. This new intelligent motor controller is the best match for your automatic gate or door motors. The MC240 s Eclipse Operating System (EOS) is a user friendly menu driven system that uses the 1-touch button to control, setup and run automatic gates, doors and barriers. It uses a large 4-line LCD screen showing live reading of the motor performance and status of all inputs and outputs. The intelligent controller was built from the ground up, based on customer feedback and using todays technology. With its rich functions, consumer friendly price and with the focus during development being ease of use and setup makes this controller the ultimate board to control your motors. Elsema s easy options to add remote controls or any type of photoelectric beams makes for a very user friendly approach, while avoiding the lockdown approach to accessories. The control cards are available with an IP66 rated plastic enclosure for outdoor installations or the card only. 4 Double Gate & Door Controller with Eclipse Operating System (EOS)

MC240 MC240E www.elsema.com 5

Active 4 1 3 2 NC MT1 K NC A MT2 NC MT1 K A MT2 16 15 14 13 12 11 10 1 2 3 4 5 6 7 8 9 MC240 Connection Diagram Day and Night Sensor 140mm AC DNS Supply Antenna Shield Antenna Powered By Eclipse operating system Code Reset 10 sec Prog1 Prog2 Penta Receiver Built-in Receiver 130mm Master Control Output 2 C ELSEMA Output 2 NC Output 2 NO Open Close Stop Output 1 C FUSE Output 1 NC Output 1 NO AC Earth Supply AC Acti Supply ve AC Neutral Supply AC Open Supply AC Close Supply AC Neutral Supply AC Open Supply AC Close Supply AC Neutral Supply Motor 1 Open Limit Motor 1 Close Limit Common Motor 2 Open Limit Motor 2 Close Limit Common Aux Input Push Button Open Close Stop Common PED Access Photo Beam + 12 VDC - 12 VDC 240V AC Supply Motor 1 Motor 2 Normally Closed User can change Normally Open User can change Normally Closed User can change DNS Connection : On the top left corner of the control card is a connection for Day and Night Sensor (DNS). This sensor is available from Elsema and is used to detect day and night. This feature can be used to auto close the gate at night, turn on the courtesy light or lights on your gates during the night and many more features which require a day and night detection. 6 Double Gate & Door Controller with Eclipse Operating System (EOS)

For a full version of this manual contact us www.elsema.com 7

Menu 15 Operational Records This is for information only. Menu No. Operational Records 15.1 Event History, up to 100 events are recorded in the memory 15.2 Displays Gates/Doors Operations 15.3 Exit 15.1 Event History The event history will store last 100 events. The following events are recorded into the memory: Power On, All input activations, Successful opening, Successful closing, Auto close, i-learning and Factory Reset. 15.2 Displays Gates/Doors Operations This displays the number of open cycles, close cycles and pedestrian cycles. 28 Double Gate & Door Controller with Eclipse Operating System (EOS)

Menu 16 Tools Menu No. Tools 16.1 Number of Motors, Single or Double Gate System 16.2 Resets Controller to Factory Settings 16.3 Test Inputs 16.4 Travel Time 16.5 Day and Night Sensitivity Adjustment for the DNS 16.6 Open Hydraulic Locking 16.7 Close Hydraulic Locking 16.8 Exit 16.1 Number of Motors This allows you to manually set the control card to a single motor or a double motor. 16.2 Resets Controller Reset all settings to factory default. Also removes password. 16.3 Test Inputs This allows you to test all the external devices connected to the controllers inputs. UPPERCASE means input is activated and lowercase means input is deactivated. 16.4 Travel Timer This allows you to use the controller with travel timers. Motor 1 and 2 can have separate open and close travel timers up to 120 seconds. Used for Hydraulic Motors. 16.5 Day and Night Sensor This option is only available when Day and Night Sensor (DNS) is connected. It allows you to adjust the senstivity of the sensor. This sensor can than be used to switch On courtesy light only at night or enable Auto Close only at night. www.elsema.com 29

Accessories Keyring Remotes The latest PentaFOB keyring remotes with mini receivers ensure your gates or doors are secure. Visit www.elsema.com for more details. Photoelectric Beam Elsema has several types of photoelectric beams including retro-reflective and through beam with IP-66 ratings. Strobe Lights Elsema has several strobe lights to act as a warning when the gate or doors is in operation. PentaFOB Remotes Flasher Lights Locking Actuator LA24 30 Double Gate & Door Controller with Eclipse Operating System (EOS)

PentaFOB Programming Instructions Coding the PentaFOB remotes and receivers can be done in 2 different ways. 1. Using the Receiver 2. Using another Remote Control Coding using the Receiver 1. Press and hold the program button on the receiver 2. Press the remote button for 2 seconds, receiver LED will flash and then turn Green 3. Release the button on the receiver and the remote 4. Press remote control button to test the receiver output Coding using another Remote Control (you should be near the receiver for this procedure) 1. Open the case of a remote control that is already programmed and press and release the program button on the back of the board (The receiver enters learning mode) 2. Press the button of the remote in step 1 which activates the receiver 3. Press the button on the new remote which needs to be programmed for 2 seconds 4. Press the program button again of the remote in step 1(The receiver exits learning mode) 5. Press the new remote control button to test the receiver output Deleting Receivers Memory Short the Code Reset pins on the receiver for 10 seconds. This will delete all the remotes from the receiver s memory. PentaFOB Programmer This programmer allows you to add and delete certain remotes from the receiver memory. This is used when a remote control is lost or a tenant moves from the premises and the owner wants to prevent un-authorised access. PentaFOB Backup Chips This chip is used to backup or restore the contents of a receiver. When there are 100 s of remotes programmed to a receiver the installer normally backups the receiver memory in case the receiver is damaged. www.elsema.com 31

Keyring remote controls Sliding gate motor kits Swinging gate motor kits Sliding gate motor kits Swinging gate motor kits Motor control cards & Kits ELSEMA PTY LTD 31 Tarlington Place Smithfield NSW 2164 Australia P 02 9609 4668 F 02 9725 2663 W www.elsema.com