USB Multi Function Dataloggers. RHT30 Humidity/Temperature Datalogger. TH30 Dual Temperature Datalogger

Similar documents
USER MANUAL USB Multi-Function Datalogger Model RHT35

USER MANUAL Digital CO Monitor Model CO30

Indoor/Outdoor Temperature Alert

Wet Bulb Thermo-Hygrometer Datalogger

USER GUIDE Heat Index Psychrometer

USER GUIDE. Formaldehyde (HCHO or CH 2 0) and Total Volatile Organic Compounds (TVOC) Tester. Model VFM200

User Manual. Humidity-Temperature Chart Recorder. Model RH520

USER GUIDE. Paperless Humidity/Temperature Chart Recorder. Model RH520A 21.2 C 13:

Model VFM200. User Manual. Formaldehyde (HCHO or CH 2 0) and Total Volatile Organic Compounds (TVOC) Tester

Specifications Minimum Typical Maximum Unit

USER MANUAL. ITAG 4 / ITAG 4 Bio/ ITAG 4 TH DATA LOGGER. UM-ITAG REV.B 03/02/2016

THL2. Temperature/Humidity USB Datalogger INSTRUCTION MANUAL

EL-USB-1-LCD Temperature Data Logger with LCD

iminiplus PDF User Guide Version 2.0

THERMO BUTTON HYGRO BUTTON The smallest temperature and humidity loggers in the world!

USER MANUAL ENVIRONMENTAL METER. Model EN510. Additional User Manual Translations available at

2014, TempSen Electronics Company

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL THL1

Pinless Moisture/Humidity Meter with Memory + IR Thermometer

Instruction Sheet THERMOCOUPLE DATA LOGGER WITH LCD DISPLAY AND USB INTERFACE

EasyLog Data Logger Series

Carbon Monoxide Meter Model CO15. User Manual. Additional User Manual Translations available at

EL-USB-1-LCD Temperature Data Logger with LCD

Introduction. OM-THA2

EL-USB-CO300 Carbon Monoxide (CO) Data Logger with USB Interface

The data logger is supplied with a lithium metal battery which typically gives two years logging life.

EasyLog Data Logger Series

HOBO U14 Data Logger User Manual

User's Guide. Pinless Moisture Meter. Model MO257

EL-USB-2-LCD+ High Accuracy Humidity, Temperature and Dew Point Data Logger with LCD

Follett Performance Plus

THA2 TEMPERATURE/ HUMIDITY/ DEWPOINT ALARM WITH LOGGING CAPABILITY. 99 Washington Street Melrose, MA Phone Toll Free

User's Guide. Pinless Moisture Meter. Model MO257

Mini InfraRed (IR) Thermometer with Type K Input and Laser Pointer

ORDERING INFORMATION FEATURES EL-WIN-USB (CONTROL SOFTWARE) Maximum Speci cations Typical Minimum Unit

actoolsupply.com User Guide Extech RD300 Air Conditioning AC Refrigerant Leak Detector Refrigerant Leakage Detector Model RD300 actoolsupply.

ELMTEC. Kattreppeln Königslutter / /

User Manual. Dryer Controller M720

WiFi Hints & Tips. Contents. WiFi Hints and Tips 1. Page No. Section No. Title

User's Guide. CO 2 Monitor. Model CO200

i.c³ User Guide For Helmer i.series Ultra-Low Freezers A/A

Dual Laser InfraRed (IR) Thermometer

High Temperature InfraRed Thermometer with Laser Pointer

UTRED day Logger with display

ECOLOG TN2, TN3-P, TN4, TN4-L, TP2, TP4-L,TH1, TH2

NYS Vaccines for Children (VFC) Program Fridge-Tag 2L Data Logger: Implementation and User Guide

Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer

EL-USB-TC Thermocouple Data Logger with USB Interface

CO2 RESPONDER Portable Carbon Dioxide Detector QUICK REFERENCE GUIDE

GasAlertMicroClip X3 Specifications

User's Guide. Pinless Moisture/Humidity Meter with Memory + IR Thermometer. Model MO295

LogTag Recorders TRED30-16R. Temperature Recorder with Display and 30 Day Statistics Memory. Product User Guide

AS950 PORTABLE SAMPLERS

USRIC-8(M) USB PDF Temperature Recorder. Product User Guide. LogTag Recorders Ltd

OPERATING INSTRUCTIONS. G214 Software - Version 4

User Guide InfraRed (IR) Thermometer with Wireless Datalogger, Type K input & Laser Pointer MODEL 42560

THX-DL Data Logger USER & INSTALLATION MANUAL V

UTRED30-WiFi. 30 day WiFi Logger with display

Dryer Controller M720

User's Guide. Pinless Moisture/Humidity Meter + IR. Model MO290

EL-OEM-3 OEM Packaged Voltage Data Logger

Sirius Technologies, Inc.

User Manual. Digi-Sense TC9600 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

4-in-1 Humidity, Temperature Airflow and Light Meter

Dual Laser InfraRed (IR) Thermometer

AS950 ALL-WEATHER REFRIGERATED SAMPLERS

RGR150 USER S MANUAL. Wireless Rain Gauge with Thermometer and Clock

Alarm Client. Installation and User Guide. NEC NEC Corporation. May 2009 NDA-30364, Revision 9

EL-OEM-3 OEM Packaged Voltage Data Logger

Ambient Temperature/ Relative Humidity & Dew Point Temperature Sensors to USB Output. Model LFS108B

Q-tag CLm doc family Type: doc / doc L / doc LR / doc D

MGC Dock User s Manual

USB DATA LOGGER FOR TEMPERATURE AND RH HM9000

Honeywell. Wireless Rain Gauge with Indoor. Temperature (TC152) USER MANUAL TABLE OF CONTENTS INTRODUCTION 3 PRODUCT OVERVIEW 4 REMOTE RAIN GAUGE 7

PHASE NON-COIN USER S MANUAL (S.A.F.E.)

BST-MG08/09 Multi-gas Detecting Alarm. Manual Instruction

User Manual. Digi-Sense TC9500 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

ThermoBarScan TM Electronics UK Ltd INSTRUCTION BOOKLET

CDL 210. Operating manual. CO2 Logger. Best.-Nr

DataSheet. Thermocouple Logger


What's new in LogTag Analyzer 2.8

DataSheet. Thermocouple Logger

AS950 REFRIGERATED SAMPLERS

3D_ISS. Integrated Software System. User Guide Manual

Wireless Rain Gauge with Indoor Temperature

Visit us at testo 835 Infrared and contact thermometer

Professional Wireless Rain Guage with 4" LCD

OPERATION MANUAL TEMPERATURE. HUMIDITY MONITOR / ON-LINE LOGGER. Monitor. On-line Logger AMT208 AMT207

LONG-RANGE WIRELESS WEATHER STATION WITH IN-OUT THERMO-HYGROMETER AND RF CLOCK

i.c³ User Guide for Compartmental Access Refrigerators

TV2 Room Pressure Monitor Quick Start Guide

Mark 25 Ultrapure Water Conductivity Analyzer

Operations Manual TS400. Test Station for G450/G460 Gas Detector

LogTag Recorders Ltd TRED30-16R. Temperature Recorder with Display and 30 Day Statistics Memory. Product User Guide

Dashboard for Windows V1.1.0

Dryer Master Inc. Dryer Master AM 3. Product Manual

Adaptive CyCLO Technical and HMI User Guide. CyCLO User Guide. Version th December 2017 REV

MR SERIES CARD LOGGERS

WeatherLink for Alarm Output Addendum

Transcription:

USER MANUAL USB Multi Function Dataloggers RHT30 Humidity/Temperature Datalogger TH30 Dual Temperature Datalogger Additional User Manual Translations available at www.extech.com

Introduction Thank you for selecting the Extech multi function, easy to use, portable USB datalogger. The RHT30 offers temperature and humidity logging and the TH30 offers internal (air) and external (probe) temperature logging. These USB dataloggers can be configured and customized by the user by plugging them into a PC USB port, following the on screen prompts, and making selections on the supplied PDF Logger Configuration Tool. These devices are shipped fully tested and calibrated and, with proper use, will provide years of reliable service. Please visit our website (www.extech.com) to check for the latest version of this User Manual, Product Updates, and Customer Support. Features Plug and play datalogger with USB connector. No USB driver required User configurable datalogging settings via supplied PC software tool Advanced Datalogger functions including delayed start, high/low alarms, bookmarking, and password protection Automatically generate PDF and Microsoft Excel datalog reports High accuracy thermistor temperature sensor on both models with capacitive humidity sensor on the RHT30 Compact light weight design Large LCD for easy viewing Dual color (red and green) LED status indicator for datalogger progress, PC connection status, and high/low alarms Large memory capacity: 48,000 readings Descriptions Datalogger Description 3 4 5 6 7 1. External temperature sensor (TH30 only) 2 2. External temperature sensor connection to datalogger (TH30 only) 3. Protective cover and swivel stand (remove to expose USB plug). Rotate the cover for best desktop viewing angle. 8 1 9 4. LCD display. Refer to the Display Description later in this section. 2 RHT30_TH30 en GB_V1.0 (11/16)

5. Status LED indicator (red/green). Refer to the Status LED Indicator Description later in this section. 6. MAX MIN button. Refer to the Button Descriptions later in this section. 7. Sensors (Thermistor internal air temperature and capacitive RH sensor) 8. Power and Datalog Start/Stop button. Refer to the Button Descriptions later in this section. 9. MARK/Battery life button. Refer to the Button Descriptions later in this section. 11 12 10. USB plug 11. Battery compartment (CR2032 x 2) on rear 12. Wall hanging mount (rear). Mounting screw supplied. Button Descriptions POWER button. Short press to power ON or OFF. Note that the datalogger cannot be switched OFF while datalogging is in progress. START/STOP button (same physical button as the Power button above). Press and hold for 5 seconds to start or stop the datalogger. Note that the datalogger will not start unless it has been configured using the PDF Logger Configuration Tool.exe program as described later in this user manual. 10 Maximum Minimum Reading button. At any time, short press to step through the highest (MX) and lowest (MIN) readings recorded in the current datalogging session. Bookmark button. Manually place a time stamped bookmark in the datalog report by pressing and holding the button until the displayed measurement flashes 3 times. Up to eight (8) bookmarks can be saved. Battery Status Note: Short press the MARK button to display the approximate number of days remaining for the battery life. 3 RHT30_TH30 en GB_V1.0 (11/16)

Display (LCD) Description o F o C RH% T1 T2 H L REC MX MN Temperature unit of measure as programmed by the user Displayed when showing Relative Humidity reading (RHT30) Represents the internal sensor (air) temperature (TH30) Represents the external probe temperature. If no probe is connected, the display will show dashes for the T2 temperature reading (TH30) High Alarm triggered Low Alarm triggered REC flashes once per second when actively datalogging. When logger is programmed with a Start Delay, REC is displayed but does not flash until after the delay time has elapsed and the logging begins Battery icon flashes once per second when battery level is critically low Displayed when the maximum recorded reading is selected with the MAX MIN button Displayed when the recorded minimum (MN) reading is selected with the MAX MIN button LED Status Indicator Description The dual color (red/green) LED status indicator is located to the right of the LCD. Red (Alarm): Blinks red every 10 seconds in an alarm condition Green (Datalogging): Blinks green every 10 seconds while actively datalogging Green (PC connection): Glows steady green while establishing connection to PC 4 RHT30_TH30 en GB_V1.0 (11/16)

PDF Logger Configuration Tool Connect the datalogger to PC USB port. The PC will prompt to view files. Open the PDF Logger Configuration Tool from the list of available files. Refer to the Operation Section for additional details on this tool: 3 4 2 1 5 6 7 8 15 14 13 9 10 11 12 1. CONVERT TO EXCEL: Create a spreadsheet report of the logged data 2. CONVERT TO PDF: Create a PDF report and a trend graph of the logged data 3. CONFIGURATION: Click to configure the logger 4. LANGUAGE SELECTION 5. SAMPLING RATE: Datalogger recording interval 6. START DELAY: Delay period from when START is pressed and datalogging begins 7. TEMP. UNIT: Temperature unit selection ( o C/ o F) 8. PASSWORD: Select a 16 character password for tamper protection 9. COMPANY NAME: 20 Character user label for inclusion in logging report 10. SAVE: Press SAVE to confirm the configuration 11. MANUAL: Open the supplied PDF User Manual 12. CANCEL: Abort the configuration 13. ALARM LIMIT: Select the RH% and Temperature low/high alarm limits. Note that for the TH30, RH% is replaced by external temperature probe alarm limit 14. ALARM DELAY: Datalogger will ignore alarms for the programmed period of time 15. ALARM TYPE: Select Alarm mode 5 RHT30_TH30 en GB_V1.0 (11/16)

Operation NOTES: 1. Adobe Reader software is required. 2. Ensure the logger is at room temperature before inserting it into a PC port. 3. The executable file for programming is named PDF Logger Configuration Tool. 4. A datalogging session cannot start until the datalogger is properly configured. Configuring the TH30 and RHT30 for a Datalogging session At any time before logging is started, the logger can be programmed and reprogrammed. The previous logging session will be deleted once a new session is started. 1. Connect the data logger to a PC via the USB port. The logger will switch ON automatically. Note that a short press of the power button will also power the logger. 2. The LED will glow green while a connection with computer is being established. 3. An AutoPlay prompt will appear on the PC when communication is established. 4. Click on Open folder to view files to see the available files. Open the program "PDF Logger Configuration Tool.exe". 5. The default language is English; select German, French, Italian, Spanish, or Portuguese as desired. The generated logging report format will match the language selected. 6. To review the User Manual, click Manual to open the User Manual PDF file. 7. The parameters needed to configure the datalogger for logging are defined below. Refer to the earlier screen shot of the PDF Logger Configuration Tool window for reference: Datalog Sampling Rate Select the datalogging sampling rate (recording interval) from 30 seconds ~ 120 minutes. The default setting is 30 seconds. Datalog Start Delay Select a period of time that must elapse before recording can begin after the Start/Stop button is pressed (select from 0 min to 24 hours). The default setting is 0 minutes. Temperature Unit of Measurement Select the temperature unit C or F. 6 RHT30_TH30 en GB_V1.0 (11/16)

Alarm Delay The preset alarm delay time for the Single Event Alarm mode is always zero. The adjustable delay time range for the Cumulative Alarm is 5 ~ 120 minutes. Alarm Modes Single Event Alarm mode: The LED immediately starts flashing red every 10 seconds when the measured value exceeds the alarm threshold. Cumulative Alarm mode: The LED begins flashing red only after the average value exceeds the alarm threshold and also after any programmed Alarm Delay time. See Alarm Delay parameter above. Alarm Disable (default): Alarm function disabled. Alarm Note: The LED will continue flashing red every 10 seconds (once it is triggered by an alarm) even when the measurement later returns to the normal range. To stop the LED alarm, plug the logger into the PC USB port to generate a report, or power off the logger (short press of the power button while it is not connected to the PC). Alarm Limits Select the alarm threshold ranges for air and external probe temperature (TH30) or air temperature and RH% (RHT30). For example, if the external probe temperature range is set to 2.0~8.0 o C, when the measurement falls below 2 o C or exceeds 8 o C the LED will flash red every 10 seconds. Note: If an alarm occurs between two logging points, the logged data will not show the alarm but the LED may still flash red every 10 seconds, especially in Single Event alarm mode. If desired, use the Cumulative Alarm mode to minimize this effect. Password A 16 alphanumeric character (max.) password may be used to prevent unauthorized re programming. User Company Name Input a company name to be included on the log report (20 characters max.). A Note On Time Zones The logger automatically synchronizes the time zone with the connected PC when SAVE is selected. Note: Time zone changes occurring during logging are not taken into account. Once all the programming is complete, press SAVE to confirm the settings. Close the setup window, remove the logger from the PC USB port, and start datalogging as described in the next section. 7 RHT30_TH30 en GB_V1.0 (11/16)

Start Datalogging 1. Configure the logger as previously described and then hold the Start/Stop button for 5 seconds to start logging. 2. Measurements update on the display every 10 seconds. For the RHT30 the temperature and RH% displays toggle every 5 seconds. 3. If the logger is programmed with a Start Delay: After pressing and holding the Start/Stop button for 5 seconds to start logging, REC will appear on the LCD but will not flash until the delay time has elapsed and logging has begun. 4. When the datalogger is successfully running, the LED flashes green every 10 seconds (as long as there is no alarm). Monitoring Alarms While Datalogging The LED will flash RED every 10 seconds when there is an alarm. The display also shows L for low alarm and H for high alarm. To stop the LED from flashing red, plug the logger into a PC, or power off (short press of the power button). Placing Bookmarks While Datalogging To place a bookmark manually during datalogging, press and hold the MARK button until the measured reading flashes 3 times. Up to eight (8) bookmarks can be placed; the bookmarks will appear in the logging report. MAX MIN Readings Short press the MAX MIN button to step through the highest (MX) and lowest (MN) readings stored in memory. Checking Battery Status At any time, short press the MARK button to view the approximate number of days remaining for battery life. If battery power is critically low, the battery icon will blink once per second on the LCD display. Downloading Logged Data (PDF and Spreadsheet Datalog Reports) 1. Press and hold the Start/Stop button for 5 seconds to stop the datalogger. 2. Plug the logger into the PC USB port (this also stops the datalogger). 3. Open the PDF logger Configuration tool from the list of available files. 4. Choose Convert to PDF or Convert to Excel to generate a report. 5. Select the PC file location where the report is to be saved. 6. The PDF report includes the recorded data, bookmarks, and a trend graph. The spreadsheet report contains the same data as the PDF report minus the trend graph. 8 RHT30_TH30 en GB_V1.0 (11/16)

Specifications Display (LCD) Status indicator (LED) 5 digit LCD with multi function indicators Dual color multi purpose LED (red/green) for active logging, alarms, and PC connection status Temperature Sensors NTC Thermistors (TH30/RHT30 internal temperature sensors and TH30 external temp. probe) Ext. Temperature probe length 2.1m (84 ) (TH30) Temperature range 30 ~ 70 o C ( 22 ~ 158 o F) internal and external probes Temperature resolution 0.1 o C/ o F Temperature Accuracy ±0.5 o C (0.9 o F) for internal and external (TH30) probe Humidity Sensor Capacitive (Relative Humidity) RHT30 only Humidity range 0.1 ~ 99.9%RH Humidity resolution 0.1%RH Humidity Accuracy ±3% at 25 o C (10 ~ 90%RH), ±5% all other ranges Logger Type Re usable Datalogger capacity TH30: 24000 air temperature/24000 external probe temp. readings RHT30: 24000 temperature/24000 humidity (RH%) readings Sampling intervals 30 seconds and 5, 10, 30, 60, 90, 120 minutes Start delay time 0, 5, 30, 45, 60, 90, 120 minutes, and 24 hours Alarm ranges Temp: 30~70 o C ( 22~158 o F); Humidity: 1 to 99%RH Alarm delay (inhibit) 0, 5, 30, 45, 60, 90, 120 minutes Alarm types Single Event, Cumulative, and Disable Operation Buttons Power/Start Stop, MARK, MAX MIN Operating temperature 30~70 o C ( 22~158 o F) for logging; Allow logger to return to room temperature before connecting to PC Operating Relative Humidity < 80% RH Storage temperature 40~85 o C ( 40~185 o F) Storage Humidity < 90% RH Dimensions 80 (L) x 43 (W) x 2.5 (D) mm (3.2 x 1.7 x 0.1 ) Weight 90g (3.2 oz.) Battery Two (2) 3.0V CR2032 batteries (pre installed) Battery life Three (3) months Safety Compliance CE Warranty One Year 9 RHT30_TH30 en GB_V1.0 (11/16)

Maintenance Battery Replacement The battery compartment is located on the back of the datalogger as shown in the Descriptions section. When the battery symbol flashes on the display, replace the batteries promptly. 1. Using a large coin, rotate the battery compartment lid clockwise approximately one quarter turn to open the compartment 2. Replace the two (2) CR2032 batteries with positive (+) side facing up 3. Replace the battery compartment lid and turn counterclockwise to secure it 4. Dispose of batteries in accordance with country, state, and local regulations Never dispose of used batteries or rechargeable batteries in household waste. As consumers, users are legally required to take used batteries to appropriate collection sites, the retail store where the batteries were purchased, or wherever batteries are sold. Disposal: Do not dispose of this instrument in household waste. The user is obligated to take end oflife devices to a designated collection point for the disposal of electrical and electronic equipment. Battery Status Check To check the approximate number of days of battery life remaining, short press the MARK button. The display will show the number of days and the d for days (XXd). Cleaning Wipe the datalogger with a damp cloth, do not use solvents or abrasives as these may damage the datalogger finish and display lens. Error Display Codes ERROR CAUSE SOLUTION Dashes. External probe unplugged (TH30 only) Check the connection between the external probe and logger E02 Measured value below specified range Operate in the specified range E03 Measured value above specified range Operate in the specified range E04 Temperature error (RHT30 only) Contact Extech for service E11 Humidity check failed (RHT30 only) Contact Extech for service E31 Microprocessor failed Contact Extech for service E33 Humidity measurement error Contact Extech for service Copyright 2016 FLIR Systems, Inc. All rights reserved including the right of reproduction in whole or in part in any form www.extech.com 10 RHT30_TH30 en GB_V1.0 (11/16)