IEC Lighting Contactor Specifications

Similar documents
CENTERLINE 2100 Motor Control Center (MCC) Doors and Units with Vertical Operating Handles

Solid-State Contactor Specifications

Magnetically Coded Non-contact Switch (MC2)

Bulletin 1608N MiniDySC Dynamic Sag Corrector

Safety Function: Single-beam Area Access Control (AAC)

Lifeline 5 Cable-pull Safety Switch

Molded Case Circuit Breakers, Bulletin 140G

Compact I/O End Caps/Terminators

Bulletin 140G Molded Case Circuit Breakers Product Selection 225 A, I-Frame

BULLETIN 600 SINGLE PHASE

Contender Series Factory Sealed Manual Motor Starters and Contactors Explosionproof, Dust-Ignitionproof

APPLICATIONS APPLICATIONS APPLICATIONS APPLICATIONS APPLICATIONS

Contender Series Factory Sealed Manual Motor Starters and Contactors Explosionproof, Dust-Ignitionproof

Alarm Coordination Connected Components Building Block. Quick Start

XM-441 Expansion Relay Module

PT101. General. Full Stroke Range Options. Potentiometer Cycle Life Maximum Retraction Acceleration. Electrical

Reference Manual. Common Alarm Block (P_Alarm) Version 3.1

Wall-Mount Preferred-Cutout Disconnects Hoffman WATERSHED Wall-Mount Disconnects

Advanced Autodesk Authorized Training Courseware (AATC) AutoCAD. Architecture 2009

Accessories for SMA Inverters Fan Retrofit Kit FANKIT02-10

XM-360 Process Module, XM-361 Temperature Module, and XM-362 Isolated Temperature Module

ORIGA-SENSOFLEX Displacement Measuring System for Cylinder Series OSP-P

ACCS-30. Multipoint commercial heat-tracing control system

SensaGuard TM Integrated Latch Installation Instructions

Bulletin 609 Single And Three Phase

NoZone Ozone Scrubber

FTA200-A REMOTE ALARM PANEL

XM-440 Master Relay Module

Accessories for SMA Inverters Fan Retrofit Kit FANKIT02-10

Standard Product. Wall-Mount Preferred-Cutout Disconnects Hoffman WATERSHED Wall-Mount Disconnects

Training Yard Control Panel

Bulletin 440N-Z 440N-S 440K 440G. Sipha Magnetically Coded Non Contact Switches

EDS Series Factory Sealed Manual Motor Starters and Contactors Explosionproof, Dust-Ignitionproof

FR/SR Series. Full Sized, Sealed Rocker Switches SR SERIES FR SERIES DESCRIPTION FR SERIES SR SERIES FEATURES FR SERIES SR SERIES

Scale 0: 10 k Scale 50: 10 k (see note 2)

AM54. Armored Variable Area Flowmeter Series AM54331/32 Series AM54371/72/73/74 Series AM54431/32 Series AM54471/72/73/74

Cable Actuated Sensor Industrial User Scalable VDC Output

PT9420 (Extended Range)

Installation and Operations Manual

Cable Actuated Sensor Industrial Incremental Encoder Output

Intrinsically Safe Transmitters, Option Code 2n

Model Number Structure

MICRO SWITCH BX/BX2 Series

SGJ. 80, 120-inch Stroke Range Options. Polycarbonate Enclosure IP67. In Stock for Quick Delivery. General. CANbus Specifications

PT9150 (Extended Range)

ISO INTERNATIONAL STANDARD. Agricultural engineering Electrical and electronic equipment Testing resistance to environmental conditions

Cable Actuated Sensor Industrial User Scalable 4 20mA

ES2-HB. Ordering Information. Dimensions. Specifications. Humidity Sensor Temperature/Humidity Sensor

Appearance and sensing characteristic Specification (temperature range) Model 10 to 70 C ES1B. 2 mm 20 mm 40 mm 60 mm. 40 dia. 60 dia.

Ultrasonic Reflective Sensor

INSTRUCTIONS. OJ-DV-Relay-Module. OJ Drives A DRIVES PROGRAMME DEDICATED TO VENTILATION SOLUTIONS. Optional module for OJ-DV motor controller

PT9101. General. Potentiometer Cycle Life 250,000 Maximum Retraction. Weight, Aluminum (Stainless 8 lbs. (16 lbs.) max. Electrical

Technical Publications. FactoryTalk Alarms and Events System Configuration Guide

Original instructions Sense7-series Non-contact coded safety switch

F261 Series Fluid Flow Switches

Original instructions INCA-1 Emergency stop for enclosure installation INCA-1S Safety stop for enclosure installation

Electric Duct Heaters

PolySwitch TS600 Overcurrent Protection Devices

Ultrasonic Reflective Sensor

Radar Transmitters SITRANS LR400 (HART/PROFIBUS PA) Quick Start Manual 03/2013 SITRANS

Explosion Protected Panelboards D2Z Series

P R O D U C T C A T A L O G U E

ISO 6396 INTERNATIONAL STANDARD. Earth-moving machinery Determination of emission sound pressure level at operator's position Dynamic test conditions

Power and Energy Management Solutions

UFGS (August 2011) UNIFIED FACILITIES GUIDE SPECIFICATIONS

NEMA Standards Publication ICS (R 2007) Adjustable Speed Electrical Power Drive Systems

UFGS (November 2008) UNIFIED FACILITIES GUIDE SPECIFICATIONS

Installing the assembly SIMATIC. Installing the assembly. Overview 1. Installing the assembly. Getting Started A5E

HT-1300 Series. Temperature and Humidity Duct Sensor. Product Bulletin. Power Supply VDC / 24 VAC. Humidity Accuracy 2.5% RH from 10 to 95% RH

100A / 200A. Maximum Heating Load: Enclosure Type: NEMA 4

Functional Safety Manual June pointek CLS500/LC500

ISO 3858 INTERNATIONAL STANDARD. Rubber compounding ingredients Carbon black Determination of light transmittance of toluene extract

NetworkAIR RM Air Distribution Unit

Model ELOC 11.2 K-factor Extra Large Orifice Concealed Pendent Sprinklers Quick and Standard Response, Extended Coverage

MICRO SWITCH NT Series

WIO200 Water in oil sensor

NIR O P E R A T I N G I N S T R U C T I O N S RETROREFLECTIVE PHOTOEYE U L M O N I T O R E D DEVICE

Quick-Start Operating Guide Document No Acrylic Vacuum Chambers Copyright 2010 Terra Universal Inc. All rights reserved. Revised October 2010

Nest x Yale Lock Installation and Programming Guide. Back button Check (Set / Continue) Keypad

Allure EC-Smart-Air Series Communicating sensors

MICRO SWITCH NT Series

User s Guide Home Automation Wall Socket for IWATCHALARM (Add-On) Model: SM-001SK

Regulated Ex-Heater HEX with internal controller, HEX with external controller II 3 G II 3 D

Temperature, Mechanical

FINAL DRAFT INTERNATIONAL STANDARD

ILLUSION 11.2 K-factor Extra Large Orifice Concealed Pendent Sprinklers Quick Response, Standard Coverage General Description

Netbiter Tank Sensor

ES2-HB-N. Ordering Information. Specifications. Temperature/Humidity Sensor ES2-THB-N. Humidity Sensor

Installation and operation manual DPC200 - DIFFERENTIAL PRESSURE CONTROLLER. Low pressure with PI-control-mode

TTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required.

Introducing New 96-Well Fast Plate Adapters for Applied Biosystems Capillary Electrophoresis Systems

SKJ. Specifications. Stroke Range Options 250 inches (6.4 m), 400 inches (10.2 m)

IntelliDoX Operator Manual

Embedded Linux with VAR-SOM-MX6 Course

MICRO SWITCH Key Actuated Safety Switches GKN Series Issue 3. Datasheet FEATURES POTENTIAL APPLICATIONS DESCRIPTION DIFFERENTIATION PORTFOLIO


Installation, Operation & Service Manual

Power Blocks - Splicer/Distribution

Installation and Operating instructions for. C9900-U battery pack. Version: 2.0 Date:

Ex SOLENOID / ALARM DRIVER. PRepower 5203B. Table of contents. Applications Safety instructions Technical characteristics...

Transcription:

Technical Data IEC Lighting Contactor Specifications Bulletin Number 100L Topic Page Product Overview 2 Specifications 2 Wiring Diagrams 3 Approximate Dimensions 3 Additional Resources These documents contain additional information concerning related products from Rockwell Automation. Resource Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1 Product Certifications website, http://www.ab.com Description Provides general guidelines for installing a Rockwell Automation industrial system. Provides declarations of conformity, certificates, and other certification details. You can view or download publications at http://www.rockwellautomation.com/literature/. To order paper copies of technical documentation, contact your local Allen-Bradley distributor or Rockwell Automation sales representative.

Product Overview Bulletin No. Contactor Type Features 100L IEC Multi-pole Electrically held Continuous Ampere Rating [A] 20 Single phase, 1 or 2 power poles Three phase, 1 or 2 power poles Enclosures (NEMA Type) Standards Compliance Certifications 20 A 277V Max 15 A 347V Max 20 A 480Y/277V Max 15 A 600Y/347V Max IP42 (Type 1) IP66 (Type 3/4/12) UL 508 CSA C22.2, No. 14 culus Listed (File No. E14843, Guide No. NRNT, NRNT7) Specifications Ratings Type of Load Max. Current [A] Max. AC Volts, Poles to Load (1) 1 for 1-phase 3 for 3-phase Tungsten Ballast 20 277 480Y/277V 15 347 600Y/347V 20 277 480Y/277V 15 347 600Y/347V General use resistance heating 30 600 600 (1) 20 A, 250V DC max. with 3 poles in series. 2 Rockwell Automation Publication 100-TD014B-EN-P - April 2015

Wiring Diagrams 4 Poles 8 Poles 12 Poles Approximate Dimensions Dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes. Open Type 45 (1-49/64) 4-Pole 35 (1-23/64) 6 (1/4) 81 (3-3/16) 60 (2-23/64) 4.5 (3/16) Dia. Mounting Holes 91 (3-19/32) 8-Pole 136 (5-11/32) 12-Pole 80.5 (3-11/64) Rockwell Automation Publication 100-TD014B-EN-P - April 2015 3

IP42 (Type 1 23.4 (15/16) A C D B F E 7.1 (1/4) Dia. for 1/4 in. or M6 Screw 3 Mounting Holes Cat. No. A Wide B High C Deep D E F 100L-C20A 4 140 (5-1/2) 220 (8-21/32) 152 (5-31/32) 175 (6-7/8) 95 (3-3/4) 22.5 (7/8) 100L-C20A 8 235 (9-1/4) 220 (8-21/32) 152 (5-31/32) 175 (6-7/8) 190 (7-1/2) 22.5 (7/8) 100L-C20A 12 270 (10-5/8) 290 (11-7/16) 152 (5-31/32) 245 (9-21/32) 225 (8-7/8) 22.5 (7/8) IP66 (Type 3/4/12) G F A E 4 5.5 (7/32) X 7.1 (1/4) Mtg. Holes C 7.1 (1/4) H D B 6 (15/64) K J 4 5.5 (7/32) Dia. Mounting Holes Cat. No. A Wide B High C Deep D E F G H J K 100L-C20F 4 200 (7-7/8) 300 (11-13/16) 160 (6-5/16) 236 (9-9/32) 76 (3) 62 (2-7/8) 17.5 (11/16) 313 (12-5/16) 105 (4-1/8) 47.5 (1-7/8) 100L-C20F 8 250 (9-27/32) 250 (9-27/32) 160 (6-5/16) 186 (7-5/16) 76 (3) 87 (3-7/16) 17.5 (11/16) 263 (10-3/8) 105 (4-1/8) 72.5 (2-7/8) 100L-C20F 12 300 (11-13/16) 300 (11-13/16) 160 (6-5/16) 236 (9-9/32) 76 (3) 61 (2-13/32) 17.5 (11/16) 313 (12-5/16) 206 (8-1/8) 47 (1-27/32) 4 Rockwell Automation Publication 100-TD014B-EN-P - April 2015

Notes: Rockwell Automation Publication 100-TD014B-EN-P - April 2015 5

Important User Information Read this document and the documents listed in the additional resources section about installation, configuration, and operation of this equipment before you install, configure, operate, or maintain this product. Users are required to familiarize themselves with installation and wiring instructions in addition to requirements of all applicable codes, laws, and standards. Activities including installation, adjustments, putting into service, use, assembly, disassembly, and maintenance are required to be carried out by suitably trained personnel in accordance with applicable code of practice. If this equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. In no event will Rockwell Automation, Inc. be responsible or liable for indirect or consequential damages resulting from the use or application of this equipment. The examples and diagrams in this manual are included solely for illustrative purposes. Because of the many variables and requirements associated with any particular installation, Rockwell Automation, Inc. cannot assume responsibility or liability for actual use based on the examples and diagrams. No patent liability is assumed by Rockwell Automation, Inc. with respect to use of information, circuits, equipment, or software described in this manual. Reproduction of the contents of this manual, in whole or in part, without written permission of Rockwell Automation, Inc., is prohibited. Documentation Feedback Your comments will help us serve your documentation needs better. If you have any suggestions on how to improve this document, complete this form, publication RA-DU002, available at http://www.rockwellautomation.com/literature/. Allen-Bradley, Rockwell Software, Rockwell Automation, and LISTEN. THINK. SOLVE are trademarks of Rockwell Automation, Inc. Trademarks not belonging to Rockwell Automation are property of their respective companies. Rockwell Otomasyon Ticaret A.Ş., Kar Plaza İş Merkezi E Blok Kat:6 34752 İçerenköy, İstanbul, Tel: +90 (216) 5698400 Publication 100-TD014B-EN-P - April 2015 Supersedes publication 100-TD014A-EN-P - August 2014 Copyright 2015 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.