THE THERMOSTATIC STEAM TRAP

Similar documents
THERMOSTATIC STEAM TRAPS

LIQUIDATOR 450 SERIES

LIQUIDATOR UMT-TD Series Thermodynamic

THERMODYNAMIC STEAM TRAPS

Inverted Bucket Float & Thermostatic Radiator Traps STEAM CONTROL PRODUCTS STEAM TRAPS

NICHOLSON STEAM TRAP THERMODYNAMIC STEAM TRAPS

YARWAY PROCESS THERMODYNAMIC STEAM TRAPS SERIES 40/40D AND C250/260

Technical Data CONDENSATE COMMANDER PUMP SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 9902D

FT600 & FT601* Steam Traps Float & Thermostatic Steam Trap. Float & Thermostatic STEAM TRAPS

Series 151 and AV5. A wide range of process thermostatic steam traps is available to match almost any application need.

Hoffman Specialty General Catalog

YARWAY PROCESS THERMOSTATIC STEAM TRAPS SERIES 151 AND AV5

TABLE OF CONTENTS STEAM TRAPS INVERTED BUCKET SERIES PAGE FLOAT AND THERMOSTATIC SERIES PAGE THERMOSTATIC THERMODISC B0 26. How to Select All 107

PT15 MATERIAL : DIMENSIONS - Nominal in inches. AVAILABLE SPARES: Disc (Packet of 5) ORDERING INFORMATION: Refer to "HOW TO ORDER" page.

UNIVERSAL STYLE STEAM TRAPS WU450 Series

Steam and Condensate Technology. Solutions which are brilliant in their simplicity. combined with a first-class design & consultancy service.

Economical and simplified solutions that offer quality and optimum steam trap service.

YARWAY NON-REPAIRABLE DRIP AND TRACER STEAM TRAPS SERIES PB, 29, 129Y AND 29S

Steam Traps and Steam Specialties

High Capacity Instantaneous Steam Fired Water Heater

Installation and Maintenance "L" and "LS" Series

Installation and Testing of Inverted Bucket Steam Traps Manual

Float & Thermostatic Steam Traps for efficient condensate drainage of industrial process and HVAC equipment

THERMODYNAMIC STEAM TRAPS

Main Steam Vents. Hoffman Specialty Regulators. How to Select Steam Vents

Yarway Repairable Drip and Tracer Steam Traps Series 751/761, 711/721, 731/741, 500/546, 460/515/D3

Our Know-How. Your Peace of Mind. Steam Solutions

Liquid Drainers LIQUID DRAINERS

WHY THE REMOVAL OF NONCONDENSABLE GASES AND AIR IS CRITICAL IN A STEAM SYSTEM

STEAM TRAPS

ICS Float and Thermostatic Steam Trap Installation and Operation Manual

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD

SH-300, SH-900, SH-1500, SH-1600 and SH-1700 Bimetallic Steam Trap Installation and Operation Manual

Clean Steam Generators

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT

Armstrong J Series Float, Thermostatic Steam Traps, Condensate Controllers & Liquid Drainers Installation and Maintenance Manual

AIC Series Float & Thermostatic Steam Trap Installation and Maintenance Instructions

SH-2000, SH-2500, AB-3000 Bimetallic Steam Traps Installation and Operation Manual SH-2000

COMMERCIAL ITEM DESCRIPTION TRAPS, STEAM

Insty-Pac Steam Humidifiers

The right trap for the right application.

Bringing Energy Down to Earth

Instant hot water Feed-Forward system unlimited supply accurate to +/- 4 F

Pamphlet A2404. Mechanical Pump & Pump/ Trap. GP Series GT Series

VENTS. Main Steam Vents. How to Select Steam Vents. For Steam Vent selection information, please refer to Selection Guidelines on page 133.

PIP PNE00004 Steam Trap Guidelines

AIC Brazed Plate Heat Exchanger Operating and Instruction Manual

Condensate Pumps Jones Boulevard Limerick Airport Business Center Pottstown PA Tel:

Inverted Bucket Steam Traps. for efficient condensate drainage of industrial and HVAC equipment

BASICS OF STEAM TRAPS BASICS OF STEAM TRAPS

Steam Trap Presentation for IDEA Distribution Workshop. Presenter: Joe Radle

Removal of Non-condensable Gases and Air Is Critical In A Steam System

Wallace & Tiernan Gas Feed Systems V2000 Chlorinator

Ball Float Controlled. Thermo Dynamic(TD) Trap Safety Valve Condensate Pump Flash Vessel Moisture Separators Deaerator Head Steam Injector Sight Glass

UFGS (May 2010) UNIFIED FACILITIES GUIDE SPECIFICATIONS

STEAM CONSERVATION GUIDELINES

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Mini Pump Trap. Features: n Low maintenance - No leaking seals, impeller or motor problems reducing maintenance and downtime.

Rev. None AUGUST 2012 MDM SERIES MODULAR MEMBRANE AIR DRYERS OPERATOR MANUAL MDM1 MDM4 MDM9 MDM13 MDM24 MDM49 MDM66 MDM106 MDM138

Steam Conservation Guidelines for Condensate Drainage Steam Trap Sizing and Selection.

How to Trap: Trap Selection and Safety Factors

Jet Compressors. Circulate Steam Boost Low-Pressure Steam Compress and Mix Gases in Desired Proportion

S and SF Inverted Bucket Steam Traps Installation and Maintenance Instructions

Steam Traps. . Chambered valves such as; bleeding & venting valves and steam traps. Float Valves using a free fl oat

STEAM TRAPS FOREST PRODUCTS LIBRARY FOREST RESEARCH LABORATORY OREGON STATE UNIVERSITY. Information Reviewed and Reaffirmed. August No.

How to Trap: Installation and Testing

Chapter 2.3: Steam System

Steam Trap Selection

Steam Conservation Guidelines for. Drainage. Mead O'Brien (800) LP Steam. Condensate. HP Steam RECEIVER TANK HEATER

How to Trap: Process Air Heaters

MODELS N150/300/675/900/1500/2500/2600 INSTALLATION, SERVICING AND MAINTENANCE INSTRUCTIONS

Carbon Monoxide (CO) Detecting Ventilation Fan Controller Model 120VC Single Relay (100/25 PPM) (200/35 PPM)

Boiler Condensate Return Basics. Presented by Steve Connor February 24, 2016

AIR CONDITIONING. Carrier Corporation 2002 Cat. No

Pamphlet U2404. Mechanical Pump & Pump/ Trap. GP Series GT Series

Pamphlet M2404. Mechanical Pump & Pump/ Trap. GP Series GT Series

Spirax-Sarco Industrial Thermostatic Steam Traps

Installation, Operation and Maintenance LOK-FLANGE Multitube Heat Exchangers

Silhouette. Feedwater Heater. Boiler Feedwater

How to Trap: Troubleshooting

Packaged Steam Fired Water Heater

Pure Performance For Steam Mains and Tracers

How to Trap: Steam Tracer Lines

MCD. Corona Discharge Ozone Generators MANUFACTURED BY Bullock Lane San Luis Obispo, CA

Section H11 BLOWDOWN SEPARATORS CONTENTS FEATURES AND BENEFITS...H11-3 PRODUCT OFFERING...H11-3 SAMPLE SPECIFICATIONS...H11-11 ILLUSTRATIONS

MFP14 Automatic pumps for condensate and other industrial fluids

DESIGNED BY FIRE FIGHTERS FOR FIRE FIGHTERS.

INSTRUCTION MANUAL HS-229G

Armstrong Steam System Solutions for the Hydrocarbon and Chemical Processing Industries

Model OP155 Air Dryer

Essex County College - West Essex Campus Addition And Renovations dib # / SECTION HYDRONIC PIPING SPECIALTIES PART 1- GENERAL

DRY-PAK INDUSTRIAL AIR DRYER Installation and Instruction Manual

Pump & Trap Combinations

INFRARED RADIANT HEATER RSCA SERIES CERAMIC HEATERS NATURAL GAS PROPANE GAS DATE: PROJECT: ARCHITECT/ENGINEER: CONTRACTOR: SUBMITTED BY:

Air Vents AV-392. Proven Same proven, free-floating all stainless steel mechanism as used in Armstrong steam traps.

STAINLESS STEEL TRAP VALVE STATION

PRODUCTS. Expansion Joints Fire Fighting. Flexible Metal Hoses. Equipments. Insulation Solutions. Steam. Valves. Level Control.

Model CV-1FR Riser Check Valves 2 to 12 Inch (DN50 to DN300) General Description. Installation. Technical Data. Page 1 of 6 OCTOBER 2010 TFP950

INSTRUCTIONS FOR OPERATION AND CARE OF. P.O. Box 3527 City of Industry, CA, , U.S.A

Hydrocarbon & Chemical Processing Solutions

Transcription:

THE THERMOSTATIC STEAM TRAP The purpose of any steam trap is to discharge, promptly, all condensate (as well as air and other non-condensible gases) without discharging live steam. Since steam is a vapor formed when heat is added to water, it follows that it reverts back to water, or condensate, when heat is extracted. This condensate must be removed from lines and equipment as rapidly as possible, for hot water contains too little heat for efficient performance. Air, too, must be removed, since it lowers the temperature of the steam and acts as an insulator. All steam traps must be classified, broadly, under three types: thermostatic, thermodynamic, and mechanical. Thermostatic traps include bellows and differential metal-expansion designs. The efficiency of an expensive piece of equipment can be reduced as much as 20% through sluggish drainage of condensate and failure to remove air. Proper selection of the right type and size steam trap assures uniform heating and higher temperatures, resulting in increased production. For most heat-transfer applications, an intermittent-action trap is most efficient. Fast, intermittent valve action in the thermostatic bellows trap provides rapid drainage of condensate and venting of air. Thermostatic Bellows Traps operate on two different principles: Fail Close Design - The bellows is partially filled with distilled water under high vacuum and is compressed by the pressure-difference. The valve is now open for discharge. When steam enters, vapor pressure inside the bellows equals trap pressure, permitting spring action of bellows to close the valve fast. As condensate collects, it takes heat from Bellows lowering internal pressure. Line pressure will then compress Bellows to open the valve and then discharge condensate. The valve opening automatically adjusts to load conditions from minimum on light loads to full lift at maximum load. If Bellows fails (seal lost at some point) Bellows will go to its relaxed position which will close the valve. Fail Open Design - The Bellows is filled at its free length with a liquid having a lower boiling point than water. As assembled, the valve is normally open, when steam or very hot condensate enters trap, Bellows fill vaporizes to a pressure higher than line pressure, this forces the valve into the seat orifice to prevent any further flow. Opening of the valve is identical to Fail Close Design. If Bellows fails (seal lost at same point) Bellows will go to its relaxed position which will open valve. PSIG at Inlet 1/2" & 3/4" L-200W LILLY BELLOWS THERMOSTATIC STEAM TRAPS Maximum Capacity in Pounds per Hour Condensate 10 F Below Steam Temperature 1/4" to 3/4" A & AHV 1" A & AHV 1/2" B & C 3/4" B & C TRAP SIZE AND STYLE 1" & 1-1/4" B & C 1-1/2" & 2" B & C 1/2" CS 3/4" CS 1" & 1-1/4" CS 1-1/2" & 2" CS 1 220 745 985 985 1460 1825 2760 985 1460 1825 2760 2 330 1050 1390 1390 2055 2575 3890 1390 2055 2575 3890 5 550 1650 2180 2180 3240 4050 6120 2180 3240 4050 6120 10 825 2325 3070 3070 4560 5700 8610 3070 4560 5700 8610 15 1030 2460 3255 3225 4825 6035 9125 3255 4825 6035 9125 20 1210 2825 3735 3735 5550 6925 10470 3735 5550 6925 10470 40 1750 3430 4525 4525 6705 8400 12700 4525 6705 8400 12700 50 1975 3815 5040 5040 7480 9350 14125 5040 7480 9350 14125 60 2160 4145 5480 5480 8140 10180 15390 5480 8140 10180 15390 80 2535 4530 5990 5990 8895 11115 16815 5990 8895 11115 16815 100 2825 5035 6645 6645 9865 12340 18660 6645 9865 12340 18660 125 3140 5535 7315 7315 10850 13565 20520 7315 10850 13565 20520 150 3425 5720 7560 7560 11225 14030 21235 7560 11225 14030 21235 175 3580 6085 8045 8045 11935 14920 22580 8045 11935 14920 22580 200 3650 6210 8200 8200 12165 15230 23015 8200 12165 15230 23015 225 8615 12770 15960 24190 8615 12770 15960 24190 250 8915 13225 16540 25055 8915 13225 16540 25055 300 9220 13685 17120 25915 * NOTE: L200WR (3/16 Orifice) = 0.63 x L200W Trap Capacity EFFECT OF BACK PRESSURE ON STEAM TRAP CAPACITY Back Pressure as Percent of Inlet Pressure Percent Reduction of Trap Capacity 20 25 30 40 50 60 70 80 90 0 0 2 5 12 20 30 40 55 2

Lbs. per hr. MODEL L200W APPLICATIONS L-200W Series Thermostatic Steam Traps are designed for a wide range of services including plating tanks, platen presses, unit heaters, sterilizers and various types of cooking and laundry equipment. They are also widely used as air vents for receivers, water heaters and mechanical traps. They are suitable for use on super-heated steam because the trap closes on saturation temperature, and superheated steam cannot reach the trap. The L-200WR Thermostatic Steam Traps are designed for light load applications such as tracer lines and drip legs. DESIGN FEATURES Less maintenance is inherent in the design simplicity of these models. All parts, the bellows, valve and seat, body, and cover, are top quality materials. They are precision-assembled into a steam trapping unit of exceptional efficiency, a trap that functions on just a few degrees temperature differential between steam and condensate to open the trap for fast, positive discharge. CONSTRUCTION In addition to simplicity of design, they are exceptionally rugged in construction. Forged steel body and cover withstand rugged service. Hardened stainless steel valve and valve seat are lapped together for tight positive shut-off. These traps are available with socket weld connections when specified. MODEL L-200W *Full Flow Orifice For Maximum Capacity MODEL L-200WR *Reduced Orifice For Maximum Steam Savings *Fail Open Welded Stainless Steel Bellows *Resistant to Hydraulic Shock *Stainless Steel Internal Strainer MODEL L-200W MODEL L-200WR For pressures from vacuum to 200 psig. Maximum temperature in trap: 500 F with stainless steel bellows. PIPE SIZES: ½ - ¾ Installed horizontally or vertically. Straight through female pipe thread inlet and outlet. Freeze-proof when installed vertically. For capacities see Page 2. Maximum Steam Loss in Fall Open Position 40 30 20 10 5 18.1 13.6 9.0 4.5 2.3 3 1.4 0 10 25 50 100 200 (0) (0.7) (1.75) (3.5) (7.0) (14.0) Kg per hr. PSIG (bar, in gauge unit) Graph is based on trap discharging to atmosphere and no load present. Backpressure and load will reduce steam loss. TRAP PIPE VALVE DIMENSIONS MODEL SIZE ORIFICE A B C D WEIGHT L200W 1/2" & 3/4" 1/4" 3 11/16" 3-5/8" 2-7/8" 3 lbs 3

MODELS A and AHV APPLICATIONS Types A and AHV are for small and medium size items of equipment with low and medium steam requirements, such as process and storage tanks, sterilizers, and various types of cooking and laundry equipment. Also applicable as automatic air vents for mechanical traps, return traps, receivers and water heaters. Type AHV traps applicable where it is necessary or desirable to have all piping run horizontally or vertically, or close to a floor, wall or pillar. CONSTRUCTION MATERIALS Bronze construction. Valves and seats are hardened stainless steel. Bellows are hydraulically formed from seamless tube, heliarcwelded to end fittings. Silver-brazed sealing plug. Stainless steel bellows recommended for all applications. TYPE A For pressures from vacuum to 200 lbs. Made in five pipe sizes: ¼ - 3/8 - ½ - ¾ - 1 Maximum temperature 425 F inside trap. Horizontal inlet and vertical outlet. Freeze-proof. For capacities see Page 2. Bellow s Material Stainless Steel A-13 A-23 A-33 A-43 A-53 Valve Pipe Size Orifice A B C D W eight 1/4" 5/16" 2-3/8" 2" 4-3/8" 3" 3.4 lbs 3/8" 5/16" 2-3/8" 2" 4-3/8" 3" 3.4 lbs 1/2" 5/16" 2" 1-5/8" 4-3/16" 3" 3.3 lbs 3/4" 5/16" 2" 1-7/8" 4-7/16" 3" 3.3 lbs 1" 3/8" 2-13/16" 2-13/16" 4-15/16" 3-7/16" 4.8 lbs TYPE AHV For pressures from vacuum to 200 lbs. Made in five pipe sizes: ¼ - 3/8 - ½ - ¾ - 1 Maximum temperature 425 F inside trap. Straight-through inlet and outlet. Freeze-proof when installed vertically. For capacities see Page 2. Bellow s Material Stainless Steel AHV-13 AHV-23 AHV-33 AHV-43 AHV-53 Valve Pipe Size Orifice A B C D Weight 1/4" 5/16" 4-3/4" 3/4" 3-7/8" 3" 3.2 lbs 3/8" 5/16" 4-3/4" 3/4" 3-7/8" 3" 3.2 lbs 1/2" 5/16" 4" 3/4" 3-7/8" 3" 3.1 lbs 3/4" 5/16" 4-1/4" 7/8" 4-1/4" 3" 3.6 lbs 1" 3/8" 5-5/8" 1" 4-9/16" 3-7/16" 5.3 lbs 4

MODELS B, C and CS APPLICATIONS Types B, C and CS are recommended for the individual drainage of unit heaters, pipe coils, steam mains, high pressure drips, blast coils, dry kilns, jacketed kettles, hot water heaters, driers of all kinds, and many other types of steam-using industrial units of process work. Type B has two outlets, suitable for either horizontal or angle piping. Types C and CS drain completely when cold, and cannot freeze. CONSTRUCTION MATERIALS Types B and C of cast iron construction. Type CS furnished in cast steel. Stainless steel bellows recommended for all applications. Maximum temperature: stainless steel bellows 500 F. Suitable for use on superheated steam. Because the trap closes on saturation temperature, superheated steam cannot reach the trap. Temperature ratings shown are for actual temperature inside the trap, not at the steam main. All bellows are heliarch-welded (not soldered) to end fittings. Type CS available with socket weld connections when specified. TYPE B For pressures from vacuum to 250 lbs. Made in six pipe sizes: ¼ - ½ - 1-1¼ - 1½ - 2 Maximum temperature 450 F inside trap. Horizontal inlet and horizontal or vertical outlet. Not freeze-proof. Pipe plugged drain connections furnished only when specified. For capacities see Page 2. Bellows Material Stainless Steel B-33 B-43 B-53 B-63 B-73 B-83 Valve Pipe Size Orifice A B C D Weight 1/2" 3/8" 3-7/8" 1-1/8" 5-7/8" 4-1/2" 7.0 lbs 3/4" 7/16" 4-1/4" 1-3/8" 6-3/4" 5-1/16" 10.3 lbs 1" 1/2" 5-1/2" 1-7/8" 7-11/16" 5-13/16" 15.6 lbs 1-1/4" 1/2" 5-1/2" 1-7/8" 7-11/16" 5-13/16" 15.3 lbs 1-1/2" 3/4" 7-1/4" 1-3/4" 9-1/16" 7-3/4" 33.6 lbs 2" 3/4" 7-1/4" 1-3/4" 9-1/16" 7-3/4" 32.4 lbs TYPE C AND CS Bellows Material Stainless Steel C-33 C-43 C-53 C-63 C-73 C-83 CS-33 CS-43 CS-53 CS-63 CS-73 CS-83 Type C pressures from vacuum to 250 lbs. (cast iron). Maximum temperature 450 F inside trap. Type CS pressures from vacuum to 300 lbs. (cast steel). Maximum temperature 500 F inside trap. Made in six pipe sizes: ¼ - ½ - 1-1¼ - 1½ - 2 Horizontal inlet and vertical outlet. Freeze-proof. For capacities see Page 2. Valve Pipe Size Orifice A B C D Weight 1/2" 3/8" 2-5/8" 1-13/16" 4-15/16" 4-1/2" 8.3 lbs 3/4" 7/16" 2-3/4" 2-1/16" 5-7/16" 5-1/16" 11.1 lbs 1" 1/2" 3-1/2" 2-13/16" 6-1/16" 5-13/16" 17.8 lbs 1-1/4" 1/2" 3-1/2" 2-13/16" 6-1/16" 5-13/16" 17.5 lbs 1-1/2" 3/4" 5" 3-3/4" 8-3/8" 7-3/4" 39.1 lbs 2" 3/4" 5" 3-3/4" 8-3/8" 7-3/4" 39.0 lbs 1/2" 3/8" 2-5/8" 1-13/16" 4-15/16" 4-1/2" 8.6 lbs 3/4" 7/16" 2-3/4" 2-1/16" 5-7/16" 5-1/16" 13.0 lbs 1" 1/2" 3-1/2" 2-13/16" 6-1/16" 5-13/16" 19.6 lbs 1-1/4" 1/2" 3-1/2" 2-13/16" 6-1/16" 5-13/16" 19.3 lbs 1-1/2" 3/4" 5" 3-3/4" 8-3/8" 7-3/4" 39.2 lbs 2" 3/4" 5" 3-3/4" 8-3/8" 7-3/4" 38.4 lbs 5

SALES POLICY Guarantee: The manufacturer guarantees its products to be free from defects in material or workmanship for a period of one year from date of shipment from its factory. Said guarantee will not apply if equipment is used in conditions of service for which it is not specifically recommended. The manufacturer is not responsible for damage or poor operating practice. If any device is found unsatisfactory under the guarantee, the buyer should notify the manufacturer in writing and after receipt of shipping advice, buyer may return it direct to Lilly Steam Trap, Inc., carrying charges prepaid. Such equipment will be replaced or put in perfect operating condition, free of all charges except transportation, and the correction of any defects by repair or replacement by the manufacturer shall constitute fulfillment of all obligations to the purchaser. Manufacturer s Guarantee is void if unauthorized repairs are made to its apparatus, even though defective. Manufacturer shall not be liable for consequential damage in case of any failure to meet the conditions of any Guarantee or Shipping Schedule, nor will claims for labor, loss of profits, repairs or other expenses incidental to replacement be allowed. Lilly Steam Trap, Inc. 427 W. Irving Park Road Itasca, Illinois 60143 (630) 773-2222 Fax: (630) 773-3443 www.lillyengineering.com info@lillyengineering.com

Lilly Steam Traps, Inc. P.O. Box 173 Itasca, IL 60143 (630) 773-2222 Fax: (630) 773-3443 Thermostatic Steam Trap, Model L500 L500 Operating Principle Thermal actuator is filled at its free length with a liquid having a lower boiling point than water. As assembled, valve is normally open. When very hot condensate enters trap, thermal actuator fill vaporizes to a pressure higher than line pressure; this forces valve into seat orifice to prevent any further flow. As condensate collects, it takes heat from the actuator lowering internal pressure. Line pressure will then compress thermal actuator to open valve and discharge condensate. Valve opening automatically adjusts to load conditions from minimum on very light loads to full lift at maximum load. Sealed Stainless Steel Body Lightweight, compact, and corrosion resistant. No bolts or gaskets. Eliminates body leaks. Temperature Sensitive Actuators One moving part. Stainless steel, fail open, welded actuator form maximum corrosion, thermal and hydraulic shock resistance. Thermal and Hydraulic Shock Resistant Impingement plate plus welded construction prevents damage to actuator. Valve and Seat Long life. Hardened stainless steel valve and seat. Lapped as a matched set for water tight seal. Maintenance None. Trap is sealed maintenance-free unit. Replacement traps costs less than repair costs of other more expensive in-line repairable traps. Freeze Proof Self draining when installed vertically. Directional Discharge Pipe thread erosion prevented by directing discharge to center of pipe. Guarantee Traps are guaranteed against defects in materials or workmanship Traps with Welded Actuator 1 Year Additional features Best air handling capability for fast start up and operation. Fastest response to condensate load or temperature changes. Broad application range. Selection of orifice and pipe sizes meet majority of condensate removal demands.

Thermostatic Steam Trap, Model L500 Applications: B A L500 Unit Heaters Air Vents Cooking Kettles Laundry Equipment Other Process Equipment Drip Legs Platen Presses Plating Tanks Sterilizers L500L Steam Tracing NPT 1/2 3/4 Inch (mm) A B 3-3/4 (94) 3-15/16 (100) 1-3/4 (44) 1-3/4 (44) Weight lb. (kg) 1.1 (0.45) 1.2 (0.54) o Maximum Capacity-lbs/hr 10 F Below Saturation (Kg/hr 5 o C Below Saturation) Trap L500 Orifice Inch (mm) 1/4 (6) 5 (0,34) 550 (249) 10 (0,7) 825 (374) 20 (1,4) 1210 (549) 50 (3,5) 1975 (896) 100 (6,9) 2825 (1281) 125 (8,62) 3140 (1424) 150 (10,3) 3425 (1554) PSIG (bar) 200 (13,8) 3650 (1656) 250 (17,2) 3960 (1796) 300 (20,7) 4100 (1860) 350 (24,1) 400 (27,6) 450 (31,0) 500 (34,5) 600 (41,4) 650 (44,8) L500L 5/64 (2) 84 (38) 119 (54) 168 (76) 265 (120) 348 (158) 375 (170) 398 (181) 439 (199) 472 (214) 502 (228) 529 (240) 553 (251) 575 (261) 595 (270) 1 Welded Thermal Actuator-Fail Open to 150 PSIG 2 Welded Thermal Actuator-Fail Open to 500 PSIG Effects of back pressure on trap capacity Back pressure as percent of inlet pressure Percent reduction of trap capacity 10 20 25 30 40 50 60 70 80 90 0 0 0 2 5 12 20 30 40 55 Lilly Steam Traps, Inc. P.O. Box 173 Itasca, IL 60143 (630) 773-2222 Fax: (630) 773-3443